Archive for the ‘Medical Devices R&D Investment’ Category

Curator: Tilda Barliya PhD

Original article by: Philip Tinnefeld (2)

The ability to detect a single chemical at extremely low concentrations and high contamination is vital for earlier disease diagnosis (I). Detecting a single chemical does not only help to detect disease earlier, it is also vital for toxin/drug screening, athlete drug monitoring, environmental surveillance, and homeland security. 

To  detect a single molecule the observation volume must host only one molecule of  interest during the measurement (2). It is impossible to carry out single-molecule detection at concentrations exceeding the picomolar to low-nanomolar range, because the observation volume becomes populated by more than one fluorescent molecule as concentration increases.

This concentration barrier is crucial when using a Single-Molecule Technology such as:

  • protein-protein interactions
  • Enzyme-substrate analysis
  • DNA sequencing
  • etc

Jérôme Wenger and colleagues at AixMarseille Université in France, alongside collaborators at the ICFO-Institut de Ciencies Fotoniques and ICREA-Institució  Catalana de Recerca i Estudis Avançats in Spain, describe a system that brings two complementary nanophotonic approaches  together to achieve single-molecule detection with a high signal-to-noise ratio at a micromolar concentration (1, 2).

In recent years, two alternative nanophotonic approaches were used:

  1. Light is confined to the near-field using nanoapertures of subwavelength dimensions (typically holes in a thin aluminum or gold film on a silica substrate) that do not allow light to propagate through.  Figure 1a
  2. Enhance the excitation field  locally using a nanoantenna that converts  freely propagating optical radiation into localized energy in the form of surface plasmons.  By reducing the volume of the hot spot, it is possible to obtain enormous fluorescence enhancements up to more than 1,000-fold when compared with the case of an isolated fluorophore in solution Figure 1b

The first approach (Figure 1a)  limitations were that although this approach reduces the observation volume and enables single-molecule detection in the micromolar range, further reduction of nanoaperture size has detrimental effects on the fluorescence signal because of the decreased excitation intensity and fluorescence quenching caused by the metal film.

It did however, has some encouraging results: This method has been used, for instance, to monitor the activity of the 
enzyme polymerase1 and follow DNA sequencing in real time; and for visualizing a ribosome in action (3).

The second approach (Figure 1b) limitations were that this approach suffers from the background fluorescence of molecules far away from the hot spot but still within the diffraction-limited excited area.

Nanophotonic approach to enhance single molecule detection

“nanoantenna-in-box”

Wenger and colleagues synergistically combine these two approaches and place a nanoantenna within the spatial confinement of a nanoaperture (Fig. 1c), to which they called “nanoantenna-in the-box.

To demonstrate the capability of their device, they cover it with a solution containing a fluorescent dye and analyse the fluorescence signal coming out from the hot spot using fluorescence correlation spectroscopy (FCS).

The FCS technique measures the number of molecules in the effective observation volume as these diffuse in and out of it, as well as the brightness per molecule.

Limitations:

1. There are, however, a few limitations that  have to be considered. Further reduction of the gap size may result in gaps being too small for biomolecules to enter.

2. The antenna-in-box device exhibits a large surface-to-volume ratio and sticky molecules might adsorb onto the gold surface, especially in the gap, which might lead to rapid surface degradation, surfaceinduced artefacts and other background.

To overcome some of the limitations, the authors used an approach that takes advantage of a recently developed DNA-scaffolded, gap-nanoantenna might represent a viable solution. The two nanoparticles forming the gap-nanoantenna are attached to a self-assembled DNA nanostructure that provides handles to place the biomolecule of interest in the hot spot.

In summary:

“Whatever direction the research field might take, it seems as though the development of sophisticated coverslips in which nanophotonic structures such as the antenna-in-box set-up are incorporated may unlock more potential for single- molecule detection than developing more powerful microscopes”.

Ref:

I. By: Grace Rattue. Nanotechnology For Detecting Diseases Earlier.  http://www.medicalnewstoday.com/articles/245820.php

1. Deep Punj, Mathieu Mivelle, Satish Babu Moparthi, Thomas S. van Zanten, Hervé Rigneault, Niek F. van Hulst, María F. García-Parajó & Jérôme Wenger. A plasmonic ‘antenna-in-box’ platform for enhanced single-molecule analysis at micromolar concentrations. Nature Nanotechnology 8, 512–516 (2013) doi:10.1038/nnano.2013.98. http://www.nature.com/nnano/journal/v8/n7/full/nnano.2013.98.html?WT.ec_id=NNANO-201307

2. By: Philip Tinnefeld. Single-Molecule Detection: Breaking the concentration barrier.  http://www.nature.com/nnano/journal/v8/n7/full/nnano.2013.122.html

3. Sotaro Uemura.,  Colin Echeverría Aitken., , Jonas Korlach.,  Benjamin A. Flusberg., Stephen W. Turner & Joseph D. Puglisi. Real-time tRNA transit on single translating ribosomes at codon resolution. Nature 464, 1012–1017 (2010).  http://www.nature.com/nature/journal/v464/n7291/full/nature08925.html

4. G. P. Acuna, F. M. Möller, P. Holzmeister, S. Beater, B. Lalkens, P. Tinnefeld. Fluorescence Enhancement at Docking Sites of DNA-Directed Self-Assembled Nanoantennas.  Science 26 October 2012: Vol. 338 no. 6106 pp. 506-510.  http://www.sciencemag.org/content/338/6106/506.abstract

Read Full Post »

The Affordable Care Act: A Considered Evaluation. The Implementation of the ACA, Impact on Physicians and Patients, and the Dis-Ease of the Accountable Care Organizations.

The Affordable Care Act: A Considered Evaluation. Part II: The Implementation of the ACA, Impact on Physicians and Patients, and the Dis-Ease of the Accountable Care Organizations.

Writer and Curator: Larry H. Bernstein, MD, FCAP

and

Curator and Editor: Aviva Lev-Ari, PhD, RN 

Article ID #78: The Affordable Care Act: A Considered Evaluation. The Implementation of the ACA, Impact on Physicians and Patients, and the Dis-Ease of the Accountable Care Organizations. Published on 9/13/2013

WordCloud Image Produced by Adam Tubman

INTRODUCTION

This discussion is the second of two distinct chapters. The first is a clarification of what is contained in the Accountable Care Act (ACA), the model of care it is crafted from, the insurance mandate, the inclusion of groups considered high risk and uninsured, the inclusion of groups low risk and uninsured, and the economics involved in going from a fractured for profit health care industry to a more stable coverage for patients with problems in creating a new workable model from an actuarial standpoint, with the built in complexity of not just age, but education, achievement in the workforce, and a consolidating hospital and eldercare industry, the unpredictability of disease evolution, and add on the multicultural and social structures, as well as rapidly evolving communications and computational platforms needed to transform the U.S. Healthcare system.. The second is taken from selected articles on the care process in the New England Journal of Medicine about the cost and consequences for improving quality at lower cost. Dr. Justin Pearlman has chosen this topic to become as the Second Chapter in the Cardiovascular Disease Volume and Dr. Aviva Lev Ari has selected the sub-universe of sources been elaborated on in this Chapter

There are inherent problems at looking at this from a systems point of view, mainly impacted by the relationship of providers to hospitals and clinics, and by the relationships of insurers to the patients and providers in an Accountable Care Organization (ACO) model. These relationships have been evolving for many decades, first with the increased availability of highly skilled medical specialists trained in numerous university-based programs funded by Training Grants from the National Institutes of Health, then a high concentration of these skilled physicians in metropolitan locations, where there was an adequate patient-base for developing groups of refering physicians. Prior to WWII, there were many Asian physicians receiving their postgraduate training in the U.K. The number of foreign graduates coming to the U.S. Increased enormously with the opportunities that opened up in U.S. The first change in medical education that created a science-based professional came after the Flexner Report in 1910, sponsored by the Carnegie Endowment. Many aspects of the present-day American medical profession stem from the Flexner Report and its aftermath.The Report (also called Carnegie Foundation Bulletin Number Four) called on American medical schools to enact higher admission and graduation standards, and to adhere strictly to the protocols of mainstream science in their teaching and research. Joseph Goldberger discovered the cause of pellagra in 1916.  When the 1918 influenza pandemic struck Washington, physicians from the then PHS laboratory were pressed into service treating patients in the District of Columbia because so many local doctors fell ill.

goldberger 1916 Pellagra

http://www.nih.gov/about/lmedia/goldberger.jpg

In 1930, the Ransdell Act changed the name of the Hygienic Laboratory to National Institute (singular) of Health (NIH) and authorized the establishment of fellowships for research into basic biological and medical problems. The roots of this act extended to 1918, when chemists who had worked with the Chemical Warfare Service in World War I sought to establish an institute in the private sector to apply fundamental knowledge in chemistry to problems of medicine. In 1926, after no philanthropic patron could be found to endow such an institute, the proponents joined with Louisiana Senator Joseph E. Ransdell to seek federal sponsorship. The truncated form in which the bill was finally enacted in 1930 reflected the harsh economic realities imposed by the Great Depression. Nonetheless, this legislation marked a change in the attitude of the U.S. scientific community toward public funding of medical research.

bengston_lg nurse in bacteriology lab of NIH

http://history.nih.gov/exhibits/history/assets/images/bengston_lg.jpg

cholera_sm cholera epidemic of 19th century (Koch bacillus)

http://history.nih.gov/exhibits/history/assets/images/cholera_sm.jpg

Vaccines and therapies to deal with tropical diseases were also critically important to the WWII war effort by the PHS. At the NIH’s Rocky Mountain Laboratory in Hamilton, Montana, yellow fever and typhus vaccines were prepared for military forces. In Bethesda as well as through grants to investigators at universities a synthetic substitute for quinine was sought to treat malaria.  Research in the Division of Chemotherapy revealed that sodium deficiency was the critical element leading to death after burns or traumatic shock. This led to the widespread use of oral saline therapy as a first-aid measure on the battlefield. NIH and military physiologists collaborated on research into problems related to high altitude flying. As the war drew to a close, PHS officials guided through Congress the 1944 Public Health Service Act, which defined the shape of medical research in the post-war world. Two provisions in particular had an impact on the NIH. First, in 1946 the successful grants program of the NCI was expanded to the entire NIH. From just over $4 million in 1947, the program grew to more than $100 million in 1957 and to $1 billion in 1974. The entire NIH budget expanded from $8 million in 1947 to more than $1 billion in 1966. Between 1955 and 1968. In this period, there was expansion of the NIH extramural budget, as well, and the grants dispursed were in support of developing the medical faculty of the future. It has nothing to do with then organization of the practice of medicine, but it has contributed much to the widespread quality of american medical education.

flowchart_sm NIH 1949

http://history.nih.gov/exhibits/history/assets/images/flowchart_sm.jpg

 As the cost of healthcare was increasing, mainly after the Korean and Vietnam War periods, there was a medically initiated concept of a National not-for-profit health maintenance organization (HMO), which would be modeled after the likes of Mayo Clinic, Cleveland Clinic, the Kaiser Permanente Plan, and Geisinger. But the insurance industry was already mature, and the hospitals were closely tied to Aetna, CIGNA, and Blue Cross Blue Shields, which had the actuarial pieces needed. Then an HMO industry emerged with a for-profit motive. As the U.S. Became enmesshed in two military engagements in Iraq and Afganistan for a full decade, there was a fierce competition between the need to support military requirements and the need to support the welfare of the community, with brilliant accelerated achievements that brought the Human Genome Project to a successful conclusion in 2003, and from that emerged advances in both clinical laboratory diagnostics and imaging, and which portends to continuing significant advances in treatments in cardiology, surgery, endocrinology, and cancer. In order to succeed, there has been a redesign or rearrangement of how these services are delivered, with a business model intended to – in time – bring down costs, and to also improve quality. Ironically, there is an insufficiency of primary care physicians, even considering internal medicine, pediatrics, obstetrics, and general surgery, as well as osteopathic physicians.

Part I. The Establishment, Structure, and Nature of the Accountable Care Act (ACA)

Part II. The Implementation of the ACA, Impact on Physicians and Patients, and the Dis-Ease of the Accountable Care
Organizations.

Failure to Launch? The Independent Payment Advisory Board’s Uncertain Prospects

Jonathan Oberlander, Ph.D., and Marisa Morrison, B.A.
N Engl J Med 2013; 369:105-107July 11, 2013 http://dx.doi.org/10.1056/NEJMp1306051

The Affordable Care Act (ACA) established the IPAB as a 15-member, nonelected board. Among other duties, the IPAB is empowered to recommend changes to Medicare if projected per-beneficiary spending growth exceeds specified targets. If Congress does not enact legislation containing those proposals or alternative policies that achieve the same savings, the IPAB’s recommendations are to be implemented by the secretary of health and human services. President Obama has proposed strengthening the board’s role by lowering the Medicare spending targets that would trigger IPAB action.

Because the board is prohibited by law from making recommendations that raise revenues, increase cost sharing of Medicare beneficiaries, or restrict benefits and eligibility, it is expected to focus on savings from medical providers. In January 2013, the GOP adopted a House rule declaring that the IPAB “shall not apply” in the current Congress, thereby rejecting the special procedures that the ACA had established for congressional consideration of IPAB recommendations.

On April 30, the chief actuary of the Centers for Medicare and Medicaid Services released a report projecting Medicare spending growth during 2011–2015. According to the report, per-person Medicare spending will grow at an average rate of 1.15% during that period, far below the target growth rate set by the ACA — the average of the Consumer Price Index (CPI) and the Medical CPI (see graph).

8443-exhibit-2-3 increase in medicaid_CHIP all states expanding medicaid50-Graph-4-33_2012 Hospitalization Rates for Heart Failure, Ages 45–64 and 65 and Older, U.S., 1971–2010

8443-exhibit-2-7 nonelderly population uninsured52-Graph-4-35_2012 Total Economic Costs of the Leading Diagnostic Groups, U.S., 2009

http://www.nejm.org/na101/home/literatum/publisher/mms/journals/content/nejm/2013/nejm_2013.369.issue-2/nejmp1306051/20130708/images/small/nejmp1306051_f1.gif

Projected Growth in Medicare Per Capita Spending, the Consumer Price Index (CPI), and the Medical CPI, 2011–2015.

       healthprices time price of HC over 50 yearsjournal.pmed.0020133.g001 Global Mortality and Burden of Disease Attributable to Cardiovascular Diseases and Their Major Risk Factors for People 30 y of Age and Older

NHEbyDCforHS1 NHE annual growth rate of 4%      percentageincreasekff % increase in HI premiums

journal.pmed.0020133.t001 Risk and Socioeconomic Variables Used in the Analysis     T1.large uninsured by health and disability by region 2000-2005

T3.large uninsured by medicaid eligibility        T5 Characteristics Of Insurance, By Insurance Adequacy, Among Insured Adults Ages 19–64, 2007

The rate of increase in Medicare expenditures per enrollee has slowed since 2006, and because Medicare spending growth has moderated, the IPAB will be irrelevant to cost containment. 3 years after the ACA’s enactment, the IPAB still has no members. If no members are appointed, the power to recommend changes to Medicare when spending targets are exceeded does not disappear: it reverts to the secretary of health and human services.

The board’s appeal lies largely in its aspiration to remove politics from Medicare — to create a policymaking process that is informed by experts and insulated from pressures outside their professional overview. If Medicare spending growth accelerates, the IPAB’s role could expand. But that future is uncertain.

Causes_of_death_by_age_group

The Road Ahead for the Affordable Care Act

John E. McDonough, Dr.P.H.
N Engl J Med 2012; 367:199-201 http://dx.doi.org/10.1056/NEJMp1206845
http://www.nejm.org/doi/full/10.1056/NEJMp1206845

The Affordable Care Act (ACA), the U.S. health care reform law enacted in 2010, was upheld as constitutional by the U.S. Supreme Court on June 28, 2012. As a result of the Court’s ruling –

  • the individual responsibility requirement (the individual mandate to obtain insurance coverage),
  • insurance reforms such as the elimination of coverage exclusions for preexisting conditions,
  • the establishment of state health insurance exchanges, and
  • the provision of private health insurance subsidies

stand unaltered despite the Court-ordered switch in the basis for constitutional legitimacy from the Commerce Clause to Congress’s taxing authority.

One consequential outcome of the ruling is the continuing benefit, and harm averted, for millions of Americans from ACA provisions that have already been implemented. Those benefiting include more than 6 million young adults enrolled in their parents’ insurance plans, 5.2 million Medicare enrollees who have saved on prescription-drug costs because of the shrinking Part D “doughnut hole,” 600,000 new adult Medicaid enrollees in seven states that have already expanded Medicaid eligibility, 12.8 million consumers who will receive more than $1 billion in insurance-premium rebates, and many others.

Also undisturbed are the ACA’s numerous system reforms, such as accountable care organizations, patient-centered medical homes, the Prevention and Public Health Fund, and the Patient-Centered Outcomes Research Institute. Since the ACA’s passage, health system innovation has surged — a dynamic that would have been undermined by a negative Court ruling.

The biggest change involves Medicaid. The ACA required that Medicaid serve nearly all legal residents with incomes below 138% of the federal poverty level. As a result, there is a new inequity in the health system: by 2014, all Americans will have guaranteed access to affordable health insurance except adults with incomes below the poverty level who were previously ineligible for Medicaid (those with incomes between 100 and 138% of the poverty level will be allowed to obtain coverage through insurance exchanges). States have strong economic incentives to expand Medicaid, since the federal government will pay 100% of expansion costs between 2014 and 2016. By 2020, the federal share will drop to no less than 90% — much more generous than the 50 to 83% that the federal government contributes for traditional Medicaid and the Children’s Health Insurance Plan.

The current implementation queue includes writing definitions and rules for private health insurance markets, clarifying rules for determining required “essential health benefits,” explaining how employer-responsibility provisions will be devised, and much more. The ACA is the first U.S. law to attempt comprehensive reform touching nearly every aspect of our health system. The law addresses far more than coverage, including health system quality and efficiency, prevention and wellness, the health care workforce, fraud and abuse, long-term care, biopharmaceuticals, elder abuse and neglect, the Indian Health Service, and other matters.

Encouraging competition among health plans, even if one of them is “public,” will also fail to solve the cost problem. With the exception of highly integrated organizations, such as Kaiser Permanente, health plans have only two tools to control costs: financial disincentives for patients and fee reductions for providers. Acceptable out-of-pocket maximums, however, vitiate economic incentives to restrain use, particularly for expensive care such as inpatient care. Unable to alter provider behavior, health plans primarily try to avoid enrolling people who are likely to need costly care.

Budget Sequestration and the U.S. Health Sector

McDonough J.E.N Engl J Med 2013; 368:1269-1271 http://dx.doi.org/10.1056/NEJMp1303266

In August 2011, in an agreement to raise the nation’s debt ceiling, bipartisan majorities in the House and Senate approved the Budget Control Act of 2011 (BCA) to reduce the deficit by $1.2 trillion between 2013 and 2021. The BCA established a threat of across-the-board cuts, or “sequestration,” if the Joint Select Committee on Deficit Reduction failed to approve, and Congress to enact, alternative reductions. Sequestration became operational on March 1. Of the $1.2 trillion in cuts, $216 billion will be reductions in debt-service payments, and the remaining $984 billion will be split evenly over 9 years at $109 billion per year, and further adjusted and split evenly between cuts to national defense and nondefense functions at $42.667 billion each.

T2.large Adults Ages 19–64 Who Were Uninsured And Underinsured, By Various Characteristics, 2003 And 2007   T3.large uninsured by medicaid eligibility

The $42.667 billion per year in nondefense cuts will not fall equally on all health-related government programs. Nonexempt and nondefense discretionary funding faces reductions of 7.6 to 8.2% in this fiscal year; certain programs such as Medicare and community health centers will have 2% reductions; and certain programs such as Medicaid and the Veterans Health Administration are exempt.

nejmp1303266_t1 Impact of Budget Sequestration on Key Federal Health and Safety Programs,

Impact of Budget Sequestration on Key Federal Health and Safety Programs, Fiscal Year 2013.

http://www.nejm.org/na101/home/literatum/publisher/mms/journals/content/nejm/2013/nejm_2013.368.issue-14/nejmp1303266/20130618/images/small/nejmp1303266_t1.gif

Medicare funding will be cut by 2% ($11.08 billion) through reductions in payments to hospitals, physicians, and other health care providers, as well as insurers participating in Medicare Advantage (Part C). The BCA prohibits cuts affecting premiums for Medicare Parts B and D, cost sharing, Part D subsidies, and Part A trust-fund revenues. The sequestration cuts arrive just as Medicare is beginning to fully implement the savings and cuts required by the Affordable Care Act (ACA), which the Congressional Budget Office estimates will slow Medicare’s rate of growth by $716 billion between 2013 and 2022. The National Institutes of Health (NIH) faces an 8.2% across-the-board reduction for the 7 months remaining in fiscal 2013, equaling cuts of $1.55 billion.

The Centers for Disease Control and Prevention (CDC), which is still recovering from major budget reductions in 2011, anticipates effective reductions of 8 to 10% for the remainder of the year. The American Public Health Association has projected that the reductions could result in 424,000 fewer HIV tests (the CDC funded 3.26 million in 2010) and 50,000 fewer immunizations for adults and children (from a baseline of about 300 million), elimination of tuberculosis programs in 11 states, and shutting down of the National Healthcare Safety Network.

Unaffected for all 9 years of the sequester are most expenses associated with the ACA. Medicaid is exempt, as is funding for its expansion, beginning next January, to all lower-income Americans in states that choose to participate. Also exempt are private insurance subsidies that will be available next January through new health insurance exchanges, because they were designed as refundable tax credits, another BCA-exempt category. Finally, the Children’s Health Insurance Plan, the Supplemental Nutrition Assistance Program, Temporary Assistance to Needy Families, and Supplemental Security Income are all exempt.

Threading the Needle ‹ Medicaid and the 113th Congress

fs310_graph3 leading causes of death by income class worldwideFUSA_INFOGRAPHIC_50-state-medicaid-expansion_rev_06-27-13_FACEBOOKCOVER

Rosenbaum S.N Engl J Med 2012; 367:2368-2369 http://dx.doi.org/10.1056/NEJMp1213901

Medicaid is a veteran of decades of warfare over its size and cost. Nevertheless, the program now plays a vital role in the U.S. health care system and a foundational role in health care reform. The central question, as we approach a major debate over U.S. spending and federal deficits, is how to preserve this role and shield Medicaid from crippling spending reductions. The Budget Control Act, which provides the initial framework for this debate, insulates Medicaid from sequestration. Budgetary protections for Medicaid date to the 1980s, but today’s politics are less tolerant of programs for poor and vulnerable populations. Medicaid is also at a deep political disadvantage. Medicaid is unequaled among federal grant programs: more than 60 million children and adults rely on the program, and it’s projected to grow to 80 million beneficiaries by 2020 if all states adopt the eligibility expansion in the Affordable Care Act (ACA). Medicaid’s cost is driven by high enrollment, not excessive per capita spending.2 As a result, there’s very little money to wring out of Medicaid without shaking its structure in ways that reduce basic coverage. Medicaid is part of the base on which health care reform rests; if it is not expanded per the ACA, the nation will lose its chance at near-universal health insurance coverage, which is essential to achieving systemwide savings and halting a $50 billion annual cost shift to insurers and patients. Deep federal spending reductions could lead states to abandon Medicaid expansion as a result of a confluence of factors —

  • the still-fragile nature of many state economies,
  • the continuing ideological opposition to Medicaid expansion, and
  • the Supreme Court decision to permit states to opt out of such expansion altogether.

Considerable evidence shows its effectiveness: most recently, a study by Sommers et al. documented its positive effects on health and health care. Experts in Medicaid spending also acknowledge the program’s operational efficiencies, achieved by states through the aggressive use of managed care and strict controls on spending for long-term care. Much of the health care that Medicaid beneficiaries receive is furnished through safety-net providers such as community health centers, which are highly efficient and accustomed to operating on tight budgets with only limited access to costly specialty care. Furthermore, Medicaid’s physician payments are substantially lower than those from commercial insurers and Medicare — a disparity that unfortunately limits provider participation even as it helps to keep per capita spending low. Indeed, the CBO has found that insuring the poor through Medicaid will cost 50% less per capita than doing so through tax-subsidized private insurance plans offered through state health insurance exchanges.

nejmp1306051_f1 Projected Growth in Medicare Per Capita Spending, the Consumer Price Index (CPI), and the Medical CPI, 2011–2015

The essential task is to thread the needle by accelerating efficiency reforms in health care payment and organization that, in turn, can generate savings over time while not damaging Medicaid’s role as a pillar of health care reform. Of particular importance is a heightened focus, begun under the ACA, on reforms that emphasize community care for millions of severely disabled children and adults, including patients who are dually enrolled in Medicare and Medicaid and who rely heavily on long-term institutional care.

The Shortfalls of ‘Obamacare’

Wilensky G.R. N Engl J Med 2012; 367:1479-1481 http://dx.doi.org/10.1056/NEJMp1210763

U.S. health care suffers from three major problems: millions of people go without insurance, health care costs are rising at unaffordable rates, and the quality of care is not what it should be. The Affordable Care Act (ACA) primarily addresses the first — and easiest — of these problems by expanding coverage to a substantial number of the uninsured. Solutions to the other two remain aspirations. The ACA’s primary accomplishment is that approximately 30 million previously uninsured people may end up with coverage — about half with subsidized private coverage purchased in the mostly yet-to-be-formed state insurance exchanges and the other half through Medicaid expansions. The law’s most controversial provision remains the individual mandate, which requires people either to have insurance coverage or to pay a penalty. The penalty for not having insurance is very small, particularly for younger people with modest incomes. It would have been smarter to mimic Medicare’s policies: seniors who don’t purchase the voluntary parts of Medicare covering physician services and outpatient prescription drugs during the first year in which they lack comparable coverage must pay a penalty for every month they have gone without coverage whenever they finally do purchase it.

Despite widespread recognition that fee-for-service reimbursement rewards providers for the quantity and complexity of services and encourages fragmentation in care delivery, the ACA retains all the predominantly fee-for-service reimbursement strategies currently used in Medicare. Much of the coverage expansion is financed through Medicare budget savings, which are produced by reducing the fees paid by Medicare to institutional providers such as hospitals, home care agencies, and nursing homes — but using the same perverse reimbursement system currently in place. Reducing payments to institutional providers should not be confused with lowering the cost of providing care.

The ACA also provides Medicare “productivity adjustments,” which assume that inflation adjustments can be reduced over time because institutions will become more productive, whether or not hospitals and other providers actually find ways to increase their productivity. Unless these institutions find ways to reduce costs, lower Medicare reimbursements will force providers to bargain for higher payments from private insurers. And eventually, seniors’ access to services will be threatened. The Medicare actuary expects that 15% of institutional providers will lose money on their Medicare business by 2019, and the proportion will increase to 25% by 2030 — a situation that he calls unsustainable

Most troubling, the ACA contains no reform of the way physicians are paid, which is the most dysfunctional part of the Medicare program. Through the Resource-Based Relative Value Scale, physicians are reimbursed on the basis of service codes, and payment for each physician service is reduced whenever aggregate spending on physician services exceeds a prespecified limit. This system disregards whether clinicians are providing low-cost, high-value care for patients. Given physicians’ key role in providing patient care, it’s impossible to imagine a reformed delivery system without one that rewards them for providing clinically appropriate care efficiently.

What is needed are reforms that create clear financial incentives that promote value over volume, with active engagement by both consumers and the health care sector. Market-friendly reforms require empowering individuals, armed with good information and nondistorting subsidies, to choose the type of Medicare delivery system they want. Being market-friendly means allowing seniors to buy more expensive plans if they wish, by paying the extra cost out of pocket, or to buy coverage in health plans with more tightly structured delivery systems at lower prices if that’s what suits them. 

Financing Graduate Medical Education — Mounting Pressure for Reform

John K. Iglehart N Engl J Med 2012; 366:1562-1563 http:dx.doi.org/10.1056/NEJMp1114236
http://www.nejm.org/doi/full/10.1056/NEJMp1114236

Disparate voices from the White House, a national fiscal commission, Congress, a Medicare advisory body, private foundations, and academic medical leaders are advocating changes to Medicare’s investment in graduate medical education (GME), which currently totals $9.5 billion annually. They offer various prescriptions, including reducing federal support, developing new achievement measures for which GME programs should be held accountable, and seeking independent assessment of the governance and financing of training programs.

The influential GME community has withstood most past efforts to change Medicare’s GME policies. But recognizing today’s more challenging political environment, the Association of American Medical Colleges (AAMC) has begun discussing alternative methods of financing GME that could better align training with the future health care delivery system and address U.S. workforce needs. The association is also examining the influence of student debt on the enrollment of a diverse student body.

When Congress enacted Medicare in 1965, it assigned to the program functions that reached well beyond its mission of financing health care for the elderly. One function was supporting GME, at least until the society at large undertook “to bear such education costs in some other way.” Almost 50 years later, Medicare remains the largest supporter of GME, providing both direct payments to hospitals that cover medical education expenses related to the care of Medicare patients (about $3 billion per year) and an indirect medical education (IME) adjustment to teaching hospitals for the added patient-care costs associated with training (about $6.5 billion).

In its 2013 budget, unveiled on February 13, 2012, the Obama administration proposed reducing Medicare’s IME adjustment by $9.7 billion over 10 years, beginning in 2014, citing a report from the Medicare Payment Advisory Commission (MedPAC) indicating that Medicare’s IME adjustments “significantly exceed the actual added patient care costs these hospitals incur.” The administration also proposed that the secretary of health and human services be granted the authority to assess GME programs’ performance in instilling in residents the necessary skills to promote high-quality health care. Similarly, MedPAC had recommended redirecting about half the IME adjustments ($3.5 billion) into “incentive payments” that GME programs could earn by meeting performance standards. The Obama budget would also eliminate coverage of the IME expenses of free-standing children’s hospitals with pediatric residency programs — which do not treat Medicare patients — reducing their federal support by 66% (to $88 million). Moreover, Congress has revealed its uncertainty over how to change federal workforce policy. In the Affordable Care Act (ACA), Congress emphasized the importance of expanding the primary care workforce. But legislators rejected the AAMC’s call to expand the number of Medicare-funded GME positions by 15% in response to reported physician shortages in some specialties.

On December 21, seven senators — Democrats Michael Bennet (CO), Jeff Bingaman (NM), Mark Udall (CO), and Tom Udall (NM) and Republicans Mike Crapo (ID), Chuck Grassley (IA), and Jon Kyl (AZ) — sent a letter to the Institute of Medicine (IOM) encouraging it to “conduct an independent review of the governance and financing of our system of [GME].” They urged the IOM to explore subjects including accreditation; reimbursement policy; the use of GME to better predict and ensure adequate workforce supply in terms of type of provider, specialty, and demographic mix; GME’s role in care of the underserved; and use of GME to ensure the creation of a workforce with the skills necessary for addressing future health care needs. The senators emphasized their interest “in IOM’s observations about the uneven distribution of GME funding across states based on need and capacity, and how to address this inequity.” In an interview, Bingaman said he initiated the letter for the same reasons he had championed creation of a National Health Care Workforce Commission as part of the ACA: to strengthen the government’s resolve to do “a more credible job of assessing workforce shortages” and because he believes Medicare’s GME policies are “outmoded.”

The priorities cited in the IOM letter parallel some of the recommendations of a group of academic medical leaders who gathered at two conferences underwritten by the Josiah Macy Jr. Foundation. At the first conference, in October 2010, the top recommendation was that “an independent external review of the goals, governance, and financing of the GME system should be undertaken by the Institute of Medicine, or a similar body.”3 George Thibault, president of the Macy Foundation, says the group concluded that “because GME is a public good and is significantly financed with public dollars, the GME system must be accountable to the needs of the public.” Acknowledging that some people in academic medicine “favor a behind-the-scenes discussion of GME reform alternatives,” Thibault noted, “I believe we should be upfront, providing examples of change that could influence the thinking of policymakers.” The foundation awarded the IOM $750,000 — about half the support it needs for the GME study.

Among subjects under discussion are the collection of more data highlighting the importance of the safety-net functions and unique services of academic medical centers and the creation of a long-term vision for GME financing that is more closely aligned with emerging care delivery models, such as accountable care organizations. The association is also revisiting a potential financial model under which all health care payers would explicitly cover GME expenses. Private insurers maintain that they accomplish this implicitly by paying teaching hospitals more for clinical services than they pay most other hospitals. GME leaders think one possibility would be to include the costs of residency training when calculating premium amounts for products sold through health insurance exchanges. Similarly, a recent Carnegie Foundation report asserted that “GME redesign demands . . . a more broad-based, less politicized flow of funds.”

Dr. Darrell Kirch noted, CEO of AAMC, “A significant step forward is the announcement by the ACGME [Accreditation Council for Graduate Medical Education] describing major changes in how the nation’s residency programs will be accredited in the future, putting in place an outcomes-based evaluation system by which new physicians will be measured for their competency in performing the essential tasks necessary for clinical practice in the 21st century.”

Achieving Health Care Reform — How Physicians Can Help

Elliott S. Fisher, M.D., M.P.H., Donald M. Berwick, M.D., M.P.P., and Karen Davis, Ph.D.
N Engl J Med 2009; 360:2495-2497 http://dx.doi.org/10.1056/NEJMp0903923
http://www.nejm.org/doi/full/10.1056/NEJMp0903923

The recent commitment by several major stakeholders — including the American Medical Association — to slowing the growth of health care spending is a promising development. But the controversy about whether the organizations actually agreed to a 1.5-percentage-point reduction in annual spending growth is just one indication that success is still far from assured.

Two threats in particular put reform at risk: conflicting doctrines (regarding the creation of a new public insurance option and government support for comparative-effectiveness studies) and opposition to change among some current stakeholders. In the face of this uncertainty, physicians have a choice: to wait and see what happens or to lead the change our country needs. We’d prefer the latter.

The first level is aims. For health care reform, we propose that physicians, through their advocacy, help lead the country to embrace the so-called triple aim: better experience of care (safe, effective, patient-centered, timely, efficient, and equitable), better health for the population, and lower total per capita costs.

The second level is the design of the care processes that affect the patient — clinical “microsystems.” Health care microsystems are famously unreliable, variable in costs, and often unsafe. Physicians, through their participation in quality-improvement initiatives in their practices and hospitals, can and should lead the needed changes in the systems of care in which they work, to make them safer, more reliable, more patient-centered, and more affordable.

However, neither physicians nor anyone else on the front lines can improve care much on their own. Their most important source of support for improvement is the third level described by the IOM — the health care organizations that house almost all clinical microsystems and can ensure coordination among them. We need organizations large enough to be accountable for the full continuum of patients’ care as well as for achieving the triple aim. We will create a high-performing health care system only if integrated delivery systems become the mainstay of organizational design. Organizations could be virtually integrated, such as networks of independent physicians sharing electronic health records and administrative and clinical support for care management and quality improvement, or structurally integrated, such as multispecialty group practices or staff-model health maintenance organizations. Fostering the development of such accountable care organizations need not be disruptive to patients or providers: almost all physicians already work within natural referral networks that provide the vast majority of care to patients seen by the primary care physicians within the network.

Innovators-Prescription-New-Wave-of-Disruptive-Models-in-Healthcare

The IOM’s fourth level is the environment, which includes the payment, regulatory, legal, and educational systems. On this front, too, we need physician advocacy. The United States cannot achieve the triple aim without health insurance for everyone. Integrated delivery systems that are accountable for populations won’t thrive unless payment systems encourage their development and unless we change the laws and regulations — including proscriptions of gainsharing and anti-kickback rules — that prevent cooperation among health care professionals and organizations.

If stakeholders can agree on such a vision of health care reform, perhaps we could shift our focus from the conflict over whether a new public plan should be created to a more constructive insistence that all health plans, whether public or private, focus on the development of professionally led, integrated systems.

If health care providers and suppliers could actually achieve this reduction in growth rates, the federal government would harvest about $1.1 trillion in savings over the 11-year period — enough, perhaps, to close the deal on affordable health insurance for all. Others would also see savings: $497 billion for employers, $529 billion for state and local governments, and $671 billion for households. One simple way for physicians to start contributing to this goal is by reassessing and scaling back, where appropriate, their use of clinical practices now listed as “overused” by the National Quality Forum’s National Priorities Partnership.

Editor-in-Chief Eric J. Topol, MD, interviews Secretary of Health and Human Services (HHS) Kathleen Sebelius

Medscape

Editor’s Note: On the eve of the first anniversary of the Supreme Court’s ruling to uphold most provisions of the Affordable Care Act (ACA), Medscape Editor-in-Chief Eric J. Topol, MD, questioned Secretary of Health and Human Services (HHS) Kathleen Sebelius about the act’s effect on medical technology, clinical trial participation, genetic testing, primary care, and patient safety.

Introduction

Dr. Topol: We are experiencing a digital revolution in which technological advances are putting healthcare where it should be: in the hands of patients. How is the ACA helping to foster medical innovation?
Secretary Sebelius: A recent New York Times column, “Obamacare’s Other Surprise,”[1] by Thomas L. Friedman, echoes what we’ve been hearing from healthcare providers and innovators: Data that support medical decision-making and collaboration, dovetailing with new tools in the Affordable Care Act, are spurring the innovation necessary to deliver improved healthcare for more people at affordable prices.
Today we are focused on driving a smarter healthcare system with an emphasis on the quality — not quantity — of care. The healthcare law includes many tools to increase transparency, avoid costly mistakes and hospital readmissions, keep patients healthy, and test new payment and care delivery models, like Accountable Care Organizations (ACOs). Health information technology is a critical underpinning to this larger strategy.
In May we reached an important milestone in the adoption of health information technology. More than half of all doctors and other eligible providers, and nearly 80% of hospitals, are using electronic health records (EHRs) to improve care, an increase of at least 200% since 2008. Also in May, we announced a $1 billion challenge to help jump-start innovative projects that test creative ways to deliver high-quality medical care and lower costs to people enrolled in Medicare and Medicaid, following 81 Health Care Innovation Awards that HHS awarded last year.
Dr. Topol: Physicians have long lamented the lack of participation by patients in clinical trials, but the ACA is opening the door for greater participation by allowing patients to keep their health insurance while participating in clinical research. Are patients even aware that this provision now exists? How do you see it affecting clinical trial participation in the future?
Secretary Sebelius: In 2014, thanks to the ACA, insurance companies will no longer be able to deny patients from participating in an approved clinical trial for treatment of cancer or another life-threatening disease or condition, nor can they deny or limit the coverage of routine patient costs for items or services in connection with trial participation. For many patients, access to cutting-edge medicine available through clinical trials can increase their likelihood of survival. This is an important protection for patients that not only could have a life-altering impact, but it’s also one that serves to facilitate participation in research that is critical to expanding our knowledge base and finding cures and treatments for those illnesses that threaten the lives of Americans each day.
Dr. Topol: One of the intentions of the ACA is to increase the primary care workforce. This is critical as we approach 2014, when more Americans than ever will have either private insurance or Medicaid. Have you seen any movement in the primary care workforce? Are there concerns that there aren’t enough clinicians available to meet the forthcoming patient load?
Secretary Sebelius: Primary care providers are critical to ensuring better coordinated care and better health outcomes for all Americans. To meet the health needs of Americans, the Obama Administration has made the recruitment, training, and retention of primary care professionals a top priority.
Together, the ACA, the American Recovery and Reinvestment Act of 2009, and ongoing federal investments in the healthcare workforce have led to significant progress in training new primary care providers — such as physicians, nurse practitioners, and physician assistants — and encouraging primary care providers to practice in underserved areas, including:
Nearly tripling the National Health Service Corps;
Increasing the number of medical residents, nurse practitioners, and physician assistants trained in primary care, including placing over 1500 new primary care providers in underserved areas;
Creating primary care payment incentives for providers; and Redistributing unused residency positions and directing those slots for the training of primary care physicians.
Additionally, the ACA is modernizing the primary care training infrastructure, creating new primary care clinical training opportunities, supporting primary care practice, and improving payment and financial incentives for coordinated care.
Improving Hospital Safety
Dr. Topol: George Orwell once said that the hospital is the antechamber to the tomb. That was written decades ago, and unfortunately there’s still truth to that today. One in 4 hospital patients in America have a problem with medical mistakes, contract hospital-acquired infections, and experience medication errors. The ACA last year began linking Medicare payments to quality of patient care, offering financial incentives to hospitals that improve patient care. How is this working? Have there been any meaningful care improvements over the past year?
Secretary Sebelius: The ACA includes steps to improve the quality of healthcare and, in so doing, lowers costs for taxpayers and patients. This means avoiding costly mistakes and readmissions, keeping patients healthy, rewarding quality instead of quantity, and creating the health information technology infrastructure that enables new payment and delivery models to work. These reforms and investments will build a healthcare system that will ensure quality care for generations to come.
Already we have made significant progress:
Healthcare Spending Is Slowing
Secretary Sebelius: Medicare spending per beneficiary grew just 0.4% per capita in fiscal year 2012, continuing the pattern of very low growth in 2010 and 2011. Medicaid spending per beneficiary also decreased 0.9% in 2011, compared with 0.6% growth in 2010. Average annual increases in family premiums for employer-sponsored insurance were 6.2% from 2004 to 2008, 5.6% from 2009 to 2012, and 4.5% in 2012 alone.
Health Outcomes Are Improving and Adverse Events Are Decreasing
Secretary Sebelius: Several programs tie Medicare reimbursement for hospitals to their readmission rates, when patients have to come back into the hospital within 30 days of being discharged. Additionally, as part of a new ACA initiative, clinicians at some hospitals have reduced their early elective deliveries to close to zero, meaning fewer at-risk newborns and fewer admissions to the NICU.
Providers Are Engaged
Secretary Sebelius: In 2012, we debuted the Medicare Shared Savings Program and the Pioneer Accountable Care Organization Model. These programs encourage providers to invest in redesigning care for higher-quality and more efficient service delivery, without restricting patients’ freedom to go to the Medicare provider of their choice.
Over 250 organizations are participating in Medicare ACOs, serving approximately 4 million, or 8%, of Medicare beneficiaries. As existing ACOs choose to add providers and as more organizations join the program, participation in ACOs is expected to grow. ACOs are estimated to save up to $940 million in the first 4 years.
Bundle with Care ‹ Rethinking Medicare Incentives for Post­Acute Care Services

Feder J. N Engl J Med 2013; 369:400-401

A Medicare payment approach in which savings and risk are shared may achieve a better balance of cost, quality, and access than a system of single bundled payments, at least until our capacity to measure patients’ care needs and outcomes is sufficiently robust.

Healthcare Reform 2014: Mandated Coverage, Insurance Exchanges, and Employer Requirements

3 of 5 in Series: The Essentials of Healthcare Reform
http://www.dummies.com/how-to/content/healthcare-reform-2014-mandated-coverage-insurance.html

The Affordable Care Act federal and state officials are working with leaders in the health and insurance industries to restructure our nation’s healthcare system. That restructuring means most Americans will be required to have health insurance and most businesses will be required to offer it to their employees. It also means the creation of another kind of insurance plan called a health insurance exchange.

The government will require most Americans to have health insurance by 2014. The government has enacted this provision as a way to get healthy people who don’t feel the need to pay for coverage to buy insurance. That way, the healthy people can help fund the cost of people who require more medical care.

Several states filed, and lost, a suit against the federal government saying that it is unconstitutional to make individual citizens to buy health insurance.

If you don’t have coverage and you’re not in one of the groups that is an exception to the rule, you’ll pay a penalty. You may not be required to purchase health insurance if you

  • Face financial hardships.
  • Have been uninsured for less than three months.
  • Have religious objections.
  • Are American Indian.
  • Are a prison inmate.
  • Are an undocumented immigrant.

If you’re penalized, the amount you’ll be fined will go up each year for the first three years. In 2014, you’ll pay $95 or 1 percent of your taxable income, whichever is greater. In 2015, the fine will be $325 or 2 percent of taxable income, and in 2016 the penalty will be $695 or 2.5 percent of income. Each year after 2016, the government will refigure the fine based on a cost-of-living adjustment.

To help you meet the cost of mandated insurance, the government will offer premium credits and cost sharing subsidies if you and your family meet certain income guidelines and if you enroll in one of the new state-run insurance exchanges.

If your income falls between 133 and 400 percent of the federal poverty level (FPL), you could receive premium credits that will lower the maximum amount of premium you have to pay for your coverage.

  • There will be a catastrophic plan for people under 30 and for those who are exempt from mandated coverage.

States don’t have to set up the exchanges. If a state chooses not to, the federal government can come in and create them. States that do opt for exchanges will decide whether they’ll be run by a government or not-for-profit entity.

Health Care Reform — Why So Much Talk and So Little Action?

Victor R. Fuchs, Ph.D
N Engl J Med 2009; 360:208-209 http://dx.doi.org/10.1056/NEJMp0809733
http://www.nejm.org/doi/full/10.1056/NEJMp0809733

First, many organizations and individuals prefer the status quo. This category includes health insurance companies; manufacturers of drugs, medical devices, and medical equipment; companies that employ mostly young, healthy workers and therefore have lower health care costs than they would if required to help subsidize care for the poor and the sick; high-income employees, whose health insurance is heavily subsidized through a tax exemption for the portion of their compensation spent on health insurance; business leaders and others who are ideologically opposed to a larger role of government; highly paid physicians in some surgical and medical specialties; and workers who mistakenly believe that their employment-based insurance is a gift from their employer rather than an offset to their potential take-home pay.

Second, as Niccoló Machiavelli presciently wrote in 1513, “There is nothing more difficult to manage, more dubious to accomplish, nor more doubtful of success . . . than to initiate a new order of things. The reformer has enemies in all those who profit from the old order and only lukewarm defenders in all those who would profit from the new order.”

Third, our country’s political system renders Machiavelli’s Law of Reform particularly relevant in the United States, where many potential “choke points” offer opportunities to stifle change. The problem starts in the primary elections in so-called safe congressional districts, where special-interest money can exert a great deal of influence because of low voter turnout. The fact that Congress has two houses increases the difficulty of passing complex legislation, especially when several committees may claim jurisdiction over portions of a bill. Also, a supermajority of 60% may be needed to force a vote in the filibuster-prone Senate.

Fourth, reformers have failed to unite behind a single approach. Disagreement among reformers has been a major obstacle to substantial reform since early in the last century. According to historian Daniel Hirshfield, “Some saw health insurance primarily as an educational and public health measure, while others argued that it was an economic device to precipitate a needed reorganization of medical practice. . . . Some saw it as a device to save money for all concerned, while others felt sure that it would increase expenditures significantly.” These differences in objectives persist to this day.

Health insurers are opening stores alongside department stores, other typical mall tenants.

Jayne O’Donnell , USA TODAY
 http://www.usatoday.com/story/news/nation/2013/09/12/health-insurance-sales-retail-stores-malls/2789897/

,The new health law known as the Affordable Care Act means most uninsured Americans are required to have insurance beginning March 31 or pay a penalty at tax time in 2015.

Insurers need to sign up as many healthy, younger people as they can to pay for all of the older, sick customers they will be taking on. The law prohibits insurers from denying people insurance because of pre-existing health problems and limits how much more they can charge older than younger people.

So, for the first time, insurers are fiercely competing to attract individual consumers and turning to traditional retail marketing techniques to do so, luring them into stores with special events and using splashy advertising. As any retailer knows, they have the greatest chance of converting shoppers to customers once they have them in their retail locations or on their sites.

The Medical Breakthrough Nobody’s Talking About

Toby Cosgrove, CEO and President at Cleveland Clinic

http://www.linkedin.com/today/post/article/20130912184535-205372152-the-medical-breakthrough-nobody-s-talking-about

The latest medical breakthrough hasn’t gotten much press, but it’s changing medicine even as we speak. It’s the dawning realization that healthcare is not about how many patients you can see, how many tests and procedures you can order, or how much you can charge for these things. The breakthrough is the understanding that healthcare is a value proposition, which means getting patients the right care, at the right time, in the right place. It’s a matter of focusing on outcomes and cost, so that more Americans will start getting what they pay for in healthcare dollars.

Value-based care focuses on two targets: outcomes and cost. Until recently, providers pursued these goals separately, with doctors concentrating on outcomes and the administrators trying to control costs. Value-based care does something different. It works to bring these targets into alignment. The caregivers in a value-based provider work with cost-experts as a team to simultaneously improve outcomes and lower expenses.

Doctors, hospitals and payers are partners in the move to value-based care. The Affordable Care Act includes incentives for providers to improve outcomes and lower costs. But this is one breakthrough that will take time for implementation nationwide. Providers who make the transition early will be rewarded with more satisfied patients, lower expenses and pride in a job well done.

Six-Month Enforcement Delay After Guidance

According to AAMC, the language in the final rule requires that the order to admit a patient be written by a practitioner “who has admitting privileges at the hospital,” something that few residents have as they are not considered members of the hospital’s medical staff.

AAMC said it brought the issue to CMS’s attention during an Open Door Forum call Aug. 15. The agency acknowledged it did not intend to prohibit residents from admitting patients, and said it would be issuing a Q&A. However, AAMC said until the issue can be resolved “to the satisfaction of the teaching hospital community,” CMS should make clear to all contractors that no inpatient admission should be denied because it was ordered by a resident while under the supervision of an attending physician.

AAMC said CMS should delay enforcing the new requirements for at least six months following the release of the guidance so hospitals will have sufficient time to understand the rules, educate physicians and others, and ensure that they have put in place the mechanisms that are needed to comply with the new requirements.

“As short inpatient stays have been a focus of audits by [Recovery Audit Contractors], hospitals feel especially at risk for failure to properly implement CMS requirements,” AAMC said.

The letter is available at http://op.bna.com/hl.nsf/r?Open=nwel-9auqls.

Read Full Post »

Stent Design and Thrombosis:  Bifurcation Intervention, Drug Eluting Stents (DES) and Biodegrable Stents

Curator: Aviva Lev-Ari, PhD, RN

UPDATED 2/8/2014

Reva Completes Drug-Eluting Bioresorbable Stent Trial Enrollment

January 24, 2014
Reva Medical Clinical Trial ReZolve2 Bioresorbable Stent
January 24, 2014 — Reva Medical Inc. has completed enrollment in the clinical trial of the ReZolve2 drug-eluting bioresorbable scaffold. A total of 112 patients from three continents have been enrolled in the trial to provide the data needed to apply for CE marking.

The company anticipates filing a CE mark application before the end of 2014. It plans to report an update on trial data at the Paris Course on Revascularization (EuroPCR) in Paris, France, May 2014.

For more information: http://www.teamreva.com

This article has the following SIX Parts:

Part I: Bifurcation Intervention – Stent Design and Thrombosis

Part II: Biodegradable Polymer DES Reduce Stent Thrombosis Rates vs. Durable Polymer DES

Part III: Stent Flexibility versus Stent Concertina Longitudinal Deformation Effect on Outcomes

Part IV: Stent Thrombosis Through the Generations of Stent Design

Part V: Stent Thrombosis in Randomized Trials of Drug-Eluting Stents: Reappraisal of the Synthesis of Evidence!

Part VI. Duration of Dual Antiplatelet Therapy following Zotarolimus-Eluting Stents and A New Strategy for Discontinuation of Dual Antiplatelet Therapy

Conclusions by Larry H Bernstein, MD, FCAP

 

Part I

Bifurcation Intervention – Stent Design and Thrombosis

 

The 5 Ts of Bifurcation Intervention: Type, Technique, Two Stents, T-Stenting, Trials

Ron Waksman, MD, FACC; Laurent Bonello, MD

Editorials published in JACC: Cardiovascular Interventions reflect the views of the authors and do not necessarily represent the views of JACC: Cardiovascular Interventions or the American College of Cardiology.

J Am Coll Cardiol Intv. 2008;1(4):366-368. doi:10.1016/j.jcin.2008.06.006

http://interventions.onlinejacc.org/article.aspx?articleid=1110233

Bifurcation, the division of an artery into 2 branches, is a common anatomy feature of the human coronary tree and is recognized as a common site for atherosclerotic plaque buildup due to the differences in coronary flow, turbulence, and shear stress at the site of the bifurcation. The prevalence of bifurcation stenosis in the human coronary tree is reported to be between 15% to 20% of all interventions and is considered complex and challenging for percutaneous intervention.

Numerous techniques and devices have been proposed to address the treatment of bifurcation lesions: balloon angioplasty, metallic stents, drug-eluting stents (DES), newly designed stents with dedicated access to the side branch, and full bifurcated stents. Clearly, the interest in the treatment of bifurcation stenting has increased with the availability to significantly reduce the recurrence rate, but this was associated with the increasing fear of stent thrombosis. Despite this extensive body of work and the latest innovations of 2008, there is not a “one size fits all” solution to the bifurcation puzzle, while the optimal percutaneous coronary intervention technique remains undetermined.

In this issue of JACC: Cardiovascular Interventions, Routledge et al. (1) present 2-year outcome data of 477 patients treated for bifurcation coronary disease with provisional side branch T-stenting using DES, and claim a systematic approach feasible for 90% of the patients, with acceptable efficacy and safety profiles. This editorial is written in response to this provocative study and will cover the 5 Ts of bifurcation stenting: Type of bifurcation, Techniques, Two stents versus one, T-stenting, and Trial design.

Types Of Bifurcation

Part of the complexity in treating bifurcation lesions and applying technique standardization is in regard to the numerous anatomic patterns of bifurcation stenosis and the lack of consistent, reliable methodology. Further, the variations in anatomy, angulations, and location of the disease within the bifurcation have led to the development of numerous classifications of bifurcation lesions, with differentiation between “true” bifurcation (both the main and the branch are diseased) and “false” bifurcation (either the main or the branch is disease) based on angiography. The most popular and intuitive classification is that of Medina et al. (2), which identifies at least 7 types of bifurcation involving the proximal main branch, the distal main branch, and the side branch, with different variations. If we add this to the classification of the various potential angulations between the main and the side branches, the sizes of the parent vessel and the side branch, and the different potential morphologies of the diseased segment (calcification, fibrosis, and so on), we can identify nearly endless anatomic and morphologic configurations of bifurcations types (3).

Technique

2 stents versus 1

Numerous techniques have been proposed for the treatment of bifurcation lesions. The first decision that the operator must make is whether the procedure will involve 1 or 2 stents. The most important information relates to the size of the side branch and the degree of the disease in this branch. Or do we really care about the side branch? Initially, the thought of using 2 stents for all bifurcated lesions was appealing because this approach usually resulted in an optimal angiographic success rate. Among the most popular techniques that employed the use of 2 stents are the culotte, crush, V-stenting, T-stenting, and simultaneous kissing stents (4). However, after numerous reports of high rates of late complications, including an increase in stent thrombosis and restenosis frequency, systematical use of 2 stents did not live up to expectations (5–8). These poor outcomes were observed regardless of the technique used and thus discouraged the liberal use of 2 stents. Therefore, the provisional strategy gained ground: try 1 stent first, and, if the result is not acceptable (dissection, impaired lumen, or flow of the other branch), use a second stent for the side branch. The superiority of such a provisional approach over a 2-stent technique was confirmed by the Nordic Bifurcation study (9). The results of this study had operators favoring the provisional rather than the 2-stent approach. However, many questions still remain regarding this approach: can we predict which bifurcation will require 2, rather than 1 stent? In how many patients is the provisional approach feasible? If a second stent is required, what then is the optimal technique for implantation of the second stent? Is provisional stenting still superior to the 2-stent approach with the new generation of stents available? And lastly, are the latest technique modifications, including pre- and post-kissing, clinically beneficial?

The present study demonstrated that provisional stenting is feasible in 90% of all patients, and those who received a second stent in the side branch, 28%, had similar long-term outcomes as those treated with 1 stent. The outcome of this study is similar to that of the Nordic Bifurcation study, which observed no difference in outcomes at 6 months’ follow-up between 1 and 2 stents (9). Finally, the latest Nordic Bifurcation Stent Technique study, comparing the culotte and crush techniques, reported low rates of angiographic restenosis and major adverse cardiac events for both techniques (10), with similar angiographic and clinical outcomes as the provisional approach with T-stenting reported in the Routledge et al. study (1). This leaves us with the question of whether, in 2008, provisional stenting is still superior to 2 stents when an improved technique is applied and new-generation stents are used?

T-stenting

Use of the provisional T-stenting technique is gaining interest because of its simplicity and subsequent reports of good mid-term outcomes (11–13). As illustrated in the present report by Routledge et al. (1), it is feasible in a large majority of patients and is associated with low rates of recurrent events during long-term follow-up. In the past, the technique was described to resolve dissections of a side branch (8) or as a new technique for the use of 2 stents for the treatment of bifurcation lesions (11). In the present study, the authors used provisional T-stenting as the default technique. From a technical point of view, provisional T-stenting offers several advantages compared with other bifurcation techniques: it is simple to perform in most cases, and it limits the need for a second stent, as illustrated by the low rate of stenting in the side branch in the present study. One technical aspect of the procedure remains in question: is kissing post-procedure mandatory in the provisional T-stenting approach with 1 or 2 stents? Bench testing observed that the final kissing balloon may have several interesting advantages: it opens the stent cells to the side branch, it allows the side branch ostium to be at least partially covered by stent struts, and it prevents the main branch stent from becoming deformed by side branch dilation. Further, in previous studies involving crush stenting, kissing balloon was shown to be critical in preventing restenosis (14). Nevertheless, the clinical impact of a final kissing balloon in provisional T-stenting must be established in future trials. Several limitations should be considered with T-stenting: it is not applicable for all lesions, it is dependent on the bifurcation angle and cannot be applied to angles <40°; the second stent, if needed, may not be able to fully cover the ostium, which will result in switching to a mini-crush technique, and like other techniques, there is a learning curve. Nevertheless, among today’s available options, the provisional T-stenting technique seems to be the simplest and is associated with favorable long-term outcomes.

Table 1 Comparison of Bifurcation Studies in the DES Era

Bifurcation stenting continues to challenge the interventional cardiologist. Despite the recent literature, including the present manuscript, there is a lack of consensus on an array of important issues, such as: Which branches deserve protection? Should provisional stenting be the default strategy of bifurcation stenting? Should we always pre-dilate the side branch? And if 2 stents are required, which technique would be the best? Is kissing always mandatory for both branches? Are DES more thrombogenic? And finally, how will the special dedicated bifurcated stents be integrated into current practice? With further trials and perhaps the sixth T in bifurcation stenting (Time), the answers to these important questions will be answered.

References

1 Routledge  H.C., Morice  M.-C., Lefèvre  T.; 2-year outcome of patients treated for bifurcation coronary disease with provisional side branch T-stenting using drug-eluting stents. J Am Coll Cardiol Intv. 1 2008:358-365.

2 Medina  A., Suárez de Lezo  J., Pan  M.; A new classification of coronary bifurcation lesions. Rev Esp Cardiol. 59 2006:183

3 Thomas  M., Hildick-Smith  D., Louvard  Y.; Percutaneous coronary intervention for bifurcation disease. A consensus view from the first meeting of the European bifurcation club. Euro Intervention. 2 2006:149-153.

4 Louvard  I., Lefevre  T., Morice  M.C.; Percutaneous coronary intervention for bifurcation coronary disease. Heart. 90 2004:713-722.

5 Iakovou  I., Schmidt  T., Bonizzoni  E.; Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA. 293 2005:2126-2130.

6 Finn  A.V., Kolodgie  F.D., Harnek  J.; Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents. Circulation. 112 2005:270-278.

7 Daemen  J., Wenaweser  P., Tsuchida  K.; Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: data from a large two-institutional cohort study. Lancet. 369 2007:667-678.

8 Carrie  D., Karouny  E., Chouairi  S., Puel  J.; “T” shaped stent placement: a technique for the treatment of dissected bifurcation lesions. Cathet Cardiovasc Diagn. 37 1996:311-313.

9 Steigen  T.K., Maeng  M., Wiseth  R.; Randomized study on simple versus complex stenting of coronary artery bifurcation lesions: the Nordic Bifurcation study. Circulation. 114 2006:1955-1961.

10 Gunnes P, Niemela M, Kervinen K, et al, for the Nordic-Baltic PCI Study Group. Eight months angiographic follow-up in patients randomized to crush or culotte stenting of coronary artery bifurcation lesions. The Nordic Bifurcation Stent Technique study. Paper presented at: ACC 2008 Late Breaking Trials; April 1, 2008; Chicago, IL.

11 Palvakis  G., de Man  F., Hamer  B., Doevendas  P., Stella  P.R.; Registry of new technique on coronary bifurcation lesions: the Utrech-“T” experience. Euro Intervention. 3 2007:262-268.

12 Pan  M., Suárez de Lezo  J., Medina  A.; Drug-eluting stents for the treatment of bifurcation lesions: a randomized comparison between paclitaxel and sirolimus stents. Am Heart J. 153 2007:15-17.

13 Ormiston  J.A., Webster  M.W., El Jack  S.; Drug-eluting stents for coronary bifurcations: bench testing of provisional side-branch strategies. Catheter Cardiovasc Interv. 67 2006:49-55.

14 Ge  L., Airoldi  F., Iakovou  I.; Clinical and angiographic outcome after implantation of drug-eluting stents in bifurcation lesions with the crush stent technique: importance of final kissing balloon post-dilation. J Am Coll Cardiol. 46 2005:613-620.

15 Hoye  A., Iakovou  I., Ge  L.; Long-term outcomes after stenting of bifurcation lesions with the “crush” technique: predictors of an adverse outcome. J Am Coll Cardiol. 47 2006:1949-1958.

16 Sharma  S.K.; Simultaneous kissing drug-eluting stent technique for percutaneous treatment of bifurcation lesions in large-size vessels. Catheter Cardiovasc Interv. 65 2005:10-16.

17 Moussa  I., Costa  R.A., Leon  M.B.; A prospective registry to evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions using the “crush technique”. Am J Cardiol. 97 2006:1317-1321.

18 Yanagi  D., Shirai  K., Takamiya  Y.; Results of provisional stenting with a sirolimus-eluting stent for bifurcation lesion: multicenter study in Japan. J Cardiol. 51 2008:89-94.

19 Di Mario  C., Morici  N., Godino  C.; Predictors of restenosis after treatment of bifurcational lesions with paclitaxel eluting stents: a multicenter prospective registry of 150 consecutive patients. Catheter Cardiovasc Interv. 69 2007:416-424.

20 Tsuchida  K., Colombo  A., Lefèvre  T.; The clinical outcome of percutaneous treatment of bifurcation lesions in multivessel coronary artery disease with the sirolimus-eluting stent: insights from the Arterial Revascularization Therapies Study part II (ARTS II). Eur Heart J. 28 2007:433-442.

SOURCE

J Am Coll Cardiol Intv. 2008;1(4):366-368. doi:10.1016/j.jcin.2008.06.006

http://interventions.onlinejacc.org/article.aspx?articleid=1110233

 

Bifurcation Stenting

David Hildick-Smith, MD

Consultant Cardiologist and Director of Cardiac Research

Brighton-Sussex University Hospital NHS Trust

Brighton, UK

Slide 1

Bifurcation stenting and its various ramifications in the modern cardiology world. The objectives of this presentation are to talk about some of the difficulties of bifurcation stenting, to summarize the recent study data, and to talk a little bit about dedicated stent systems, as well.

Dedicated Bifurcation Stent Systems – Main types:

• Side branch facilitation

• Side branch stenting incorporated

• Main branch stenting with enhanced access

• True dedicated systems

Slide 32

So we then have the issue of dedicated stent systems. Are they the answer to some of these questions? Are they going to bail us out of these difficult geometric issues of bifurcations? There are a number of dedicated stent systems in development and available at the moment, and they fall into a few different groups. There are systems which simply facilitate side branch access. There are systems which actually incorporate side branch stenting as the primary philosophy. There are those which are essentially a main branch stent with enhanced access. And then there are the truly dedicated systems.

Bifurcation Stenting: Should You Keep it Simple

You Keep it Simple

Facilitation

Increasing success of provisional T

Slide 33

If we look at the facilitation group, there are stent systems available where there’s a wire that is integral to the balloon system, and will perhaps then facilitate getting into the side branch, and may certainly facilitate making sure that you are,

Side Branch Ostial Coverage Stents:

• Scaffold side branch ostium

• Allow subsequent main vessel stenting

The side branch ostial coverage stents are intended to scaffold the side branch and retain main vessel stenting capabilities. There are a couple of stents of this nature on the market at the moment which are undergoing clinical trials to see their general applicability.

Main Vessel Enhanced Access Stents

•Pop-up/expand into side vessel

•Improve subsequent or immediate access to side branch

Slide 35

The next group is the main vessel enhanced access stents, which, either through a pop-up mechanism with mechanical scaffolding of the side branch ostium, or with a proximal stent which is self-expanding, enhance the access to the side branch, so that you have both immediate access and subsequent access. Which is one of the things that people worry about in this situation, which is, what happens if you have to come back to that side branch vessel a few months later? Will you be able to gain access to it? So these tools may have a role there.

True Dedicated Bifurcation Stent

Stenting of both branches

Slide 36

The fourth group is the true dedicated bifurcation stent. These are clearly the most useful, but of course, mechanically and from an engineering point of view, the most difficult to create and make work. They will certainly have a potential role in bifurcation stenting, but there’s a little  way to go before they could be used in a wide manner.

Slide 37

The dedicated systems, while most are quite ingenious, unfortunately most will not survive in their current format. But the true dedicated bifurcation stent will certainly have a role in the left main. And, as we come back increasingly from these bifurcations to the left main and get a mandate to be able to treat that, this is an area where there will be a significant place for dedicated bifurcation stent systems.

Conclusions

• Bifurcations remain troublesome

• Provisional T stenting is the gold standard

• Subsets of bifurcations require complex strategies

• Large side branches

• Longer ostial disease

• Current complex strategies fail us

• Crush fails more than culotte

• Dedicated devices will have a role

• Large bifurcations in main coronary tree

• Left main

Slide 38

In conclusion, bifurcation stenting is still a troublesome area. Provisional T stenting is the gold standard approach across the board, but we mustn’t forget that there may well be, and I believe there are, subsets of bifurcations which do require a complex strategy. These are the ones with large side branches and significant length of disease at the ostium of that side branch. The current complex strategies do fail from a mechanical point of view, and in that respect crush fails more than culotte. Although it’s a difficult time for dedicated devices at the moment, I think they will have a role, particularly in large bifurcations in the main coronary tree and, most particularly of all, in the left main stem.

SOURCE

http://www.theheart.org/documents/satellite_programs/intervsurgery/913801/BifurcationStenting_REVISED_FINAL.pdf

Part II

Biodegradable Polymer DES Reduce Stent Thrombosis Rates vs. Durable Polymer DES

March 27, 2012 — Biodegradable polymer drug-eluting stents (DES) provide better long-term safety and efficacy than durable polymer DES, according to findings from an analysis of three major clinical trials —

  • ISAR-TEST 3,
  • ISAR-TEST 4 and
  • LEADERS.

The data were presented at at the American College of Cardiology’s 61st Annual Scientific Session. The findings provide the first combined long-term data on the comparison between biodegradable polymer DES and durable polymer DES. Designed to improve long-term clinical outcomes while also shortening healing time, biodegradable polymer DES are a new generation of DES that have undergone little research and thus have yet to substantiate its claims. The three analyzed studies showed that after four years, use of biodegradable polymer DES resulted in

  • lower rates of target lesion revascularization,
  • definite stent thrombosis and
  • cardiac death and
  • heart attack than durable polymer DES.

“Because it is often difficult to design individual trials to test for differences in rarely occurring adverse events [like stent clotting], we pooled the data from the three largest trials to see if any differences between the two stent types could be seen,” said co-lead investigator Robert A. Byrne, M.B., B.Ch., Ph.D., a cardiologist at Deutsches Herzzentrum in Munich, Germany. “In addition, by including surveillance out to four years, this helped us better capture the differences between the two stents, as benefit was expected to first emerge with long-term follow-up.”

Among all three analyzed trials, 2,358 patients were randomly assigned to angioplasty with a biodegradable polymer DES (sirolimus-eluting = 1,501; biolimus-eluting = 857), while 1,704 patients were treated with a durable polymer SES (all sirolimus-eluting).

At the four-year follow-up point, the researchers found that the risk of target lesion revascularization (the study’s primary efficacy endpoint) was significantly lower among those patients treated with a biodegradable polymer DES than for those treated with a durable polymer DES (hazard ratio [HR] 0.82, 95 percent confidence interval [CI] 0.68-0.98, P=0.029). In addition, the risk of having a blood clot, called stent thrombosis (the study’s primary safety endpoint), was also significantly lower for those patients treated with a biodegradable polymer DES compared to those treated with a durable polymer DES (HR 0.56, 95 percent CI 0.35-0.90, P=0.015). This was driven by a lower risk of very late stent thrombosis (clots occurring more than one year after angioplasty) for the biodegradable polymer group (HR 0.22, 95 percent CI 0.08-0.61, P=0.004).

Furthermore, the incidence of heart attack late after stenting was lower for patients treated with biodegradable polymer versus durable polymer stents (HR 0.59, 95 percent CI 0.73-0.95, P=0.031).

While the arrival of DES has allowed interventionalists to provide treatment for more complex patients, concerns have arisen about the stents’ long-term safety, particularly concerning stent thrombosis. As a result, the polymer coating on the first-generation stents was targeted as an area for improvement. Specifically, the durable polymer remains in the coronary artery wall beyond the time when its useful function is served. This may cause delayed healing and a hypersensitivity reaction, leading to inflammation and stent thrombosis.

As a potential solution to these problems, new-generation stents with a bioabsorbable polymer were created. This polymer, which fully degrades and leaves a bare-metal stent in place, has been suggested to shorten healing time and cause less inflammation and subsequent stent thrombosis.

“These findings show that biodegradable polymer DES can provide better long-term safety and efficacy,” said Byrne. “This advantage, coupled with a shortened healing time compared with durable polymer DES, means that biodegradable polymer stents look to become an important tool for the interventional cardiologist in everyday practice.”

The current analysis was industry independent, supported in part by a grant from the Swiss National Science Foundation, and conducted at the ISAR Research Center in Munich, Germany, and the Clinical Trials Unit in Bern, Switzerland.

This study was simultaneously published in the European Heart Journal and was released online at the time of presentation.

The results offer a promising outlook for Boston Scientific’s Synergy DES, now in development. It uses the same platform stent as the Ion and Promus, but instead of a duable polymer it uses abluminal biodegradable polymer containing everolimus. The company presented its first-in-man study at TCT 2011 and hopes to begin its EVOLVE II U.S. Food and Drug Administration (FDA) investigational decive exemption trial later this year.

For more information: www.acc.org

Biosensensors BioMatrix Flex was among the stents included in this study. It uses an abluminal, biodegradable polymer as a carrier for its BA9 drug.

http://www.dicardiology.com/article/biodegradable-polymer-des-reduce-stent-thrombosis-rates

First Patient Enrolled in Dissolving Drug-Polymer Coronary Stent Trial

February 21, 2011 – The first patient has been enrolled the DESSOLVE II study to support CE mark for a coronary stent that uses a bioresorbable drug polymer. The MiStent drug-eluting coronary stent system (MiStent DES), by Micell Technologies.

The trial involves treatment of patients with de novo lesions in the native coronary arteries. Stefan Verheye, M.D., Ph.D. at Middelheim Hospital, Antwerp, Belgium enrolled the first patient in the study.

The MiStent DES employs supercritical fluid technology, which applies a precisely controlled absorbable polymer – active drug (sirolimus) matrix onto a cobalt-chromium stent. The polymer dissolves and releases the drug into the surrounding tissue in a controlled manner, designed to optimize dosing of the drug throughout the affected artery. In preclinical trials, the drug completely elutes and the polymer is eliminated from the stent within 45 to 60 days in-vivo, resulting in a bare-metal stent.

DESSOLVE II is a prospective, controlled, 2:1 unbalanced randomized, multicenter study of approximately 270 patients. Patients will be enrolled at 26 clinical sites in Europe, New Zealand and Australia. Candidates for the trial are patients with documented stable or unstable angina pectoris or ischemia. The primary endpoint is superiority of MiStent DES in minimizing in-stent late lumen loss at nine months, compared to Medtronic’s Endeavor DES, as measured with angiography in treated de-novo lesions ranging in diameter from 2.5 to 3.5 mm and amenable to treatment with a maximum 23 mm long stent.

Along with secondary clinical endpoints such as major adverse cardiac events and revascularization rates, the extent of stent coverage and re-endothelialization, via optical coherence tomography (OCT), and endothelial function (vasomotor response) will be evaluated in a subgroup of patients at nine months.

“Drug-eluting stents have significantly improved and expanded our ability to treat coronary atherosclerotic lesions compared to bare-metal stents,” said William Wijns, M.D., Cardiovascular Center, Aalst, Belgium, and principal investigator of the study. “However, cardiologists are still looking for options to improve safety and outcomes. The MiStent DES may address some of these issues directly. Based on recent GLP animal data, the polymer and drug are gone from the stent within 45 to 60 days. This may reduce the risk of late-stent thrombosis related to long-term exposure to DES nonerodible polymers. Given the relatively short residence time of polymer on the stent, MiStent DES may allow for a shorter duration of dual antiplatelet therapy and be a safer choice for noncompliant patients. These performance-enhancing properties are what interventional cardiologists are looking for in a new drug-eluting stent.”

For more information: www.micell.com

http://www.dicardiology.com/article/first-patient-enrolled-dissolving-drug-polymer-coronary-stent-trial

 

Part III

Stent Flexibility versus Stent Concertina Effect

 

Stent flexibility versus concertina effect: mechanism of an unpleasant trade-off in stent design and its implications for stent selection in the cath-lab.

Foin N, Di Mario C, Francis DP, Davies JE.

Abstract

The “concertina effect”, longitudinal deformation of the proximal segments of a deployed stent when force is applied from a guide catheter or other equipment, is a recently recognised problem which seems to particularly affect more recent stent designs. Until now, flexibility and deliverability have been paramount aims in stent design. Developments have focused on optimizing these features which are commonly evaluated by clinicians and demanded by regulatory bodies. Contemporary stent designs now provide high flexibility by reducing the number of connecting links between stent segments and by allowing the connecting links to easily change their length. These design evolutions may, however, simultaneously reduce longitudinal strength and have the unintended effect of inducing some risk of longitudinal compression of the stent (the “concertina effect”) during difficult clinical cases. Progress in stent design and elimination of restenosis by drug coating has improved PCI outcome and enabled new applications. Here we discuss design trade-offs that shaped evolution and improvement in stent design, from early bare metal designs to the latest generation of drug eluting stent (DES) platforms. Longitudinal strength was not recognised as a critical parameter by clinicians or regulators until recently. Measurements, only now becoming publically available, seem to confirm vulnerability of some modern designs to longitudinal deformation. Clinicians could be more guarded in their assumption that changes in technology are beneficial in all clinical situations. Sometimes a silent trade-off may have taken place, adopting choices that are favourable for the vast majority of patients but exposing a few patients to unintended hazard.

Int J Cardiol. 2013 Apr 15;164(3):259-61. doi: 10.1016/j.ijcard.2012.09.143. Epub 2012 Oct 22.

http://www.ncbi.nlm.nih.gov/pubmed/23084111

 

Stent “Concertina:” Stent Design Does Matter

On-Hing Kwok, MBBS

From the Cardiac Catheterization & Intervention Center, Hong Kong Sanatorium & Hospital, Happy Valley, Hong Kong.

ABSTRACT: The development of modern coronary stent platforms has transformed the landscape of interventional cardiology. Contemporary coronary stents are much more deliverable than older-generation stents. However, longitudinal deformation has emerged as a “new” complication in modern coronary stent platforms. Although most reported cases of longitudinal stent deformation involve mechanical or technical mishaps, it appears that it is more frequently associated with a particular stent design: the “offset peak-to-peak” stent design. This review summarizes the latest data around stent performance. Within this context, two clinical cases where longitudinal deformation was observed in the absence of any mechanical mishaps are also presented. Collectively, this evidence suggests that stent design may be a major determinant of stent performance.

SOURCE

Journal Cardiology, Volume 25 – Issue 6 – June 2013

Key words: longitudinal deformation, stent design, stent concertina, drug-eluting stent

Over the past decades, stent design and material has undergone significant evolution. The introduction of the drug-eluting stent (DES) has also made “drug delivery” another major determinant in modern stent design.1

Coronary stent design. The majority of early coronary stents were made of stainless steel. These designs were associated with variable basic manufacture, cell geometry, and strut thickness.2 Use of alloys such as cobalt chromium and platinum chromium has enabled stents to have thinner struts, while maintaining strength and radioopacity.3 Thin-strut stents improve deliverability and conformability. However, there is limited evidence suggesting that thinner struts may result in less vessel wall damage and hence less risk of restenosis.4-6 Although thin-strut DESs have never been shown to have lower restenosis rates than thick-strut DESs, the trend of thinner strut platforms has triggered innovative designs to maintain stent radial strength. The development of longer, thinner, more flexible, and easier-to-deliver stent platforms made percutaneous coronary intervention (PCI) possible even in the most tortuous anatomy and calcified vessels.7 However, longitudinal stent strength may be compromised with these modern designs.3 Stent design requires careful consideration of several performance characteristics, including crimped and expanded stent flexibility, shortening upon expansion, trackability, scaffolding, radioopacity, longitudinal strength, radial strength, and recoil.8

Stent longitudinal flexibility and deliverability prior to deployment, and vessel conformability after deployment, are widely dependent on the number, orientation, shape, thickness, and material of the crests and links.9 These parameters also determine the longitudinal strength of the stent, defined as maintenance of intact stent architecture upon exposure to compressing or elongating forces.9 Alteration of any one feature of a stent platform will undoubtedly impact other aspects of stent performance and may result in clinical complications. For instance, thinner struts improve deliverability, but reduce radio-opacity of the cobalt chromium stents. In addition, reduction of the number of fixed links between cells or alteration of their geometry may enhance flexibility and conformability, but as a consequence may compromise longitudinal strength.7

Although stent flexibility may be influenced by a variety of factors, it has been shown that stent longitudinal integrity, defined by the number of links between hoops, correlates with stent stiffness. In addition, the alignment of the links with the long axis of the stent may also be an important factor for longitudinal integrity.9

Architectural design differences are major factors affecting resistance against longitudinal compression. The peak-to-peak or peak-to-valley strut architectures of platforms result in variation between the longitudinal stiffness and strength of stents. It is highly likely that the occurrence of longitudinal deformation is dependent on a particular stent design.10

Longitudinal stent deformation. Until recently, the longitudinal strength of coronary stents has never been considered a standard parameter of stent performance. However, recent evidence identified longitudinal compression, or postdeployment stent shortening, as a newly observed complication. Longitudinal stent deformation is defined as the distortion or shortening of a stent in the longitudinal axis following successful stent deployment.3 This phenomenon describes the effect of a longitudinal compression force on the stent rings, causing them to nest or concertinate.8 

PCI procedures involve multiple and complex techniques that may increase the risk for longitudinal stent compression. These include the use of extra-support guide catheters, aggressive guide catheter manipulation (deep-seat), mother and child catheter systems, multiple balloon postdilations, bifurcation stent techniques, and adjunctive devices such as intravascular ultrasound (IVUS), distal protection devices, etc.7 In a clinical setting, longitudinal compression may occur in various situations (Table 1),8 and it may simply represent an angiographic detection of an exceptional PCI complication. Protrusion of struts into the lumen and extensive malapposition of struts due to longitudinal deformation may result in disruption of flow and increasing the risk of stent thrombosis. Moreover, longitudinal deformation of a DES may result in uneven drug delivery and increase the risk for in-stent restenosis (ISR).9

Clinical reports of longitudinal deformation. Hanratty and Walsh recently described 3 cases where longitudinal compression of a previously deployed stent resulted in stent deformation. Two cases were detected angiographically, while 1 was detected on adjunctive imaging. The complication was first reported with the Promus Element (Boston Scientific) platform. However, Hanratty and Walsh noted that this phenomenon has since been observed with all modern DES platforms. They concluded that such deformation could potentially result in a suboptimal technical result for the medium- to long-term and increase the risk for stent thrombosis and ISR if left undetected.7

References

1. Htay T, Liu MW. Drug-eluting stent: a review and update. Vasc Health Risk Manag. 2005;1(4):263-276.

2. Colombo A, Stankovic G, Moses JW. Selection of coronary stents. J Am Coll Cardiol. 2002;40(6):1021-1033.

3. Williams PD, Mamas MM, Morgan K, et al. Longitudinal stent deformation — a retrospective analysis of frequency and mechanisms. EuroIntervention. 2012;8(2):267-274. Epub AOP 2011.

4. Pache J, Kastrati A, Mehilli J, et al. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial. J Am Coll Cardiol. 2003;41(8):1283-1288.

5. Moreno R, Jimenez-Valero S, Sanchez-Recalde A. Periprocedural (30-day) risk of myocardial infarction after drug-eluting coronary stent implantation: a meta-analysis comparing cobalt-chromium and stainless steel drug-eluting coronary stents. EuroIntervention. 2011;6(8):1003-1010.

6. Kastrati A, Mehilli J, Dirschinger J, et al. Strut thickness effect on restenosis outcome (ISAR-STEREO) trial. Circulation. 2001;103(23):2816-2821.

7. Hanratty CG, Walsh SJ. Longitudinal compression: a “new” complication with model coronary stent platforms — a time to think beyond deliverability. EuroIntervention. 2011;7(7):872-877. Epub AOP 2011.

8. Prabhu S, Schikorr T, Mahmoud T, Jacobs J, Potgieter A, Simonton C. Engineering assessment of the longitudinal compression behavior of contemporary coronary stents. EuroIntervention. 2012;8(2):275-281.

9. Ormiston JA, Webber B, Webster MWI. Stent longitudinal integrity — bench insights into a clinical problem. JACC Cardiovasc Interv. 2011;4(12):1310-1317.

10. Mortier P, De Beule M. Stent design back in the picture: an engineering perspective on longitudinal stent compression. EuroIntervention. 2011;7(7):773-776.

11. Stone GW, Teirstein PS, Meredith IT, et al; PLATINUM Trial Investigators. A prospective randomised evaluation of a novel everolimus-eluting coronary stent: the PLATINUM trial. J Am Coll Cardiol. 2011;57(16):1700-1708.

12. Pitney M, Pitney K, Jepson N, et al. Major stent deformation/pseudofracture of 7 Crown Endeavor/Micro Driver stent platform: incidence and causative factors. EuroIntervention. 2011;7(2):256-262.

13. Finet G, Rioufol G. Coronary stent longitudinal deformation by compression: is this a new global stent failure, a specific failure of a particular stent design, or simply an angiographic detection of an exceptional complication. Eurointervention. 2012;8(2):177-181. Epub AOP 2011.

Disclosure: The author has completed and returned the ICMJE Form for Disclosure of Potential Conflicts of Interest. The author reports no conflicts of interest regarding the content herein.

Manuscript submitted September 12, 2012, provisional acceptance given October 31, 2012, final version accepted January 14, 2013.

Address for correspondence: On-Hing Kwok, MBBS, FRCP, FACC, FSCAI, Cardiology Center, 6/F Li Shu Fan Building, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong. Email: vohkwok@hksh.com

SOURCE

J INVASIVE CARDIOL 2013;25(6):E114-E119

 

Part IV

Stent Thrombosis Through the Generations of Stent Design

A recent retrospective analysis provided further valuable information on the frequency and mechanisms of longitudinal stent deformation. The study involved 4455 interventional cases performed during a 4-year period. Stent deformation occurred in a total of 9 cases (0.2%) and affected 0.097% of stents deployed. In 6 cases, the Promus Element stent was involved, and there was 1 case each involving Endeavor (Medtronic), Biomatrix (Biosensors Interventional Technologies), and Taxus Liberté (Boston Scientific) stents. Stent deformation varied from 0% in several stent types to 0.86% in the case of Promus Element.3 It was virtually unseen in the Cypher and Xience (Abbott Vascular) platforms. Longitudinal stent deformation is probably not a “class effect,” but highly dependent on a particular stent design.

http://www.invasivecardiology.com/articles/stent-“concertina”-stent-design-does-matter

Author(s): 

Lawrence Rajan, MD and David J. Moliterno, MD

From the Gill Heart Institute and Division of Cardiovascular Medicine, University of Kentucky, Lexington, Kentucky.

Stent thrombosis (ST), while infrequent, remains a dreaded complication of percutaneous coronary revascularization because of the associated rates of

  • major myocardial infarction (60%-70%) and
  • early mortality (20%-25%).1

As coronary stents became more widely used in clinical practice during the late 1990s to treat acute vessel closure and to reduce restenosis, the emergence of ST redirected the efforts of the cardiology community to mitigate or eliminate this potentially catastrophic event. Advances in

  • stent design and strut thinness,
  • the advent of drug-eluting stent (DES) options, and
  • more potent antithrombotic therapy

have been substantial influences on ST.

  • DESs have been associated with higher ST rates as compared to their bare-metal counterparts, particularly when utilized among high-risk groups and high-risk lesions.

More recently, early meta-analyses of smaller studies have suggested

  • reduced ST rates with newer-generation DESs versus prior versions.2 Similarly, observations from a randomized trial suggested
  • lower ST rates with the newer-generation everolimus-eluting stent (<1%) compared to rates for the older-generation paclitaxel-eluting stent (3%).3

So while this uncommon but catastrophic complication persists in contemporary practice, its low frequency has made it difficult to study, particularly in the real-world setting.

In the current issue of the Journal of Invasive Cardiology, Dores et al have analyzed the outcome data from a large-volume, single-center prospective registry evaluating the incidence of definite ST.4 The study consisted of 3806 patients who underwent percutaneous coronary intervention between January 2003 and December 2010. In the registry, a total of 2388 patients (62.7%) were treated with first-generation DESs (sirolimus-eluting and paclitaxel-eluting stents), while 1418 patients (37.3%) were treated with second-generation DESs (everolimus-eluting and zotarolimus-eluting stents). The overall occurrence of Academic Research Consortium (ARC)-defined definite ST at 12 months was 1.2% (46 events). After correction for baseline differences between study groups and other variables deemed to influence the occurrence of ST, Dores et al concluded that the

  • use of first-generation DESs was associated with a 2.4-fold increase in the risk of definite ST. Among the cases receiving a first-generation DES,
  • the risk of ST was higher for paclitaxel-eluting versus sirolimus-eluting stents.

The observations from Dores et al are consistent with prior reports, in that the rates of definite ST are low and decreasing in recent years. As can be seen in Dores’s Figure 3 considering annual frequency of definite ST, the numerically highest years were 2003 and 2004, and over the most recent years, rates have averaged closer to 1%. Questions will remain in the field of ST, some of which will require large-scale registry data to help consider their relevance and possible answers.

The underlying challenge remains how to afford to study such low-frequency events with multifactorial and variable etiologies. Beyond the events during the interventional procedure and device utilized (ie, type of DES), many other factors that affect the rate of ST (eg, patient genotype and phenotype) are still being unraveled. Considerable research has gone into finding predictive subsets for those at increased risk for ST.5 Among identified factors are the timing and acuity of presentation. Patients presenting with an ACS are known to be more vulnerable to early ST than patients with chronic stable disease. The initial plaque rupture of ACS triggers a prothrombotic avalanche of events, from platelet activation to local thrombus formation and occlusion, spasm, and distal embolization of microcirculatory debris.6 It is interesting to note in the Dores et al. registry that patients receiving second-generation DESs more often presented with an ACS, making their observations reassuring that ST rates can be kept low with evolving care strategies.

In an analysis of the ACUITY trial, which particularly enrolled patients with ACS,7 early ST occurred with similar frequency after anticoagulation with either heparin plus glycoprotein IIb/IIIa inhibitors or bivalirudin (with or without IIb/IIIa inhibitors), and not surprisingly was predicted by diffuse atherosclerosis, suboptimal angiographic results, and inadequate pharmacotherapy. Such patients also had a higher incidence of renal insufficiency and insulin-dependent diabetes mellitus. The ACUITY subanalysis found that the rate of ST within 30 days was 1.4%, significantly higher than the 0.3%-0.5% ST rates reported among patients with stable coronary artery disease.

Among the most critical factors in mitigating the risk of ST are adequate and consistent dual-antiplatelet therapy (DAPT). A remarkable interpatient variability in the antiplatelet response to clopidogrel has been well documented. The frequency of

  • clopidogrel hyporesponsiveness has been reported among as many as 30% of patients undergoing PCI, yet the clinical relevance of antiplatelet responsivity is modest,8 again since the factors related to ST are many.
  • Loss-of-function alleles have been identified for clopidogrel metabolism, and these have been associated with an increased risk of adverse cardiovascular events, including ST.
  • Among patients with ACS, the need for more rapid and potent pharmacological suppression of platelet reactivity in the prevention of early ST is highlighted in clinical trials testing newer antiplatelet therapies.

In a landmark trial,

  • prasugrel, a more potent, consistent, and faster-acting third-generation thienopyridine has shown a significant reduction in overall ST rates compared to clopidogrel (1.1% vs 2.4%).9 Similarly,
  • ticagrelor, an oral, reversible, direct-acting inhibitor of the ADP receptor P2Y12 that has a more rapid onset and greater potency of platelet inhibition than clopidogrel was recently studied in a large clinical trial.
  • In the Platelet Inhibition and Patient Outcomes (PLATO) study, there was a significant reduction in ST in the ticagrelor group vs the clopidogrel group, with definite ST rates of 1.3% and 1.9%, respectively.10

It is becoming clear that there has been a generational improvement in DESs that has reduced the risk of ST. This has been paralleled by advances in DAPT regimens and interventional techniques that have collectively reduced the risk of ST. While the field will continue to search for answers to the

  • optimum duration of DAPT, and whether this is dependent on
  • stent type and
  • acuity of patient presentation,

DES polymers, design characteristics, and the antiproliferative drugs will also continue to evolve. Understanding incremental improvements in techniques, devices, and drugs will remain quite challenging as the rate of ST slowly moves closer to zero.

References

1. Cutlip DE, Baim DS, Ho KK, et al. Stent thrombosis in the modern era: a pooled analysis of multicenter coronary stent clinical trials. Circulation. 2001;103(15):1967-1971.

2. Palmerini T, Biondi-Zoccai G, Della Riva D, et al. Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis. Lancet. 2012;379(9824):1393-1402.

3. Kedhi E, Joesoef KS, McFadden E, et al. Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): a randomised trial. Lancet. 2010;375(9710):201-209.

4. Dores H, Raposo L, Teles RC, et al. Stent thrombosis with second versus first generation drug eluting stents in real world coronary percutaneous intervention. J Invasive Cardiol. 2013;25(7):330-336.

5. Holmes DR Jr, Kereiakes DJ, Garg S, et al. Stent thrombosis. J Am Coll Cardiol. 2010;56(17):1357-1365.

6. Finn AV, Nakano M, Narula J, Kolodgie FD, Virmani R. Concept of vulnerable/unstable plaque. Arterioscler Thromb Vasc Biol. 2010;30(7):1282-1292.

7. Aoki J, Lansky AJ, Mehran R, et al. Early stent thrombosis in patients with acute coronary syndromes treated with drug-eluting and bare metal stents: the Acute Catheterization and Urgent Intervention Triage Strategy trial. Circulation. 2009;119(5):687-698.

8. Holmes DR Jr, Dehmer GJ, Kaul S, Leifer D, O’Gara PT, Stein CM. ACCF/AHA clopidogrel clinical alert: approaches to the FDA “boxed warning.” A report of the American College of Cardiology Foundation Task Force on Clinical Expert Consensus Documents and the American Heart Association. J Am Coll Cardiol. 2010;56(4):321-341.

9. Wiviott SD, Braunwald E, McCabe CH, et al; TRITON-TIMI 38 Investigators. Intensive oral antiplatelet therapy for reduction of ischaemic events including stent thrombosis in patients with acute coronary syndromes treated with percutaneous coronary intervention and stenting in the TRITON-TIMI 38 trial: a subanalysis of a randomised trial. Lancet. 2008;371(9621):1353-1363.

10. Wallentin L, Becker RC, Budaj A, et al; the PLATO Investigators. Ticagrelor versus clopidogrel in patients with acute coronary syndrome. N Engl J Med. 2009;361(11):1045-1057.

Disclosure: The authors have completed and returned the ICMJE Form for Disclosure of Potential Conflicts of Interest. The authors report no conflicts of interest regarding the content herein.

Address for correspondence: David J. Moliterno, MD, Department of Internal Medicine, The University of Kentucky, 900 S. Limestone Avenue, 329 Wethington Building, Lexington, KY 40536-0200. Email: moliterno@uky.edu

Journal of invasive Cardiology, Volume 25 – Issue 7 – July 2013

http://www.invasivecardiology.com/articles/stent-thrombosis-through-generations

Stent Thrombosis With Second- Versus First-Generation Drug-Eluting Stents in Real-World Percutaneous Coronary Intervention: Analysis of 3806 Consecutive Procedures From a Large-Volume Single-Center Prospective Registry

Stent thrombosis (ST) is a serious and often fatal event limiting the efficacy of percutaneous coronary intervention (PCI). The pathophysiology of ST is multifactorial, and underlying causes including stent-, procedure-, lesion-, and patient-related factors seem to play different roles at different time points after the index procedure.1,2 When compared to first-generation (1stGEN) drug-eluting stents (DESs), newer DESs have been associated with a lower rate of ST in several randomized clinical trials, subsequent meta-analyses, and also in some registries, such as the recently published Swedish Coronary Angiography and Angioplasty Registry (SCAAR).3-7 New, second-generation (2ndGEN) DESs have been developed with improved design and materials, both of which may contribute to overcome some of the limitations of the older DESs. Decreased strut thickness — resulting in higher flexibility, conformability, and deliverability — and optimized polymer biocompatibility and drug delivery kinetics have been shown to contribute to a low late-loss rate and to a lower thrombotic risk.1 Despite the evidence pointing in this direction, most of the data comes from post hoc analysis and meta-analysis, mainly because studies defining ST as a primary endpoint are scarce.

We aimed to assess whether or not the systematic use of a 2ndGEN DES, relative to the 1stGEN DES, translates into a higher safety rate in a real-world population where DES implantation was indicated. For that purpose, we conducted an analysis of a single-center prospective registry, evaluating the incidence of definite ST, as defined by the Academic Research Consortium (ARC), at 12 months of follow-up as the primary outcome measure.

Author(s): 

Helder Dores, MD, Luís Raposo, MD, Rui Campante Teles, MD, Carina Machado, MD, Sílvio Leal, MD, Pedro Araújo Gonçalves, MD, Henrique Mesquita Gabriel, MD, Manuel Sousa Almeida, MD, Miguel Mendes, MD

Abstract

Background and Aims. When compared to their first-generation (1stGEN) counterparts, second-generation (2ndGEN) drug-eluting stents (DESs) have been associated with better clinical outcomes in randomized clinical trials, namely by reducing the rates of stent thrombosis (ST). Our goal was to investigate whether or not the broad use of newer devices would translate into higher safety in a real-world population. For that purpose, we compared the occurrence of definite ST at 12 months between two patient subsets from a large-volume single-center registry, according to the type of DES used. Total mortality was a secondary endpoint.

Methods and Results. Between January 2003 and December 2010, a total of 3806 patients were submitted to percutaneous coronary intervention (PCI) with only 1stGEN or 2ndGEN DES: 2388 patients (62.7%) were treated with 1stGEN DES only (sirolimus-eluting stent [SES] = 1295 [34.0%]; paclitaxel-eluting stent [PES] = 943 [24.8%]; both stent types were used in 150 patients) and 1418 patients (37.3%) were treated with 2ndGEN DESs only. The total incidence of definite ST (as defined by the Academic Research Consortium) at 12 months was 1.2% (n = 46). After correction for baseline differences between study groups and other variables deemed to influence the occurrence of ST, the use of 1stGEN DES was associated with a significant 2.4-fold increase in the risk of definite ST (95% confidence interval [CI], 1.05-5.42; P=.039) at 12 months; adjusted risk was higher with PES (hazard ratio [HR], 3.6; 95% CI, 1.48-8.70; P=.005) than with SES (HR, 2.3; 95% CI, 0.92-5.65; P=.074). Total mortality (3.7% vs 3.5%) did not differ significantly between groups (adjusted HR, 1.2; 95% CI, 0.81-1.84, P=.348).

Conclusions. Our data suggest that in the real-world setting of contemporary PCI, the unrestricted use of newer 2ndGEN DESs translates into an improvement in PCI safety (relative to 1stGEN DESs), with a significantly lower risk of definite ST at 12 months.

Journal of Invasive Cardiology                    Volume 25 – Issue 7 – July 2013

J INVASIVE CARDIOL 2013;25(7):330-336

Key words: stent thrombosis, drug-eluting stent

http://www.invasivecardiology.com/articles/stent-thrombosis-second-versus-first-generation-drug-eluting-stents-real-world-percutaneous

 

Part V

Stent Thrombosis in Randomized Trials of Drug-Eluting Stents:

Reappraisal of the Synthesis of Evidence!

Stent Thrombosis in Randomized Clinical Trials of Drug-Eluting Stents

Laura Mauri, M.D., Wen-hua Hsieh, Ph.D., Joseph M. Massaro, Ph.D., Kalon K.L. Ho, M.D., Ralph D’Agostino, Ph.D., and Donald E. Cutlip, M.D.

N Engl J Med 2007; 356:1020-1029February 12, 2007DOI: 10.1056/NEJMoa067731

http://www.nejm.org/doi/full/10.1056/NEJMoa067731?goback=%2Egde_675087_member_263490750

 

EDITORIAL on  bare-metal stents (BMS) vs sirolimus-eluting stents (SES)

With full interest, we read the article “Stent thrombosis in randomized clinical trials (RCT) of drug-eluting stents (DES)” by Mauri L et al, previously published in the New England Journal of Medicine in 2007 [1]. The authors concluded that “The incidence of stent thrombosis (ST) did not differ significantly between patients with DES and those with bare-metal stents (BMS) in RCT, although the power to detect small differences in rates was limited” [1]. 
I have the following concerns. First and foremost, ST in the BMS groups occurred more frequently among patients who underwent intervening target lesion revascularization (TLR) versus those who did not [1]. And since brachytherapy was the standard of care for treatment of restenosis at that time, it was used more frequently in patients with restenosis following BMS (9 out of 11 patients with BMS who underwent intervening TLR and subsequently developed definite/probable ST), in whom restenosis occurred more frequently and more diffusely, compared with DES [1]. In an observational study, brachytherapy was associated with a high risk of late (thrombotic) total occlusion of the index vessel at 6-month angiographic follow-up [2]. In that study, the mean time from brachytherapy to late total occlusion was 5.4 ± 3.2 months [2]. Therefore, brachytherapy may constitute selection bias for devices with higher rates of restenosis, by increasing the risk of late ST following intervening procedures for these devices. This might explain the much higher rate of late (beyond 30 days to 1 year) definite/probable ST following BMS compared with sirolimus-eluting stents (SES) (1% versus 0.1%, respectively), which was obviously responsible for the higher overall rate of definite/probable ST following BMS compared with SES at 4-year follow-up (1.7% versus 1.5%, respectively, p=0.7) [1]. It is worth mentioning that

  • BMS was associated with a lower rate of very late (beyond 1 year) definite/probable ST compared with SES (0.4% versus 0.9%, respectively) [1]. Second,
  • the study included 4 RCT of SES published from 2002 to 2004, and 4 RCT of paclitaxel-eluting stents (PES) published from 2003 to 2005, all of which were published before the Academic Research Consortium (ARC) report that put forward the current standard definitions of ST [3].

Thus, the ARC definitions were applied to all of these trials retrospectively, and therefore, might have missed some of the ST events.

  • Third, the study enrolled 878 patients with SES versus 870 treated with the corresponding BMS, 1400 patients with PES versus 1397 treated with the corresponding BMS; thus, it was clearly underpowered for detection of a difference in rare-by-nature events such as ST.  Forth, the
  • RCT included in the study were the earliest RCT of SES and PES; hence, they enrolled relatively low-risk patient, lesion, and clinical subsets, that do not reflect real-world practice.
  • Finally, the individual databases of RCT of PES were managed by Boston Scientific, which might introduce another source of bias!

References

1. Mauri L, Hsieh WH, Massaro JM, et al. Stent thrombosis in randomized clinical trials of drug-eluting stents. N Engl J Med 2007;356:1020-9.

2. Waksman R, Bhargava B, Mintz GS, et al. Late total occlusion after intracoronary brachytherapy for patients with in-stent restenosis. J Am Coll Cardiol. 2000;36:65-8.

3. Cutlip DE, Windecker S, Mehran R, et al. Clinical end points in coronary stent trials: a case for standardized definitions. Circulation 2007;115:2344-51.

Part VI

Duration of Dual Antiplatelet Therapy following Zotarolimus-Eluting Stents and A New Strategy for Discontinuation of Dual Antiplatelet Therapy

Dr. Pearlman: Drug eluting stents decrease in stent stenosis from endothelial exuberant growth at the cost of increased propensity to thrombosis, offset by prolonged use of dual anti platelet medication. The net effect depends on compliance which if good results in net decrease. The risk has increased due to drug eluting stent prevalence, but that is offset by management with dual anti platelet agents, so the net incidence is reduced. There have been a number of presentations based on angioscopy showing thrombus inside bare metal and drug eluting stents that supported the general concensus also supported by TIMI trials that stent thrombosis is promoted by metal stents until they endothelialize, and that drug-eluting stents impede the endothelialization “too well” prolonging that issue, so minimal dual platelet agent duration in practice is 3 months for BMS, 6-12 months for DES, but benefit fades to 2% at 1 year, 1% at 2 years at which point risk-benefit is unconvincing and many stop plavix, while some insist it is a lifetime medication.

With full interest, we read the article “Dual antiplatelet therapy duration and clinical outcomes following treatment with zotarolimus-eluting stents (ZES)” by Kandzari DE, et al [1]. The authors concluded that “Among patients treated with ZES, late-term events of death, myocardial infarction (MI), stroke, and stent thrombosis (ST) do not significantly differ between patients taking 6 months dual antiplatelet therapy (DAPT) compared with continuation beyond 1 year” [1].
I have the following concerns. First, although the authors claimed that their study was based on a pooled analysis of patients who received ZES in 5 ‘clinical trials’; actually, 2 out of 5 were not ‘trials’. One was a registry of direct stenting with ZES [2], and the other was a study of pharmacokinetics of ABT 578 in a subset of the ENDEAVOR II trial, that was not published in a medical journal [3]! Second, patients were classified by “DAPT adherence according to the most recent report of compliance with aspirin and thienopyridine”. Evidence supports that premature discontinuation clopidogrel is the most powerful independent predictor of late ST [4].

There is no evidence, however, that stopping aspirin predisposes to ST following drug-eluting stent implantation. Third, follow-up of DAPT adherence was done at 30 days, 6 months, then annually for 3 years. Reporting DAPT adherence based on “the last reported follow-up interval of compliance with both aspirin and clopidogrel” does not reflect the actual duration of clopidogrel received in any of the comparison groups. Forth, in the second comparison of “6 months on/24 months off” (on DAPT at 6 but not at 24 months) versus “≥24 months” (on DAPT at 6 and 24 months)”, the first group included, by definition, patients who were also on DAPT at 12 months (but not at 24 months). Thus, it cannot be taken to reflect a comparison between 6-month DAPT and 24-month DAPT!  Fifth, the ENDEAVOR II and ENDEAVOR III trials were published in 2006, before the publication of ARC report [5,6]. Therefore, the ARC definitions of ST were applied retrospectively in many patients, which might explain the absence of ‘probable’ ST in all comparison groups, in all time points. Sixth, major bleeding was defined exclusively as “any hemorrhagic event that required blood product transfusion”. This might explain why such rates were 0% in all groups, in all time points. Finally, the study involved low-risk patient and lesion subsets, and was statistically underpowered for rare events such as ST, cardiac death, or MI.

References

1. Kandzari DE, Barker CS, Leon MB, et al. Dual antiplatelet therapy duration and clinical outcomes following treatment with zotarolimus-eluting stents. JACC Cardiovasc Interv 2011;4:1119-28.
2. Schultheiss HP, Grube E, Kuck KH, et al. Endeavor II Continued Access Investigators. Safety of direct stenting with the Endeavor stent: results of the Endeavor II continued access registry. EuroIntervention 2007;3:76–81.
3. Pharmacokinetics of ABT-578 in patients from Endeavor stent: results from a subset of a double-blind, randomized, multicenter (ENDEAVOR-II) trial. In: The ENDEAVOR II Study 30-Day Pharmacokinetic Report. Abbot Park, IL: Abbott Laboratories, 2004.
4. Iakovou I, Schmidt T, Bonizzoni E, et al. Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 2005;293:2126-30.
5. Fajadet J, Wijns W, Laarman GJ, et al. ENDEAVOR II Investigators. Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical and angiographic results of the ENDEAVOR II trial. Circulation 2006;114:798–806.
6. Kandzari DE, Leon MB, Popma JJ, et al. ENDEAVOR III Investigators. Comparison of zotarolimus-eluting and sirolimus-eluting stents in patients with native coronary artery disease: a randomized controlled trial. J Am Coll Cardiol 2006;48:2440–7.
SOURCE
interventions.onlinejacc.org <http://interventions.onlinejacc.org> interventions.onlinejacc.org <http://interventions.onlinejacc.org>

A New Strategy for Discontinuation of Dual Antiplatelet Therapy

With interest, we read the article “A New Strategy for Discontinuation of Dual Antiplatelet Therapy: REal Safety and Efficacy of 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation (RESET) Trial” by Kim B-K, et al [1]. The authors concluded that Endeavor zotarolimus-eluting stent (E-ZES) with 3-month dual antiplatelet therapy (DAPT) was noninferior to other drug-eluting stents (DES) with 12-month DAPT (standard therapy) with respect to the occurrence of the primary endpoint (a composite of cardiovascular death, myocardial infarction (MI), stent thrombosis (ST), target vessel revascularization (TVR), or bleeding at 1 year) [1]. 
I have the following concerns. First, the study design was defective since the comparator group should have been composed of patients who received the same stent (E-ZES) and took DAPT for 12 months. Moreover, the comparator group was not homogeneous, since it was composed of patients who received sirolimus-eluting stents (SES, Cypher, 28.5%), everolimus-eluting stents (EES, Xience, 30%), and ZES with a biocompatible polymer (R-ZES, Resolute, 41.5%). This would further complicate the comparison since it dilutes the results of the comparator group by mixing first- (Cypher) with second-generation (Xience and Resolute) DES. Further confusion was added with the unjustified stratified randomization of the comparator group: patients with Diabetes mellitus (DM) and those with acute coronary syndrome (ACS) were assigned to R-ZES; those with short lesions to SES; those with long lesions to EES. Second, whereas the trial compared two regimens (short versus long) of DAPT following DES, the primary endpoint adopted by the authors included ischemia-driven TVR; an event completely unrelated to the safety or efficacy of a DAPT regimen. Third, the authors could not explain why the event rates were very low (cardiovascular death 0.2%, MI 0.2%, ARC definite/probable ST 0.2%) compared with previous reports of the E-ZES at a similar time point: ENDEAVOR II trial (total death 1.2%, MI 2.7%, ST 0.5% at 9 months); ENDEAVOR IV trial (cardiac death 0.5%, MI 1.6%, ARC definite/probable ST 0.9% at 12 months) [2,3]. Forth, unexpectedly, both TVR and ST rates in patients with DM who received E-ZES were lower than the rates for the whole E-ZES group! And in the ACS subgroup, patients who received the standard therapy (R-ZES) had rates of cardiovascular death 0%, MI 0%, and ST 0%, at 12 months! And surprisingly, in the subset of short lesions, despite the shorter duration of DAPT, bleeding rates were higher with E-ZES + 3-month DAPT versus standard therapy (0.6% versus 0%)! Fifth, based on the current low 12-month rates of primary composite endpoint (4.7%) compared with the figure used for statistical power calculation (10-11%), the trial was underpowered for the primary endpoint. Additionally, the non-inferiority margin of 4% was very wide for the 12-month rates of primary endpoint (4.7%). Finally, enrollment of 2117 patients in 26 centers over 20 months speaks of a low enrollment rate of 4.1 patients/center/month, that reflects an overt selection bias.

References 


1. Kim BK, Hong MK, Shin DH, et al. A new strategy for discontinuation of dual antiplatelet therapy: the RESET Trial (REal Safety and Efficacy of 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation). J Am Coll Cardiol 2012;60:1340-8.

2. Fajadet J, Wijns W, Laarman GJ, et al. Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical and angiographic results of the ENDEAVOR II trial. Circulation 2006;114:798-806.

3. Leon MB, Mauri L, Popma JJ, et al. A randomized comparison of the ENDEAVOR zotarolimus-eluting stent versus the TAXUS paclitaxel-eluting stent in de novo native coronary lesions 12-month outcomes from the ENDEAVOR IV trial.

SOURCE

J Am Coll Cardiol 2010;55:543-54.

content.onlinejacc.org content.onlinejacc.org

http://digitalreprints.elsevier.com/i/85787/6

Conclusions

by Larry H Bernstein, MD, FCAP

This has been a six part discussion on the progress of stent design, and the decreasing problem of stent thrombosis, which evades elimination with a tradeoff in greater utility and somewhat greater risk.  However, the risk of thrombotic events has become low enough that accurate comparisons of stent technologies, method of placement, and antithrombotic techniques to avoid thrombotic complications is burdened by statistical power limitations.  In addition to the issue of sample size, there is an issue of patient characteristics that probably confer increased risk.

In the first part we found that stent placement is done in 15-20% of cases at a bifurcation site, where it is most favorable for plaque buildup from turbulent flow and shear stress.  Recall that Routledge et al. (1) presented 2-year outcome data of 477 patients treated for bifurcation coronary disease with provisional side branch T-stenting using drug-eluting stents (DES), and they concluded that a systematic approach is feasible for 90% of the patients, with acceptable efficacy and safety profiles.  There are several inherent problems that encumbered any analysis.  These were: numerous anatomic configurations of bifurcation types, with the concern for late complications, restenosis, and its frequency, leading to the dilemma of placing two stents versus one stent, and then another as a side branch, if needed.  The study (1) did indicate that provisional stenting is feasible in 90% of all patients, and those who received a second stent in the side branch, 28%, had similar long-term outcomes as those treated with 1 stent. The outcome of this study is similar to that of the Nordic Bifurcation study, which observed no difference in outcomes at 6 months’ follow-up between 1 and 2 stents (9).  As for technique, the latest Nordic Bifurcation Stent Technique study, comparing the culotte and crush techniques, reported low rates of angiographic restenosis and major adverse cardiac events for both techniques (10). However, kissing balloon was shown to be critical in preventing restenosis. Provisional T-stenting offers several advantages compared with other bifurcation techniques. It seems to be the simplest and is associated with favorable long-term outcomes.  It has also been shown that side branches and osteal disease are most problematic and that dedicated devices will have a role in left main disease.

The next issue for consideration is the use of biodegradable drug-eluting stents versus durable polymer DES. Biodegradable polymer DES resulted in lower rates than durable polymer DES of

  • target lesion revascularization (hazard ratio [HR] 0.82, 95 percent confidence interval [CI] 0.68-0.98, P=0.029).
  • definite stent thrombosis (the study’s primary safety endpoint), (HR 0.56, 95 percent CI 0.35-0.90, P=0.015).
  • very late stent thrombosis (clots occurring more than one year after angioplasty) for the biodegradable polymer group (HR 0.22, 95 percent CI 0.08-0.61, P=0.004).
  • cardiac death and heart attack (HR 0.59, 95 percent CI 0.73-0.95, P=0.031).

The third topic for consideration is the tradeoff between stent flexibility versus the concertina effect. Longitudinal strength was not recognized as a critical parameter by clinicians or regulators until recently. Measurements, only now becoming publically available, seem to confirm vulnerability of some modern designs to longitudinal deformation. Stent designs now provide high flexibility by reducing the number of connecting links between stent segments and by allowing the connecting links to easily change their length.  However, this design results in reduced longitudinal strength with the unintended effect of inducing some risk of longitudinal compression of the stent (the “concertina effect”).  While contemporary coronary stents are much more deliverable than older-generation stents, longitudinal deformation has emerged as a “new” complication in modern coronary stent platforms. This is more frequently associated with a particular stent design: the “offset peak-to-peak” stent design.  Thin-strut stents improve deliverability and conformability. There is only limited evidence that thinner struts may result in less vessel wall damage reducing risk of restenosis. The trend of thinner strut platforms has triggered innovative designs to maintain stent radial strength. The development of longer, thinner, more flexible, and easier-to-deliver stent platforms made percutaneous coronary intervention (PCI) possible even in the most tortuous anatomy and calcified vessels.  Longitudinal stent deformation, the distortion or shortening of a stent in the longitudinal axis is the effect of a longitudinal compression force on the stent rings, causing them to nest or concertinate.

The fourth question is the effect of stent design on stent thrombosis.  A recent retrospective analysis provided further valuable information on the frequency and mechanisms of longitudinal stent deformation. The study involved 4455 interventional cases performed during a 4-year period. Stent deformation occurred in a total of 9 cases (0.2%) and affected 0.097% of stents deployed.   Longitudinal stent deformation is probably not a “class effect,” but highly dependent on a particular stent design.

Stent thrombosis (ST), while infrequent, remains a dreaded complication of percutaneous coronary revascularization because of the associated rates of

  • major myocardial infarction (60%-70%) and
  • early mortality (20%-25%).1

the emergence of ST redirected the efforts of the cardiology community to mitigate or eliminate this potentially catastrophic event by

  • stent design and strut thinness,
  • the advent of drug-eluting stent (DES) options, and
  • more potent antithrombotic therapy

DESs have been associated with higher ST rates as compared to their bare-metal counterparts, particularly when utilized among high-risk groups and high-risk lesions.

The overall occurrence of Academic Research Consortium (ARC)-defined definite ST at 12 months was 1.2% (46 events). After correction for baseline differences between study groups and other variables deemed to influence the occurrence of ST, Dores et al concluded that the

  • use of first-generation DESs was associated with a 2.4-fold increase in the risk of definite ST. Among the cases receiving a first-generation DES,
  • the risk of ST was higher for paclitaxel-eluting versus sirolimus-eluting stents.

It should not be a surprise that patients presenting with an ACS are known to be more vulnerable to early ST than patients with chronic stable disease. The initial plaque rupture of ACS triggers a prothrombotic avalanche of events, from platelet activation to local thrombus formation and occlusion, spasm, and distal embolization of microcirculatory debris.6 It is interesting to note in the Dores et al. registry that patients receiving second-generation DESs more often presented with an ACS, making their observations reassuring that ST rates can be kept low.   Patients who had early ST were characterized by diffuse atherosclerosis, angiography, inadequate pharmacotherapy, and had a higher incidence of renal insufficiency and insulin-dependent diabetes mellitus.  The ACUITY subanalysis found that the rate of ST within 30 days was 1.4%, significantly higher than the 0.3%-0.5% ST rates reported among patients with stable coronary artery disease.

Among the most critical factors in mitigating the risk of ST are adequate and consistent dual-antiplatelet therapy (DAPT).  Among patients with ACS, the need for more rapid and potent pharmacological suppression of platelet reactivity in the prevention of early ST is highlighted in clinical trials testing newer antiplatelet therapies.  In the Platelet Inhibition and Patient Outcomes (PLATO) study, there was a significant reduction in ST in the ticagrelor group vs the clopidogrel group, with definite ST rates of 1.3% and 1.9%, respectively.

This brings us to ST in randomized trials of DES.  There was a much higher rate of late (beyond 30 days to 1 year) definite/probable ST following BMS compared with sirolimus-eluting stents (SES) (1% versus 0.1%, respectively).  BMS was associated with a lower rate of very late (beyond 1 year) definite/probable ST compared with SES (0.4% versus 0.9%, respectively) [1].  The different overall rate of definite/ probable ST following BMS compared with SES is nearly equal at 4-year follow-up (1.7% versus 1.5%, respectively), is indeterminate (p=0.7) [1]. The study was underpowered for detection of a difference in rare-by-nature events such as ST.

Finally, Dr. Pearlman analyzes the published studies concerning whether there should be a reduction in the length of dual antiplatelet therapy to six months.  Drug eluting stents decrease in stent stenosis from endothelial exuberant growth at the cost of increased propensity to thrombosis, offset by prolonged use of dual anti-platelet medication.  The risk has increased due to drug eluting stent prevalence, but that is offset by management with dual anti platelet agents, so the net incidence is reduced. Stent thrombosis is promoted by metal stents until they endothelialize, but drug-eluting stents impede the endothelialization, so minimal dual platelet agent duration in practice is 3 months for BMS, 6-12 months for DES, but benefit fades to 2% at 1 year, 1% at 2 years at which point risk-benefit is unconvincing.  Evidence supports that premature discontinuation clopidogrel is the most powerful independent predictor of late ST.

So here we have the status in a nutshell.

  • ST has driven the design of stents to be simpler to insert effectively, with a clear goal to minimize ST
  • The stent designs have resulted in thinner, and multi-segmented longer insertions as needed.
  • The result of improved stent design has been an effect of local vessel distortion.
  • The standard of practice is provisional T-branch DES
  • The use of dual antiplatelet therapy for not less than 1 year is determined by the time required for endothelialization of the artery.
  • There is a risk difference incurred by ACS versus stable disease, and by adequacy of antithrombotic therapy prior to an acute event.

Other related articles published on this Open Access Online Scientific Journal, include the following:

AHA, ACC Change in requirement for surgical support:  Class IIb -> Class IIa Level of Evidence A: Supports Nonemergent PCI without Surgical Backup (Change of class IIb, level of Evidence B).

Larry H Bernstein, MD, FCAP and Justin D Pearlman, MD, PhD, FACC

Survivals Comparison of Coronary Artery Bypass Graft (CABG) and Percutaneous Coronary Intervention (PCI) / Coronary Angioplasty

Larry H Bernstein, MD, FCAP and Aviva Lev-Ari, PhD, RN

Coronary Reperfusion Therapies: CABG vs PCI – Mayo Clinic preprocedure Risk Score (MCRS) for Prediction of5. in-Hospital Mortality after CABG or PCI

Larry H. Bernstein, MD, FCAP  and Aviva Lev-Ari, PhD, RN

Coronary Artery Disease – Medical Devices Solutions: From First-In-Man Stent Implantation, via Medical Ethical Dilemmas to Drug Eluting Stents

Aviva Lev-Ari, PhD, RN

Absorb™ Bioresorbable Vascular Scaffold: An International Launch by Abbott Laboratories

Aviva Lev-Ari, PhD, RN

CABG or PCI: Patients with Diabetes – CABG Rein Supreme

Aviva Lev-Ari, PhD, RN

To Stent or Not? A Critical Decision

Aviva Lev-Ari, PhD, RN

New Drug-Eluting Stent Works Well in STEMI

Aviva Lev-Ari, PhD, RN

Revascularization: PCI, Prior History of PCI vs CABG

Aviva Lev-Ari, PhD, RN

Drug Eluting Stents: On MIT’s Edelman Lab’s Contributions to Vascular Biology and its Pioneering Research on DES

Larry H Bernstein, MD, FCAP and  Aviva Lev-Ari, PhD, RN

Outcomes in High Cardiovascular Risk Patients: Prasugrel (Effient) vs. Clopidogrel (Plavix); Aliskiren (Tekturna) added to ACE or added to ARB

Aviva Lev-Ari, PhD, RN

Read Full Post »

Alternative Designs for the Human Artificial Heart: Patients in Heart Failure – Outcomes of Transplant (donor)/Implantation (artificial) and Monitoring Technologies for the Transplant/Implant Patient in the Community

Alternative Designs for the Human Artificial Heart: Patients in Heart Failure –  Outcomes of Transplant (donor)/Implantation (artificial) and Monitoring Technologies for the Transplant/Implant Patient in the Community

Authors and Curators: Larry H Bernstein, MD, FCAP and Justin D Pearlman, MD, PhD, FACC

and

Article Curator and Reporter: Aviva Lev-Ari, PhD, RN

Article ID #74: Alternative Designs for the Human Artificial Heart: Patients in Heart Failure – Outcomes of Transplant (donor)/Implantation (artificial) and Monitoring Technologies for the Transplant/Implant Patient in the Community. Published on 8/5/2013

WordCloud Image Produced by Adam Tubman

When the heart fails to function adequately, whether from large or multiple myocardial infarctions (tissue death/scarring) or from permanent inflammatory, toxic, microvascular or infectious muscle injury, it has two modes of failure: forward failure = inadequate pumping of blood to tissues, and backward failure = inadequate withdrawal of blood from the lungs, resulting in pulmonary congestion and elevated back-pressures which cause fluid to seep into air spaces (pulmonary edema) interfering with oxygen uptake. When the heart cannot be repaired, replacement is considered. Additional pumps may be placed in parallel and/or in series with the heart to assist circulation of blood. A heart from another patient (usually a patient deemed brain dead from trauma) or from a baboon may be transplanted to replace the ailing heart, or may be placed in tandem with the ailing heart, or the heart and lungs may be replaced together (heart-lung transplant). Additional options include the intra-aortic balloon pump, the Impella catheter pump, other ventricular assist devices. There is far greater demand for heart transplants than there are available suitable organs, so work continues on alternatives. Additional reasons to seek alternatives include the complications of transplantation. Transplantation requires shutting down the body defenses against foreign materials, called immune suppression, but the immune defense system protects against cancer and infection, so a one in five of the transplant patients succomb to cancer or infection, while others die of rejection due to insufficient suppression of the autoimmune system. Artificial materials exist that do not trigger autoimmune defenses, thereby avoiding that major issue, but energizing the pump, providing sufficient circulatory support and avoiding damage to the blood have been major hurdles.

This article has the following FIVE Parts:

Part I.  Alternative Models of Artificial Hearts, US and Europe

By Larry H Bernstein, MD, FCAP and Aviva Lev-Ari, PhD, RN

Part  II.  Comparison of the Cardiac Operations involved in an Organ Transplant of a Donor’s Heart vs Implantation of an Artificial Heart

By Justin D Pearlman, MD, PhD, FACC 

Part III. Comparative Analysis of Transplant Clinical Outcomes based on Data in:

Heart Transplant (HT) Indication for Heart Failure (HF): Procedure Outcomes and Research on HF, HT @ Two Nation’s Leading HF & HT Centers

By Larry H Bernstein, MD, FCAP and Aviva Lev-Ari, PhD, RN 

Part IV.  Imaging Technologies in use for Clinical Monitoring of Patients with Heart Transplant: Donor Human Heart and Artificial Heart

By Justin D Pearlman, MD, PhD, FACC 

Part V. The Failure of a Heart Transplant – Pathology and Autopsy Findings

by Larry H Bernstein, MD, FCAP

Conclusions

by Larry H Bernstein, MD, FCAP

 

Part I

Alternative Models of Artificial Hearts, US and Europe

By Larry H Bernstein, MD, FCAP and Aviva Lev-Ari, PhD, RN

 

Latest Innovations in Alternative Models of Artificial Hearts, US and Europe

by Aviva Lev-Ari, PhD, RN

UPDATED on 12/29/2013

Total Artificial Heart Manufacturer SynCardia Secures $14M in Growth Financing

December 17, 2013

Total Artificial Heart Manufacturer SynCardia Secures $14M in Growth Financing

$10M Financed by SWK of Dallas with $4M from Athyrium Opportunities Fund

A $14 million infusion of funding will allow SynCardia Systems, Inc. to respond to the rapid growth in the number of Total Artificial Heart implants and SynCardia Certified Centers that has occurred since 2010. As of Dec. 16, 2013, there were 155 implants of the SynCardia Total Artificial Heart, making 2013 another record-breaking year.

TUCSON, Ariz., Dec. 17, 2013 /PRNewswire/ — Privately held SynCardia Systems, Inc. announced today that it had raised $14 million to fund the rapid growth of the only approved medical device that eliminates the symptoms and source of end-stage heart failure, the SynCardia temporary Total Artificial Heart. The SynCardia Total Artificial Heart is the world’s first and only FDA, Health Canada and CE (Europe) approved Total Artificial Heart.

“SWK is very pleased to provide SynCardia this new capital in order to help further the growth of the company’s Total Artificial Heart,” Brett Pope, CEO of SWK Holdings Corporation, says of its $10-million financing. “We are very gratified to help expand the availability of this lifesaving device.”

“In 2013 we are setting another record for SynCardia Heart implants, nearly double what was then our 2011 record-breaking year of 81 implants,” says Michael Garippa, President and CEO of SynCardia. “As of Dec. 16, 155 SynCardia Total Artificial Hearts have been implanted this year.”

The financing positively affects the development of the new, smaller 50cc version of the approved 70cc SynCardia Total Artificial Heart, the availability of the Freedom portable driver and the use of SynCardia technology for destination therapy.

“We are pleased to support SynCardia’s continued clinical and commercial successes,” says Laurent Hermouet, a partner at Athyrium. “This latest financing will help reinforce SynCardia’s supply chain and manufacturing capabilities ahead of new product launches and increased production levels.”

The $4 million provided by Athyrium Capital Management in last week’s funding supplemented $15 million in long-term growth capital it provided to SynCardia in March 2013.

Wedbush PacGrow Life Sciences acted as exclusive placement agent for the offering.

The new financing allows SynCardia to accelerate the development and launch of its 50cc Total Artificial Heart* through an FDA-approved clinical study. Together, the 50cc and 70cc sizes of the Total Artificial Heart will fit almost all women and men, as well as many pediatric patients. With this expanded product line, SynCardia anticipates the tripling of the market size and sales potential for the SynCardia Total Artificial Heart.

The funds also will help the company meet the increasing demand for the Freedom portable drivers. In a letter dated Oct. 21, 2013, the FDA determined that the Freedom PMA supplement is approvable with the submission of additional information. The 13.5-pound wearable Freedom driver, which powers the SynCardia Heart while giving patients nearly unrestricted mobility, is already approved by Health Canada and has a CE Mark for Europe.

SynCardia is an innovative, 85-employee company focused on advanced medical technology targeting the NYHA Class IV heart failure market. There are 93 SynCardia Certified Centers worldwide where the SynCardia Heart is immediately available with an additional 35 hospitals undergoing the company’s four-phase certification program. As of Dec. 16, 2013, there have been 1,262 total implants of the SynCardia Total Artificial Heart worldwide.

SWK Holdings Corporation is a specialized finance company with a focus on the global healthcare sector. SWK partners with ethical product marketers and royalty holders to provide flexible financing solutions at an attractive cost of capital to create long-term value for both SWK’s business partners and its investors. SWK believes its financing structures achieve an optimal partnership for companies, institutions and inventors seeking capital for expansion or capital and estate planning by allowing its partners to monetize future cash flow with minimal dilution to their equity stakes. Additional information on the life science finance market is available on the company’s website at http://www.swkhold.com.

Athyrium Capital Management, LLC is an asset management company formed in 2008 to focus on investment opportunities in the global healthcare sector. Athyrium invests across all healthcare verticals including biopharma, medical devices and products and healthcare services, and partners with management teams to implement creative financing solutions to companies’ capital needs. The Athyrium team has substantial investment experience in the healthcare sector across a wide range of asset classes, including public equity, private equity, fixed income, royalties and other structured securities. Athyrium has over $600 million under management as of Sept. 30, 2013. The firm’s investors include public and corporate pension funds, charitable endowments, insurance companies, funds-of-funds, family offices and university endowments. For more information, please visit http://www.athyrium.com.

*The 50cc Total Artificial Heart is designed for use as a bridge to transplant in patients of smaller stature, including women and adolescents. It has been designated as a Humanitarian Use Device (HUD) by the FDA for destination therapy in adults and as a bridge to transplant in pediatric patients. Prior to clinical study, an Investigational Device Exemption (IDE) application that includes each indication must be approved by the FDA.
** CAUTION – The Freedom portable driver is an investigational device, limited by United States law to investigational use.
About the SynCardia temporary Total Artificial Heart
For additional information, please visit: http://www.syncardia.com
Like SynCardia on Facebook
Follow SynCardia on Twitter – @SynCardia
Connect with SynCardia on LinkedIn

SOURCE

SynCardia Systems, Inc.

Read more: Total Artificial Heart Manufacturer SynCardia Secures $14M in Growth Financing – FierceMedicalDevices http://www.fiercemedicaldevices.com/press-releases/total-artificial-heart-manufacturer-syncardia-secures-14m-growth-financing#ixzz2otlLCH8I
Subscribe at FierceMedicalDevices

UPDATED on 12/23/2013

First Carmat artificial heart implanted in human in France

http://medcitynews.com/2013/12/first-artificial-heart-implanted-human/

UPDATED on 3/27/2014

Carmat Investigates Death of First Artificial Heart Recipient

Posted in Cardiovascular by Stephen Levy on March 18, 2014

French artificial heart maker Carmat says it will not perform another human implant until it has determined the cause of death of the first patient fitted with the device.

That first patient, a 76-year-old man suffering from terminal heat failure, died March 2. He received the implanted artificial heart 75 days before, on December 18. The Georges Pompidou European Hospital in Paris, where the implantation was performed, announced the death.

 

Carmat
Artificial heart internals (Courtesy Carmat)

Alain Carpentier, MD, the inventor of the heart, told the Journal du Dimanche on March 16 that the heart had stopped after a short circuit, although the exact reasons behind the death were still unknown.

“We are trying to understand where this electronic problem came from and why,” Carpentier told the French weekly. “Our engineers are working night and day to understand, and they will find (the reason).”

Velizy Villacoublay, France–based Carmat said in a news release on March 17 that it is continuing to analyze the data from the first implanted prosthesis. The company further stated that it will continue the clinical trial once it has obtained the results of the data from the first implantation.

Reuters reports that Philippe Pouletty, director general of Truffle Capital, one of Carmat’s main shareholders, told i>Tele television, “Patients are still being chosen, but of course we will wait to hear a little more on the causes of the death of the first patient before transplanting another artificial heart.”

The company explained that its detailed analysis of the data is still being carried out. More than 4000 pieces of data are recorded every second, it said. These include inputs from the artificial heart itself, its control console, and their respective power supplies.

Also of great interest are the very complex interactions between the weakened heart of the patient and the prosthesis. At the current time, Carmat says, there is no single explanation, only hypotheses that will be substantiated or not in the coming weeks by in-house and external experts. The results of the analyses of the first implantation, and the subsequent implantations, will be reviewed by the Data and Safety Monitoring Board (DSMB).

From the company’s point of view, the first implantation was a success. The patient survived for 74 days within the framework of a trial where the benchmark for success was 30 days. Carmat says that the approved medical centers are continuing to assess next patients for the ongoing clinical trial.

Pouletty said that the data analysis would be complete within “a few weeks.” The company has previously stated that if it passed this first safety test, it intends to fit the device into about 20 more patients with less severe heart failure later this year. It hopes to apply for CE Marking to market its device in Europe by 2015.

Stephen Levy is a contributor to Qmed and MPMN.

SOURCE

http://www.qmed.com/news/carmat-investigates-death-first-artificial-heart-recipient?cid=nl.qmed02

 

UPDATED on 3/6/2014

Artificial heart patient in France dies – Frenchman died 75 days after surgery

Thomson Reuters Posted: Mar 04, 2014 5:11 PM ET Last Updated: Mar 04, 2014 5:12 PM ET

The first patient fitted with an artificial heart made by the French company Carmat has died, the hospital that had performed the transplant in December has announced.

Carmat artificial heartCarmat’s bioprosthetic device is designed to replace the real heart for as much as five years, mimicking nature’s work using biological materials and sensors. (Benoit Tessier/Reuters)

The 76-year-old man died on Sunday, 75 days after the operation, the Georges Pompidou European Hospital in Paris said in a statement, adding that the cause of his death could not be known for sure at this stage.

When he was fitted with the device, the man was suffering from terminal heart failure, when the sick heart can no longer pump enough blood to sustain the body, and was said to have only a few weeks, or even days, to live.

Carmat’s bioprosthetic device is designed to replace the real heart for as much as five years, mimicking nature’s work using biological materials and sensors. It aims to help the thousands of patients who die each year while awaiting a donor, and reducing the side-effects associated with transplants.

“Carmat wishes to pay tribute to the courage and the pioneering role of this patient and his family, as well as the medical team’s dedication,” a company spokeswoman said.

She stressed that it was premature to draw any conclusions on Carmat’s artificial heart at this stage.

Three more patients in France with terminal heart failure are due to be fitted with the device. The clinical trial will be considered a success if the patients survive with the implant for at least a month.

If it passes the test, Carmat has said it would fit the device into about 20 patients with less severe heart failure.

Extending life

“The doctors directly involved in the post-surgical care wish to highlight the value of the lessons learned from this first clinical trial, with regard to the selection of the patient, his surveillance, the prevention and treatment of difficulties encountered,” the hospital said in its statement.

An in-depth analysis of the medical and technical data gathered since the patient’s operation will be needed to establish the cause of his death, the hospital added.

Carmat estimates around 100,000 patients in the United States and Europe could benefit from its artificial heart, a market worth more than $12 billion.

Among Carmat’s competitors for artificial heart implants are privately-held SynCardia Systems and Abiomed, both of the United States.

SynCardia’s artificial heart is the only one approved both in the United States and the European Union and has been implanted in more than 1,200 patients to keep them waiting for a heart from a matching donor. The longest a patient has lived with the device is just under four years prior to a transplant.

Carmat’s heart is designed to serve not as a bridge to transplant but as a permanent implant, extending life for terminally ill patients who cannot hope for a real organ, generally because they are too old and donors too scarce.

Carmat’s shares, which have risen nearly five-fold since floating on the Paris stock market in 2010, closed at 95 euros before Monday’s news, giving the company a market capitalization of around 407 million euros

SOURCE

 

December 20, 2013 12:11 pm by 

healthy heartPARIS (Reuters) – France’s Carmat said on Friday it had carried out the first human implantation of its artificial heart.The operation, performed on Wednesday at the Georges Pompidou European Hospital in Paris, went smoothly, Carmat said in a statement, adding that the patient was being monitored in the intensive care unit but was awake and talking.(Reporting by Natalie Huet; editing by Mark John)

Read more: http://medcitynews.com/2013/12/first-artificial-heart-implanted-human/#ixzz2oLlFRyDG

An artificial heart from a French company is to be tested in patients in four countries.

ArtificialHeart

By ANNE EISENBERG
Published: July 13, 2013 – The New York Times, Novelties

SCIENTISTS have long searched for a durable artificial heart that can work as efficiently as the one supplied by nature.

Carmat

Cow tissue will be used on surfaces of membranes — represented by elliptical shapes in this rendering — that touch the blood.

Now Carmat, a company based in Paris, has designed an artificial heart fashioned in part from cow tissue. The device, soon to be tested in patients with heart failure, is regulated by sensors, software and microelectronics.  Its power will come from two external, wearable lithium-ion batteries.

Fifteen years in development, the heart has been approved for clinical trials at cardiac surgery centers in Belgium, Poland, Saudi Arabia and Slovenia, where staff members are receiving training and patients are being screened, said Dr. Piet Jansen, medical director at Carmat.

In France, where the device is not yet cleared for human implantation, regulators have requested more animal tests, Dr. Jansen said; those tests are continuing.

Artificial hearts aren’t new, of course, but the Carmat heart is unusual in its design, said Dr. Joseph Rogers, an associate professor at Duke University and medical director of its cardiac transplant and mechanical circulatory support program. Surfaces in the new heart that touch human blood are made from cow tissue instead of artificial materials like plastic that can cause problems like clotting.

“The way they’ve incorporated biological surfaces for any place that contacts blood is a really nice advantage,” Dr. Rogers said. “If they have this design right, this could be a game changer.” He added that it could lessen the need for anticoagulation medicines. (Dr. Rogers has no financial connections to Carmat.)

This is the first artificial heart to use cow-derived materials — specifically, tissue from the pericardial sac that surrounds the heart. Biological tissue has been used in earlier mechanical blood pumps only in valves, Dr. Rogers said.

Thousands of people in the United States need a replacement heart, said Dr. Lynne Warner Stevenson, a professor at Harvard Medical School and director of the cardiomyopathy and heart-failure program at Brigham and Women’s Hospital in Boston. “It’s estimated that if we had enough donor hearts to go around, 100,000 to 150,000 people in the United States with heart failure would benefit,” she said. “Transplants work best, but we have only 2,000 or so adult hearts” that are available each year, she said. “It’s a huge problem.”

There are long-established options for patients while they await transplants, Dr. Stevenson said, including installing an artificial heart made by SynCardia until a donor heart is available.

When the natural heart is partly damaged or diseased, patients might keep it and have a mechanical aid implanted to bolster blood flow. Such pumps — especially those that aid the left side of the heart (LVAD)— are in wide use both as a bridge to a transplant and for lifetime therapy.

A totally artificial heart for extended use would be of great value, but it’s far too early to know if the Carmat heart, as yet untried in humans, will be that device. “The whole history of mechanical devices is that people thought they had devices where blood wouldn’t clot. But they didn’t,” Dr. Stevenson said.

Dr. Jansen said that the cost of the Carmat heart would be about $200,000 and that he did not expect it to be brought to market in Europe before the end of 2014. Once the company gains momentum with its European clinical studies, he said, it plans to start working through the regulatory process in the United States.

The Carmat heart has two chambers, each divided by a membrane. That membrane has cow tissue on one side — the side that is in contact with blood — and polyurethane on the other side, which touches the miniaturized pumping system of motors and hydraulic fluids that changes the membrane’s shape. (The motion of the membrane pushes the blood out to the body.) The embedded electronics and software adjust the rate of blood flow. Patients can wear the batteries under the arm in a holster, or in a belt, among other options.

Cow tissue is also used for the heart’s artificial valves, which were created by Dr. Alain Carpentier, a cardiac surgeon and a pioneer of heart valve repair who is also a co-founder of Carmat and its scientific director. Such valves have been used in heart-valve replacement surgery for decades. The cow tissue is chemically treated so that it is sterile and biologically inert.

The heart’s design and development relied heavily on aerospace testing strategies by EADS, the European Aeronautic Defense and Space Company, one of Carmat’s backers, Dr. Jansen said. Even so, duplicating the durability of a human heart will not be easy, said Dr. Robert Kormos, director of the artificial heart program at the University of Pittsburgh Medical Center and co-director of its heart transplant program.

“We can test these pumps on the bench in the laboratory, and in animals, but there is no true long-term data until you implant them in people for trials,” he said.

DR. JANSEN said that one design requirement for the heart was that it last five years. The company has been doing bench tests to see whether the new heart will stand up to that level of wear and tear. “Whether it lasts five years in the patient we will have to prove clinically,” he said.

Dr. Stevenson of Harvard is optimistic about the new device.

“Innovation is what we need,” she said. “This new device is exciting. I applaud the pioneers who developed it, and the patients and families who will go down this path for the first time.”

A version of this article appeared in print on July 14, 2013, on page BU3 of the New York edition with the headline: The Artificial Heart Is Getting a Bovine Boost.

SOURCE
An American designed Artificial Heart by ABIOMED, the Symphony model, assists in remodeling of heart tissue cells by design, as described in

Mechanical Circulatory Assist Devices as a Bridge to Heart Transplantation or as “Destination Therapy“: Options for Patients in Advanced Heart Failure

By Larry H Bernstein, MD, FCAP

A total artificial heart (TAH) is a device that replaces the two ventricles of the heart. Those who benefit from a TAH usually have end-stage heart failure. Since the condition is so severe that the heart can’t pump enough blood to meet the body’s needs, all treatments, except heart transplant, have failed.

The TAH is attached the atria, and mechanical valves are between the TAH and the atria functioning like the heart’s valves, controlling the flow of blood in pulmonary and systemic circulation.

Currently, the two types of TAHs are the CardioWest and the AbioCor. The main difference between these TAHs is that the CardioWest is connected to an outside power source.  The CardioWest has tubes that, through holes in the abdomen, run from inside the chest to an outside power source.

CardioWest Total Artificial Heart

Figure A shows a CardioWest TAH. Tubes exit the body and connect to a machine that powers the TAH and controls how it works.

Cardiowest_TAHt_Photo

The AbioCor TAH is completely contained inside the chest. A battery powers this TAH, and the battery is charged through the skin with a special magnetic charger. Energy from the external charger reaches the internal battery through an energy transfer device called transcutaneous energy transmission, or TET. An implanted TET device is connected to the implanted battery. An external TET coil is connected to the external charger. Also, an implanted controller monitors and controls the pumping speed of the heart.

AbioCor Total Artificial Heart

Figure B shows an AbioCor TAH and the internal devices that control how it works.

Abiomed_AB5000

A TAH usually extends life for months beyond what is expected with end-stage heart failure. It can keep one alive while waiting for a donor heart.  It is a challenge for surgeons to implant, and it can cause complications.  TAHs are devices used only in a small number of people.

There is a Difference Between Artificial Heart & Ventricular Assist Device

(see Michael Paul Maupin, eHow Contributor)

http://www.ehow.com/facts_6713118_difference-_amp_-ventricular-assist-devices.html#ixzz2a5BH465n

A ventricular assist device (VAD) utilizes the patient’s own heart, and it operates as a bridge device until a donor heart is procured for transplant. A TAH replaces a patient’s explanted heart.  The VAD is grafted onto a patient’s left ventricle, boosting the impaired ventricular function.  A VAD is either continuous or pulsatile in function. In a continuous VAD, blood is circulated through the heart like water through a hose.  A pulsatile VAD more mimics the expulsion of blood in rhythmic patterns.

http://www.ehow.com/facts_6713118_difference-_amp_-ventricular-assist-devices.html#ixzz2a5Bcbszh

On the other hand, an artificial heart completely replaces the human heart. The device functions in every way a healthy human heart would in the absence of cardiac disease.  The TAH creates the same pattern of squeeze-and-release seen in a real heart.

http://www.ehow.com/facts_6713118_difference-_amp_-ventricular-assist-devices.html#ixzz2a5Bn6xaR

As of 2010, the longest any human being has lived with an artificial heart is 21 months. In comparison, documentation exists in which a VAD recipient was still enjoying a vigorous quality of life after seven years.

Read more: http://www.ehow.com/facts_6713118_difference-_amp_-ventricular-assist-devices.html#ixzz2a5C1cPFV

The SynCardia temporary Total Artificial Heart

(An artificial heart displayed at the London Science Museum)

200px-Artificial-heart-london

http://www.wikipedia.com/Artificial Heart

An artificial heart is a device is typically used to bridge the time to heart transplantation, or to permanently replace the heart in case heart transplantation is impossible. The first artificial heart to be successfully implanted in a human was the Jarvik-7, designed and implemented by Robert Jarvik in 1982, but the first two patients to receive these hearts survived 112 (4 m) and 620 (21 m) days beyond their surgeries, respectively.[1]

Jarvik-7

It has already been stated that a TAH is distinct from a VAD, both used to support a failing heart. It is also distinct from a cardiopulmonary bypass machine, which is an external device used to provide the functions of both the heart and lungs, and it is used for only a few hours during cardiac bypass surgery.

Origin and Development of the Heart-Lung Bypass

A synthetic replacement for the severely failing heart would be expected to lower the need for heart transplants, because the demand for organs always greatly exceeds supply.  However, the first devices had problems with reactivity to synthetic materials and power supplies. For example, the Jarvik models were not created of a material that the human body would accept. This problem was improved when Dayton, Ohio’s Ival O. Salyer, along with various colleagues, developed a polymer material that the human body would not necessarily reject.

Prior to Jarvik-7, 41-year-old Henry Opitek made medical history in 1952 at Harper Hospital, Wayne State University in Detroit, Michigan when Dr. Forest Dewey Dodrill used the Dodrill-GMR heart machine to bypass Henry Opitek’s left ventricle for 50 minutes while he repaired the mitral valve. [2][3]  In this case In Dr. Dodrill’s post-operative report, he notes, “To our knowledge, this is the first instance of survival of a patient when a mechanical heart mechanism was used to take over the complete body function of maintaining the blood supply of the body while the heart was open and operated on.”[4]  A heart-lung machine was used in 1953 during a successful open heart surgery by Dr. John Heysham Gibbon, the inventor, who  performed the operation with the heart-lung substitute (distinct from an artificial heart substitute).

Designs of total artificial hearts

A precursor to the modern artificial heart pump was built by doctors William Sewell and William Glenn of the Yale School of Medicine in 1949 using an assortment of parts, and successfully bypassed the heart of a dog for more than an hour.[5]

The first patent for an artificial heart was held by Paul Winchell invented and Dr. Henry Heimlich (of the Heimlich Maneuver), which preceded the Jarvik heart.  On December 12, 1957, Dr. Willem Johan Kolff, the world’s most prolific inventor of artificial organs, implanted an artificial heart into a dog at Cleveland Clinic before he relocated to Salt Lake City, Utah, where there was established an Institute for artificial organs.  There, more than 200 physicians, engineers, students and faculty at the University of Utah Division of Artificial Organs developed, tested and improved Dr. Kolff’s artificial heart. To help manage his many endeavors, Dr. Kolff assigned project managers. Each project was named after its manager. Graduate student Robert Jarvik was the project manager for the artificial heart, which was subsequently renamed the Jarvik 7.

In 1958, Domingo Liotta initiated the studies of TAH replacement at Lyon, France, and in 1959–60 at the National University of Córdoba, Argentina. He presented his work at the meeting of the American Society for Artificial Internal Organs held in Atlantic City in March 1961. At that meeting, Dr. Liotta described the implantation of three types of orthotopic (inside the pericardial sac) TAHs in dogs, each of which used a different source of external energy: an implantable electric motor, an implantable rotating pump with an external electric motor, and a pneumatic pump.[6][7]

In 1964, the National Institutes of Health started the Artificial Heart Program, with the goal of putting a man-made organ into a human by the end of the decade.[8]  The first success followed in February 1966, when Dr. Adrian Kantrowitz performed the world’s first permanent implantation of a partial mechanical heart (left ventricular assist device) at Maimonides Medical Center, Brooklyn, NY.[9]  He relocated to Detroit’s Sinai and Wayne Stae University.

In 1981, Dr. William DeVries submitted a request to the FDA to implant the Jarvik 7 into a human being. On December 2, 1982, Dr. Kolff implanted the Jarvik 7 artificial heart into Barney Clark, who was suffering from severe congestive heart failure. With Clark tethered to an external 400 lb pneumatic compressor, he suffered prolonged periods of confusion, a number of instances of bleeding, and asked several times to be allowed to die.[10]

Total Artificial Heart (TAH)

On April 4, 1969, Domingo Liotta and Denton A. Cooley replaced a dying man’s heart with a mechanical heart inside the chest at The Texas Heart Institute in Houston as a bridge for a transplant. The patient woke up and recovered well. After 64 hours, the pneumatic-powered artificial heart was removed and replaced by a donor heart. However thirty-two hours after transplantation, the patient died of what was later proved to be an acute pulmonary infection, extended to both lungs, caused by fungi, most likely caused by an immunosuppressive drug complication.[11]

The original prototype of Liotta-Cooley artificial heart used in this historic operation is prominently displayed in the Smithsonian Institution’s National Museum of American History “Treasures of American History” exhibit in Washington, D.C..[12]

Permanent Pneumatic Total Artificial Heart (TAH)

The eighty-fifth clinical use of an artificial heart designed for permanent implantation rather than a bridge to transplant occurred in 1982 at the University of Utah. Artificial kidney pioneer Dr. Willem Johan Kolff started the Utah artificial organs program in 1967.[13] There, physician-engineer Dr. Clifford Kwan-Gett invented two components of an integrated pneumatic artificial heart system: a ventricle with hemispherical diaphragms that did not crush red blood cells (a problem with previous artificial hearts) and an external heart driver that inherently regulated blood flow without needing complex control systems.[14]   Dr. Robert Jarvik combined several modifications of the original: an ovoid shape to fit inside the human chest, a more blood-compatible polyurethane developed by biomedical engineer Dr. Donald Lyman, and a fabrication method by Kwan-Gett that made the inside of the ventricles smooth and seamless to reduce dangerous stroke-causing blood clots.[16]

Today, the modern version of the Jarvik 7 is known as the SynCardia temporary CardioWest Total Artificial Heart. It has been implanted in more than 800 people as a bridge to transplantation.

Artificial Heart Cardiowest TAH-t (improvement of Jarvik-7)

In the mid-1980s, artificial hearts were powered by dishwasher-sized pneumatic power sources whose lineage went back to Alpha-Laval milking machines and required two catheters to cross the abdominal wall to carry the pneumatic pulses to the implanted heart. The National Heart, Lung, and Blood Institute opened a competition for implantable electrically powered artificial hearts funding  Cleveland Clinic in Cleveland, Ohio; the College of Medicine of Pennsylvania State University (Penn State Hershey Medical Center) in Hershey, Pennsylvania; and AbioMed, Inc. of Danvers, Massachusetts.

Abiomed_AB5000

Polymeric trileaflet valves ensure unidirectional blood flow with a low pressure gradient and good longevity. State-of-the-art transcutaneous energy transfer eliminates the need for electric wires crossing the chest wall.

AbioCor

The first AbioCor to be surgically implanted in a patient was on July 3, 2001.[17] The AbioCor is made of titanium and plastic with a weight of two pounds, and its internal battery can be recharged with a transduction device that sends power through the skin.[17] The internal battery lasts for a half hour, and a wearable external battery pack lasts for four hours.[18] The FDA announced on September 5, 2006, that the AbioCor, intended for critically ill patients who can not receive a heart transplant[19]  could be implanted after the device had been tested on 15 patients.[19]  But limitations of the current AbioCor are that its size makes it suitable for only about 50% of the male population, and its useful life is only 1–2 years.[20]  AbioMed designed a smaller, more stable heart, the AbioCor II, by combining its valved ventricles with the control technology and roller screw developed at Penn State. This pump, which should be implantable in most men and 50% of women with a life span of up to five years,[20] had animal trials in 2005, and the company hoped to get FDA approval for human use in 2008.[21]

Intrathoracic Pump (LVAD)

On July 19, 1963, E. Stanley Crawford and Domingo Liotta implanted the first clinical Left Ventricular Assist Device (LVAD) at The Methodist Hospital in Houston, Texas, in a patient who had a cardiac arrest after surgery. The patient survived for four days under mechanical support but did not recover from the complications of the cardiac arrest.

On April 21, 1966, Michael DeBakey and Liotta implanted the first clinical LVAD in a paracorporeal position (where the external pump rests at the side of the patient) at The Methodist Hospital in Houston, in a patient experiencing cardiogenic shock after heart surgery. The patient developed neurological and pulmonary complications and died after few days of mechanical support. In October 1966, DeBakey and Liotta implanted the paracorporeal Liotta-DeBakey LVAD in a new patient who recovered well and was discharged from the hospital after 10 days, marking the first successful use of an LVAD for postcardiotomy shock.

Recent developments

In June 1996, a 46-year-old Taiwanese American Mr. Yao ST received the world’s first total artificial heart implantation done by Dr. Jeng Wei at Cheng-Hsin General Hospital[26] in the Republic of China (Taiwan). This technologically advanced pneumatic Phoenix-7 Total Artificial Heart was manufactured by a Taiwanese dentist Kelvin K. Cheng, a Chinese physican T. M. Kao and colleagues at the Taiwan TAH Research Center in Tainan, Republic of China (Taiwan). With this experimental artificial heart, the patient’s BP was maintained at 90-100/40-55 mmHg and cardiac output at 4.2-5.8 L/min. After 15 days of bridging, Mr. Yao received combined heart and kidney transplantation. As of March 2013, he is still very well and is currently living in San Francisco, USA. Mr. Yao ST is the world first successful combined heart and kidney transplantation patient after bridging with total artificial heart.[27]

In August 2006, an artificial heart was implanted into a 15-year-old girl at the Stollery Children’s Hospital in Edmonton, Alberta. It was intended to act as a temporary fixture until a donor heart could be found. Instead, the artificial heart (called a Berlin Heart) allowed for natural processes to occur and her heart healed on its own. After 146 days, the Berlin Heart was removed, and the girl’s heart was able to function properly on its own.[22]

On December 16, 2011 the Berlin Heart, a ventricular assist intended for children age 16 and under, gained U.S. FDA approval. The device has since been successfully implanted in several children including a 4-year-old Honduran girl at Children’s Hospital Boston.[23]

In 2012, a study published in the New England Journal of Medicine compared the Berlin Heart to extracorporeal membrane oxygenation (ECMO) and concluded that “a ventricular assist device available in several sizes for use in children as a bridge to heart transplantation [such as the Berlin Heart] was associated with a significantly higher rate of survival as compared with ECMO.”[24] The study’s primary author, Dr. Charles D. Fraser, Jr., surgeon in chief at Texas Children’s Hospital, explained: “With the Berlin Heart, we have a more effective therapy to offer patients earlier in the management of their heart failure. ..This is a giant step forward.” [25]

Total artificial heart (TAH) invention abroad

On October 27, 2008, French professor and leading heart transplant specialist Alain F. Carpentier announced that a fully implantable artificial heart will be ready for clinical trial by 2011 and for alternative transplant in 2013. It was developed and will be manufactured by him, biomedical firm CARMAT SA, and venture capital firm Truffle Capital. The prototype uses embedded electronic sensors and is made from chemically treated animal tissues, called “biomaterials”, or a “pseudo-skin” of biosynthetic, microporous materials.[28] According to an interview of the professor Alain Carpentier in Paris (2011), a number of leading cardiac clinics already conducted successful partial replacement of the organic components of the artificial heart, for example, replacing valves, large vessels, atria, ventricles. In addition to cardio-surgery, there is the medico-psychological aspect of an artificial heart. A quarter of patients in the postoperative period after prosthetic valvular surgery developed specific psychopathological symptoms, which later received the name Skumin syndrome in 1978. It is possible that a similar problem will be discovered when conducting large-scale operations to implant an artificial heart.[29]

Another U.S. team with a prototype called 2005 MagScrew Total Artificial Heart, including Japan and South Korea researchers are racing to produce similar projects.[30][31][32]

In August 2010, 50-year-old Angelo Tigano of Fairfield, New South Wales, Australia, had his failing heart removed in a five-hour operation and it was replaced with the SynCardia temporary Total Artificial Heart by surgeon Dr Phillip Spratt, head of the heart transplant unit at St Vincent’s Hospital, Sydney.[33]

On 12 March 2011, an experimental artificial heart was implanted in 55-year-old Craig Lewis at The Texas Heart Institute in Houston by Drs. O. H. Frazier and William Cohn. The device is a combination of two modified HeartMate II pumps that is currently undergoing bovine trials.[34]

On 9 June 2011, 40 year old Matthew Green was implanted with the SynCardia temporary Total Artificial Heart in a seven hour operation at Papworth Hospital. He was the first Briton to leave hospital supported by an artificial Heart on 2 August 2011.[35]

A centrifugal pump[36][37] or an axial-flow pump[38][39] can be used as an artificial heart, resulting in the patient being alive without a pulse.

Imachi et al. described a centrifugal artificial heart which alternately pumps the pulmonary circulation and the systemic circulation, causing a pulse.[40]

Heart Assist Devices

Patients who have some remaining heart function but who can no longer live normally may be candidates for ventricular assist devices (VAD), which do not replace the human heart but complement it by taking up much of the function.

The first Left Ventricular Assist Device (LVAD) system was created by Domingo Liotta at Baylor College of Medicine in Houston in 1962.[41]

Another VAD, the Kantrowitz CardioVad, designed by Adrian Kantrowitz boosts the native heart by taking up over 50% of its function.[42] Additionally, the VAD can help patients on the wait list for a heart transplant. In a young person, this device could delay the need for a transplant by 10–15 years, or even allow the heart to recover, in which case the VAD can be removed.[42] The artificial heart is powered by a battery that needs to be changed several times while still working.

The first heart assist device was approved by the FDA in 1994, and two more received approval in 1998.[43] While the original assist devices emulated the pulsating heart, newer versions, such as the Heartmate II,[44] developed by The Texas Heart Institute of Houston, provide continuous flow. These pumps (which may be centrifugal or axial flow) are smaller and potentially more durable and last longer than the current generation of total heart replacement pumps. A major advantage of a VAD is that the patient keeps the natural heart, which may provide enough support to keep the patient alive until a solution to the problem is implemented.

Impella 2.5 cardiac assist device in LV

Suffering from end-stage heart failure, former Vice President Dick Cheney underwent a procedure in July 2010 to have a VAD implanted at INOVA Fairfax Hospital, in Fairfax Virginia. In 2012, he received a heart transplant at age 71 after 20 months on a waiting list.

REFERENCES

1^ American Heart Association. The Mechanical Heart celebrates 50 lifesaving years. 22 10 2002. 9 Feb 2008 <http://www.americanheart.org/presenter.jhtml;jsessionid=EFNP3NSFUBXLICQFCXQCDSQ?identifier=3005888>

2^ Stephenson, Larry W, et al. “The Michigan Heart: The World’s First Successful Open Heart Operation?” Journal of Cardiac Surgery 17.3 (2002): 238–246.

3^ Lavietes, Stuart. William Glenn, 88, Surgeon Who Invented Heart Procedure, The New York Times, March 17, 2003. Accessed May 21, 2009.

4^ Artificial Heart in the chest: Preliminary report. Trans. Amer. Soc. Inter. Organs, 1961, 7:318

5^ Ablation experimentale et replacement du coeur par un coer artificial intra-thoracique. Lyon Cirurgical, 1961, 57:704

6^ Sandeep Jauhar, M.D., Ph.D.: The Artificial Heart. New England Journal of Medicine (2004): 542–544.

7^ http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2676518/, NCBI In Memoriam Dr. Adrian Kantrowitz

8^ Barron H. Lerner, MD, PhD (December 1, 2007). “The 25th Anniversary of Barney Clark’s Artificial Heart”. Celebrity Health. HealthDiaries.com. Retrieved 15 November 2010.

9^ Orthotopic cardiac prosthesis for two-staged cardiac replacement. Am J Cardio 1969; 24:723–730.

10^ “Treasures of American History”, National Museum of American History

11^ Spare Parts: Organ Replacement in American Society. Renee C. Fox and Judith P. Swazey. New York: Oxford University Press; 1992, pp. 102–104

12^ Kwan-Gett CS, Van Kampen KR, Kawai J, Eastwood N, Kolff WJ. “Results of total artificial heart implantation in calves.” Journal of Thoracic and Cardiovascular Surgery. 1971 Dec; 62(6):880–889.

13^ “Winchell’s Heart”. Time. March 12, 1973. Retrieved April 25, 2010.

14^ Kolff

15^ a b “Patient gets first totally implanted artificial heart”. CNN.com. 2001-07-03. Archived from the original on 7 June 2008. Retrieved 2008-07-13.

16^ “AbioCor FAQs”. AbioMed. Archived from the original on 3 July 2008. Retrieved 2008-07-13.

17^ a b “FDA Approves First Totally Implanted Permanent Artificial Heart for Humanitarian Uses”. FDA.gov. 2006-09-05. Retrieved 2008-07-13.

18^ a b “Will We Merge With Machines?”. popsci.com. 2005-08-01. Archived from the original on 19 July 2008. Retrieved 2008-07-13.

19^ “14th Artificial Heart Patient Dies: A Newsmaker Interview With Robert Kung, PhD”. medscape.com. 2004-11-11. Retrieved 2008-07-13.

20^ Capital Health: One year later: Berlin Heart bridges patient back to health (August 28, 2007), Capital Health, Edmonton (archived from [1] the original) on 2007-10-01).

21^ approved Berlin Heart helps patients waiting for a transplant (December 30, 2011), Children’s Hospital Boston.

22^ http://www.nejm.org/doi/pdf/10.1056/NEJMoa1014164

23^ http://www.texaschildrens.org/About-Us/News/Berlin-Heart-NEJM-2012/

24^ Cheng-Hsin General Hospital

25^ J. Wei, K. K. Cheng, D. Y. Tung, C. Y. Chang, W. M. Wan, Y. C. Chuang: Successful Use of Phoenix-7 Total Artificial Heart. Transplantation Proceedings, 1998, 30:3403-4

26^ The Carmat Heart,- The technology behind the prosthesis

27^ “About artificial heart”. Heart For Your Soul. Retrieved 2011-02-19.

28^ Total artificial heart to be ready by 2011: research team, news.yahoo.com

29^ Scientists develop artificial heart that beats like the real thing, timesonline.co.uk

30-^ Total artificial heart to be ready by 2011: research team, afp.google.com

31^ Sydney man receives Total Artificial Heart, dailyTelegraph.com.au

32^ Berger, Eric. “New artificial heart ‘a leap forward'”. Houston Chronicle. Retrieved 23 March 2011.

33^ “Plastic heart gives dad Matthew Green new lease of life”. BBC News. August 2, 2011.

34^ Black, Rosemary (January 5, 2011). “Former vice president Dick Cheney now has no pulse”. Daily News (New York).

35^ http://www.scribd.com/doc/21241693/Pulseless-Pumps-Artificial-Hearts

36^ The pulseless life

37^ Dan Baum: No Pulse: How Doctors Reinvented The Human Heart. 2012-02-29.

38^ ‘#A new pulsatile total artificial heart using a single centrifugal pump., K. Imachi, T. Chinzei, Y. Abe, K. Mabuchi, K. Imanishi, T. Yonezawa, A. Kouno, T. Ono, K. Atsumi, T. Isoyama, et al.. Institute of Medical Electronics, Faculty of Medicine, University of Tokyo, Japan.

39^ Prolonged Assisted circulation after cardiac or aortic surgery. Prolonged partial left ventricular bypass by means of intracorporeal circulation. This paper was finalist in The Young Investigators Award Contest of the American College of Cardiology. Denver, May 1962 Am. J. Cardiol. 1963, 12:399–404

40^ a b Mitka, Mike. “Midwest Trials of Heart-Assist Device.” Journal of the American Medical Association 286.21 (2001): 2661.

41^ FDA APPROVES TWO PORTABLE HEART-ASSIST DEVICES at FDA.gov

42^ An Artificial Heart That Doesn’t Beat at TechnologyReview.com

How does an artificial heart work?

The development and operation of these life-saving devices requires understanding and application of a combination of biology, materials science and physics.
Institute of Physics website  http://www.physics.org/article-questions.asp?id=74

The artficial heart

Image: Syncardia Systems

The right atrium collects blood and the right ventricle then pumps it to the lungs where it is oxygenated. The blood is then picked up by the left atrium and distributed around the body and brain by the left ventricle. Each side of the heart has a pair of valves – one pair per lung – controlling the flow of blood.

Artificial hearts can now completely, if temporarily, replace the ventricles and valves with a device made of plastic or other man-made materials, which does the job of pumping blood around.

The type of artificial heart made by Syncardia Systems, works by using a pump carried externally in a backpack – previously, patients would have to be connected to a large, immobile pump and would not have the freedom to move around.

Cardiowest_TAHt_Photo

The NHS Choices website explains that tubes connecting the heart to the pump “send pulses of air into two expandable, balloon-like sacs in the artificial ventricles, forcing out blood in much the same way that a beating heart would”.

Other models such as that produced by AbioMed use an internal pump and battery, which can be charged via transcutaneous energy transmission – a method of transferring power under the skin without having to penetrate it, thereby decreasing the chance of infection.

Energy transmission

In the artificial hearts produced by AbioMed, an electronics package is implanted in the abdomen of the recipient of the transplant to monitor and control the pumping of the heart.

Power is supplied from an external source to components under the skin, without penetrating it, using inductive electromagnetic coupling – the same principle as used by transformers to transfer electricity between different circuits, as in the national grid.

At their simplest, systems of transcutaneous energy transmission will use an external power supply connected to an external coil of wire, generating a magnetic field in it. This, in turn, produces an induced voltage in a second coil implanted under the skin, and a rectifier is used to change this alternating current into direct current that can be used to power the electronics of the heart and its controller.

Though simple in theory, in practice there are complications that arise from the need to keep the two coils aligned correctly as the patient moves, in delivering the correct level of power so that there is no excess dissipated as heat to potentially damage surrounding tissue in the patient’s body, and in making the components small enough to be carried around without too much discomfort.

Monitoring blood flow

A replacement heart needs to be able to monitor the flow of blood to regulate its pumping and ensure that the correct amount of blood is delivered around the body.

Quicker pumping is required when the transplant recipient is more active, whereas the opposite is true while he or she is resting.

Blood-flow monitors make use of ultrasound – they bounce high-frequency sound waves off blood cells coming out of the heart, the volume and speed can be measured using similar basic principles to those behind radar.

Ultrasound is used because it can monitor the flow of blood without having to be in contact with it.

Appropriate materials

Artificial hearts need to be made of light but durable materials – the Syncardia version is plastic whereas that made by AbioMed is a combination of titanium and a specially developed polyurethane, called ‘Angioflex’.

Although the Abiomed heart is designed to have as few moving parts as possible, those that it does have are made from Angioflex and are tested to ensure that they are safe for contact with blood and capable of withstanding beating 100 000 times a day for years on end.

Materials scientists can develop substances with specific properties by manipulating the constituent elements and the way in which they are processed. Materials are characterised using various techniques from condensed-matter physics including electron microscopy, x-ray diffraction and neutron diffraction.

Because they were still quite large, the first devices produced were limited to around half the male population – those with the largest chest cavities. A newer, smaller, model is intended to extend their availability to smaller people.

An artificial heart being produced by the French medical company Carmat and expected to be available by 2013 will use chemically treated animal tissue to help avoid rejection by the host’s immune system. Aerospace engineers from Airbus were also involved in its development.

Artificial hearts combine, and improve upon, many existing physics ideas to produce a piece of technology that saves lives – although they are currently only approved as a stopgap until a donor heart can be found.

Expressions of Experience: Heart Assist Devices

Video interview with O. H. “Bud” Frazier, MD; Chief, Center for Cardiac Support; Director, Cardiovascular Surgery Research; and Co-Director, Cullen Cardiovascular Research Laboratories, at Texas Heart Institute.

 O. H. “Bud” Frazier, MD, on his inspiration for developing treatments for heart failure at the Texas Heart Institute.

The Texas Heart Institute is a world leader in the development, testing and application of heart assist devices. Our goal for the surgical research conducted here is to develop and determine the best assist device to use for each individual patient. Devices may be referred to as mechanical assist devices, ventricular assist devices (VAD), left ventricular assist devices (LVAD), total artificial hearts (TAH), or simply heart pumps.

January 23, 2013

Keeping hearts pumping   Dr. Bud Frazier and Dr. Billy Cohn with heart pump BiVacor. [Photo credit Mayra Beltran, Houston Chronicle]

Doctors push the limits of heart-pump technology in an effort to save lives. Dr. Bud Frazier often tells a story about when he was a medical student in the 1960s . . . Frazier had this thought: If I can keep a man alive with my hand, why can’t we make a pump that we can pull off of the shelf to do the same thing? Dr. Billy Cohn, another physician who works at the cutting edge of heart pump technology, likes to use the history of human flight as an analogy for the evolution in his field. Experimenters in both domains had to give up the idea of bio-mimicry to advance the technology. “It is similar to when man first tried to build a flying machine with flapping wings that mimic the birds. It is obvious now that fixed wings were the way to go,” he says. “We think it is the same with the nonpulsatile pump, which, because it has only one moving part, is much more durable.” – Houston Chronicle [Photo credit Mayra Beltran]

January 13, 2013

BiVACOR artificial heart device

Australian engineer Daniel Timm’s revolutionary device to be developed at THI. “I think we’re beyond the Kitty Hawk stage with this,” – Drs. Bud Frazier and Billy Cohn. Read Eric Berger’s Houston Chronicle article.

November 20, 2012

FDA Approves HeartWare LVAD for HF

The FDA gave the green light for the HeartWare Ventricular Assist System as a bridge to heart transplantation in patients with heart failure. “The miniaturized device with an integrated inflow cannula is placed within the pericardial sac . . . simplifying the surgical insertion,” said O.H. “Bud” Frazier, MD, of Texas Heart Institute. Read the full story from medpagetoday.com.

Drs. Bud Frazier & Billy Cohn TEDMED 2012

Is this the future of artificial hearts?

At TEDMED 2012, Bud Frazier and Billy Cohn of the Texas Heart Institute preview a continuous-flow heart pump with minimal parts that works via a screw pump. Watch the VIDEO.

Cameron Engineers, THI researchers collaborate on heart pump

Engineers and scientists at Cameron Manufacturing & Engineering have worked with THI researchers in developing a new heart pump. On March 1, 2012, Cameron donated $500,000 to Texas Heart Institute at St. Luke’s Episcopal Hospital to develop a prototype heart pump which could save countless lives.

Can Tiny Heart Pump Limit Heart Muscle Damage after STEMI?

Interventional cardiologists affiliated with THI at St. Luke’s recently implanted the first two patients in the nation with a tiny heart pump in a feasibility trial to determine the pump’s potential to limit damage to heart muscle following a STEMI (ST-elevation myocardial infarction). Read the full news release to learn about the FDA-approved trial and the first enrolled patients. (November 2011)

Miniature Heart Pump: Smaller May Be Better!

Dr. William “Billy” Cohn discusses recent advances in left ventricular assist devices (LVADs) and other mechanical circulatory blood pumps as they get smaller and more adaptable to individual patients. View the video of his presentation at the Pumps & Pipes Conference (15 minutes, December 2010).

Video: Artificial hearts giving hope, saving lives. (August 19, 2011)

imeplla-LD-video

Companion 2 and Freedom Drivers

C2 Driver Supports Total Artificial Heart Patients in the Hospital Until They Are Stable and Eligible for the Freedom® Portable Driver

The Companion 2 Driver, which can be docked in the Hospital Cart or Caddy, powers the SynCardia Total Artificial Heart from implant until the patient’s condition stabilizes. Once stable, patients who are eligible can be switched to the smaller, wearable Freedom® portable driver. The Companion 2 Driver, which can be docked in the Hospital Cart or Caddy, powers the SynCardia Total Artificial Heart from implant until the patient’s condition stabilizes. Once stable, patients who are eligible can be switched to the smaller, wearable Freedom® portable driver.

The Companion 2 (C2) Driver System, which powers the SynCardia temporary Total Artificial Heart in the hospital, was selected as the Silver Winner in the Critical-Care and Emergency Medicine Products category of the Medical Design Excellence Awards (MDEA) held on June 19 in Philadelphia.

“It is a tremendous honor to have one of our products selected as a winner for the second consecutive year,” said Michael Garippa, SynCardia Chairman/CEO/President. “Our Freedom® portable driver, the world’s first wearable power supply for the Total Artificial Heart, was selected as the Bronze Winner in the same category last year. These drivers support Total Artificial Heart patients from implant with the C2 through discharge with the Freedom.”

Once stable, patients who are eligible can be switched to the 13.5-pound Freedom portable driver. Patients who meet discharge criteria can then leave the hospital and wait for a matching donor heart at home and in their communities.

The Medical Design Excellence Awards are the industry’s premier design awards competition and is the only awards program exclusively recognizing contributions and advances in the design of medical products. Entries were evaluated on the basis of their design and engineering features, including innovative use of materials, user-related functions that improve healthcare delivery and change traditional medical attitudes or practices, features that provide enhanced benefits to the patient, and the ability to overcome design and engineering challenges to meet clinical objectives.

About the SynCardia temporary Total Artificial Heart

The SynCardia Total Artificial Heart is currently approved as a bridge to transplant for people suffering from end-stage heart failure affecting both sides of the heart (biventricular failure). There have been more than 1,200 implants of the Total Artificial Heart, accounting for more than 315 patient years of life on the device. It is the only device that eliminates the symptoms and source of end-stage biventricular failure. The TAH provides immediate, safe blood flow of up to 9.5 liters per minute through each ventricle. This high volume of blood flow helps speed the recovery of vital organs, helping make the patient a better transplant candidate.

Artificial Heart Devices used at Barnes-Jewish Hospital Washington University, St. Louis

The cardiac surgeons at the Barnes-Jewish & Washington University Heart & Vascular Center are one of the leading heart surgery teams in the nation. Our permanent and temporary artificial heart devices can dramatically improve symptoms of late-stage heart failure, and sometimes even provide long-term treatment.

Mechanical Circulatory Support

The field of mechanical circulatory support in the management of patients with heart failure has seen significant advances over the past few years.  The heart failure program at Washington University and Barnes-Jewish Hospital utilizes the latest technology for both temporary and long-term mechanical support of the heart failure patient.

Temporary Support

Patients that experience severe symptoms of heart failure that cannot be stabilized with medical therapy may require a temporary support device. These implantable devices are usually placed in a cardiac catheterization lab by interventional cardiologists and/or cardiac surgeons. Temporary support devices typically serve to stabilize the patient until long-term mechanical support can be introduced. These devices include:

  • intra-aortic balloon pump
  • Impella 2.5, 4.0 and 5.0
  • TandemHeart
  • Thoratec CentriMag

Long-Term Mechanical Support

Patients may require long-term circulatory support either as a bridge to a heart transplant (bridge-to-transplant, or BTT) or as long-term treatment of heart failure in non-transplant candidates (destination therapy, or DT).  The mechanical assist device program at Barnes-Jewish & Washington University Heart & Vascular Center is one of the largest programs in the country. The program has a multidisciplinary group of dedicated specialists to ensure excellent outcomes in this patient population. Currently available devices include both left ventricular assist devices (LVAD) and the total artificial heart:

  • HeartMate II
  • HeartWare HVAD
  • Syncardia Total Artificial Heart 

The cardiac surgeons at the Barnes-Jewish & Washington University Heart & Vascular Center are one of only 13 surgical teams in the country to implant the CardioWest™ temporary Total Artificial Heart (TAH-t) as a bridge-to-transplantation in specific heart transplant candidates.

The CardioWest™ TAH-t is an improved version of the Jarvik-7 Artificial Heart, which was first implanted in 1982. This unique technology allows us to treat patients who would not survive without full circulatory support.  The CardioWest™ TAH-t completely replaces the patient’s diseased heart with a goal of restoring normal blood pressure, increasing cardiac output and giving organs such as the kidney and liver a chance to recover. As a result, patients become better candidates for transplantation.  The program is currently involved in testing the Freedom portable driver which will allow patients to leave the hospital following implantation of the TAH.

cardiowest_tah

An American designed Artificial Heart by ABIOMED, the Symphony model, assists in remodeling of heart tissue cells by design, as described in

Impella_Thumb_small 5.0 for heart failure

Heart Remodeling by Design – Implantable Synchronized Cardiac Assist Device:Abiomed’s Symphony

Table IABT vs Impella

SOURCE

Heart Remodeling by Design – Implantable Synchronized Cardiac Assist Device:Abiomed’s Symphony

Part  II  

Comparison of the Cardiac Operations involved in an Organ Transplant of a Donor’s Heart vs Implantation of an Artificial Heart

By Justin D Pearlman, MD, PhD, FACC 

A heart donor is a patient deemed brain dead who had forethought (a designation on the driver’s license) or a designated decision-maker (Healthcare Proxy) elected to make the heart available to help save another person’s life. Every tissue in the body has proteins that render a unique signature or “smell” and every patient has a limited set of markers it will accept without a fight (the histocompatibility complex, and in particular, the human leukocyte antigen).  The immune system is a major part of the body’s defenses against infection and abnormal tissues (cancer) which consists of cells trained to attack foreign protein chemistry and/or mark it for destruction with anti-bodies.

I. Heart Transplant of a Human Donor

The steps for heart transplant include:

(1) demonstration of need,

(2) identification of suitable donors,

(3) surviving while waiting for a suitable donor,

(4) surviving the removal of the damaged heart or heart and lungs to make room for the replacement (accomplished with a bypass pump),

(5) survival of the donor heart (or heart and lungs) pending preparation of the patient for receipt of the transplant,

(6) inserting the donor heart (or heart and lungs),

(7) taking the patient off the bypass pump and directing circulation through the transplant,

(8) recovery and healing,

(9) establishing and maintaining sufficient immune suppression to avoid rejection of the transplant,

(10) monitoring for functional losses or rejection.

(11) monitoring for cancer or infection,

(12) resuming enjoyment of life. Each year in the United states 800 patients die waiting for a transplant, while 2300 receive transplants.

The first heart transplant is credited to Vladimer Demikhov when he transplanted dog hearts in 1946; Dr. Shumway reported successful transplantation of the heart in 1966, and Dr. Christiaan Barnard performed the operation successfully on humans in 1967 (that patient lived 18 days). Replacing the heart with a donor heart is called orthotopic (true location) heart transplantation.  Durability of a transplant improved markedly with the approval of the immune suppression medication ciclosporine. NOVA has created a shockwave video demonstrating the heart transplant operation: view video.

The actual transplantation requires only five or six lines of sutures (stitches):

  • inferior and superior vena cava (venous input to the right ventricle),
  • the main (or left and right) pulmonary arteries (delivery of blood from right ventricle to the lungs),
  • the upper half of the original left atrium to route the 3-5 pulmonary veins to the left ventricle (return of blood from the lungs), and the
  • aorta (to route blood from the left ventricle to the brain and body).

The donor heart harvesting typically includes a segment of the superior and inferior vena cava which feed

  • the right atrium,
  • the four pulmonary veins which feed the left atrium, and
  • a portion of the pulmonary artery, and
  • the aorta.

The heart is chilled to minimized its metabolic demands while it is disconnected and transferred.

The recipient heart explantation (removal of the bad heart) after the patient is supported by a bypass pump involves:

  • cannulation (tubing placement) into the aorta,
  • the superior vena cava and
  • the inferior vena cava, then
  • explantation leaving the posterior aspect of the left atrium and the posterolateral aspect of the right atrium in the recipient patient.

The left and right pulmonary veins of the donor are divided and the veins are threaded into the retained portion of the recipient left atrium. The inferor vena cava, superior vena cava, pulmonary artery, and aorta are respectively anastomosed (sewed onto the truncated portion of the corresponding native vessels end-to-end). Clots and air are flushed out and the patient is taken off bypass pump.

II. Artificial Heart:  Implant of an Assist Device

Implantation of ventricular assist device or an artificial heart is easier than a heart transplant, but it has been challenging to match nature’s ability to place the pump and keep it powered and regulated. Also durability is a major issue. The most common ventricular assist device, the intra-aortic balloon pump, is a temporizing tool to sustain a patient for just a few days while alternatives are evaluated and pursued.The steps for implanting a ventricular assist pump can be as simple as:

(1) cleaning and applying antiseptics to the skin,

(2) placing a needle in the femoral artery at the groin area,

(3) threading a wire into the artery,

(4) threading a series of hollow tubes over the wire (dilators) and leaving the largest in place (introducer),

(5) threading a catheter-pump  through the introducer and up the aorta to the desired location,

(6) synchronizing the pump the the cardiac cycle by electrocardiogram.

If the device is an intra-aortic balloon pump (IABP) then the device is advanced to the aortic arch so that an inflatable balloon expands and contracts within the aorta from the aortic arch down to just above the renal arteries. The IABP is designed to deflate when the heart contracts (systole), to make space for blood ejecting from the failing heart (afterload reduction), then inflate when the heart relaxes (diastole), effectively converting a blood pressure of 120/80 to 80/120. The coronary arteries are stressed during systole and receive their blood supply during diastole, so the diastolic augmentation (inflation of the balloon during heart relaxation) markedly improves blood delivery to the coronary arteries, which is very helpful when the coronary arteries are diseased and not well suited for immediate repair. The actions of the balloon damage blood cells and can rupture the aorta. The blood cell damage activates clotting, so full anticoagulation is required.
If the device is an Impella catheter pump, then the distal end (farthest into the patient) crosses the aortic valve into the left ventricle to draw blood from there and deliver it beyond the heart in the descending aorta.
 The ins and outs of the IABP. Shows diastole and systole. The IABP rapidly shuttles helium gas in and out of the balloon, which is located in the descending aorta. The balloon is inflated at the onsetImpellaIABP  www.fda.gov/MedicalDevices/Safety                           Impella  www.abiomed.com

Devices draw their input from

  • arterial blood (aorta or femoral artery)
  • venous blood (vena cava), or
  • a puncture wound created in the apex of the left ventricle of the heart

The next example of a ventricular assist device to consider during open heart surgery, is the bypass pump that is used during most cardiovascular surgeries, and in particular during heart or heart-lung transplant. The bypass pump relies on a tube (cannula) placed in a large source of deoxygenated blood

  • the right atrium,
  • the inferior vena cava or
  • the femoral vein

to draw its input blood from there (diverting it from the heart), and a second cannula placed in a large artery (the aorta or the femoral artery) for output. The blood passes out of the patient (extra-corporeal) to a very large mechanical pump, that typically consists of compressible tubing and rollers to minimize trauma to the blood, passing the red cells of the blood by membranes that enable uptake of oxygen. Despite the attempts not to damage the blood, blood does get damaged, so full anti-coagulation is required. The anti-coagulation consists of intravenous heparin to bind the coagulation factors. When the patient comes off the pump, the heparinization of the blood is counteracted by intravenous protamine sulfate. Also the blood is cooled because low temperatures slow down metabolism and make the cells of the body less needy during the sub-optimal circulation support. Cooled blood has increased viscosity, offset by dilution of the blood with saline (Normal Saline, isotonic solution,  w/v of NaCl, about 300 mOsm/L or 9.0 g per liter). As the pump takes over circulation, the blood supply to the heart is clamped off (cross-clamp), at which point the surgeon can work to repair the heart (valve repair, valve replacement, aorta graft, coronary grafts) or replace the heart or heart and lungs.

Artificial hearts are extensions of the concepts above, and differ primarily in

  • how the pump in energized and
  • how the pump is regulated.

An artificial heart is designed for long term use so it must be more gentle on the blood. In Part I: Alternative Models of Artificial Hearts, US and Europe, in this article, we reported on the Latest Innovations in Alternative Models of Artificial Hearts, the Carmat Heart, it is unusual in its design, said Dr. Joseph Rogers, an associate professor at Duke University and medical director of its cardiac transplant and mechanical circulatory support program. Surfaces in the new heart that touch human blood are made from cow tissue instead of artificial materials like plastic that can cause problems like clotting, it will decrease the anticoagulation dependence by design.

Artificial hearts  must accommodate changes in demands of the body, not just in the chilled low metabolic state imposed by cardiovascular surgeons. The demands of the heart are measured by oxygen consumption in units of metabolic equivalents (METS) where 1 MET represents basal metabolism (awake at rest). MET values of activities range from 0.9 (sleeping) to 23 or more (running at 14 miles/hour = 22.5 km/hour). Thus, the artificial heart should be capable of increasing its output 2300% without damage the blood cells or running out of power. The goal of long term use generally is met by linking to an external power supply that is considered portable (on wheels), or in some cases, wearable

In contrast to Transplant of a human donor’s heart, described above, we present below the procedure for implantation of:

  • Left Ventricular Assist Device (LVAD)
  • Right Ventricular Assist Device (RVAD)
  • Bi-Ventricular Assist Device (BiVAD)
  • Total artificial heart
Heartmate II (Thoratec, Pleasanton, CA). HeartHeartmate II (Thoratec, Pleasanton, CA).  http://thenatureofhiking.com/heartless-man.html#.UiPybNKsh8E
A left ventricular assist device has two aims:
(1) reduce the work on an ailing heart and
(2) boost the forward circulation to the brain and other vital organs.
Those goals require access to the aorta and/or the left ventricle. Most LVAD devices use the apex of the left ventricle (LV) to draw blood into the pump and they deliver the blood to the aorta (for example, Heartmate II (Thoratec, Pleasanton, CA). Thus an LVAD has the following components:
(A) Input conduit,
(B) Pump,
(C) Control lines and power drive lines (may be bundled or separate),
(D) Outflow conduit and
(E) Controller and power source (may be bundled or separate, generally external).
The connections require opening the chest to gain access to the LV apex for (A) and the aorta for (E). A cannula (hollow tube conduit) is inserted through incisions in each, and secured to those two targets. The other ends of those tubes can exit the chest wall through holes created for the purpose, but a short path to the outside invites infection. Therefore longer tunnels may be created to provide a longer passage beneath the skin for body defenses against infection, or a tunnel may be created alongside the esophagus down alongside the stomach so the pump can sit in the abdomen.  Power and control for the pump (C) may require a tunnel to the surface to reach (E) (length provides greater opportunity for the skin to defend against infection), or energy transfer may be accomplished by magnetic induction (a loop of wire below the skin paired with a loop outside the patient, well aligned) and control can also be wireless.

Complications related to Open Heart Surgery

Early complications include
  • perioperative hemorrhage,
  • air embolism, and
  • ventricular failure.
Late complications include
  • infection,
  • thromboembolism, and
  • device failure.  If the power drive is connected to a power line, the patient is tethered. Alternatively, the power may be provided by a battery pack that the patient may wear or wheel alongside.

Open Heart Surgery and Reoperative Sternotomy

The e-Reader is recommended to review the Authors’ article on this topic:

Pearlman, JD and A. Lev-Ari 7/23/2013 Cardiovascular Complications: Death from Reoperative Sternotomy after prior CABG, MVR, AVR, or Radiation; Complications of PCI; Sepsis from Cardiovascular Interventions

http://pharmaceuticalintelligence.com/2013/07/23/cardiovascular-complications-of-multiple-etiologies-repeat-sternotomy-post-cabg-or-avr-post-pci-pad-endoscopy-andor-resultant-of-systemic-sepsis/

Similar to the intra-aortic balloon pump, the role of the LVAD does not require access to the left ventricle. Both goals (afterload reduction and improved forward circulation) can be accomplished in the aorta: the afterload on the left ventricle can be reduced by removing volume from the aorta during contraction of the ailing heart (systole), thereby facilitating its forward emptying. Next, both
  • perfusion of the heart and
  • promotion of circulation
can be boosted by delivering volume to the aorta during relaxation of the ailing heart (diastole).
Alternatively, there is experimentation with a continuous pump rather than mimicking the pulsation of the native heart.
A Right ventricular assist device (RVAD) draws blood from either the right atrium or the right ventricle and delivers it to the pulmonary artery. Otherwise, it has the same components and the analogous surgical requirements.
A Biventricular assist device (BiVAD) is used when neither ventricle can perform adequately. It consists of the two devices, LVAD plus RVAD, with opportunity to share components (may share the controller system, the power drive system, and even share a single pump with two circulation channels can serve as RVAD plus LVAD).

III. Implant of a Total Artificial Heart

  • A total artificial heart is similar to a BiVAD except for the option that it can replace most of the native heart instead of connecting in tandem to it
  • If a total artificial heart is placed in tandem, the procedure is basically the same as for an RVAD plus and LVAD.
  • If the total artificial heart replaces the native heart, the surgery is very similar to the heart transplant procedure explained above, plus handling for
– pump placement,
– power drive, and
– controller as for LVAD.
As a heart replacement,
  • the native right atrium connects to the right intake of the total artificial heart,
  • the main pulmonary artery connects to the right output,
  • the native left atrium connects to the left input, and
  • the aorta connects to the left output.
The so-called “heartless man”  walked more than 400 miles (six miles every day) after a SynCardia Total Artificial Heart was placed, powered by a Freedom(R) portable backpack device.

REFERENCES

  1. Shumway NE, Lower RR, Stofer RC. Transplantation of the heart. Adv Surg 1966;2:265-84.
  2. Gilles Dreyfus G, Jebara V, Mihaileanu S, Carpentier AF.  Total orthotopic heart transplantation: An alternative to the standard technique. The Annals of Thoracic Surgery Volume 52, Issue 5 , Pages 1181-1184, November 1991
  3. Angermann CE, Spes CH, Tammew A, et al. Anatomic characteristics and valvular function of the transplanted heart:
    transthoracic versus transoesophageal echocardiographic findings. J Heart Transplant 1990;9:331-8.
  4. Griepp RB, Ergin MA. The history of experimental heart transplantation. J Heart Transplant. 1984;3:145.
  5. Copeland JG, Emery RW, Levinson MM, et al. Selection of patients for cardiac transplantation. Circulation. Jan 1987;75(1):2-9. [Medline].
  6. Ramakrishna H, Jaroszewski DE, Arabia FA. Adult cardiac transplantation: A review of perioperative management Part – I. Ann Card Anaesth. Jan-Jun 2009;12(1):71-8. [Medline]
  7. Hill JD. Bridging to cardiac transplantation. Ann Thorac Surg. Jan 1989;47(1):167-71. [Medline].
  8. Portner PM, Oyer PE, Pennington DG, et al. Implantable electrical left ventricular assist system: bridge to transplantation and the future. Ann Thorac Surg. Jan 1989;47(1):142-50. [Medline].
  9. Holman WL, Kormos RL, Naftel DC, Miller MA, Pagani FD, Blume E, et al. Predictors of death and transplant in patients with a mechanical circulatory support device: a multi-institutional study. J Heart Lung Transplant. Jan 2009;28(1):44-50. [Medline].
  10. Overcast TD, Evans RW, Bowen LE, et al. Problems in the identification of potential organ donors. Misconceptions and fallacies associated with donor cards. JAMA. Mar 23-30 1984;251(12):1559-62.[Medline].
  11. Reichart B, Brandl U. 40 years of heart transplantation and the DFG-Transregio Research Group Xenotransplantation. Xenotransplantation. Sep 2008;15(5):293-294. [Medline].
  12. Moriguchi J, Davis S, Jocson R, Esmailian F, Ardehali A, Laks H, et al. Successful use of a pneumatic biventricular assist device as a bridge to transplantation in cardiogenic shock. J Heart Lung Transplant. Oct 2011;30(10):1143-7. [Medline].
  13. Kilic A, Conte JV, Shah AS, Yuh DD. Orthotopic Heart Transplantation in Patients With Metabolic Risk Factors. Ann Thorac Surg. Feb 2 2012;[Medline].
  14. Arnaoutakis GJ, George TJ, Allen JG, Russell SD, Shah AS, Conte JV, et al. Institutional volume and the effect of recipient risk on short-term mortality after orthotopic heart transplant. J Thorac Cardiovasc Surg. Jan 2012;143(1):157-67, 167.e1. [Medline].
  15. Lee I, Localio R, Brensinger CM, Blumberg EA, Lautenbach E, Gasink L, et al. Decreased post-transplant survival among heart transplant recipients with pre-transplant hepatitis C virus positivity. J Heart Lung Transplant. Nov 2011;30(11):1266-74. [Medline].
  16. Caves PK, Stinson EB, Billingham M, Shumway NE. Percutaneous transvenous endomyocardial biopsy in human heart recipients. Experience with a new technique. Ann Thorac Surg. Oct 1973;16(4):325-36.[Medline].
  17. Hunt J, Lerman M, Magee MJ, et al. Improvement of renal dysfunction by conversion from calcineurin inhibitors to sirolimus after heart transplantation. J Heart Lung Transplant. Nov 2005;24(11):1863-7.[Medline].
  18. Pedotti P, Mattucci DA, Gabbrielli F, Venettoni S, Costa AN, Taioli E. Analysis of the complex effect of donor’s age on survival of subjects who underwent heart transplantation. Transplantation. Oct 27 2005;80(8):1026-32. [Medline].
  19. Griffith BP, Hardesty RL, Deeb GM, et al. Cardiac transplantation with cyclosporin A and prednisone. Ann Surg. Sep 1982;196(3):324-9. [Medline].
  20. Ye F, Ying-Bin X, Yu-Guo W, Hetzer R. Tacrolimus versus cyclosporine microemulsion for heart transplant recipients: a meta-analysis. J Heart Lung Transplant. Jan 2009;28(1):58-66. [Medline].
  21. Khan MS, Mery CM, Zafar F, Adachi I, Heinle JS, Cabrera AG, et al. Is mechanically bridging patients with a failing cardiac graft to retransplantation an effective therapy? Analysis of the United Network of Organ Sharing database. J Heart Lung Transplant. Aug 17 2012;[Medline].
  22. Hofflin JM, Potasman I, Baldwin JC, et al. Infectious complications in heart transplant recipients receiving cyclosporine and corticosteroids. Ann Intern Med. Feb 1987;106(2):209-16. [Medline].
  23. Tambur AR, Pamboukian SV, Costanzo MR, et al. The presence of HLA-directed antibodies after heart transplantation is associated with poor allograft outcome. Transplantation. Oct 27 2005;80(8):1019-25.[Medline].
  24. Kfoury AG, Renlund DG, Snow GL, Stehlik J, Folsom JW, Fisher PW, et al. A clinical correlation study of severity of antibody-mediated rejection and cardiovascular mortality in heart transplantation. J Heart Lung Transplant. Jan 2009;28(1):51-7. [Medline].
  25. Sweeney MS, Macris MP, Frazier OH, et al. The treatment of advanced cardiac allograft rejection. Ann Thorac Surg. Oct 1988;46(4):378-81. [Medline].
  26. Ford MA, Almond CS, Gauvreau K, Piercey G, Blume ED, Smoot LB, et al. Association of graft ischemic time with survival after heart transplant among children in the United States. J Heart Lung Transplant. Nov 2011;30(11):1244-9. [Medline].

Part III

Comparative Analysis of Transplant Clinical Outcomes based on Data in: Heart Transplant (HT) Indication for Heart Failure (HF): Procedure Outcomes and Research on HF, HT @ Two Nation’s Leading HF & HT Centers

By Larry H Bernstein, MD, FCAP and Aviva Lev-Ari, PhD, RN 

 

Procedures Outcomes of Heart Transplant (HT) Indication for Heart Failure (HF)Center for Heart Failure @Cleveland Clinic, and Transplant Center @Mayo Clinic

Center for Heart Failure @Cleveland Clinic: Institution Profile

The treatment of heart failure requires a specialized multidisciplinary approach to manage the overall patient care plan.   The Kaufman Center for Heart Failure Team brings together clinicians that specialize in cardiomyopathies and ischemic heart failure for patients with:

  • All types of heart failure
  • Dilated Cardiomyopathy
  • Restrictive Cardiomyopathy
  • Arrhythmogenic Right Ventricular Dysplasia (ARVD)

Heart Failure – National Hospital Quality Measures
Cleveland Clinic, 2011 (N = 1,163) 96.9%
UHC Top Decile, 2011 99.2%
SOURCE
University Health System Consortium (UHC) Comparative Database, January through November 2011 discharges.

The Centers for Medicare and Medicaid Services (CMS) calculates two heart failure outcome measures:

  • all-cause mortality and
  • all-cause readmission rates,

each based on Medicare claims and enrollment information.

Heart Failure All-Cause 30-Day Mortality (N = 762)  July 2008 – June 2011
Cleveland Clinic 9.2%
National Average 11.6%
Heart Failure All-Cause 30-Day Readmission (N = 1,)  July 2008 – June 2011
Cleveland Clinic 27.3%
National Average 24.7%
SOURCE:
hospitalcompare.hhs.gov

The results for risk-adjusted all-cause mortality is 2% lower than the National Average and 30-day risk-adjuted readmission rates for 2008-2011 are 2% higher than the National Average.  There is no definitive information provided to explain the higher readmission rate.  One might consider that they take most difficult referrals.  The heart failure risk-adjusted readmission rate is higher than the national average; and both differences are statistically significant. To further reduce this rate, a multidisciplinary team was tasked with improving transitions from hospital to home or post-acute care facility. Specific initiatives have been implemented in each of these focus areas: communication, education and follow-up.  There is no data for comparing 1-month, 1-year, and 3-year survivals.
http://my.clevelandclinic.org/Documents/outcomes/2011/outcomes

Additional Cleveland Clinic Data is provided related to Pre- and Post-operative conditions

Preoperative patient characteristics

Prob

Diabetes mellitus 499 (21.5%) 61 (26.4%)

0.084

Congestive heart failure 758 (32.6%) 89 (38.5%)

0.069

III-IV 1830 (78.8%) 184 (84.0%)

Previous operation No injury (2324) Injury (231) P

CABG 1375 (59.2%) 162 (70.1%)

0.001

Current operation No injury (2324) Injury (231) P

CABG 897 (38.6%) 104 (45.0%)

0.056

Aortic valve surgery 1020 (43.9%) 118 (51.1%)

0.036

Tricuspid valve surgery 414 (17.8%) 52 (22.5%)

0.078

Aortic surgery 232 (10.0%) 37 (16.0%)

0.004

Postoperative results

No injury (2324) —  Injury (231) – P

PRCs 4.5  7.2 6.5  8.9

0.046

ICU stay (h) 102.3  228.6 146.3 +/- 346.9

<.001

Reoperation for bleeding 127 (5.5%) 21 (9.1%)

0.024

Sepsis 86 (3.7%) 16 (6.9%)

0.017

Stroke 56 (2.4%) 11 (4.8%)

0.033

Prolonged ventilation 505 (21.7%) 97 (42.0%)

<.001

Pneumonia 123 (5.3%) 25 (10.8%)

<.001

ARDS 32 (1.4%) 8 (3.5%)

0.015

Postoperative renal failure 237 (10.2%) 51 (22.1%)

<.001

Multisystem failure 45 (1.9%) 13 (5.6%)

<.001

Hospital death 151 (6.5%) 43 (18.6%)

<.001

Cleveland Clinic
LVAD mortality 2007-2011   5%
VAD mortality   2011
Obs 10%  Exp   17.5%  N 56
HF- NHQM
2010    1194    93.9%
2011    1163    96.9%
UHC Top decile, 2011   99.2%

Transplant Center @ Mayo Clinic: Alternative Solutions to Treatment of Heart Failure.  Mayo Clinic performs has pre-eminent adult and pediatric transplant programs.

Success Measures   2009-2011

1 mo

1 year

3 year

Heart Transplant Patient Survival — Adult
Mayo – Phoenix, AZ (n=40)

97.50%

94.63%

82.22%

Mayo – Jacksonville, FL (n=61)

95.08%

91.50%

81.82%

Saint Marys Hospital – Rochester, MN (n=48)

95.83%

95.83%

82.61%

National Average

95.89%

90.21%

81.79%

Heart Transplant – Children
Saint Marys Hospital – Rochester, MN (n=5)

100%

100%

60%

Adult Heart Organ (Graft)
Mayo – Phoenix, AZ (n=41)

97.56%

94.77%

82.22%

Mayo – Jacksonville, FL (n=61)

95.08%

91.50%

80.00%

Mayo -Rochester, MN (n=49)

93.88%

93.88%

82.61%

National Average

95.71%

89.91%

80.92%

Standards for Comparison:  SRTR function, data acquisition, analysis, and reporting.

Curator: Larry H Bernstein, MD and Curator: Aviva Lev-Ari, PhD, RN
Source: Program Specific Reprting, by S Everson [SRTR]

http://srtr.transplant.hrsa.gov/

The Scientific Registry of Transplant Recipients

supports the ongoing evaluation of solid organ transplantation in the United States. SRTR designs and carries out data analyses and maintains two websites to disseminate organ transplant information.

This site is srtr.transplant.hrsa.gov. Here you will find the OPTN/SRTR Annual Data Report, which publishes organ transplant statistics and is produced each year by SRTR staff and staff of the national Organ Procurement and Transplantation Network (OPTN).

At www.srtr.org, you will find older (pre-2010) annual data reports, current and past reports on organ procurement organizations and transplant programs, and information for researchers (including additional data tables and information about SRTR data and statistical methods).

Both sites aim to inform transplant programs, organ procurement organizations, policy makers, transplant professionals, transplant recipients, organ donors and donor families, and the general public about the current state of solid organ transplantation in the US.

SRTR also helps facilitate transplant research by providing access to data for qualified researchers interested in studying various aspects of solid organ transplantation.

The SRTR supports ongoing evaluation of the scientific and clinical status of solid organ transplantation and it provides data on all solid organ transplants and donations in the United States with oversight and funding from the Health Resources and Services Administration (HRSA), a division of the US Department of Health and Human Services, and is admionitered by the Chronic Disease Research Group of the Minneapolis Medical Research Foundation.
How SRTR differs from the Organ Procurement and Transplantation Network (OPTN).
Program-Specific Reports and their intended audience.
  1. Timeline and cohort selection.
  2. Patients who are lost to follow-up: censoring and extra ascertainment.
  3. Expected survival and risk-adjustment.
  4. Comparison points: norms versus targets.
Interpretation of survival statistics: what is important to whom? 
SRTR Products and Responsibilities: Inferential Analyses to Support Policymaking and Patient Care
*Analytic support for policy committees (OPTN, Advisory Committee on Organ Transplantation [ACOT]).
*OPTN/SRTR Annual Report.
Publications
*Report to Congress.
Journal articles and scientific presentations.
Public release data files for researchers.
*Program-specific analyses (Program-Specific Reports, Organ Procurement Organization [OPO] reports, etc).
Inferential requests.
Primary data from OPTN, supplemented with other sources.
*legislatively mandated
^Primary data source is the transplant center, submitting data through the OPTN system. Includes WL and organ allocation, tiedi, match runs.
  1. Range of other data here are incorporated either on a person-level matching basis or on an aggregate basis for comparison.
  2. Primary data source is the transplant center, submitting data through the OPTN system. Includes WL and organ allocation, tiedi, match runs.
  3. Range of other data here are incorporated either on a person-level matching basis or on an aggregate basis for comparison.
  4. Primary data source is the transplant center, submitting data through the OPTN system. Includes WL and organ allocation, tiedi, match runs.
  5. Range of other data here are incorporated either on a person-level matching basis or on an aggregate basis for comparison.
  6. National Death Index is not be used for analyses, but is used to evaluate completeness of extra ascertainment.
Each month, the SRTR receives an updated version of all data submitted by transplant centers, organ procurement organizations, and histocompatibility laboratories, along with data produced by the OPTN itself regarding organ offers, match runs, and the like.  Data linkages are used to add patient-level data, and additional ascertainment of mortality events is provided via linkage to the Social Security Death Master File.   Analysis files optimized for research are created and merged with analysis variables from the National Center for Health Statistics and the annual survey of the American Hospital Association to produce a set of Standard Analysis Files.  These are the data files used for SRTR analyses.
Regularly scheduled analyses are produced, including those available to the public such as the center-specific reports of transplant programs and OPOs, reports to the OPTN Membership and Professional Standards Committee, and the standardized insurance request for information data reports.  Program-Specific Reporting (http://www.srtr.org) uses different formats for different audiences. Feedback from centers enables data fixes and data quality improvements to occur over time.
Additional research is presented in the form of journal articles, the SRTR Report on the State of Transplantation published each year in the American Journal of Transplantation, conference proceedings, reports to OPTN and ACOT committees, an Annual Report published on the web and on CD, and a Biennial Report to Congress.  The same Standard Analysis Files that are used by SRTR are available to all researchers and can be obtained via submission of an analysis plan and completion of a Data Use Agreement.
Using SRTR-calculated center-specific statistics provides several advantages – for each audience of the CSR — over having each center self-report these characteristics:
  • Uniform methodology: The SRTR provides a uniform methodology of calculation. These methods are standard and accepted within the statistical and medical communities, however they are not the only ones available.
  • Audited data collection: All data on which these statistics are based are audited by the OPTN. The United Network for Organ Sharing (UNOS), the contractor for the OPTN, works to ensure the accuracy and reliability of these data.
  • Extra ascertainment of mortality: The SRTR helps find information about patients who become lost-to-follow-up that may be unavailable to transplanting centers, or very difficult to find.
  • Risk adjustment: Comparison of outcomes should be based on risk-adjusted models that account for the types of patients treated. Without national data, it is impossible for centers to calculate risk-adjusted comparison points.

Program-Specific Reporting –  different formats for different audiences: What we choose to focus on 

 

 Percent survival at one year, three years.

  1. What choices do our patients have?
  2. How well are we doing?

*Report Contents – Focus on patient outcomes

 Report Tables [10-11]– 
  1. Graft and patient survival rates compared with expected values
  2. Updated every 6 months (January, July).
  3. Patient and graft survival tables report 1-month, 1-year, and 3-year outcomes for 2.5-year cohorts of recipients.

Calculating Survival

 

Transplant Month Follow-up Group A: Transplant > 1 Y Group B:Transplant 6-12 Mo All
Months 0-6 Transplants
Deaths
100
10
100
14
200
24
Survival 90% 86% 88%
Months 7-12 At-Risk
Deaths
Survival
90
18
80%
Not yet observed,
Use 80%
.88*.80 = 70.4%or  (72 + 68.8)/2 = 70.4
1 Year Survival .90 * .80 = 72% .86*.80 = 68.8%

Incomplete Data and Loss to Follow-Up

  • Censoring (Kaplan Meier/Cox) works only if “lost” patients have similar failure rates as followed patients (unbiased).
  • Censoring can produce unstable estimates for small samples
  • NDI study indicates that the SRTR identifies > 99% of deaths
  • Observed rates are compared with rates that would be expected based on characteristics of recipients and donors at each center.
  • Allows fair comparison among centers that treat different types of patients
  • Is the difference we see between the observed survival of 87.78% and the expected rate of 89.41% large enough to be meaningful? The answer may depend perspective.

The percent surviving at one year is only 2% lower than expected, an apparently small difference. However, the same difference appears more consequential when comparing the percent died that implied by subtracting survival percents from 100: the percent of patients who had died by the end of the first year was a full 15% higher than expected. Finally, in our example center that performed 90 transplants during a 2.5-year period, the count of deaths observed during follow-up was 30% higher, accounting for 2.5 deaths more than we would expect during time these patients were followed.

The difference between each of these is stark. The first change from a 2% difference to a 15% difference reflects the change in denominator: a small percentage point difference is a much smaller fraction of survival (usually a large number at one year) than of mortality (usually a small number). Several years after transplant, when survival rates may be close to 50%, the contrast would not be as evident.

The difference between the percent died and death count is more subtle: the expected number of deaths is calculated according to the time that patients are followed after transplant, so a patient whose follow-up ends immediately after transplant – for any reason, including death — is smaller than the expected number of deaths for a patient who died after ten months. Therefore, this last statistic accounts for the difference between a patient who survives only briefly during follow-up, and one who survives nearly the entire period, despite the fact that they have both died in the end-of-period accounting of “percent died”.

Survival time -expected deaths

Risk Adjustment

What rate would be expected for patients at this center if their outcomes were comparable to national outcomes for similar patients?
“Similar” defined by characteristics that affect the rate, such as:

  • Demographics
  • Etiology
  • Severity of illness

Differences between observed and expected outcomes are not due to these adjustment factors.

*notion of a “similar” patient: have in-common characteristics that may influence the outcome –
include basic demographic factors such as age, etiology of disease, and the patient’s severity of illness.

journal.pmed.0020133.g001 Global Mortality and Burden of Disease Attributable to Cardiovascular Diseases and Their Major Risk Factors for People 30 y of Age and Older

278px-Preventable_causes_of_death
Causes_of_death_by_age_group

Adjusted odds ratios comparing the results of CABG and PCI-stenting in the various prespecified subsets.

50-Graph-4-33_2012 Hospitalization Rates for Heart Failure, Ages 45–64 and 65 and Older, U.S., 1971–2010

48-Graph-4-30_2012 Age-Adjusted Prevalence of Cardiovascular Disease Risk Factors in Adults, U.S., 1961–2011

Risk-Adjustment Models

Each risk-adjustment model is published one month in advance of the PSRs (Figure 5). These tables serve not only as a list of all characteristics incorporated, but also tell the reader:

  1. The beta, or calculated coefficient, tells what was the effect of that characteristic on expected risk of dying or failed transplant?
  2. The standard error and p-value tell how much random variance there was around this estimate, and how sure we are that there is a real effect of this characteristic.
  3. Models are repeated for a series of three different cohorts of transplants, allowing a comparison of how stable the coefficients are across time.
  4. The index of concordance, for each model, tells the percent of variation in the order of events (deaths or graft failures) that is accurately predicted by the model. A index of 100% would suggest that the model perfectly predicts the order of events; 50% would suggest that the order is random with regard to predictors.

*Odds Ratio >1 = Failure/Death More Likely = Lower Expected;
Odds Ratio <1 = Failure/Death Less Likely = Higher Expected

Adjusting for Age

Nationally: Average survival, 85%.

  • 50% of patients are young with 95% survival.
  • 50% of patients are old with 75% survival.

Center A treats only older patients, 80% survival:
Center survival of 80% worse than national average of 85%.
100% are older patients with expected 75% survival.
Center A patients have better expected survival compared with similar patients nationwide
Center X Treats More Older Recipients than the National Average

more older recipients

Adjustment: Account for Case Mix

The older recipient age at Center X (along with other factors) gives Center X an expected 13.1% deaths, compared with the national average of 9.5%.
Use ratio of observed/expected deaths.

Adjustment: Random Variation

Obs/Exp Deaths: Center X = 1.1 (0.88-1.37); National Ave = 1.0
The confidence interval for Center X, reflecting random variation in this measure over time, overlaps the national average.
Do not flag Center X.

Concepts: Actionable, Important, and Significant

The first principle in these criteria is that all comparisons should be based on observed and expected events during the time a patient is actually followed either by the center or, in the case of patient survival, by extra ascertainment; no imputed survival should be used. They should also account for the difference in outcomes between a patient who dies in the 1st week after transplant versus 51st week.
The following criteria, applied by the MPSC, are based on comparison of counts of observed and expected deaths (graft failures) as presented in “Deaths during follow-up period”. To be identified for further review by the MPSC, differences between observed and expected must meet all of the following criteria:
Actionable: the magnitude of the problem, in terms of potential lives saved, should be sufficient to take action
  1. MPSC Criteria: Observed (O) – Expected (E) greater than 3, O – E > 3
  2. Interpretation: 3 excess deaths per 2-year transplant cohort
Important: a clinically significant pattern, suggesting that it may be changeable, indicated by a high fraction of excess deaths
  1. MPSC Criteria: Standardized Mortality Ratio (SMR) > 1.5; O / E > 1.5
  2. Interpretation: 50% more deaths than expected
Significant: it should be unlikely that the difference occurred by random chance alone
  1. MPSC Criteria: one-sided p-value less than .05
  2. Interpretation: there is less than a 5 percent chance that a poor outcome occurred by simple random variation

Important: More than 3 excess deaths

more than 3 excess deaths

Actionable: More than 50% excess deaths

more than s 50% excess deaths

excess deaths unlikely due to hance

MPSC Flagging Boundaries

1-s2.0-S0194599809003301-gr1 action statement may be classified as an option, recommendation, or strong recommendation

Part IV

Imaging Technologies in use for Clinical Monitoring of Patients with Heart Transplant: Donor Human Heart and Artificial Heart

By Justin D Pearlman, MD, PhD, FACC

Imaging of the heart monitors success and viability of the transplanted heart in terms of

what fraction of the contents of each ventricle moves out of the heart (ejection fraction),

  • what volumes the heart sees
  1. end-diastolic volume, or EDV, and
  2. end-diastolic diameter, or
  3. LVIDd,
  4. end systolic volume or ESV),
  5. how well the walls move (wall motion) and
  6. wall thickening analysis,
  • tissue character
  1. visual evidence for changes in the heart muscle,
  2. perfusion (delivery of nutrient blood supply to the heart muscle), and
  3. various means to detect coronary artery disease (obstructions to blood delivery to the heart muscle).

Clinical tools for imaging the heart include:

  1. The major tool – ultrasound (echocardiography),
  2. cardiac magnetic resonance (CMR),
  3. computed xray tomography (CT),
  4. catheterization with xray imaging (coronary angiography and ventriculography),
  5. metabolic marker distribution by positron emission tomography (PET), and
  6. radioactive marker distribution (nuclear imaging, SPECT).

Ultrasound applies alternating current to a piezoelectric crystal (lead zirconate) to produce compressions and expansions of material as a wave pattern that relies on tissue elastic properties to propagate into the tissue, reflecting back when the wave encounters a change of properties (acoustic impedance mismatch). Display of signal versus time on an oscilloscope (like an ECG monitor) constitutes “A-mode”(amplitude) display, whereby the distance between peaks corresponds to distances along the path that can report thickness of the left ventricle, and diameter of the left ventricular cavity. Time translates to distance because the speed of sound through tissue is fairely constant, ~1540 meters/second. Collapsing the peaks to bright dots represents the same data in “B-mode” (brightness) which reduces the data to a line of variable intensity with bright dots marking changes in tissue (e.g., muscle versus blood). Attaching a position sensor to the handle of the sound source (the transducer) enabled plotting the B-mode signal on a 2D screen to indicate the position of the sound beam. Gynecologists showed that a steady sweep of the transducer (C-mode, composite) then generated 2D images that delineated the shape of a fetal head, and as quality improved, the gender prior to birth. The invention of phased-array crystal sets (multiple sources electrically activated sequentially with specific timing) enabled generation of a composite beam that is electronically swept in an arc with no mechanically moving parts. That is now the main method of ultrasound imaging, called phased-array sector scanning. More advanced phased arrays sweep in a 2D pattern to generate 3D imaging (4D or dynamic 3D, when you include repeating over time).

The e-Reader is encourage to review Cardiovascular Imaging Chapters in each of the three volumes.

For new technological developments in achieving Optimal PCI Outcomes and for Visual Tools for Characterization of endovascular tissue affecting Coronary Circulation, review the following article:

Coronary Circulation Combined Assessment: Optical Coherence Tomography (OCT), Near-Infrared Spectroscopy (NIRS) and Intravascular Ultrasound (IVUS) – Detection of Lipid-Rich Plaque and Prevention of ACS

Part V

The Failure of a Heart Transplant – Pathology and Autopsy Findings

by Larry H Bernstein, MD, FCAP 

Section A.  SRTR Graft and Patient Survival Data

Table 1.  Transplant Survivals, 2011, and related conditions

Activities    2011 Numbers
Deceased donor transplants (n=number) 2,322
Adult graft survival (based on 4595  transplants) 89.91 (%)
Adult patient survival (based on 4449 transplants) 90.21 (%)
Pediatric graft survival (based on 886  transplants) 90.74 (%)
Pediatric patient survival (based on 829  transplants) 91.31 (%)
Primary Disease (%) of Waitlist
Cardiomyopathy 49.4
Coronary Artery Disease 34.7
Retransplant/Graft Failure   4.4
Valvular Heart Disease   1.7
Congenital Heart Disease   8.4

Table 2.  Recipient Condition at Transplant (%)

Not Hospitalized 54.0
Hospitalized 14.6
ICU 31.0
No Support Mechanism 25.2
Devices 42.4
Other Support Mechanism 32.2

Table 3.  Donor Characteristics

Cause of Death (%)
Stroke 20.9
MVA 23.4
Other 55.7
Age (years)
18-34 48.8
35-49 24.5
12-17 9.4
Cold ischemic time 1.5-4.5 h 85.3

Table 4.  Graft and Patient Survival

Survival by… time since transplant
1 mo 1 yr 3 yrs
Adult (Age 18+)
Graft survival (%)   95.7   89.9   80.9
# failures

197

442

847

Patient survival (%)   95.9   90.2   81.8
# deaths

183

415

783

Pediatric (Age < 18)
Graft Survival (%)   96.3   90.7   82.0
Graft Failures

  33

  80

151

Patient Survival (%)

  96.4

  91.3

 82.93

Deaths

  30

  70 134

* 07/01/2006 and 12/31/2008 for the 3 Year Model

Table 4.    Risk Model Documentation – Adult, Three−Year Graft Survival

Characteristic Level Estimate Std. Err. P−Value
Bilirubin at Transplant mg/dL 0.0364 0.008 <0.0001
Dialysis at Transplant Yes 0.8026 0.169 <0.0001
Donor Age 0−17 −0.5789 0.140 <0.0001
18−34 −0.3098 0.074 <0.0001
Ischemic Time hrs 0.1298 0.033 <0.0001
Previous Transplant Yes 0.4251 0.157 0.0069
Recipient DX Cardiomyopathy −0.1933 0.078 0.0130
Recipient Age 18-34 0.2806 0.110 0.0107
65+ 0.2694 0.101 0.0074
Recipient Race Black 0.4104 0.086 <0.0001
Recipient SCrea >1 & <=1.5 mg/dL 0.0115 0.086 0.8933
>1.5 mg/dL 0.4316 0.095 <0.0001
Recipient on VAD Yes 0.2777 0.086 0.0013
Recipient on Vent Yes 0.7014 0.169 <0.0001

* SRTR Program−Specific Report   July 12, 2012

Table 5.  Risk Model Documentation  Adult, Three−Year Patient Survival

Characteristic Level Estimate Std. Err. P−Value
Donor Age 0−17 −0.4758 0.1452 0.0010
18−34 −0.3066 0.0764 0.0001
Ischemic Time hrs 0.1400 0.0344 <0.0001
Most Recent CPRA/PRA% 0.0039 0.0019 0.0359
Recipient Age 18−34 0.3041 0.1157 0.0086
65+ 0.3089 0.1013 0.0023
Recipient DX Cardiomyopathy −0.2151 0.0809 0.0078
Congen Heart Dis 0.5504 0.2085 0.0083
Recipient Race Black 0.4942 0.0895 <0.0001
Recipient SCrea >1 and <=1.5 0.0245 0.0887 0.7827
>1.5 mg/dL 0.5053 0.0991 <0.0001
Recipient on VAD Yes 0.2559 0.0816 0.0017
Recipient on Vent Yes 0.7340 0.1852 0.0001

Note the following: 

1. The most common transplant recipients in adults are cardiomyopathy and CAD, and congenital heart disease in children.
2.  recipient on VAD or on vantilator is significant
3.  ischemic time for donor heart is usually 1.5-4.5 hours, but longer time has an effect on graft and patient survival
4. Recipient serum creatinine exceeding 1.5 mg/dl is unfavorable, but considering BMI and age related renal nephron loss, eGFR would be a better measure.5.  African-American has an effect, but it is not at all clear whether sickle cell trait or disease is a factor.
6. Half the recipients are not hospitalized, and they might coincide with no or other support.

Section B.  Special Concerns

Topic 1

Cellular repopulation of myocardial infarction in patients with sex-mismatched heart transplantation
Source: Georg-August-University G€ottingen.  c2004, Eur Soc Cardiol

Recent studies have suggested that human extracardiac progenitor cells are capable of differentiating into cardiomyocytes. In animal studies, myocardial infarction attracted bone marrow stem cells and enhanced their differentiation into cardiomyocytes.
Myocardial infarction enhances the invasion of extracardiac progenitor cells and their  regeneration of endothelial cells. However, a significant differentiation into cardiomyocytes as a physiological mechanism of postischaemic regeneration does not occur in transplanted patients.

Topic 2

Five-year follow-up of hepatitis C-naïve heart transplant recipients who received hepatitis C-positive donor hearts.
G S Gudmundsson, K Malinowska, J A Robinson, B A Pisani, J C Mendez, B K Foy, G M Mullen
Advanced Heart Failure/Heart Transplant Program, Loyola University, Maywood, Illinois, USA.
Transplantation Proceedings (impact factor: 1). 07/2003; 35(4):1536-8.
Source: PubMed

Due to the risk of transmission of hepatitis C virus, the use of hepatitis C seropositive donors in heart transplantation is controversial. The transmission rate of hepatitis C in this patient population is estimated to range from 67% to 80%. Long-term clinical outcomes of heart transplant recipients of hepatitis C-positive donor hearts are not well described. We report the 5-year long-term outcome of seven hepatitis C-naïve heart transplant recipients who received hepatitis C-positive donor hearts.

Seven hearts transplant recipients, six men and one woman were included in our study. After a mean follow-up of 63.3 +/- 20.4 months (range 28.2 to 85.9), four of seven (57.1%) patients are hepatitis C-negative, have normal liver function tests, and no clinical evidence of hepatitis. Three of seven (43%) have been diagnosed with hepatitis C by liver biopsy or the HCV-RNA reverse transcriptase polymerase chain reaction at a mean follow-up of 35.1 months (18.8 months posttransplantation). One had an accelerated course of hepatitis that was ultimately fatal, one was successfully treated with interferon, and the third died from other causes than liver injury. Overall, the 5-year survival was 71.4%.

Topic 3

Cryptococcus neoformans Infection in Organ Transplant Recipients: Variables Influencing Clinical Characteristics and Outcome
Shahid Husain, Marilyn M. Wagener, and Nina Singh
Veterans Affairs Medical Center and University of Pittsburgh
Thomas E. Starzl Transplantation Institute, Pittsburgh, Pennsylvania, USA
Emerging Infectious Diseases 376 Vol. 7, No. 3, May–June 2001

Unique clinical characteristics and other variables influencing the outcome of Cryptococcus neoformans infection in organ transplant recipients have not been well defined. From a review of published reports, we found that C. neoformans infection was documented in 2.8% of organ transplant recipients (overall death rate 42%). The type of primary immunosuppressive agent used in transplantation influenced the predominant clinical manifestation of cryptococcosis. Patients receiving tacrolimus were significantly less likely to have central nervous system involvement (78% versus 11%, p =0.001) and more likely to have skin, soft-tissue, and osteoarticular involvement (66% versus 21%, p = 0.006) than patients receiving nontacrolimus-based immunosuppression. Renal failure at admission was the only independently significant predictor of death in these patients (odds ratio 16.4, 95% CI 1.9–143, p = 0.004). Hypotheses based on these data may elucidate the pathogenesis and may ultimately guide the management of C. neoformans infection in organ transplant recipients.

Patients were 12 to 67 years of age (median 44 years); 78% were male. The mean incidence of C. neoformans infection was 2.8 per 100 transplants (0.3 to 5.3 per 100). The overall incidence was 2.4% in liver, 2.0% in lung, 3.0% in heart, and 2.8% in renal transplant recipients. Of 127 transplant recipients who could be evaluated, 100 (79%) had azathioprine as the primary immunosuppressive agent, 9 (7%) had tacrolimus, 11 (9%) had cyclosporine, and 7 (6%) had cyclosporine and azathioprine. Of these 127 patients, 78 were also receiving prednisone in various dosages. The incidence of cryptococcosis was 4.5 per 100 transplants in patients who received tacrolimus, 2.4 per 100 transplants in patients who received cyclosporine, and 3.4 per 100 transplants in patients who received azathioprine. These rates did not differ significantly. Rejection episodes preceding cryptococcal infection were documented in 17 (25%) of 67 patients; rejection had occurred a median of 7 months (from 5 days to 49 months) before onset of infection.

Cryptococcosis occurred a median of 1.6 years (from 2 days to 12 years) after transplantation. Overall, 14 (15%) of 94 cases occurred within 3 months, 10 (11%) of 94 in 3 to 6 months, 15 (16%) of 94 in 6 to 12 months, and 55 (59%) of 94 >12 months after transplantation.  The median time to onset after transplantation was 35 months for kidney, 25 months for heart, 8.8 months for liver, and 3 months for lung transplant recipients (p = 0.001). Overall, cryptococcosis developed in 100% of the lung, 75% of the liver, 33% of the heart, and 30% of the kidney transplant recipients within 12 months of transplantation (p = 0.002).

Topic 4

Diagnostic Accuracy of Mortality on a Population of Heart Transplant Patients
M AMUCHÁSTEGUI, AE CONTRERAS, O SALOMONE, A DILLER, et al.
Hospital Privado Centro Médico de Córdoba
REV ARGENT CARDIOL 2008;76:292-294.

Although morbidity and mortality rates in heart transplant have been extensively analyzed, most mortality studies and mortality registries in heart transplant patients are based on clinical data.
Between January 1990 and January 2005 all dead transplant patients were included. The final diagnosis of the cause of death was confirmed with necropsy or biopsy of a solid organ. The causes of death assessed were early graft failure, cellular rejection, graft vascular disease, neoplasms and others.
Seventy three patients underwent heart transplantation during the study period. Thirty one patients died. The cause of death was certified in 61% of cases by 12 necropsies and 7 solid organ biopsies.

  • Cellular rejection greater than grade III was the most frequent cause of death.
  • Histopathology studies differed from the clinically suspected cause of death in 12.9% of cases.

Clinical and pathological information derived from post mortem studies is an indicator of the reality of our practice and constitutes an underlying mainstay for understanding transplant patients and for their further management; in this sense, performing necropsies is of vital importance for these patients.

Topic 5

How do Heart Failure patients die?
S. Orn and K. Dickstein
Central Hospital in Rogaland, Stavanger, Norway
European Heart Journal Supplements (2002) 4 (Supplement D), D59-D65
http://eurheartjsupp.oxfordjournals.org/

Approximately 90% of heart failure patients die from cardiovascular causes. Fifty per cent die from progressive heart failure, and the remainder die suddenly from arrhythmias and ischaemic events. Autopsy reveals the presence of an acute ischaemic event inapproximately 50% of sudden deaths and in 35% of all deaths among patients with ischaemic heart failure.

An accurate description of the cause and mode of death is important if we are to elucidate the mechanisms that are operative in the heart failure population.

At present, the most accurate data on mode of death are obtained from large randomized heart failure trials. They indicate that current treatment strategies for heart failure prolong life expectancy, but have relatively little impact on the proportion of heart failure patients who die from cardiovascular causes. The ultimate goal of intervention is to shift the balance toward more deaths from non-cardiovascular causes. (Eur Heart J Supplements 2002; 4 (Suppl D): D59-D65)
The heterogeneity of the heart failure population is reflected in the different ways in which these patients die.

  • Some deteriorate progressively, whereas others
  • die after acute episodes of decompensation.
  • Others die suddenly and unexpectedly, and some (relatively few)
  • die from noncardiac causes.

Before the angiotensin-converting enzyme (ACE) inhibitor era, it was estimated that

  • 90% of the total deaths in heart failure patients were from cardiovascular causes,
  • 49% were related to worsening heart failure,
  • 22% to arrhythmias and
  • 11% to acute myocardial infarction[S].

It is conventional to categorise death according to mode and cause of death.

  • Cause of death addresses the mechanisms by which death occurs, such as arrhythmia, acute myocardial infarction or progressive heart failure (Table 1).
  • Mode of death is perhaps easier to categorise.
  • Mode and cause of death are not the same, although they are often used interchangeably.

Sudden death has various underlying causes, such as

  • arrhythmia,
  • acute myocardial infarction,
  • pulmonary embolism,
  • myocardial or aortic rupture, and
  • stroke.

Sudden cardiac death is defined as natural death due to cardiac causes, heralded by abrupt loss of consciousness within 1 h of the onset of acute symptoms[2].

In order to avoid confusion in terminology, some clinical trials subclassify death without using the term ’cause of death’ and end-point committees focus instead on mode and place of death (Table 1)[31]. However, although it is more difficult to classify cause of death than mode of death, it is nevertheless productive to examine the causes of death among heart failure patients. The cause of death reflects the underlying pathophysiology of the disease, and helps us to understand the mechanisms responsible for its progression. Unravelling the mechanisms that lead to death is clinically relevant and may reveal potential new treatment targets. Effective treatment may alter the cause of death, and should ideally shift the operative mechanism from cardiovascular to noncardiovascular. Most of our knowledge of the cause and mode of death in heart failure comes from the

  • large randomized mortality trials and from
  • official death registries.

However, both of these sources of information have their problems.

A simplified classification of heart failure deaths

  • Cardiovascular
  • Non-cardiovascular
  • Cardiac
  • Myocardial infarction
  • Progressive heart failure
  • Other cardiac
  • Sudden death
  • Non-cardiac
  • Stroke
  • Other
  • Procedure-related

Conclusions

by Larry H Bernstein, MD, FCAP 

Part I

Leading Causes of Death

Number of Deaths – Leading Causes

Heart disease

597,689

Cancer

574,743

Chronic Lung Disease

138,080

Stroke

129,476

Accidents

120,859

Alzheimer’s

83,494

Diabetes

69,071

Kidney disease

50,476

Influenza and Pneumonia

50,097

Suicide

38,364

*National Vital Statistics Report (NVSR) “Deaths: Final Data for 2010.”   MortalityData@cdc.gov.

WHO Leading Causes of Death

Low income countries

Deaths (mil)

% of deaths

Lower respiratory infections

1.05

11.3

Diarrheal diseases

0.76

8.2

HIV/AIDS

0.72

7.8

Ischemic heart disease

0.57

6.1

Malaria

0.48

5.2

High-income countries

Deaths (mil)

% of deaths

Ischemic heart disease

1.42

15.6

Cerebrovascular disease

0.79

8.7

Bronchioepithelial cancers

0.54

5.9

Alzheimer and dementias

0.37

4.1

Pneumonias

0.35

3.8

High-income countries

Deaths (mil)

% of deaths

Ischemic heart disease

5.27

13.7

Stroke

4.91

12.8

COPD

2.79

7.2

Lower respiratory infections

2.07

5.4

Diarrheal diseases

1.68

4.4

World

Deaths (mil)

% of deaths

Ischaemic heart disease

7.25

12.8

Stroke

6.15

10.8

Pneumonias

3.46

6.1

COPD

3.28

5.8

Diarrheal diseases

2.46

4.3

HIV/AIDS

1.78

3.1

Q: What is the number one cause of death throughout the world?
Cardiovascular diseases kill more people each year than any others. In 2008, 7.3 million people died of ischaemic heart disease, 6.2 million from stroke or another form of cerebrovascular disease.

Q: Isn’t smoking a top cause of death?
Tobacco use is a major cause of many of the world’s top killer diseases – including cardiovascular disease, chronic obstructive lung disease and lung cancer.

Deaths across the globe: an overview

Imagine a diverse international group of 1000 individuals representative of the women, men and children from all over the globe who died in 2008. Of those 1000 people,

  • 159 would have come from high-income countries,
  • 677 from middle-income countries and
  • 163 from low-income countries.

What would be the top 10 causes of their deaths?
Low income countries
http://who.int/entity/mediacentre/factsheets/fs310_graph3.gif
Middle income countries
http://who.int/entity/mediacentre/factsheets/fs310_graph3.gif
High income countries
http://who.int/entity/mediacentre/factsheets/fs310_graph3.gif

Note: In this fact sheet, we use low-, middle- and high-income categories as defined by the World Bank. Countries are grouped based on their 2009 gross national income. See World health statistics 2011 for more information.

SOURCE

World health statistics 2011

Part II

Advances in Imaging Technology

This document discusses the advances in cardiac surgery assisted by rapid advances in cardiac imaging technology over the last 15 years.  This portion concentrates on the treatments for advanced and disabling congestive heart failure as the age expectancy has increased to a range of early 8th and mid-9th decade, depending on patient related comorbidities, nutrition and activity status.  Many of the patients who require a heart transplant have coincident metabolic syndrome, advanced coronary artery circulation compromise, and/or atherosclerotic disease at the aortic arch.  The advances in cardiothoracic technique has enabled a parallel advance in ventricular assist devices and a total artificial heart, which has allowed the maintenance of patients on waitlists until a suitable donor can be found, which is usually under a 5 year period.  The ventricular assist device is selected for those patients who have sufficient reserve of left ventricular function. The cardiac and cardiosurgical advances have been advanced by the development of vastly improved imaging for both diagnosis and for enabling safety of procedures.

Cardiac magnetic resonance imaging is a noninvasive technique for assessing heart structure and function without the need for ionizing radiation. Its ability to precisely outline regions of myocardial ischemia and infarction gives it an important role in guiding interventional cardiologists in revascularization. Its ability to characterize and precisely quantify abnormal regurgitant flow volumes or abnormal shunts also makes it a valuable tool for many noncoronary interventions. The evidence is sufficient to show that cardiac magnetic resonance in guiding complex therapies in the catheter laboratory, as well as practical issues that need to be addressed to allow the application of this powerful tool to an increasing number of patients.  But this advantage extends as well to the transplantation arena.1 (Cardiac magnetic resonance imaging for the interventional cardiologist. GA Figtree, JLønborg, SM Grieve, MR Ward, RBhindi. University of Sydney, Sydney, Australia.  PubMed 02/2011; 4(2):137-48.  http://dx.doi.org/10.1016/j.jcin.2010.09.026.)

Further, A novel approach to three-dimensional (3D) visualization of high quality, respiratory compensated cardiac magnetic resonance (MR) data is presented with the purpose of assisting the cardiovascular surgeon and the invasive cardiologist in the pre-operative planning2. Developments included:

(1) optimization of 3D, MR scan protocols;
(2) dedicated segmentation software;
(3) optimization of model generation algorithms;
(4) interactive, virtual reality visualization.

The approach is based on a tool for interactive, real-time visualization of 3D cardiac MR datasets in the form of 3D heart models displayed on virtual reality equipment. This allows the cardiac surgeon and the cardiologist to examine the model as if they were actually holding it in their hands. To secure relevant examination of all details related to cardiac morphology, the model can be re-scaled and the viewpoint can be set to any point inside the heart. Finally, the original, raw MR images can be examined on line as textures in cut-planes through the heart models3. (A new virtual reality approach for planning of cardiac interventions. T S Sørensen, SV Therkildsen, P Makowski, JL Knudsen, EM Pedersen. University of Aarhus Abogade 34, 8200 N, Arhus, Denmark. PubMed 07/2001; 22(3):193-214.

In addition, TeraRecon, (www.terarecon.com), the largest dedicated provider of advanced visualization and decision support solutions for medical imaging, showcased iNtuitionREVIEW™, a powerful new multi-modality, multi-monitor review and collaboration tool at the 24th European Congress Of Radiology4, held at the Austria Center, Vienna, Austria, March 8th-11th 2013. iNtuitionREVIEW is part of the iNtuition™ solution suite for advanced image management and quantitative decision support.

iNtuition has always complemented PACS with advanced functionality to resolve specialized use cases and workflow challenges not adequately addressed by existing PACS solutions.  Features relevant to this discussion are:

  • Time-Volume Analysis – Enhanced support for Cardiac MRI image acquisitions
  • 3D/4D Visualization – Enhanced TAVI (transcatheter valve implantation) analysis
  • Lesion-Specific Analysis – Support for research into downstream impact of stenosis

Editorial5: Seeing the heart; the success story of cardiac imaging
European Heart Journal 2000; 21(16): 1281–1288
http://dx.doi.org/10.1053/euhj.2000.2299

In 1896 a large audience at the Wurzburg Physical Medical Society attended a lecture and a demonstration, published a paper in 1895 ‘Eine Neue Art von Strahlen’ in the Annals of the Society. He showed an image of the hand of the famous anatomist F. Von Kolliker (1817– 1905). He was awarded the first Nobel prize laureate in Physics in 1901.  FH Williams (1852–1936) began lecturing on the use of X-rays in visualization of the heart. In his paper ‘A method for more fully determining the outline of the heart by means of a fluoroscope together with otheruses of this instrument in medicine, he laid the basis for quantitative cardiac measurements from the chest X-ray.

To make angiocardiography of the heart possible, the feasibility of human cardiac catheterization had to be demonstrated. In 1929 W. Forssman (1904–1979) introduced ‘. . . a well oiled 65 cm long ureteral catheter’ into his antecubital vein to reach the right atrium. Soon thereafter he performed the first cardiac angiocardiogram on himself using 20 cc of 25% sodium iodide. Forssman shared the Nobel Prize for Medicine with A. Cournard and D. Richards in 1956.

The modern era of cardiac X-ray imaging began after the Second World War. G. Hounsfield of EMI Ltd tested their mathematical solutions and constructed the first clinical CT, which was installed in the Atkinson Morle Hospital in London in 1971 for brain scanning. This instrument revolutionized radiological imaging. Electronic and computer developments resulted in the image intensifier in 1952, which was a critical tool for analysing internal cardiac anatomy and the performing of selective coronary arteriography. Cormack and Hounsfield received the Nobel Prize for Physiology in 1979.  Subsequent major advances have been the dramatic increase in the speed of scanning and image reconstruction and improved image quality as a result of faster and more sophisticated computers. At the Mayo Clinic, dynamic volume scanning was achieved in 1975 with the dynamic spatial reconstructor which is based on multiple X-ray sources  and multiplex detectors for scanning the heart using the mathematical principles of CT.  Fast computed tomography, or electron beam tomography of the heart, was introduced by D. Boyd and co-workers in 1979 at Imatron. Contrary to the conventional CT scanner, this instrument has no moving parts and can acquire an image in as little as 50 ms, obviating the need for ECG-gating. By successively steering a small focal spot size electron beam at four tungsten target rings, producing a moving beam 180o about the patient, with a 180o ring of detectors, the heart is imaged virtually free of motion artifacts.

The existence of ultrasound was recognized by L. Spallanzani (1729–1799). He demonstrated that bats who are blind navigate by means of echo reflection using inaudible sound. In 1880, Jacques and Pierre Curie discovered the piezo-electric effect, a peculiar phenomenon observed in certain quartz crystals, which were the basis of early ultrasound systems and were later replaced by ferroelectric materials. The first suggestion that submerged objects could be located by echo-reflection probably came after theTitanic disaster in 1912. During World War I, P.Langevin (1872–1946) conceived the idea in 1917 of using a piezo-electric quartz crystal as both transmitter and receiver, and this ultimately led to the development of sonar which was completed with the invention of the cathode ray tube, extensively used in World War II for ship navigation and remote submarine detection.  In 1950, the German W. D. Keidel, also using an echo-transmission technique, performed the first cardiac examinations in an attempt to measure cardiac output.

In the late 1960s, the fibreoptic recorder, a spin-off from space technology, was introduced allowing the M-mode recording of all structures along the ultrasound beam: this constituted the definitive breakthrough in echocardiography. Today, M-mode echocardiography remains an important part of a complete cardiac ultrasound examination because of its high temporal resolution.  J Griffith and W Henry introduced the mechanical sector-scanner in 1974, in the same year that FL Thurstone and OT.von Ramm constructed their electronic phased-array scanner. Today, phased-array scanners are the most widely available tomographic imaging instruments with a tremendous impact on cardiac diagnosis. Recently, new computer technologies have enabled the development of volume-rendered data which display tissue information possible even in real-time.   The mono- and biplane electronic phased-array probes developed by J. Souquet in 1982 and his multiplane probe in 1985 represented the definitive clinical breakthrough of transoesophageal echocardiography.

The pulsed-wave Doppler technique allowed depth selection for blood flow velocity interrogation, but the major step forward for its clinical acceptance was its combination with imaging: the duplex scanner, reported by F. E. Barber et al. in 1974[35]. This development ultimately led to the integration of pulsed-wave Doppler with two-dimensional phased-array systems and allowed blood flow to be studied at selected regions within the image plane. The Bernouilli equation is now the cornerstone for Doppler assessment of cardiac haemodynamics and was published by the Dutch born D. Bernouilli (1700–1782) in his treatise ‘Hydrodynamica’ in 1738.  The rapid progress in interventional cardiology renewed the interest in imaging devices, allowing circumferential imaging of the arterial wall under the endothelial surface. Both mechanical single-element and multi-element electronic systems are now increasingly used.

De Hevesy introduced the red cell blood volume measurement and the1284 anniversary ‘dilution principle’ in humans using the first man-made radioisotope 32P produced by the cyclotron in Berkeley, a milestone invention by EO Lawrence in 1931 for which he received the Nobel Prize in 1939. With the cyclotron it was now possible to artificially produce radiopharmaceuticals and radionuclides, which became increasingly available for clinical research. Diagnostic nuclear imaging techniques can be divided into four general groups, depending on localization, dilution, flow or diffusion and biochemical and metabolic properties. Most of these basic principles were first demonstrated by de Hevesy using cyclotron-produced radioisotopes and techniques that he had described many years before—he should therefore be considered the ‘father of nuclear medicine’. It was the introduction of technetium-99m which spurred on the growth of nuclear medicine because of its ideal properties for gamma camera imaging, its short half life and the possibility of producing it in a hospital radiopharmacy. There are now radiopharmaceuticals labelled with 99mTc for almost every application in nuclear medicine. However, the clinical application of nuclear imaging required both counting and detection of radioisotope emissions. Modern counting equipment dates back to 1908 when H Geiger made his first electron counting tube, the precursor of the 1928 Geiger counter. The major breakthrough in radioisotope emission detection was the development of the scintillation scanner by B. Cassen in Los Angeles in 1949, an instrument rapidly followed by refinements. The scintillation camera was designed by Anger based on a concept proposed by DE Copeland and EW Benjamin and was followed by the electronic gamma camera in 1952, which is still the basis of the scintillation camera used today.

Single photon emission tomography (SPET) is based on the pioneering work of Kuhl and Edwards and the first clinical system became available in 1953. However, digital computer technology was necessary for emission tomography as we use it today and put the ‘C’ in SPECT. Tomographic capabilities have proved invaluable in the clinical use of nuclear imaging of the heart. Clinical application rapidly followed technical advances. Although Wren et al. laid the foundation of PET in 1951 it was Sweet and Brownell of Massachusetts General Hospital who conceived the idea of positron imaging which relies on the annihilation radiation emitted at 180o when positrons and electrons meet. PET has a clinical role in defining myocardial viability in patients with ischemic left  ventricular dysfunction who may benefit from revascularization rather than transplantation. It allows the sympathetic nervous system to be studied as regards the development of a number of cardiac disorders by receptor imaging. Although PET was developed before SPECT, it is less accessible because it requires direct access to a cyclotron to produce the short-lived positron emitting tracers and a radiopharmaceutical laboratory, which is not required for SPECT.

F Bloch et al. at Stanford and E Purcell et al. at Harvard in 1946 published a paper on the nuclear magnetic resonance (NMR) phenomenon in bulk matter for which they received the Nobel Prize in Physics in 1952. Initially, the major limitation to NMR spectroscopy in intact living systems was the small bore of the superconducting magnets. In the early 1980s, the Oxford Instrument Company started to produce superconducting magnets with increasing bores and extremely uniform and intense magnetic fields allowing the whole human body to be studied.  The major advantages of MRI are that contrary to ultrasound, the images are not degraded by overlying bony structures, that there is a high natural contrast between flowing blood and soft tissue, the wide field of view, and that cross-sections of the heart can be obtained in any arbitrary orientation. The ideal cardiovascular imaging technique would provide the cardiologist with integrated information on structure function, myocardial characteristics, perfusion and metabolism. Potentially, magnetic resonance imaging offers all this and will probably become the one-stop non-invasive diagnostic test of cardiology.

Real-time dynamic display of registered 4D cardiac MR and ultrasound images using a GQ Zhanga,

X Huanga, R Eagleson,G. Guiraudona, and TM Peters

University of Western Ontario, London, ON, Canada

In minimally invasive image-guided surgical interventions, different imaging modalities, such as magnetic resonance imaging (MRI) or computed tomography (CT), and real-time three-dimensional (3D) ultrasound (US), can provide complementary, multi-spectral image information. Multimodality dynamic image registration is a well-established approach that permits real-time diagnostic information to be enhanced by placing lower-quality real-time images within a high quality anatomical context. For the guidance of cardiac procedures, it would be valuable to register dynamic MRI or CT with intraoperative US. However, in practice, either the high computational cost prohibits such real-time visualization of volumetric multimodal images in a real-world medical environment, or else the resulting image quality is not satisfactory for accurate guidance during the intervention. Modern graphics processing units (GPUs) provide the programmability, parallelism and increased computational precision to begin to address this problem.

The Use of Rapid Prototyping in Clinical Applications

G Biglino, S Schievano and AM Taylor
UCL Institute of Cardiovascular Sciences, London
http://www.intechopen.com

Rapid prototyping broadly indicates the fabrication of a three-dimensional (3D) model from a computer-aided design (CAD), traditionally built layer by layer according to the 3D input (Laoui & Shaik, 2003). Rapid prototyping has also been indicated as solid free-form, computer-automated or layer manufacturing (Rengier et al., 2008). The development of this technique in the clinical world has been rendered possible by the concomitant advances in all its three fundamental steps:

1. Medical imaging (data acquisition),
2. Image processing (image segmentation and reconstruction by means of appropriate software) and
3. Rapid prototyping itself (3D printing).

Particular advantages in this discussion are:

1. Customised implants: Instead of using a standard implant and adapting it to the implantation site during the surgical procedure, rapid prototyping enables the fabrication of patient-specific implants, ensuring better fitting and reduced operation time.

2.  Microelectromechanical systems (MEMS): These are micro-sized objects that are fabricated by the same technique as integrated circuits. MEMS can have different. applications, including diagnostics (used in catheters, ultrasound intravascular diagnostics, angioplasty, ECG), pumping systems, drug delivery systems, monitoring, artificial organs, minimally invasive surgery.

Example: Stages of rapid prototyping in a clinical setting. From left to right: data acquisition (in this case with magnetic resonance (MR) imaging), image processing, 3D volume reconstruction with appropriate software (in this case, Mimics®, Materialise, Leuven, Belgium) and final 3D model printed in a transparent resin.

Despite its clinical use to the present day is still somewhat limited, considering the potential and flexibility of this technique, it is likely that applications of rapid prototyping such as individual patient care and academic research will be increasingly utilised (Rengier et al., 2010).

Nuclear Cardiology — In the Era of the Interventional Cardiology

B Baskot, I Ivanov, D Kovacevic, S Obradovic, N Ratkovic and M Zivkovic
Chap 10, InTech.  http://dx.doi.org/10.5772/55484

The strength and breadth of nuclear cardiology lie in its great potential for future creative growth. This growth involves the development of new biologically derived radiopharmaceuticals, advanced imaging techologies, and a broad/based set of research and clinical applications involving diagnosis, functional categorization, prognosis, evaluation of therapeutic interventions, and the ability to deal with many of the major investigative issues in contemporary cardiology such as myocardial hibernation, stunning, and viability. The past decade has been characterized by major advances in nuclear cardiology that have greatly enhanced the clinical utility of the various radionuclide techniques used for the assessment of regional myocardial perfusion and regional and global left ventricular function under resting and stress conditions. Despite the emergence of alternative noninvasive techniques for the diagnosis of coronary aretry disease (CAD) and the assessment of prognosis of viability, such as ergo- stress tests, stress echocardiography, the use and application of nuclear cardiology techniques have continued to increase.

For many years, planar imaging and SPECT with 201Tl (201 Thalium) constituted the only scintigraphic techniques available for detecting CAD and assessing prognosis in patients undergoing stress perfusion imaging. The major limitation of 201Tl scintigraphy is the high false/positive rate observed in many laboratories, which is attributed predominantly to image attenuation artefact and variants of normal that are interpreted as defects consequent to a significant coronary artery stenoses.

In recent years, new 99mTc (technetium) labeled perfusion agents have been introduced into clinical practice to enhance the specificity of Single Photon Emission Cumputed Tomography (SPECT) and to provide additional information regarding and global left ventricular systolic function via ECG gating of images [3, 4, 8]. It was immediately apparent that the quality of images obtained with these 99mTc-labeled radionuclides was superior to that images obtained with 201Tl because of the more favorable psysical characteristic of 99mTc imaging with gamma camera. Perhaps most importantly, 99mTc imaging allows easy gated acquisition, permitting simultaneous evaluation of regional systolic thickening, global left ventricular function (LVEF), and myocardial perfusion. One the most significant avdances in myocardial perfusion imaging in the past decade is the development of quantitative SPECT perfusion imaging.

Indications for nuclear cardiology procedures

CAD is still the single greatest cause of death of men and women in the world, despite a declining total death rate. The reduction of the morbidity and mortality due to CAD is thus primary importance. The first step in evaluating patients for CAD involves the assessment of the presence of traditional risk factors. Symptoms suggestive of CAD, in addition to other risk factors, drive decisions for further testing.
In patients able to exercise, the diagnostic accuracy of stress myocardial perfusion imaging (MPI) is significantly higher than the ETT alone and provides greater risk stratification for predicting the future cardiac events.

Nuclear cardiology –practical applications

  • ETT exercise treadmill test
  • DIP-ECHO dipyridamole echocardiography
  • DOB-ECHO dobutamine echocardiography
  • DIP- MIBI dipyridamole myocardial perfusion imaging with Tc-99m MIBI
  • DOB-MIBI dobutamine myocardial perfusion imaging with Tc-99m MIBI

Evaluating and determination CULPRIT lesion, an indication for interventional cardiology


One of the most powerfull uses of MPI is the evaluation of the risk for future events in patients with suspected or known CAD. Over the years, MPI has evolved as an essential tool in the evaluation and assessment of patient prior to coronary revascularization. It has a dual role. Prior to coronary angiography, MPI is extremely useful in documenting ischemia and determining the functional impact of single or multiple lesions subsequently identified. Despite some limitations in the setting of multivessel disease, MPI remains the test of choice for identifying the lesion responsible for the ischemic symptoms.  The primary objective of those study is to determine and localize the culprit lesion. The authors introduce parameters SRS (summary reversible score) and ISRS (index of summary reversible score), under the angiographically detected coronary narrowing ≥75% for the least one coronary artery. Coronary angiography, considered the “gold standard” for the diagnosis of CAD, often does not provide information about the physiologic significance of atherosclerotic lesions, especially in borderline lesions. More importantly, it does not provide a clear marker of risk of adverse events, especially in patients with moderate disease severity.  The presence of normal scintigraphic MPI study at a high level of stress ( ≥ 85 % of maximum predicted heart rate) or proper pharmacologic stress carries a very benign prognosis, with mortality rate less than 0.5% per year. This finding has been reproduced in many studies. Iskander and Iskandiran, pooling the results of SPECT imaging from more than 12000 patients in 14 studies, demonstrated that the events rate (death/MI) for patients with normal MPI finding is 0.6%, whereas abnormal study carries 7.4% per year event rate, a 12-fold increase.

The size and severity of the perfusion abnormality provide powerful prognostic information and has been shown to directly relate to outcome. MPI perfusion imaging and determination of culprit lesion is more predicitble of cardiac events than coronary angiography. As MPI imaging may identify those patients at high risk for subsequent cardiac events, perfusion imaging may be used to help guide further testing and revascularization procedures. Myocardial perfusion imaging provides information on the extent and location  of myocardial ischemia. The assessment of jeopardized myocardium may be performed and provides a measure of the relative value of PTCA in terms of the amount of jeopardized myocardium. The location of the stenosis may dictate the area at risk: extent and severity of perfusion defects were significantly smaller in patients with proximal compared with distal coronary artery occlusions.

The aim of the study Baskot at al.(*)  was to determine and localize culprit lesion by MPI in cases of angiographically detected coronary narrowing ≥ 75% of at least one coronary artery. In the study four hundred and thirty-seven [437] patients were studied. Angiographically detected significant coronary narrowing (≥ 75% luminal stenosis) was found in all before PCI. All the patients were submitted to MPI 99mTc-MIBI, with pharmacologic dipyridamole stress protocol with concomitant low level bicycle exercise 50 W (DipyEX). We measured relative uptake 99mTc-MIBI for each myocardial segment using short-axis tomogram study. A 5-point scoring system was used to assess the difference between uptake degree in stress and rest studies for the same segment, and we created two indices: Sum reversible score (SRS), Index of sum reversibility score (ISRS). In the results a total 1311 vascular territories (7429 segments) were analyzed before elective percutaneous coronary intervention (ePCI). Overall sensitivity, specificity and accuracy using SRS were 89.7%, 86, 7%, and 88, 2%, with a positive predictive value of 92, 7%. Overall sensitivity, specificity and accuracy using ISRS were 92.8%, 89.1%, and 92.3%, and the positive predictive value was 93.7%.

Pathophysiology and investigation of coronary artery disease

Ever D Grech
University of Manitoba, Winnipeg
BMJ 2003;326:1027–30

In affluent societies, coronary artery disease causes severe disability and more death than any other disease, including cancer. It manifests as angina, silent ischemia, unstable angina, myocardial infarction, arrhythmias, heart failure, and sudden death.  Coronary artery disease is almost always due to atheromatous narrowing and subsequent occlusion of the vessel. A mature plaque is composed of two constituents, each associated with a particular cell population. The lipid core is mainly released from necrotic “foam cells”—monocyte derived macrophages, which migrate into the intima and ingest lipids. The connective tissue matrix is derived from smooth muscle cells, which migrate from the media into the intima, where they proliferate and change their phenotype to form a fibrous capsule around the lipid core.

Stress echocardiography

Stress induced impairment of myocardial contraction is a sensitive marker of ischemia and precedes electrocardiographic changes and angina. Cross sectional echocardiography can be used to evaluate regional and global left ventricular impairment during ischaemia, which can be induced by exercise or an intravenous infusion of drugs that increase myocardial contraction and heart rate (such as dobutamine) or dilate coronary arterioles (such as dipyridamole or adenosine).

Radionuclide myocardial perfusion imaging

Thallium-201 or technetium-99m (99mTc-sestamibi, 99mTc-tetrofosmin) is injected intravenously at peak stress, and its myocardial distribution relates to coronary flow. Images are acquired with a gamma camera. This test can distinguish between reversible and irreversible ischemia (the latter signifying infarcted tissue). Although it is expensive and requires specialised equipment, it is useful in patients whose exercise test is non-diagnostic or whose exercise ability is limited.

A multigated acquisition (MUGA) scan assesses left ventricular function and can reveal salvageable myocardium in patients with chronic coronary artery disease. It can be performed with either thallium scintigraphy at rest or metabolic imaging with fluorodeoxyglucose by means of either positron emission tomography (PET) or single photon emission computed tomography (SPECT).

Intravascular ultrasound (IVUS)

In contrast to angiography, which gives a two dimensional luminal silhouette with little information about the vessel wall, intravascular ultrasound provides a cross sectional, three dimensional image of the full circumference of the artery. It allows precise measurement of plaque length and thickness and minimum lumen diameter, and it may also characterise the plaque’s composition. It is often used to clarify ambiguous angiographic findings and to identify wall dissections or thrombus. It is most useful during percutaneous coronary intervention, when target lesions can be assessed before, during, and after the procedure and at follow up. The procedure can also show that stents which seem to be well deployed on angiography are, in fact, suboptimally expanded.

Interventional Cardiology for Structural Heart Disease

Georgios Parcharidis
Hellenic J Cardiol 2012; 53: 403-404

Many questions arise from this “explosion” of new technologies. Is all this enthusiasm justified and supported by robust scientific evidence? Which is the best way to implement these new treatment options? What is the role of “traditional” surgical treatment? How can we decide which patient should be treated percutaneously and which surgically? What level of training and experience should an interventional cardiologist (or a centre) have in order to perform structural and/or congenital heart disease interventions?

With regard to the scientific evidence, it should be noted that, currently, the number of randomized clinical trials and the duration of follow up is quite limited. Thus, great caution should be exercised in patient selection and planning for these complex procedures. In addition, careful data collection and, ideally, inclusion in a patient registry would increase surveillance and, therefore, patient safety.

Notably, for the majority of structural and congenital heart diseases, surgery is still considered the “gold standard”. It is now globally accepted that decision making for patients with cardiovascular disease should be done in the context of a “Heart Team”, with close collaboration between cardiologists, cardiothoracic surgeons, anesthesiologists, imaging specialists and, occasionally, other specialists. Some patients will benefit more from transcatheter interventions whereas others will do better with surgery. Based on specific criteria, the role of the Heart Team is to identify (and treat) those patients.

PET vs. SPECT: Will PET Dominate Over the Next Decade?

DAIC  July/August 2013  pp28-31.  www. DIcardiology.com

The future success of PET may be grounded in its inherently better image resolution. In cardiac scanning, it has generally been reported that PET offers a resolution of 5 to 7 mm, compared with a cardiac SPECT resolution of 12 to 15 mm. Better performance has allowed data to emerge suggesting that as many as one in 10 scans interpreted as normal on SPECT would have been abnormal if done on PET due to the presence of unseen microvascular, triple-vessel disease. PET’s superior diagnostic capability is achieved partly through advances in hardware, particularly quantification, which leverages numerical precision to identify global perfusion defects in the heart that otherwise might be hidden from qualitative SPECT scans.

A big difference between the two technologies is the half-life of the isotope that each radiopharmaceutical tracer uses. SPECT tracers have a relatively long half-life (technetium-99m has a half-life of six hours), whereas rubidium-82 is only 75 seconds. This short half-life is a limitation of the current front-line cardiac PET radiotracer, which does not leave much room for error when imaging and presents the inability to do exercise stress testing. New iterative reconstruction (IR) software such as UltaSPECT is improving SPECT image quality by boosting the signal-to-noise ratio. Just as in CT scans, IR can also help reduce dose by enhancing lower-quality scans.

Part III

Heart Failure Patients

Heart Failure Complicating Non–ST-Segment Elevation Acute Coronary Syndrome -Timing, Predictors, and Clinical Outcomes

MC Bahit, RD Lopes, RM Clare, LK Newby,KS Pieper, et al.
J Am Coll Cardiol HF 2013;1(3): 223–9This study sought to describe the occurrence and timing of heart failure (HF), associated clinical factors, and 30-day outcomes in patients with non–ST-segment elevation acute coronary syndromes (NSTE-ACS). Using pooled patient-level data from 7 clinical trials from 1994 to 2008, we describe the occurrence and timing of HF,associated clinical factors, and 30-day outcomes in NSTE-ACS patients. HF at presentation was defined as Killip classes II to III; patients with Killip class IV or cardiogenic shock were excluded. New in-hospital cases of HF included new pulmonary edema. After adjusting for baseline variables, we created logistic regression models to identify clinical factors associated with HF at presentation and to determine the association between HF and 30-day mortality.Of 46,519 NSTE-ACS patients, 4,910 (10.6%) had HF at presentation. Of the 41,609 with no HF at presentation, 1,194 (2.9%) developed HF during hospitalization. A total of 40,415 (86.9%) had no HF at any time. Patients presenting with or developing HF during hospitalization were older, more often female, and had a higher risk of death at 30 days than patients without HF (adjusted odds ratio [OR]: 1.74; 95% confidence interval: 1.35 to 2.26). Older age, higher presenting heart rate, diabetes, prior myocardial infarction (MI), and enrolling MI were significantly associated with HF during hospitalization. In this large cohort of NSTE-ACS patients, presenting with or developing HF during hospitalization was associated with an increased risk of 30-day mortality.

Outcomes Following Heart Transplantation among Those Bridged with VAD

Jeffrey Shuhaiber MD
University of Cincinnati and Cincinnati Children’s Hospital
www.intechopen.com

Clinical assessment of outcome for post heart transplant recipients who were bridged with ventricular assist device is essential for service evaluation, device evaluation and audit. We will review the clinical outcomes measured so far in the field of heart transplant recipients who were bridged with VAD. In this chapter we will review the ongoing methods of assessment of outcomes for transplant recipients bridged by VAD and discuss the potential challenges facing the clinicians. We will finalize with brief conclusions and future directions.

Survival following heart transplantation: Does VAD Type matter?

There have been many clinical studies comparing outcomes following heart transplantation. Only one has been done in a multicenter fashion with clinically relevant as well as a robust risk-adjustment. In 2006 we asked the question- does survival differ between those who did and did not receive the left ventricular assist device (LVAD) following heart transplantation? And in summary we found that survival following heart transplantation for patients who received an LVAD prior to transplantation was comparable to those who did not receive an LVAD. The results of this study were published as lead research article in the British Medical Journal earlier this year (Shuhaiber).

We reviewed all patients above 18 years of age who received heart transplants registered in the United Network for Organ Sharing (UNOS) Registry from 1996 to 2004. The study included 2786 status 1/1A/1B heart transplant patients. We used the entry data for all patients who received LVAD pulsatile device. Our study design included a prospective cohort study in which post-transplant survival between patients who received an LVAD and those who did not receive an LVAD was compared.

1:1 propensity score matching analysis was also performed. Comparisons of survival distributions were made using the Kaplan-Meier method and the risk ratios were estimated using Cox proportional model. Our primary outcomes as well as risks and exposures included survival following heart transplantation in heart transplant recipients who did or did not receive ventricular assist device. The strength of the study was in adopting a robust statistical methodology that can adequately control for confounding variables. A stratified  propensity score analysis of data revealed that the risk of death following heart transplantation in an LVAD patient was not significantly different from those who did not have an LVAD within each stratum (see table for estimated hazard ratios and their 95% confidence intervals). A 1:1 propensity score matching analysis also revealed no significant difference in post heart transplant survival between the two groups (hazard ratio = 1.18, 95% CIs=0.75 to1.86). The propensity score matching was performed in order to control potential selection biases that can lead to a false association (or false lack of association) between LVAD and survival.

Part IV

Mechanical Heart Devices

The treatment of heart failure at end stage myocardial function has depended on having patients on waiting lists until the time that a donor heart becomes available.  Waiting times are within 1.5 to 4.5 years.  This required the development for mechanical support until a suitable donor is found.  The expectation for future devices will be that suitable mechanical heart assist devices for selected patients will possibly alleviate the need for a donor heart.

There are two main types of mechanical assist devices.  One type ios actually a total artificial heart, and the other is an assist that in complementary to the still functioning weak left ventricle.  The VAD was just discussed in the preceding discussion.  It has a pump that is attached to the atria and the pump controls the flow of blood through the pulmonary circulation.  This device is extremely important for patients who have sufficient LV function to not require a TAH.

The total artificial heart  (TAH) has been dominated by use of either of two models – the Syncardia temporary artificial heart, and the AbiCor.  The difference between them is that one has an externalization outside the thorax to an electrical source.  The Syncardia model is a modern day improvement of Jarvik-7.
The controlled flow is a miniature motor that has a rotor that moves the blood forward.  Of course, it presents a problem with respect to blood cell damage and anemia.  One of the innovations to the blood flow control has been that it flows without a heart beat.  The most significant innovation is the entry into the market of a new model, the Carmat, from France.  The Carmat would reduce the hemolysis that is associated with the flow of RBCs along a synthetic lining.  How?  It has the blood in contact with a cow skin lining.

Part V

Heart Transplant


The heart transplant is a technique that has been mastered at a number of excellent cardiothoracic surgical sites, and the facilities are being replaced by Hybrid Units that accommodate cardiology and surgical interventions. This brings to fruition the concept of a “Heart Team”.  The procedure has risks of complication, either in the patient condition, or in environmental, or other factors the surgeon has no control over.

These factors include, associated comorbidities, such as

  • diabetes mellitus
  • Late NYHF Stage 4
  • Late stage renal disease
  • mismatch of Graft vs Host
  • infection

Other related articles published on this Open Access Online Scientific Journal, include the following: 

Pearlman, JD and A. Lev-Ari, Cardiovascular Complications: Death from Reoperative Sternotomy after prior CABG, MVR, AVR, or Radiation; Complications of PCI; Sepsis from Cardiovascular Interventions

http://pharmaceuticalintelligence.com/2013/07/23/cardiovascular-complications-of-multiple-etiologies-repeat-sternotomy-post-cabg-or-avr-post-pci-pad-endoscopy-andor-resultant-of-systemic-sepsis/

Larry H Bernstein, Advanced Topics in Sepsis and the Cardiovascular System at its End Stage

http://pharmaceuticalintelligence.com/2013/08/18/advanced-topics-in-sepsis-and-the-cardiovascular-system-at-its-end-stage/

Pearlman, JD and A. Lev-Ari  Cardiac Resynchronization Therapy (CRT) to Arrhythmias: Pacemaker/Implantable Cardioverter Defibrillator (ICD) Insertion

http://pharmaceuticalintelligence.com/2013/07/22/cardiac-resynchronization-therapy-crt-to-arrhythmias-pacemakerimplantable-cardioverter-defibrillator-icd-insertion/

Lev-Ari, A.  3D Cardiovascular Theater – Hybrid Cath Lab/OR Suite, Hybrid Surgery, Complications Post PCI and Repeat Sternotomy

http://pharmaceuticalintelligence.com/2013/07/19/3d-cardiovascular-theater-hybrid-cath-labor-suite-hybrid-surgery-complications-post-pci-and-repeat-sternotomy/

Read Full Post »

Calcium Cycling (ATPase Pump) in Cardiac Gene Therapy: Inhalable Gene Therapy for Pulmonary Arterial Hypertension and Percutaneous Intra-coronary Artery Infusion for Heart Failure: Contributions by Roger J. Hajjar, MD

Calcium Cycling (ATPase Pump) in Cardiac Gene Therapy: Inhalable Gene Therapy for Pulmonary Arterial Hypertension and Percutaneous Intra-coronary Artery Infusion for Heart Failure: Contributions by Roger J. Hajjar, MD

Curator: Aviva Lev-Ari, PhD, RN

This image has an empty alt attribute; its file name is ArticleID-73.png

WordCloud Image Produced by Adam Tubman

Article VI Calcium Cycling (ATPase Pump) in Cardiac Gene Therapy Inhalable Gene Therapy for Pulmonary Arterial Hypertension and Percutaneous Intra-coronary Artery Infusion for Heart

Image created by Adina Hazan 06/30/2021

This article is Part VI in a Series of articles on Calcium Release Mechanism, the series consists of the following articles:

Part I: Identification of Biomarkers that are Related to the Actin Cytoskeleton

Larry H Bernstein, MD, FCAP

http://pharmaceuticalintelligence.com/2012/12/10/identification-of-biomarkers-that-are-related-to-the-actin-cytoskeleton/

Part II: Role of Calcium, the Actin Skeleton, and Lipid Structures in Signaling and Cell Motility

Larry H. Bernstein, MD, FCAP, Stephen Williams, PhD and Aviva Lev-Ari, PhD, RN

http://pharmaceuticalintelligence.com/2013/08/26/role-of-calcium-the-actin-skeleton-and-lipid-structures-in-signaling-and-cell-motility/

Part III: Renal Distal Tubular Ca2+ Exchange Mechanism in Health and Disease

Larry H. Bernstein, MD, FCAP, Stephen J. Williams, PhD
 and Aviva Lev-Ari, PhD, RN

http://pharmaceuticalintelligence.com/2013/09/02/renal-distal-tubular-ca2-exchange-mechanism-in-health-and-disease/

Part IV: The Centrality of Ca(2+) Signaling and Cytoskeleton Involving Calmodulin Kinases and Ryanodine Receptors in Cardiac Failure, Arterial Smooth Muscle, Post-ischemic Arrhythmia, Similarities and Differences, and Pharmaceutical Targets

Larry H Bernstein, MD, FCAP, Justin Pearlman, MD, PhD, FACC and Aviva Lev-Ari, PhD, RN

http://pharmaceuticalintelligence.com/2013/09/08/the-centrality-of-ca2-signaling-and-cytoskeleton-involving-calmodulin-kinases-and-ryanodine-receptors-in-cardiac-failure-arterial-smooth-muscle-post-ischemic-arrhythmia-similarities-and-differen/

Part V: Ca2+-Stimulated Exocytosis:  The Role of Calmodulin and Protein Kinase C in Ca2+ Regulation of Hormone and Neurotransmitter

Larry H Bernstein, MD, FCAP
and
Aviva Lev-Ari, PhD, RN

http://pharmaceuticalintelligence.com/2013/12/23/calmodulin-and-protein-kinase-c-drive-the-ca2-regulation-of-hormone-and-neurotransmitter-release-that-triggers-ca2-stimulated-exocytosis/

Part VI: Calcium Cycling (ATPase Pump) in Cardiac Gene Therapy: Inhalable Gene Therapy for Pulmonary Arterial Hypertension and Percutaneous Intra-coronary Artery Infusion for Heart Failure: Contributions by Roger J. Hajjar, MD

Aviva Lev-Ari, PhD, RN

http://pharmaceuticalintelligence.com/2013/08/01/calcium-molecule-in-cardiac-gene-therapy-inhalable-gene-therapy-for-pulmonary-arterial-hypertension-and-percutaneous-intra-coronary-artery-infusion-for-heart-failure-contributions-by-roger-j-hajjar/

Part VII: Cardiac Contractility & Myocardium Performance: Ventricular Arrhythmias and Non-ischemic Heart Failure – Therapeutic Implications for Cardiomyocyte Ryanopathy (Calcium Release-related Contractile Dysfunction) and Catecholamine Responses

Justin Pearlman, MD, PhD, FACC, Larry H Bernstein, MD, FCAP and Aviva Lev-Ari, PhD, RN

http://pharmaceuticalintelligence.com/2013/08/28/cardiac-contractility-myocardium-performance-ventricular-arrhythmias-and-non-ischemic-heart-failure-therapeutic-implications-for-cardiomyocyte-ryanopathy-calcium-release-related-contractile/

Part VIII: Disruption of Calcium Homeostasis: Cardiomyocytes and Vascular Smooth Muscle Cells: The Cardiac and Cardiovascular Calcium Signaling Mechanism

Justin Pearlman, MD, PhD, FACC, Larry H Bernstein, MD, FCAP and Aviva Lev-Ari, PhD, RN

http://pharmaceuticalintelligence.com/2013/09/12/disruption-of-calcium-homeostasis-cardiomyocytes-and-vascular-smooth-muscle-cells-the-cardiac-and-cardiovascular-calcium-signaling-mechanism/

Part IX: Calcium-Channel Blockers, Calcium Release-related Contractile Dysfunction (Ryanopathy) and Calcium as Neurotransmitter Sensor

Justin Pearlman, MD, PhD, FACC, Larry H Bernstein, MD, FCAP and Aviva Lev-Ari, PhD, RN

Part X: Synaptotagmin functions as a Calcium Sensor: How Calcium Ions Regulate the fusion of vesicles with cell membranes during Neurotransmission

Larry H Bernstein, MD, FCAP and Aviva Lev-Ari, PhD, RN

http://pharmaceuticalintelligence.com/2013/09/10/synaptotagmin-functions-as-a-calcium-sensor-how-calcium-ions-regulate-the-fusion-of-vesicles-with-cell-membranes-during-neurotransmission/

Part XI: Sensors and Signaling in Oxidative Stress

Larry H. Bernstein, MD, FCAP

http://pharmaceuticalintelligence.com/2013/11/01/sensors-and-signaling-in-oxidative-stress/

Part XII: Atherosclerosis Independence: Genetic Polymorphisms of Ion Channels Role in the Pathogenesis of Coronary Microvascular Dysfunction and Myocardial Ischemia (Coronary Artery Disease (CAD))

Larry H Bernstein, MD, FCAP and Aviva Lev-Ari, PhD, RN

http://pharmaceuticalintelligence.com/2013/12/21/genetic-polymorphisms-of-ion-channels-have-a-role-in-the-pathogenesis-of-coronary-microvascular-dysfunction-and-ischemic-heart-disease/

This article has THREE parts:

Part I: Scientific Leader in Cardiology, Contributions by Roger J. Hajjar, MD to Gene Therapy

Part II: Cardiac Gene Therapy: Inhalable Gene Therapy for Pulmonary Arterial Hypertension

Part III: Cardiac Gene Therapy: Percutaneous Intra-coronary Artery Infusion for Heart Failure

The following two discoveries in Cardiac Gene Therapies represent the FRONTIER IN CARDIOLOGY for 2012 – 2013: Solution Advancement for Improving Myocardial Contractility

Part I: Scientific Leader in Cardiology, Contributions by Roger J. Hajjar, MD to Gene Therapy

Roger J. Hajjar, MD, a pioneering Mount Sinai researcher who has published cutting-edge studies on heart failure, has been named the recipient of the 2013 BCVS Distinguished Achievement Award by theAmerican Heart Association and the Council on Basic Cardiovascular Sciences. Dr. Hajjar, who is The Arthur and Janet C. Ross Professor of Medicine and Director of The Helmsley Trust Translational Research Center, will be honored at the American Heart Association’s Scientific Sessions Annual Conference later this year.

“Dr. Hajjar will receive the award for his groundbreaking contributions to developing gene therapy treatments for cardiac disease,” says Joshua Hare, MD, who is President-elect of the Council on Basic Cardiovascular Sciences. He will also be recognized for his work on behalf of the Council.

Over the years, Dr. Hajjar’s laboratory has made important basic science discoveries that were translated into clinical trials. Most recently, Dr. Hajjar and his researchers identified a possible new drug target for treating or preventing heart failure. Says Mark A. Sussman, PhD, a former president of the Council, “Dr. Hajjar was among the first, and certainly the most successful, in combining gene therapy and treatment of heart failure. He shows a relentless pursuit of translating basic science into real-world treatment of heart disease.”

This article was first published in Inside Mount Sinai.

http://blog.mountsinai.org/blog/roger-j-hajjar-md-to-be-honored-for-research/

John Hopkins, Distinguished Alumnus Award 2011

Roger J. Hajjar, Engr ’86
Dr. Roger Hajjar received his bachelor’s degree in biomedical engineering from Johns Hopkins University in 1986. A cardiologist and translational scientist, he is a leader in gene therapy techniques and model testing for cardiovascular diseases. Dr. Hajjar is professor of medicine and cardiology, and professor of gene and cell medicine at Mount Sinai Medical Center in New York, as well as research director of Mount Sinai’s Wiener Family Cardiovascular Research Laboratories. Dr. Hajjar was recruited to Mt. Sinai from Harvard Medical School where he was assistant professor of medicine and staff cardiologist in the Heart Failure & Cardiac Transplantation Center. He received his medical degree from Harvard Medical School and trained in internal medicine and cardiology at Massachusetts General Hospital in Boston. Dr. Hajjar has concentrated his research efforts on understanding the basic mechanisms of heart failure. He has developed gene transfer methods and techniques in the heart to improve contractility. Dr. Hajjar’s laboratory focuses on targeting signaling pathways in cardiac myocytes to improve contractile function in heart failure and to block signaling pathways in hypertrophy and apoptosis. Dr. Hajjar has significant expertise in gene therapy. In 1996, he won the Young Investigator Award of the American Heart Association (Council on Circulation). In 1999, Dr. Hajjar was awarded the prestigious Doris Duke Clinical Scientist award and won first prize at the Astra Zeneca Young Investigator Forum. Dr. Hajjar holds a number of NIH grants.

http://alumni.jhu.edu/distinguishedalumni2011

Dr Hajjar is the Director of the Cardiovascular Research Center, and the Arthur & Janet C. Ross Professor of Medicine at Mount Sinai School of Medicine, New York, NY. He received his BS in Biomedical Engineering from Johns Hopkins University and his MD from Harvard Medical School and the Harvard-MIT Division of Health Sciences & Technology. He completed his training in internal medicine, cardiology and research fellowships at Massachusetts General Hospital in Boston.

Dr. Hajjar is an internationally renowned scientific leader in the field of cardiac gene therapy for heart failure. His laboratory focuses on molecular mechanisms of heart failure and has validated the cardiac sarcoplasmic reticulum calcium ATPase pump, SERCA2a, as a target in heart failure, developed methodologies for cardiac directed gene transfer that are currently used by investigators throughout the world, and examined the functional consequences of SERCA2a gene transfer in failing hearts. His basic science laboratory remains one of the preeminent laboratories for the investigation of calcium cycling in failing hearts and targeted gene transfer in various animal models. The significance of Dr Hajjar’s research has been recognized with the initiation and recent successful completion of phase 1 and phase 2 First-in-Man clinical trials of SERCA2a gene transfer in patients with advanced heart failure under his guidance.

Prior to joining Mount Sinai, Dr. Hajjar served as Director of the Cardiovascular Laboratory of Integrative Physiology and Imaging at Massachusetts General Hospital and Associate Professor of Medicine at Harvard Medical School. Dr. Hajjar has also been a staff cardiologist in the Heart Failure & Cardiac Transplantation Center at Massachusetts General Hospital.

Dr. Hajjar has won numerous awards and distinctions, including the Young Investigator Award of the American Heart Association. He was awarded a Doris Duke Clinical Scientist award and has won first prize at the Astra Zeneca Young Investigator Forum. He is a member of the American Society for Clinical Investigation. He was recently awarded the Distinguished Alumnus Award from Johns Hopkins University and the Mount Sinai Dean’s award for Excellence in Translational Science. He has authored over 260 peer-reviewed publications.

http://heart.sdsu.edu/~website/IRRI/Pages/faculty/roger-hajjar-md.html

Meet the Director of Mount Sinai’s Cardiovascular Research Center

“Cardiovascular diseases are the number one cause of death globally. In order to tackle them in all aspects, we must unite improved diagnostic techniques with more refined therapies.”

Roger J. Hajjar, MD, Director of the Cardiovascular Research Center, the Arthur & Janet C. Ross Professor of Medicine, Professor of Gene & Cell Medicine, Director of the Cardiology Fellowship Program, and Co-Director of the Transatlantic Cardiovascular Research Center, which combines Mount Sinai Cardiology Laboratories with those of the Universite de Paris – Madame Curie.

In the late 1990s, the possibility that discoveries in genetics and genomics could have a positive impact on the diagnosis, treatment, and prevention of cardiovascular diseases seemed to be just a distant promise. Today, a little more than a decade later, the promise is beginning to take shape. Roger J. Hajjar, MD and his multidisciplinary team of investigators are beginning to translate scientific findings into real therapies for cardiovascular diseases. As Director of the Cardiovascular Research Institute and a cardiologist by training, Dr. Hajjar guides the growth of a cutting-edge translational research laboratory, which is positioning Mount Sinai as the leader in cardiovascular genomics.

An internationally recognized scientific leader in the field of cardiac gene therapy for heart failure, Dr. Hajjar is expanding studies of the basic mechanisms of cardiac diseases and identification of high-risk groups and genomic predictors so that they can be part of the daily clinical care of patients. Unique biorepositories combined with cardiovascular areas of excellence across Mount Sinai make possible crucial genetic studies.

First Gene Therapy for Heart Failure

Under Dr. Hajjar’s leadership, the Cardiovascular Research Center has already developed the world’s first potential gene therapy for heart failure. Known as AAV1.SERCA2a, this therapy actually revives heart tissue that has stopped working properly. It has led to new treatment possibilities for patients with advanced heart failure, whose options used to be severely limited. The significance of this research has been recognized with the initiation and successful completion Phase 1 and Phase 2 First-in-Man clinical trials of SERCA2a gene transfer in patients with advanced heart failure. Phase 3 validation begins in 2011.

The Cardiovascular Research Center’s next research projects, already underway, focus on using novel gene therapy vectors to target diastolic heart failure, ventricular arrhythmias, pulmonary hypertension, and myocardial infarctions.

In addition to targeting signaling pathways to aid failing heart cells, ongoing work at the Cardiovascular Research Center involves studying how to block signaling pathways in cardiac hypertrophy as well as apoptosis. The laboratory team is also targeting a number of signaling pathways in the aging heart to improve dystolic function.

Prior to joining Mount Sinai in 2007, Dr. Hajjar served as Director of the Cardiovascular Laboratory of Integrative Physiology and Imaging at Massachusetts General Hospital and Associate Professor of Medicine at Harvard Medical School. Dr. Hajjar has also been a staff cardiologist in the Heart Failure & Cardiac Transplantation Center at Massachusetts General Hospital. After earning a bachelors of science degree in Biomedical Engineering from Johns Hopkins University and a medical degree from Harvard Medical School and the Harvard-MIT Division of Health Sciences and Technology, he completed his training in internal medicine, cardiology and research fellowships at Massachusetts General Hospital in Boston.

Scientific Advisors

Roger J. Hajjar, MD, Co-Founder and a Scientific Advisor of Celladon Co, plans to commercialize AAV1.SERCA2a for the treatment of heart failure.
Dr. Roger J. Hajjar is the Director of the Cardiovascular Research Center at the Mt. Sinai School of Medicine. Previously, he was the Director of the Cardiovascular Laboratory of Integrative Physiology and Imaging at Massachusetts General Hospital (MGH) and Associate Professor of Medicine at Harvard Medical School. Dr. Hajjar has an active basic science laboratory and concentrates his research efforts on understanding the basic mechanisms of heart failure. He has developed gene transfer methods and techniques targeting the heart as a therapeutic modality to improve contractility in heart failure. Dr. Hajjar’s laboratory focuses on targeting signaling pathways in cardiac myocytes to improve contractile function in heart failure and to block signaling pathways in hypertrophy and apoptosis.

Gene Therapy: Volume 19, Issue 6 (June 2012)

Special Issue: Cardiovascular Gene Therapy

Guest Editor

Roger J Hajjar MD, Mount Sinai School of Medicine, New York, NY Director, Cardiovascular Research Institute, Arthur & Janet C Ross Professor of Medicine

SDF-1 in myocardial repair  

M S Penn, J Pastore, T Miller and R Aras

Gene Ther 19: 583-587; doi:10.1038/gt.2012.32

Abstract | Full Text | PDF

Gene- and cell-based bio-artificial pacemaker: what basic and translational lessons have we learned?  

R A Li

Gene Ther 19: 588-595; doi:10.1038/gt.2012.33

Abstract | Full Text | PDF

Sarcoplasmic reticulum and calcium cycling targeting by gene therapy  

J-S Hulot, G Senyei and R J Hajjar

Gene Ther 19: 596-599; advance online publication, May 17, 2012; doi:10.1038/gt.2012.34

Abstract | Full Text | PDF

Gene therapy for ventricular tachyarrhythmias  

J K Donahue

Gene Ther 19: 600-605; advance online publication, April 26, 2012; doi:10.1038/gt.2012.35

Abstract | Full Text | PDF

Prospects for gene transfer for clinical heart failure  

T Tang, M H Gao and H Kirk Hammond

Gene Ther 19: 606-612; advance online publication, April 26, 2012; doi:10.1038/gt.2012.36

Abstract | Full Text | PDF

Targeting S100A1 in heart failure  

J Ritterhoff and P Most

Gene Ther 19: 613-621; advance online publication, February 16, 2012; doi:10.1038/gt.2012.8

Abstract | Full Text | PDF

VEGF gene therapy: therapeutic angiogenesis in the clinic and beyond  

M Giacca and S Zacchigna

Gene Ther 19: 622-629; advance online publication, March 1, 2012; doi:10.1038/gt.2012.17

Abstract | Full Text | PDF

Vein graft failure: current clinical practice and potential for gene therapeutics  

S Wan, S J George, C Berry and A H Baker

Gene Ther 19: 630-636; advance online publication, March 29, 2012; doi:10.1038/gt.2012.29

Abstract | Full Text | PDF

Percutaneous methods of vector delivery in preclinical models  

D Ladage, K Ishikawa, L Tilemann, J Müller-Ehmsen and Y Kawase

Gene Ther 19: 637-641; advance online publication, March 15, 2012; doi:10.1038/gt.2012.14

Abstract | Full Text | PDF

Lentiviral vectors and cardiovascular diseases: a genetic tool for manipulating cardiomyocyte differentiation and function  

E Di Pasquale, M V G Latronico, G S Jotti and G Condorelli

Gene Ther 19: 642-648; advance online publication, March 1, 2012; doi:10.1038/gt.2012.19

Abstract | Full Text | PDF

Intracellular transport of recombinant adeno-associated virus vectors  

M Nonnenmacher and T Weber

Gene Ther 19: 649-658; advance online publication, February 23, 2012; doi:10.1038/gt.2012.6

Abstract | Full Text | PDF

Gene delivery technologies for cardiac applications  

M G Katz, A S Fargnoli, L A Pritchette and C R Bridges

Gene Ther 19: 659-669; advance online publication, March 15, 2012; doi:10.1038/gt.2012.11

Abstract | Full Text | PDF

Cardiac gene therapy in large animals: bridge from bench to bedside  

K Ishikawa, L Tilemann, D Ladage, J Aguero, L Leonardson, K Fish and Y Kawase

Gene Ther 19: 670-677; advance online publication, February 2, 2012; doi:10.1038/gt.2012.3

Abstract | Full Text | PDF

Progress in gene therapy of dystrophic heart disease  

Y Lai and D Duan

Gene Ther 19: 678-685; advance online publication, February 9, 2012; doi:10.1038/gt.2012.10

Abstract | Full Text | PDF

Targeting GRK2 by gene therapy for heart failure: benefits above β-blockade  

J Reinkober, H Tscheschner, S T Pleger, P Most, H A Katus, W J Koch and P W J Raake

Gene Ther 19: 686-693; advance online publication, February 16, 2012; doi:10.1038/gt.2012.9

Abstract | Full Text | PDF

Directed evolution of novel adeno-associated viruses for therapeutic gene delivery  

M A Bartel, J R Weinstein and D V Schaffer

Gene Ther 19: 694-700; advance online publication, March 8, 2012; doi:10.1038/gt.2012.20

Abstract | Full Text | PDF

http://www.nature.com/gt/journal/v19/n6/index.html

Part II: Cardiac Gene Therapy: Inhalable Gene Therapy for Pulmonary Arterial Hypertension

Public release date: 30-Jul-2013

Contact: Lauren Woods
lauren.woods@mountsinai.org
212-241-2836
The Mount Sinai Hospital / Mount Sinai School of Medicine

Inhalable gene therapy may help pulmonary arterial hypertension patients

Gene therapy when inhaled may restore function of a crucial enzyme in the lungs to reverse deadly PAH

The deadly condition known as pulmonary arterial hypertension (PAH), which afflicts up to 150,000 Americans each year, may be reversible by using an inhalable gene therapy, report an international team of researchers led by investigators at the Cardiovascular Research Center at Icahn School of Medicine at Mount Sinai.

In their new study, reported in the July 30 issue of the journal Circulation, scientists demonstrated that gene therapy administered through a nebulizer-like inhalation device can completely reverse PAH in rat models of the disease. In the lab, researchers also showed in pulmonary artery PAH patient tissue samples reduced expression of the SERCA2a, an enzyme critical for proper pumping of calcium in calcium compartments within the cells. SERCA2a gene therapy could be sought as a promising therapeutic intervention in PAH.

“The gene therapy could be delivered very easily to patients through simple inhalation — just like the way nebulizers work to treat asthma,” says study co-senior investigator Roger J. Hajjar, MD, Director of the Cardiovascular Research Center and the Arthur & Janet C. Ross Professor of Medicine and Professor of Gene & Cell at Icahn School of Medicine at Mount Sinai. “We are excited about testing this therapy in PAH patients who are in critical need of intervention.”

This same SERCA2a dysfunction also occurs in heart failure. This new study utilizes the same gene therapy currently being tested in patients to reverse congestive heart failure in a large phase III clinical trial in the United States and Europe.

“What we have shown is that gene therapy restores function of this crucial enzyme in diseased lungs,” says Dr. Hajjar. “We are delighted with these new findings because it suggests that a gene therapy that is already showing great benefit in congestive heart failure patients may be able to help PAH patients who currently have no good treatment options — and are in critical need of a life sustaining therapy.”

When SERCA2a is down-regulated, calcium stays longer in the cells than it should, and it induces pathways that lead to overgrowth of new and enlarged cells. According to researchers, the delivery of the SERCA2a gene produces SERCA2a enzymes, which helps both heart and lung cells restore their proper use of calcium.

“We are now on a path toward PAH patient clinical trials in the near future,” says Dr. Hajjar, who developed the gene therapy approach. Studies in large animal models are now underway. SERCA2a gene therapy has already been approved by the National Institutes of Health for human study.

A Simple Inhalation Corrects Deadly Dysfunction

PAH most commonly results from heart failure in the left side of the heart or from a pulmonary embolism, when clots in the legs travel to the lungs and cause blockages. When the lung is damaged from these conditions, the tissue starts to quickly produce new and enlarged cells, which narrows pulmonary arteries. This increases the pressure inside them. The high pressure in these arteries resists the heart’s effort to pump through them and the blood flow between the heart and lungs is reduced. The right side of the heart then must overcome the resistance and work harder to push the blood through the pulmonary arteries into the lungs. Over time, the right ventricle becomes thickened and enlarged and heart failure develops.

The gene therapy that Dr. Hajjar developed uses a modified adeno-associated viral-vector that is derived from a parvovirus. It works by introducing a healthy SERCA2a gene into cells, but this gene does not incorporate into a patient’s chromosome, according to the study’s lead author, Lahouaria Hadri, PhD, an Instructor of Medicine in Cardiology at Icahn School of Medicine at Mount Sinai.

“The clinical trials in congestive heart failure have shown already that the gene therapy is very safe,” says Dr. Hadri. Between 40-50 percent of individuals have antecedent antibodies to the adeno-associated vectors, so potential patients need to be screened before gene therapy to make sure they are eligible to receive the vectors. In patients without antibodies, the restorative enzyme gene therapy does not cause an immune response, according to Dr. Hadri.

The clinical application of the gene therapy for patients with PAH will most likely differ from those with heart failure. The replacement gene needs to be injected through the coronary arteries of heart failure patients using catheters, while in PAH patients, the gene will need to be administered through inhalation.

This study was supported by National Institutes of Health grants (K01HL103176, K08111207, R01 HL078691, HL057263, HL071763, HL080498, HL083156, and R01 HL105301).

Other study co-authors include Razmig G. Kratlian, MD, Ludovic Benard, PhD, Kiyotake Ishikawa, MD, Jaume Aguero, MD, Dennis Ladage, MD, Irene C.Turnbull, MD, Erik Kohlbrenner, BA, Lifan Liang, MD, Jean-Sébastien Hulot, MD, PhD, and Yoshiaki Kawase, MD, from Icahn School of Medicine at Mount Sinai; Bradley A. Maron, MD and the study’s co-senior author Jane A. Leopold, MD, from Brigham and Women’s Hospital and Harvard Medical School in Boston, MA; Christophe Guignabert, PhD, from Hôpital Antoine-Béclère, Clamart, France; Peter Dorfmüller, MD, PhD, and Marc Humbert, MD, PhD, both of the Hôpital Antoine-Béclère and INSERM U999, Centre Chirurgical Marie-Lannelongue, Le Plessis-Robinson, France; Borja Ibanez, MD, from Fundación Centro Nacional de Investigaciones Cardiovasculares, Carlos III (CNIC), Madrid, Spain; and Krisztina Zsebo, PhD, of Celladon Corporation, San Diego, CA.

  • Dr. Hajjar and co-author Dr. Zsebo, have ownership interest in Celladon Corporation, which is developing AAV1.SERCA2a for the treatment of heart failure. Also,
  • Dr. Hajjar and co-authors Dr. Kawase and Dr. Ladage hold intellectual property around SERCA2a gene transfer as a treatment modality for PAH. In addition,
  • co-author Dr. Maron receives funding from Gilead Sciences, Inc. to study experimental pulmonary hypertension.
  • Other study co-authors have no financial interests to declare.

Therapeutic Efficacy of AAV1.SERCA2a in Monocrotaline-Induced Pulmonary Arterial Hypertension

  1. Lahouaria Hadri, PhD;
  2. Razmig G. Kratlian, MD;
  3. Ludovic Benard, PhD;
  4. Bradley A. Maron, MD;
  5. Peter Dorfmüller, MD, PhD;
  6. Dennis Ladage, MD;
  7. Christophe Guignabert, PhD;
  8. Kiyotake Ishikawa, MD;
  9. Jaume Aguero, MD;
  10. Borja Ibanez, MD;
  11. Irene C. Turnbull, MD;
  12. Erik Kohlbrenner, BA;
  13. Lifan Liang, MD;
  14. Krisztina Zsebo, PhD;
  15. Marc Humbert, MD, PhD;
  16. Jean-Sébastien Hulot, MD, PhD;
  17. Yoshiaki Kawase, MD;
  18. Roger J. Hajjar, MD*;
  19. Jane A. Leopold, MD*

+Author Affiliations


  1. From the Cardiovascular Research Center, Icahn School of Medicine at Mount Sinai, New York, NY (L.H., R.G.K., L.B., D.L., K.I., J.A., I.C.T., E.K., L.L., J.-S.H., Y.K., R.J.H.); Cardiovascular Medicine Division, Brigham and Women’s Hospital and Harvard Medical School, Boston, MA (B.A.M., J.A.L.); Hôpital Antoine-Béclère, Clamart, France (P.D., C.G., M.H.); INSERM U999, Centre Chirurgical Marie-Lannelongue, Le Plessis-Robinson, France (P.D., M.H.); Fundación Centro Nacional de Investigaciones Cardiovasculares, Carlos III (CNIC), Madrid, Spain (B.I.); and Celladon Corporation, San Diego, CA (K.Z.).
  1. Correspondence to Lahouaria Hadri, PhD, Cardiovascular Research Center, Box 1030, Icahn School of Medicine at Mount Sinai, 1470 Madison Ave, New York, NY 10029. E-mail lahouaria.hadri@mssm.edu

Abstract

Background—Pulmonary arterial hypertension (PAH) is characterized by dysregulated proliferation of pulmonary artery smooth muscle cells leading to (mal)adaptive vascular remodeling. In the systemic circulation, vascular injury is associated with downregulation of sarcoplasmic reticulum Ca2+-ATPase 2a (SERCA2a) and alterations in Ca2+homeostasis in vascular smooth muscle cells that stimulate proliferation. We, therefore, hypothesized that downregulation of SERCA2a is permissive for pulmonary vascular remodeling and the development of PAH.

Methods and Results—SERCA2a expression was decreased significantly in remodeled pulmonary arteries from patients with PAH and the rat monocrotaline model of PAH in comparison with controls. In human pulmonary artery smooth muscle cells in vitro, SERCA2a overexpression by gene transfer decreased proliferation and migration significantly by inhibiting NFAT/STAT3. Overexpresion of SERCA2a in human pulmonary artery endothelial cells in vitro increased endothelial nitric oxide synthase expression and activation. In monocrotaline rats with established PAH, gene transfer of SERCA2a via intratracheal delivery of aerosolized adeno-associated virus serotype 1 (AAV1) carrying the human SERCA2a gene (AAV1.SERCA2a) decreased pulmonary artery pressure, vascular remodeling, right ventricular hypertrophy, and fibrosis in comparison with monocrotaline-PAH rats treated with a control AAV1 carrying β-galactosidase or saline. In a prevention protocol, aerosolized AAV1.SERCA2a delivered at the time of monocrotaline administration limited adverse hemodynamic profiles and indices of pulmonary and cardiac remodeling in comparison with rats administered AAV1 carrying β-galactosidase or saline.

Conclusions—Downregulation of SERCA2a plays a critical role in modulating the vascular and right ventricular pathophenotype associated with PAH. Selective pulmonary SERCA2a gene transfer may offer benefit as a therapeutic intervention in PAH.

Key Words:

  • Received January 24, 2013.
  • Accepted June 13, 2013.

http://circ.ahajournals.org/content/128/5/512.abstract?sid=9b3b4fcc-e158-4e5d-bb8b-125586e2ec12

Circulation.2013; 128: 512-523 Published online before print June 26, 2013,doi: 10.1161/​CIRCULATIONAHA.113.001585

Part III: Cardiac Gene Therapy: Percutaneous Intra-coronary Artery Infusion for Heart Failure

Etiology of Heart Failure

  • Alcoholic
  • Hypertensive
  • Idiopathic
  • Inflammatory
  • Ischemic
  • Pregnancy-related
  • Toxic
  • Valvular Heart DIsease

Administration of Cardiac Gene Therapy for Heart Failure: via Percutaneous Intra-coronary Artery Infusion

  • Gene delivery to viable myocardium

dominance and coronary artery anatomy from angiography determines infusion scenario

  • Antegrade epicardial coronary artery infusion over 10 minutes

60 mL divided into 1,2,3 infusions depending on anatomy

Delivered via commercially available angiographic injection system & guide or diagnostic catheters

Dr. Roger J. Hajjar of the Mount Sinai School of Medicine will present at the ASGCT 15th Annual Meeting during a Scientific Symposium entitled: Cell and Gene Therapy in Cardiovascular Disease on Wednesday, May 16, 2012 at 8:00 am. Below is a brief preview of his presentation.

Roger J. Hajjar, MD

Mount Sinai School of Medicine

New York, NY

Novel Developments in Gene Therapy for Cardiovascular Diseases

Chronic heart failure is a leading cause of hospitalization affecting nearly 6 million people in the U.S. with 670,000 new cases diagnosed every year. Heart failure leads to about 280,000 deaths annually.

Congestive heart failure remains a progressive disease with a desperate need for innovative therapies to reverse the course of ventricular dysfunction. The most common symptoms of heart failure are shortness of breath, feeling tired and swelling in the ankles, feet, legs and sometimes the abdomen. Recent advances in understanding the molecular basis of myocardial dysfunction, together with the evolution of increasingly efficient gene transfer technology have placed heart failure within reach of gene-based therapies.

One of the key abnormalities in both human and experimental HF is a defect in sarcoplasmic reticulum (SR) function, which controls Ca2+ handling in cardiac myocytes on a beat to beat basis. Deficient SR Ca2+ uptake during relaxation has been identified in failing hearts from both humans and animal models and has been associated with a decrease in the activity of the SR Ca2+-ATPase (SERCA2a).

Over the last ten years we have undertaken a program of targeting important calcium cycling proteins in experimental models of heart by somatic gene transfer. This has led to the completion of a first-in-man phase 1 clinical trial of gene therapy for heart failure using adeno-associated vector (AAV) type 1 carrying SERCA2a. In this Phase I trial, there was evidence of clinically meaningful improvements in functional status and/or cardiac function which were observed in the majority of patients at various time points. The safety profile of AAV gene therapy along with the positive biological signals obtained from this phase 1 trial has led to the initiation and recent completion of a phase 2 trial of AAV1.SERCA2a in NYHA class III/IV patients. In the phase 2 trial, gene transfer of SERCA2a was found to be safe and associated with benefit in clinical outcomes, symptoms, functional status, NT-proBNP and cardiac structure.

The 12 month data presented showed that heart failure, which is a progressive disease, became stabilized in high dose AAV1.SERCA2a-treated patients: heart failure symptoms, exercise tolerance, serum biomarkers and cardiac function essentially improved or remained the same while these parameters deteriorated substantially in patients treated with placebo and concurrent optimal drug and device therapy. More recently, the 2-year CUPID data from long-term follow-up demonstrate a durable benefit in preventing major cardiovascular events.

The recent successful and safe completion of the CUPID trial along with the start of more recent phase 1 trials usher a new era for gene therapy for the treatment of heart failure. Furthermore, novel AAV derivatives with high cardiotropism and resistant to neutralizing antibodies are being developed to target a large number of cardiovascular diseases.

http://www.execinc.com/hosted/emails/asgct/file/Hajjar2(1).pdf

Power Point Presentation on Cardiac Gene Therapy –

VIEW SLIDE SHOW

http://my.americanheart.org/idc/groups/heart-public/@wcm/@global/documents/downloadable/ucm_311680.pdf

Gene Therapy for Heart Failure

  1. Lisa Tilemann,
  2. Kiyotake Ishikawa,
  3. Thomas Weber,
  4. Roger J. Hajjar

+Author Affiliations


  1. From the Cardiovascular Research Center, Mount Sinai Medical Center, New York, NY.
  1. Correspondence to Roger J. Hajjar, MD, Mount Sinai Medical Center, One Gustave Levy Place, Box 1030, New York, NY 10029. E-mail roger.hajjar@mssm.edu

Abstract

Congestive heart failure accounts for half a million deaths per year in the United States. Despite its place among the leading causes of morbidity, pharmacological and mechanic remedies have only been able to slow the progression of the disease. Today’s science has yet to provide a cure, and there are few therapeutic modalities available for patients with advanced heart failure. There is a critical need to explore new therapeutic approaches in heart failure, and gene therapy has emerged as a viable alternative. Recent advances in understanding of the molecular basis of myocardial dysfunction, together with the evolution of increasingly efficient gene transfer technology, have placed heart failure within reach of gene-based therapy. The recent successful and safe completion of a phase 2 trial targeting the sarcoplasmic reticulum calcium ATPase pump (SERCA2a), along with the start of more recent phase 1 trials, opens a new era for gene therapy for the treatment of heart failure.

Circulation Research.2012; 110: 777-793 doi: 10.1161/​CIRCRESAHA.111.252981

Key Words:

  • Received December 8, 2011.
  • Revision received January 29, 2012.
  • Accepted January 30, 2012.

Conclusions 

With a better understanding of the molecular mechanisms associated with heart failure and improved vectors with cardiotropic properties, gene therapy can now be considered as a viable adjunctive treatment to mechanical and pharmacological therapies for heart failure. In the coming years, more targets will emerge that are amenable to genetic manipulations, along with more advanced vector systems, which will undoubtedly lead to safer and more effective clinical trials in gene therapy for heart failure.

http://circres.ahajournals.org/content/110/5/777.full.pdf+html

Hijjar1
Figure 1.

AAV entry. 1 indicates receptor binding and endocytosis; 2, escape into cytoplasm; 3, nuclear import; 4, capsid disassembly; 5, double-strand synthesis; and 6, transcription.

Hijjar2

Figure 2.

Generation of mutant AAV library and directed evolution to identify cardiotropic AAVs. A, Creation of a library of AAVs through DNA shuffling.B, Selection of cardiotropic AAVs through directed evolution.

Hijjar3

Figure 3.

Antegrade coronary artery infusion. A, Coronary artery infusion. The vector is injected through a catheter without interruption of the coronary flow. B, Coronary artery infusion with occlusion of a coronary artery: The vector is injected through the lumen of an inflated angioplasty catheter. C, Coronary artery infusion with simultaneous blocking of a coronary artery and a coronary vein: The vector is injected through an inflated angioplasty catheter and resides in the coronary circulation until both balloons are deflated.

Hijjar4

Figure 4.

V-Focus system and retrograde coronary venous infusion. A, Recirculating antegrade coronary artery infusion: The vector is injected into a coronary artery, collected from the coronary sinus and after oxygenation readministered into the coronary artery. B, Retrograde coronary venous infusion with simultaneous blocking of a coronary artery and a coronary vein: The vector is injected into a coronary vein and resides in the coronary circulation until both balloons are deflated.

Hijjar5

Figure 5.

Direct myocardial injection and pericardial injection. A, Percutaneous myocardial injection: The vector is injected with an injection catheter via an endocardial approach.B, Surgical myocardial injection: The vector is injected via an epicardial approach. C, Percutaneous pericardial injection: The vector is injected via a substernal approach.

Hijjar6

Figure 6.

Excitation-contraction coupling in cardiac myocytes provides multiple targets for gene therapy.

SOURCE

http://circres.ahajournals.org/content/110/5/777.figures-only

Articles citing this article

  • ‘Ryanopathy’: causes and manifestations of RyR2 dysfunction in heart failureCardiovasc Res. 2013;98:240-247,
  • Up-regulation of sarcoplasmic reticulum Ca2+ uptake leads to cardiac hypertrophy, contractile dysfunction and early mortality in mice deficient in CASQ2Cardiovasc Res. 2013;98:297-306,
  • Myocardial Delivery of Stromal Cell-Derived Factor 1 in Patients With Ischemic Heart Disease: Safe and PromisingCirc. Res.. 2013;112:746-747,
  • Circulation Research Thematic Synopsis: Cardiovascular GeneticsCirc. Res.. 2013;112:e34-e50,
  • Gene and cytokine therapy for heart failure: molecular mechanisms in the improvement of cardiac functionAm. J. Physiol. Heart Circ. Physiol.. 2012;303:H501-H512,
  • Ryanodine Receptor Phosphorylation and Heart Failure: Phasing Out S2808 and “Criminalizing” S2814Circ. Res.. 2012;110:1398-1402,

http://circres.ahajournals.org/content/110/5/777.figures-only

For 154 References on Cardiac Gene Therapy

http://circres.ahajournals.org/content/110/5/777.full.pdf+html

Read Full Post »

 

FDA Recalls GE’s Infinia Hawkeye 4 Nuclear Medicine System used in Nuclear Medicine Imaging for Detection of Radioisotope Tracer Uptake in the Patient’s body

Reporter: Aviva Lev-Ari, PhD, RN

Hospital Death Forces Recall of GE Healthcare‘s Nuclear Medicine Machines

7/30/2013 7:36:26 AM

Staying up-to-date has never been simpler. Sign up for the free GenePool newsletter today!

Hospital patients face delays after 120 nuclear medicine machines were recalled across Australia following the death of a patient in the US. Authorities ordered hospitals across Australia to stop using the nuclear medicine imaging systems, preventing patients from being scanned while the machines are checked for safety. A 66-year-old patient being scanned in a veterans’ hospital in New York was crushed when a GE Healthcare Infinita Hawkeye 4 system collapsed when bolts securing the machine came loose.

http://www.devicespace.com/news_story.aspx?NewsEntityId=304157&type=email&source=DS_073013

 

Hospital death forces recall of nuclear medicine machines across Australia

HOSPITAL patients face delays after 120 nuclear medicine machines were recalled across Australia following the death of a patient in the US.

Authorities ordered hospitals across Australia to stop using the nuclear medicine imaging systems, preventing patients from being scanned while the machines are checked for safety.

A 66-year-old patient being scanned in a veterans’ hospital in New York was crushed when a GE Healthcare Infinita Hawkeye 4 system collapsed when bolts securing the machine came loose.

The recall notice was sent to Australian hospitals including the Women’s and Children’s Hospital more than a month later on July 9.

Six of 91 systems in Australian centres checked so far require repair to prevent a similar collapse, according to federal health officials, with 29 still to be checked.

Ten were operating in South Australian hospitals including two at the Royal Adelaide Hospital and one each at the Women’s and Children’s, the Queen Elizabeth Hospital and Lyell McEwin Hospital, with the others in private clinics.

GE Healthcare inspectors have inspected seven of these so far and not found any problems,.

SA Health, however, so far has only released one at the RAH and one at the QEH for use.

It released a statement to The Advertiser saying it had “a fleet of gamma cameras across South Australian public hospitals.”

“Five were identified as being in scope of the review,” the statement says. “Use of these five cameras was suspended immediately and GE is currently in the process of reviewing the machines. Two cameras have already been cleared and have resumed scanning.

“SA Health is working with GE Healthcare to minimise the impact on patients during this review.

“However some patient appointments have required rescheduling or rebooking on a different camera. There have been no incidents involving SA Health cameras.”

The systems, estimated to be worth from $300,000 to $800,000 depending on the model, track radiation emitted by radioactive fluids injected into patients to build images of organs and deep tissue to diagnose a range of diseases.

Information generated can pinpoint diseases before anatomical changes in organs and has some advantages over some other scanning techniques such as MRI and CAT scans.

Patients lie on their back with lead encased panels housing gamma cameras above and around them to track the radiation, and the entire machine can weigh in excess of 2000kg.

No deaths or injuries related to the safety issue have been reported in Australia.

The Therapeutic Goods Administration released a statement over the recall, advising patients to speak to their health professional if they have concerns.

“Due to the prevalence of affected nuclear medicine imaging systems in Australia and the need to have such systems inspected regarding this issue before use, there may be delays in accessing some diagnostic scan services,” the statement says.

In its letter to hospital officials GE Healthcare chief medical office Dr Douglas Hansell says: “Please be assured that maintaining a high level of safety and quality is our highest priority.’

http://www.news.com.au/national-news/south-australia/hospital-death-forces-recall-of-nuclear-medicine-machines-across-australia/story-fnii5yv4-1226680886436

 

GE Healthcare Nuclear Medicine Systems

Recall Class:  Class I

Date Recall Initiated: June 13, 2013

Products: Infinia Nuclear Medicine Systems, VG and VG Hawkeye Nuclear Medicine Systems, Helix Nuclear Medicine Systems, Brivo NM615, Discovery NM630, Optima NM/CT640, Discovery NM/CT670

Models: Infinia 3/8, Infinia-II 3/8, Infinia VC, Infinia II VC, Infinia 3/8 Hawkeye, Infinia VC Hawkeye, Infinia II 3/8 Hawkeye, Infinia II VC Hawkeye, Infinia II 3/8 HE4, Infinia II 5/8 HE4, Infinia II VC HE4, Varicam, Millennium VG 3/8, Millennium VG 5/8, Millennium VG 3/8 Hawkeye, Millennium VG 5/8 Hawkeye, Discovery VH, Helix nuclear medicine systems, Brivo NM615, Discovery NM630, Optima NM/CT640, Discovery NM/CT670

These affected products were distributed from October, 1992 through June, 2013.

Use:  These Nuclear Medicine systems are used to perform general Nuclear Medicine imaging procedures for detection of radioisotope tracer uptake in the patient’s body, using a variety of scanning modes supported by various acquisition types and optional imaging features designed to enhance image quality in Oncology, Cardiology, Neurology and other clinical diagnostic imaging applications. The scanning modes include planar (Static, Multi-gated, Dynamic, Whole body scanning) and tomographic (SPECT, Gated SPECT, Whole body SPECT, Camera based PET – also known as Coincidence Detection). Acquisition types include single and multi-isotope/multi-peak frame/list mode single-photon and positron imaging. Optional imaging-enhancement features include assortment of collimators, gating by physiological signals, real-time automatic body contouring, and CT-based attenuation correction and functional anatomic mapping.

Recalling Firm: 
GE Healthcare, LLC
3000 N Grandview Blvd.
Waukesha WI 53188-1615

Manufacturer:  
GE Medical System Israel Ltd
4 Hayozma St.
Tirat Hacarmel, Israel

Reason for Recall: GE Healthcare became aware of an incident at a VA Medical Center facility in the US. A patient died due to injuries sustained while being scanned on an Infinia Hawkeye 4 Nuclear Medicine System. On July 03, 2013 GE notified hospitals that they were recalling several Nuclear Medicine Imaging Systems because serious injuries or deaths could occur due to the failure mode associated with this recall. GE advised hospitals that they cease use of their Nuclear Medicine systems until GE can complete an inspection of the system. In the second notification, GE included all Nuclear Medicine Systems.

Public Contact: For questions about this recall contact GE Healthcare Service Representative at 1-800-437-1171

FDA District: Minneapolis District Office

FDA Comments:

On June 17, 2013 GE sent an Urgent Medical Device Correction letter to all affected customers. The letter identified the affected product, recommended that qualified service personnel maintain the equipment and that Preventative Maintenance procedures were executed according to labeling. In addition, the Safety Chapter Sections should be re-reviewed with personnel to ensure proper operation of the equipment.

On July 03, 2013 GE notified customers again via an Urgent Medical Device Recall letter (including confirmation of delivery for US customers) and follow-up telephone calls. Healthcare facilities are instructed to cease use of their Nuclear Medicine system until a GE Healthcare Field Engineer is able to do a complete inspection of the system and perform any necessary repairs at no cost. A GE Healthcare representative will contact the hospitals to arrange for the inspection.

Physicians: No action is required beyond the recommendations provided in the Urgent Medical Device Recall letter.

Health care professionals and consumers may report adverse reactions or quality problems they experienced using these products to MedWatch: The FDA Safety Information and Adverse Event Reporting Program either online, by regular mail or by FAX.

Additional Links

http://www.fda.gov/MedicalDevices/Safety/ListofRecalls/ucm362946.htm

–
–

Read Full Post »

Pacemakers, Implantable Cardioverter Defibrillators (ICD) and Cardiac Resynchronization Therapy (CRT)

Curators: Justin D Pearlman, MD, PhD, FACC and Aviva Lev-Ari, PhD, RN

Updated on 2/16/2015

Mild, non-ischemic heart failure might be more deadly than thought, an Austrian group found, calling for broader ICD use.

SOURCE

http://www.medpagetoday.com/Cardiology/Strokes/50048?isalert=1&uun=g99985d3527R5099207u&utm_source=breaking-news&utm_medium=email&utm_campaign=breaking-news&xid=NL_breakingnews_2015-02-16

 

The voice of our Series A Content Consultant: Justin D Pearlman, MD, PhD, FACC

Pacemakers place one or more wires into heart muscle to trigger electro-mechanically coupled contraction. A single wire to the right atrium is called an AAI pacemaker (atrial sensing, atrial triggering, inhibit triggering if sensed). A single wire to the right ventricle is called a VVI pacemaker (ventricular sensing, ventricular triggering, inhibit if sensed). With two wires to the heart more combinations are possible, including atrial-ventricular sequential activation, a closer mimic to normal function (DDDR pacemaker: dual sensing, dual triggering, dual functions, and rate-responsive to mimic exercise adjustment of heart rate). Three wires are used for synchronization: one to the right atrium, one to the right ventricle apex, and a third lead into a distal branch of the coronary sinus to activate the far side of the left ventricle. Resynchronization is used to compensate for a dilated ventricle, especially one with conduction delays, where the timing of activation is so unbalanced that the heart contraction approaches a wobbling motion rather than a well coordinated contraction. Adjusting timing of activation of the right ventricle and left ventricle can offset dysynchrony (unbalanced timing) and thereby increase the amount of blood ejected by each heart beat contraction (ejection fraction). Patients with dilated cardiomyopathy and significant conduction delays can improve the ejection fraction by 10 or more percentage points, which offers a significant improvement in exertion tolerance and heart failure symptoms.

Patients with ejection fraction below 35%, among others, have an elevated risk of life-ending arrhythmias such as ventricular tachycardia. Ventricular tachycardia is an extreme example of a wobbling heart in which the electrical activation sequence circles around the heart sequentially activating a portion and blocking its ability to respond until the electric signal comes around again. Whenever a portion of the heart is activated, ions shift location, and further activation of that region is not possible until sufficient time passes so that the compartmentalized ion concentrations can be restored (repolarization). Pacing can interrupt ventricular tachycardia by depolarizing a region that supported the circular activation pattern. Failing that, an electric shock can stop an ineffective rhythm. After all regions stop activation, they will generally reactivate in the normal pulsatile synchronous manner. An implanted cardiac defibrillator is a device designed to apply an internal electric shock to pause all activation and thereby interrupt ventricular tachycardia.
UPDATED on 12/31/2013

Published on Friday, 27 December 2013

S-ICD – Subcutaneous Implantable Cardioverter Defibrillator – Boston Scientific

Boston Scientific Subcutaneous Implantable Cardiodefibrillator Device S-ICD

S-ICD – Subcutaneous Implantable Cardioverter Defibrillator – Boston Scientific

Boston Scientific Subcutaneous Implantable Cardiodefibrillator Device S-ICD

‘Regular’ Pacemaker/ICD with Leads and a ‘Can’
When we think of Pacemakers and ICD’s we naturally think of a ‘Can’ and Leads that track down into the heart. Whilst these devices work fantastically well and will continue to do so. Unfortunately the ‘lead’ part of the device opens the door for a few complications to possibly arise. Those who have a Pacemaker or ICD will probably be familiar with concerns over;
  1. Systemic Infection – Infections travelling down the Leads into the Heart
  2. Lead Displacement – The Lead moving away from the heart tissue and thus becoming pretty useless.
  3. Vascular/Organ Injury – Damage to the blood vessels being used for access or perforation of heart wall.
  4. Pneumothorax (damage to the lining around the Lung), Haemothorax (build up of blood in the chest cavity), and air embolism (air bubble trapped in a blood vessel).
These complications are one of the key motivations behind developing ‘leadless’ devices the first of which the St Jude Nanostim, a small VVI Pacemaker that fits directly into the heart.
Another device to address these issues is the Boston Scientific S-ICD

What is the Boston Scientific S-ICD?

The S-ICD is what is sometimes referred to as a ‘shock box’ it does not have the pacemaker functionality that many other ICD’s do have. It is ONLY there to terminate dangerous Arrhythmias.
*It does not have the pacing functionality of traditional ICD‘s because it DOES NOT HAVE A LEAD THAT ENTERS THE HEART.*
It is not a Pacemaker!
 
Without the lead(s) ENTERING the heart via a blood vessel there is a reduction in the risks mentioned previously that are associated traditional device. Another of the benefits is that the S-ICD is positioned and implanted using anatomical landmarks (visible parts of your body) and not Fluoroscopy (video X-Ray) which reduces radiation exposure to the patient.

Positioning of the S-ICD.

Boston Scientific Subcutaneous Implantable Cardiodefibrillator Device S-ICD

The ‘Can‘ (metal box that contains all the circuitry and battery), is buried under the skin on the outside of the ribs. Put your arms down by your sides, the device would go where your ribs meet the middle of your bicep. A lead is then run under the skin to the centre of your chest where its is anchored and then north, under the skin again until the tip of the lead is roughly at the top of the sternum.
For you physicians out there the ‘can’ is positioned at the mid-axillary line between the 5th and 6th intercostal spaces, the lead is then tunnelled to a small Xiphoid incision and then tunnelled north to a superior incision.

How is an S-ICD Implanted?

VIEW VIDEO
Having spoken to Boston Scientific it is becoming more apparent that the superior incision (cut at the top of the chest) may actually be removed from the procedure guidance as simply tunnelling the lead and ‘wedging’ the tip at that point is satisfactory – THIS IS NOT CONFIRMED AT THE MOMENT AND IS THEREFORE NOT PROCEDURE ADVICE.
Boston Scientific Subcutaneous Implantable Cardiodefibrillator Device S-ICD
Image Courtesy of
http://www.bostonscientific.com/

How does the S-ICD Work?

A ‘Shock Box’ basically needs to do 2 things. Firstly be able to SENSE if the heart has entered a Dangerous Arrhythmia and Secondly, be able to treat it.
The treatment part of the functionality is the easy bit – it delivers an electric shock across a ‘circuit’ that involves a large amount of the tissue in the heart. The lead has two ‘electrodes’ and the ‘Can’ is a third electrode allowing you different shocking ‘vectors’. By vectors we mean directions and area through which the electricity travels during a shock. This gives us extra options when implanting a device as some vectors will work better than others for the treatment of dangerous arrhythmias.

Shocking Vectors?

This is a concept you are familiar with without even thinking about it… when you are watching ER or another TV program and they Defibrillate the patient using the metal paddles, where do they position them? One either side of the heart? Precisely!! this is creating a ‘vector’ across the heart to involve the cardiac tissue. The paddles would be a lot less effective if you put one on the knee and one on the foot!

Boston Scientific Subcutaneous Implantable Cardiodefibrillator Device S-ICD

Now because the ‘Vectors’ used by the S-ICD are over a larger area than those with a traditional device – more energy has to be delivered to have the same desired affect. The upshot of this is that a larger battery is required to deliver the 80J! Bigger Battery = Bigger Box. This image shows a demo device but this is the exact size compared to a One Pound Coin! Now yes it is big but because of the extra room where they place the device it is pretty discrete and hidden in even slender patients.
STAT ATTACK!
The S-ICD System delivers up to 5 shocks per episode at 80 J with up to 128 seconds of ECG storage per episode and storage of up to 45 episodes.
The heart rate that the S-ICD is told to deliver therapy is programable between 170 and 250 bpm. Quite cleverly the device is able to also deliver a small amount of ‘pacing’ after a shock, when the heart can often run slowly. This is external pacing and will be felt!! It can run for 30s.

Sensing in an S-ICD.

 
The S-ICD uses its electrodes to produce an ECG similar to a surface ECG. 
 
Now the Sensing functionality is the devices ability to determine what Rhythm the heart is in! Without a lead in the heart to give us really accurate information the device is using a large area of heart, ribs and muscle. This means there is more potential for ‘artefact’. Artefact is the electrical interference and confusion – that could potentially lead to a patient being shocked when they do not require it – or not being shocked when they do…
Boston Scientific have come up with a very clever software/algorithm called ‘Insight’. Insight uses 3 separate methods to determine the nature of a heart rhythm.
  • Normal Sinus Rhythm Template (Do your heart beats look as they should)
  • Dynamic Morphology Analysis (A live comparison of heart beat to previous heart beat, do they all look the same or do they keep changing?)
  • QRS Width analysis (Are the tall ‘peaks’ on your ECG, the QRS’, wider than they normally are?)
These questions (with some very complex maths) and the rate of a rhythm are used to decide whether to ‘shock’ or not.
Insight Algorithm S-ICD

Image Courtesy of  http://www.bostonscientific.com/

How does Insight and the S-ICD compare to other ICD Devices?

The statistics for treatment success and inappropriate shocks (an electrocuted patient that did not need to be) actually compare very similarly if not favourably compared to other devices on the market – these two studies are well worth a read if you have the time 🙂
1. Burke M, et al. Safety and Efficacy of a Subcutaneous Implantable-Debrillator (S-ICD System US IDE Study). Late-Breaking Abstract Session. HRS 2012.
2. Lambiase PD, et al. International Experience with a Subcutaneous ICD; Preliminary Results of the EFFORTLESS S-ICD Registry. Cardiostim 2012.
3. Gold MR, et al. Head-to-head comparison of arrhythmia discrimination performance of subcutaneous and transvenous ICD arrhythmia detection algorithms: the START study. J Cardiovasc Electrophysiol. 2012;23;4:359-366.
Who qualifies?
Template S-ICD Eligibility

Template used to assess eligibility!
Image Courtesy of
http://www.bostonscientific.com/
Well essentially anyone who qualifies for a normal ‘shock box’ ICD but with one other requirement. The Insight Software requires that a person has certain characteristics on their ECG. This is essentially showing that they have tall enough and narrow enough complexes to allow the algorithm to perform effectively. A simple 12 lead ECG Laying and Standing will be obtained and then a ‘Stencil’ is passed over the Print out – If the complexes fit within the boundaries marked on the ‘stencil’ then you potentially qualify. If your ECG does not meet requirements then it will not be recommended for you to have the S-ICD.

There you have it a quick overview of the Boston Scientific S-ICD.

Thanks for Reading

Cardiac Technician

SOURCE

http://www.thepad.pm/2013/12/boston-scientific-s-icd.html#!

UPDATED on 10/15/2013

Frequency and Determinants of Implantable Cardioverter Defibrillator Deployment Among Primary Prevention Candidates With Subsequent Sudden Cardiac Arrest in the Community

  1. Kumar Narayanan, MD;
  2. Kyndaron Reinier, PhD;
  3. Audrey Uy-Evanado, MD;
  4. Carmen Teodorescu, MD, PhD;
  5. Harpriya Chugh, BS;
  6. Eloi Marijon, MD;
  7. Karen Gunson, MD;
  8. Jonathan Jui, MD, MPH;
  9. Sumeet S. Chugh, MD

+Author Affiliations


  1. From The Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA (K.N., K.R., A.U.-E., C.T., H.C., E.M., S.S.C.); and Departments of Pathology (K.G.) and Emergency Medicine (J.J.), Oregon Health and Science University, Portland, OR.
  1. Correspondence to Sumeet S. Chugh, MD, Cedars-Sinai Medical Center, The Heart Institute, AHSP Suite A3100, 127 S. San Vicente Blvd., Los Angeles, CA 90048, Los Angeles, CA 90048. E-mail sumeet.chugh@cshs.org

Abstract

Background—The prevalence rates and influencing factors for deployment of primary prevention implantable cardioverter defibrillators (ICDs) among subjects who eventually experience sudden cardiac arrest in the general population have not been evaluated.

Methods and Results—Cases of adult sudden cardiac arrest with echocardiographic evaluation before the event were identified from the ongoing Oregon Sudden Unexpected Death Study (population approximately 1 million). Eligibility for primary ICD implantation was determined from medical records based on established guidelines. The frequency of prior primary ICD implantation in eligible subjects was evaluated, and ICD nonrecipients were characterized. Of 2093 cases (2003–2012), 448 had appropriate pre– sudden cardiac arrest left ventricular ejection fraction information available. Of these, 92 (20.5%) were eligible for primary ICD implantation, 304 (67.9%) were ineligible because of left ventricular ejection fraction >35%, and the remainder (52, 11.6%) had left ventricular ejection fraction ≤35% but were ineligible on the basis of clinical guideline criteria. Among eligible subjects, only 12 (13.0%; 95% confidence interval, 6.1%–19.9%) received a primary ICD. Compared with recipients, primary ICD nonrecipients were older (age at ejection fraction assessment, 67.1±13.6 versus 58.5±14.8 years, P=0.05), with 20% aged ≥80 years (versus 0% among recipients, P=0.11). Additionally, a subgroup (26%) had either a clinical history of dementia or were undergoing chronic dialysis.

Conclusions—Only one fifth of the sudden cardiac arrest cases in the community were eligible for a primary prevention ICD before the event, but among these, a small proportion (13%) were actually implanted. Although older age and comorbidity may explain nondeployment in a subgroup of these cases, other determinants such as socioeconomic factors, health insurance, patient preference, and clinical practice patterns warrant further detailed investigation.

Key Words:

  • Received March 11, 2013.
  • Accepted August 21, 2013

http://circ.ahajournals.org/content/128/16/1733.abstract

UPDATED on 9/15/2013

based on 9/6/2013 Trials and Fibrillations — The Heart.org

http://www.theheart.org/columns/trials-and-fibrillations-with-dr-john-mandrola/new-post-39.do#!

Echo-CRT trial: Most important study released at ESC 2013

Cardiac resynchronization therapy (CRT) is a multilead pacing device that can extend lives and improve the quality of life of selected patients who suffer from reduced performance of the heart due to adverse timing of contraction (wobbling motion from conduction delays that cause asynchrony or  delayed activation of one portion of the left ventricle compared to others reducing net blood ejection).

The degree of benefit in CRT responders depends not only on the degree of asynchrony, but also on the delayed activity location in relation to the available locations for lead placement. CRT is an adjustment in the timing of muscle activiation to improve the concerted impact on blood ejection. Only patients likely to improve should be exposed to the risks and costs of CRT.

The Echo-CRT trial, presented September 3, 2013 at the European Society of Cardiology (ESC) 2013 Congressand simultaneously published in the New England Journal of Medicine, helps identify which patients may benefit from CRT devices. (See Steve Stiles’ report on heartwire),

Echo-CRT trial summary

Background is important

Previous CRT studies enrolled patients with QRS duration >120 or >130 ms for synchronizing biventricular pacing. Additional work confirmed the greatest benefit occurred in patients with QRS durations >150 ms and typical left bundle branch block (LBBB). Conflicting observational and small randomized trials were less clear for patients with shorter QRS durations—the majority of heart-failure patients. What’s more, most cardiologists have seen patients with “modest” QRS durations respond to CRT. In theory, wide QRS is only expected if the axis of significant delay projects onto the standard ECG views, whereas significant opportunity for benefit can be missed if the axis of significant delay is not wide in the standard views. CRT implanters have heard of patients with normal-duration QRS where echo shows marked dyssynchrony. This raised the  question: Are there CHF patients with mechanical dyssynchrony (determined by echo) but no electrical delay (as measured by the ECG) benefit from CRT?Unfortunately, echo does not resolve the issue either. Thus there is the residual question of who should be evaluated by a true 3D syncrhony assessment by cardiac MRI.

Echocardiographic techniques held promise to identify mechanical dyssynchrony, but like the standard 12 lead ECG, they also utilize limited orientations of views of the heart and hence the directions in which delays can be detected. Cardiac MRI Research (not limited in view angle) by JDPearlman showed that the axis of maximal delay in patients with asynchrony is within 30 degrees of the ECG and echo views in a majority of patients with asynchrony, but it can be 70-110 degrees away from the views used by echocardiography and by ECG in 20% of cases. Hence some patients who may benefit can be missed by ECG or Echo criteria.

Methodology

Echo-CRT was an industry-sponsored (Biotronik) investigator-initiated prospective international randomized controlled trial. All patients had mechanical dyssynchrony by echo, QRS <130 ms, and an ICD indication. CRT-D devices were implanted in all patients. Blinded randomization to CRT-on (404 patients) vs CRT-off (405 patients) was performed after implantation. Programming in the CRT-off group was set to minimize RV pacing. The primary outcome was a composite of all-cause mortality or hospitalization.

Six key findings

1. Although entry criteria for the trial was a QRS duration <130 ms, the mean QRS duration of both groups was 105 ms.

2. The data safety monitoring board terminated the trial prematurely because of an increased death rate in the CRT group.

3. No differences were noted in the primary outcome.

4. More patients died in the CRT group (hazard ratio=1.8).

5. The higher death rate in the CRT group was driven by cardiovascular death.

6. More patients in the CRT group were hospitalized, due primarily to device-related issues.

These findings send clear and simple messages to all involved with treating patients with heart failure. My interpretation of Echo-CRT is as follows:

Do not implant CRT devices in patients with “narrow” QRS complexes.

The signal of increased death was strong. A hazard ratio of 1.8 translates to an almost doubling of the risk of death. This finding is unlikely to be a statistical anomaly, as it was driven by CV death. The risks of CRT in nonresponders are well-known and include: increased RV pacing, possible proarrhythmia from LV pacing, and the need for more device-related surgery. Patients who do not respond to CRT get none of the benefits but all the potential harms—an unfavorable ratio indeed.

Echo is not useful for assessing dyssynchrony in patients with narrow QRS complexes.

Dr Samuel Asirvatham explains the concept of electropathy in a review article in the Journal of Cardiovascular Electrophysiology. He teaches us that the later the LV lateral wall is activated relative to the RV, the more the benefit of preexciting the lateral wall with an LV lead. That’s why the benefit from CRT in many cases increases with QRS duration, because—in a majority—a wide QRS means late activation of the lateral LV.

Simple triumphs over complicated—CRT response best estimated with the old-fashioned ECG.

In a right bundle branch block, the left ventricle is activated first; in LBBB, the LV lateral wall is last, and with a nonspecific ICD, there’s delayed conduction in either the His-Purkinje system or in ventricular muscle. What does a normal QRS say? It says the wave front of activation as projected onto the electric views obtained activates the LV and RV simultaneously. If those views capture the worst delay then they can eliminate the  need for resynchrony.

CRT benefit with mild-moderate QRS prolongation still not settled

Dr Robert Myerburg (here and here) teaches us to make a distinction between trial entry criteria and the actual values of the cohort.

Consider how this applies to QRS duration:  COMPANION and CARE-HF are clinical trials that showed definitive CRT benefit. Entry required a QRS duration >120 ms (130 ms in CARE-HF). But the actual mean QRS duration of enrolled patients was 160 ms. A meta-analysis of CRT trials confirmed benefit at longer QRS durations and questioned it below 150 ms. CRT guideline recommendations incorporate study entry criteria, not the mean values of actual patients in the trial. Patients enrolled in Echo-CRT had very narrow QRS complexes (105 ms). What to recommend in the common situation when a patient with a typical LBBB has a QRS duration straddling 130 ms is not entirely clear. The results of Echo-CRT might have been different had the actual QRS duration values been closer to 130 ms.

Conclusion

Echo-CRT study reinforces expectations based on cardiac physiology. In the practice of medicine, it’s quite useful to know when not to do something.

The trial should not dampen enthusiasm for CRT. Rather, it should focus our attention to patient selection—and the value of the 12-lead ECG.

 References

Rethinking QRS Duration as an Indication for CRT

SMITA MEHTA M.D.1 and SAMUEL J. ASIRVATHAM M.D., F.A.C.C.2,3

Author Information

  1. Department of Pediatric Cardiology, Cleveland Clinic, Cleveland, Ohio, USA
  2. Division of Cardiovascular Diseases, Department of Medicine, Mayo Clinic, Rochester, Minnesota, USA
  3. Department of Pediatrics and Adolescent Medicine, Mayo Clinic, Rochester, Minnesota, USA

*Samuel J. Asirvatham, M.D., Division of Cardiovascular Diseases, Department of Internal Medicine and Division of Pediatric Cardiology, Department of Pediatric and Adolescent Medicine, Mayo Clinic College of Medicine, 200 First Street SW, Rochester, MN 55905, USA. E-mail: asirvatham.samuel@mayo.edu

J Cardiovasc Electrophysiol, Vol. 23, pp. 169-171, February 2012.

http://onlinelibrary.wiley.com/doi/10.1111/j.1540-8167.2011.02163.x/full

Indications for Implantable Cardioverter-Defibrillators Based on Evidence and Judgment FREE

Robert J. Myerburg, MD; Vivek Reddy, MD; Agustin Castellanos, MD
J Am Coll Cardiol. 2009;54(9):747-763. doi:10.1016/j.jacc.2009.03.078

Implantable Cardioverter–Defibrillators after Myocardial Infarction

Robert J. Myerburg, M.D.

Division of Cardiology, University of Miami Miller School of Medicine, Miami.

N Engl J Med 2008; 359:2245-2253 November 20, 2008DOI: 10.1056/NEJMra0803409

END OF UPDATE

Electrical conduction of the Human Heart

  • Physiology and
  • Genetics

were explained by us in the following articles:

Genetics of Conduction Disease: Atrioventricular (AV) Conduction Disease (block): Gene Mutations – Transcription, Excitability, and Energy Homeostasis

On Devices and On Algorithms: Prediction of Arrhythmia after Cardiac Surgery and ECG Prediction of an Onset of Paroxysmal Atrial Fibrillation

Dilated Cardiomyopathy: Decisions on implantable cardioverter-defibrillators (ICDs) using left ventricular ejection fraction (LVEF)

Reduction in Inappropriate Therapy and Mortality through ICD Programming

Below, we present the following complementary topics:

Options for Cardiac Resynchronization Therapy (CRT) to Arrhythmias:

  • Implantable Pacemaker
  • Insertable Programmable Cardioverter Defibrillator (ICD)

UPDATED 8/6/2013

Medtronic Pacemaker Recall

 

17/07/2013

Australia’s regulatory authority, the Therapeutic Goods Administration (TGA) has issued a hazard alert pertaining to one of Medtronic’s pacing devices, the Consulta® Cardiac Resynchronization Therapy Pacemaker (CRT-P). The alert coincides somewhat with Medtronic’s own issuance of a field safety notice concerning Consulta and Syncra® CRT-P devices.

Background

Consulta and Syncra CRT-Ps are implantable medical devices used to treat heart failure. The devices provide pacing to help coordinate the heart’s pumping action and improve blood flow.

The two devices are the subject of a global manufacturer recall after Medtronic had identified an issue with a subset of both during production, although as yet there had been no reported or confirmed device failures. However, because of the potential for malfunction, Medtronic is requiring the return of non-implanted devices manufactured between April 1 and May 13, 2013 for re-inspection.

Seemingly this manufacturing issue could compromise the sealing of the device. Should an out-of-spec weld fail this could result in body fluids entering the device, which could cause it to malfunction leading to loss of pacing output. This could potentially see the return of symptoms including

  • fainting or lightheadedness,
  • dyspnoea (shortness of breath),
  • fatigue and
  • oedema.

Medtronic’s recall is thought to relate to 265 devices, 44 of which have been implanted in the US.

The Australian warning letter, issued by the TGA states that only one “at risk” Consulta CRT-P device has been implanted in the country and there have been no reports of device failures or patient injuries relating to this issue.

Neither Medtronic nor the TGA are suggesting any specific patient management measures other than routine follow-up in accordance with labelling instructions.

Pacemaker/Implantable Cardioverter Defibrillator (ICD) Insertion

Procedure Overview

What is a pacemaker/implantable cardioverter defibrillator (ICD) insertion?

A pacemaker/implantable cardioverter defibrillator (ICD) insertion is a procedure in which a pacemaker and/or an ICD is inserted to assist in regulating problems with the heart rate (pacemaker) or heart rhythm (ICD).

Pacemaker

When a problem develops with the heart’s rhythm, such as a slow rhythm, a pacemaker may be selected for treatment. A pacemaker is a small electronic device composed of three parts: a generator, one or more leads, and an electrode on each lead. A pacemaker signals the heart to beat when the heartbeat is too slow.

Illustration of a single-chamber pacemaker
Click Image to Enlarge

A generator is the “brain” of the pacemaker device. It is a small metal case that contains electronic circuitry and a battery. The lead (or leads) is an insulated wire that is connected to the generator on one end, with the other end placed inside one of the heart’s chambers.

The electrode on the end of the lead touches the heart wall. In most pacemakers, the lead senses the heart’s electrical activity. This information is relayed to the generator by the lead.

If the heart’s rate is slower than the programmed limit, an electrical impulse is sent through the lead to the electrode and the pacemaker’s electrical impulse causes the heart to beat at a faster rate.

When the heart is beating at a rate faster than the programmed limit, the pacemaker will monitor the heart rate, but will not pace. No electrical impulses will be sent to the heart unless the heart’s natural rate falls below the pacemaker’s low limit.

Pacemaker leads may be positioned in the atrium or ventricle or both, depending on the condition requiring the pacemaker to be inserted. An atrial dysrhythmia/arrhythmia (an abnormal heart rhythm caused by a dysfunction of the sinus node or the development of another atrial pacemaker within the heart tissue that takes over the function of the sinus node) may be treated with an atrial pacemaker.

Illustration of a dual-chamber pacemaker
Click Image to Enlarge

A ventricular dysrhythmia/arrhythmia (an abnormal heart rhythm caused by a dysfunction of the sinus node, an interruption in the conduction pathways, or the development of another pacemaker within the heart tissue that takes over the function of the sinus node) may be treated with a ventricular pacemaker whose lead wire is located in the ventricle.

It is possible to have both atrial and ventricular dysrhythmias, and there are pacemakers that have lead wires positioned in both the atrium and the ventricle. There may be one lead wire for each chamber, or one lead wire may be capable of sensing and pacing both chambers.

A new type of pacemaker, called a biventricular pacemaker, is currently used in the treatment of congestive heart failure. Sometimes in heart failure, the two ventricles (lower heart chambers) do not pump together in a normal manner. When this happens, less blood is pumped by the heart.

A biventricular pacemaker paces both ventricles at the same time, increasing the amount of blood pumped by the heart. This type of treatment is called cardiac resynchronization therapy.

Implantable cardioverter defibrillator (ICD)

An implantable cardioverter defibrillator (ICD) looks very similar to a pacemaker, except that it is slightly larger. It has a generator, one or more leads, and an electrode for each lead. These components work very much like a pacemaker. However, the ICD is designed to deliver an electrical shock to the heart when the heart rate becomes dangerously fast, or €œfibrillates.”

An ICD senses when the heart is beating too fast and delivers an electrical shock to convert the fast rhythm to a normal rhythm. Some devices combine a pacemaker and ICD in one unit for persons who need both functions.

The ICD has another type of treatment for certain fast rhythms called anti-tachycardia pacing (ATP). When ATP is used, a fast pacing impulse is sent to correct the rhythm. After the shock is delivered, a “back-up” pacing mode is used if needed for a short while.

The procedure for inserting a pacemaker or an ICD is the same. The procedure generally is performed in an electrophysiology (EP) lab or a cardiac catheterization lab.

Other related procedures that may be used to assess the heart include resting and exercise electrocardiogram (ECG), Holter monitor, signal-averaged ECG, cardiac catheterization, chest x-ray, computed tomography (CT scan) of the chest, echocardiography, electrophysiology studies, magnetic resonance imaging (MRI) of the heart, myocardial perfusion scans, radionuclide angiography, and ultrafast CT scan.

The heart’s electrical conduction system

Illustration of the anatomy of the heart, view of the electrical system
Click Image to Enlarge

The heart is, in the simplest terms, a pump made up of muscle tissue. Like all pumps, the heart requires a source of energy in order to function. The heart’s pumping energy comes from an indwelling electrical conduction system.

An electrical stimulus is generated by the sinus node (also called the sinoatrial node, or SA node), which is a small mass of specialized tissue located in the right atrium (right upper chamber) of the heart.

The sinus node generates an electrical stimulus regularly at 60 to 100 times per minute under normal conditions. This electrical stimulus travels down through the conduction pathways (similar to the way electricity flows through power lines from the power plant to your house) and causes the heart’s chambers to contract and pump out blood.

The right and left atria (the two upper chambers of the heart) are stimulated first and contract a short period of time before the right and left ventricles (the two lower chambers of the heart).

The electrical impulse travels from the sinus node to the atrioventricular (AV) node, where it stops for a very short period, then continues down the conduction pathways via the “bundle of His” into the ventricles. The bundle of His divides into right and left pathways to provide electrical stimulation to both ventricles.

What is an ECG?

This electrical activity of the heart is measured by an electrocardiogram (ECG or EKG). By placing electrodes at specific locations on the body (chest, arms, and legs), a tracing of the electrical activity can be obtained. Changes in an ECG from the normal tracing can indicate one or more of several heart-related conditions.

Dysrhythmias/arrhythmias (abnormal heart rhythms) are diagnosed by methods such as EKG, Holter monitoring, signal-average EKG, or electrophysiological studies. These symptoms may be treated with medication or procedures such as a cardiac ablation (removal of a location in the heart that is causing a dysrhythmia by freezing or radiofrequency).

Reasons for the Procedure

A pacemaker may be inserted in order to provide stimulation for a faster heart rate when the heart is beating too slowly, and when other treatment methods, such as medication, have not improved the heart rate.

An ICD may be inserted in order to provide fast pacing (ATP), cardioversion (small shock), or defibrillation (larger shock) when the heart beats too fast.

Problems with the heart rhythm may cause difficulties because the heart is unable to pump an adequate amount of blood to the body. If the heart rate is too slow, the blood is pumped too slowly.

If the heart rate is too fast or too irregular, the heart chambers are unable to fill up with enough blood to pump out with each beat. When the body does not receive enough blood, symptoms such as fatigue, dizziness, fainting, and/or chest pain may occur.

Some examples of rhythm problems for which a pacemaker or ICD might be inserted include:

  • atrial fibrillation – occurs when the atria beat irregularly and too fast
  • ventricular fibrillation – occurs when the ventricles beat irregularly and too fast
  • bradycardia – occurs when the heart beats too slow
  • tachycardia – occurs when the heart beats too fast
  • heart block – occurs when the electrical signal is delayed after leaving the SA node; there are several types of heart blocks, and each one has a distinctive ECG tracing

There may be other reasons for your physician to recommend a pacemaker or ICD insertion.

Risks of the Procedure

Possible risks of pacemaker or ICD insertion include, but are not limited to, the following:

  • bleeding from the incision or catheter insertion site
  • damage to the vessel at the catheter insertion site
  • infection of the incision or catheter site
  • pneumothorax – air becomes trapped in the pleural space causing the lung to collapse

If you are pregnant or suspect that you may be pregnant, you should notify your physician. If you are lactating, or breastfeeding, you should notify your physician.

Patients who are allergic to or sensitive to medications or latex should notify their physician.

For some patients, having to lie still on the procedure table for the length of the procedure may cause some discomfort or pain.

There may be other risks depending upon your specific medical condition. Be sure to discuss any concerns with your physician prior to the procedure.

Before the Procedure

  • Your physician will explain the procedure to you and offer you the opportunity to ask any questions that you might have about the procedure.
  • You will be asked to sign a consent form that gives your permission to do the test. Read the form carefully and ask questions if something is not clear.
  • You will need to fast for a certain period of time prior to the procedure. Your physician will notify you how long to fast, usually overnight.
  • If you are pregnant or suspect that you are pregnant, you should notify your physician.
  • Notify your physician if you are sensitive to or are allergic to any medications, iodine, latex, tape, or anesthetic agents (local and general).
  • Notify your physician of all medications (prescription and over-the-counter) and herbal supplements that you are taking.
  • Notify your physician if you have heart valve disease, as you may need to receive an antibiotic prior to the procedure.
  • Notify your physician if you have a history of bleeding disorders or if you are taking any anticoagulant (blood-thinning) medications, aspirin, or other medications that affect blood clotting. It may be necessary for you to stop some of these medications prior to the procedure.
  • Your physician may request a blood test prior to the procedure to determine how long it takes your blood to clot. Other blood tests may be done as well.
  • You may receive a sedative prior to the procedure to help you relax. If a sedative is given, you will need someone to drive you home afterwards.
  • The upper chest may be shaved or clipped prior to the procedure.
  • Based upon your medical condition, your physician may request other specific preparation.

During the Procedure

Picture of a chest X-ray, showing a single-chamber implanted pacemaker
Chest X-ray with Implanted Pacemaker

A pacemaker or implanted cardioverter defibrillator may be performed on an outpatient basis or as part of your stay in a hospital. Procedures may vary depending on your condition and your physician’s practices.

Generally, a pacemaker or ICD insertion follows this process:

  1. You will be asked to remove any jewelry or other objects that may interfere with the procedure.
  2. You will be asked to remove your clothing and will be given a gown to wear.
  3. You will be asked to empty your bladder prior to the procedure.
  4. An intravenous (IV) line will be started in your hand or arm prior to the procedure for injection of medication and to administer IV fluids, if needed.
  5. You will be placed in a supine (on your back) position on the procedure table.
  6. You will be connected to an electrocardiogram (ECG or EKG) monitor that records the electrical activity of the heart and monitors the heart during the procedure using small, adhesive electrodes. Your vital signs (heart rate, blood pressure, breathing rate, and oxygenation level) will be monitored during the procedure.
  7. Large electrode pads will be placed on the front and back of the chest.
  8. You will receive a sedative medication in your IV before the procedure to help you relax. However, you will likely remain awake during the procedure.
  9. The pacemaker or ICD insertion site will be cleansed with antiseptic soap.
  10. Sterile towels and a sheet will be placed around this area.
  11. A local anesthetic will be injected into the skin at the insertion site.
  12. Once the anesthetic has taken effect, the physician will make a small incision at the insertion site.
  13. A sheath, or introducer, is inserted into a blood vessel, usually under the collarbone. The sheath is a plastic tube through which the pacer/ICD lead wire will be inserted into the blood vessel and advanced into the heart.
  14. It will be very important for you to remain still during the procedure so that the catheter placement will not be disturbed and to prevent damage to the insertion site.
  15. The lead wire will be inserted through the introducer into the blood vessel. The physician will advance the lead wire through the blood vessel into the heart.
  16. Once the lead wire is inside the heart, it will be tested to verify proper location and that it works. There may be one, two, or three lead wires inserted, depending on the type of device your physician has chosen for your condition. Fluoroscopy, (a special type of x-ray that will be displayed on a TV monitor), may be used to assist in testing the location of the leads.
  17. Once the lead wire has been tested, an incision will be made close to the location of the catheter insertion (just under the collarbone). You will receive local anesthetic medication before the incision is made.
  18. The pacemaker/ICD generator will be slipped under the skin through the incision after the lead wire is attached to the generator. Generally, the generator will be placed on the non-dominant side. (If you are right-handed, the device will be placed in your upper left chest. If you are left-handed, the device will be placed in your upper right chest).
  19. The ECG will be observed to ensure that the pacer is working correctly.
  20. The skin incision will be closed with sutures, adhesive strips, or a special glue.
  21. A sterile bandage/dressing will be applied.

After the Procedure

In the hospital

After the procedure, you may be taken to the recovery room for observation or returned to your hospital room. A nurse will monitor your vital signs for a specified period of time.

You should immediately inform your nurse if you feel any chest pain or tightness, or any other pain at the incision site.

After the specified period of bed rest has been completed, you may get out of bed. The nurse will assist you the first time you get up, and will check your blood pressure while you are lying in bed, sitting, and standing. You should move slowly when getting up from the bed to avoid any dizziness from the period of bedrest.

You will be able to eat or drink once you are completely awake.

The insertion site may be sore or painful, but pain medication may be administered if needed.

Your physician will visit with you in your room while you are recovering. The physician will give you specific instructions and answer any questions you may have.

Once your blood pressure, pulse, and breathing are stable and you are alert, you will be taken to your hospital room or discharged home.

If the procedure is performed on an outpatient basis, you may be allowed to leave after you have completed the recovery process. However, if there are concerns or problems with your ECG, you may stay in the hospital for an additional day (or longer) for monitoring of the ECG.

You should arrange to have someone drive you home from the hospital following your procedure.

At home

You should be able to return to your daily routine within a few days. Your physician will tell you if you will need to take more time in returning to your normal activities. In addition, you should not do any lifting or pulling on anything for a few weeks. You may be instructed not to lift your arms above your head for a period of time.

You will most likely be able to resume your usual diet, unless your physician instructs you differently.

It will be important to keep the insertion site clean and dry. Your physician will give you specific bathing instructions.

Your physician will give you specific instructions about driving. If you had an ICD, you will not be able to drive until your physician gives you approval. Your physician will explain these limitations to you, if they are applicable to your situation.

You will be given specific instructions about what to do if your ICD discharges a shock. For example, you may be instructed to dial 911 or go to the nearest emergency room in the event of a shock from the ICD.

Ask your physician when you will be able to return to work. The nature of your occupation, your overall health status, and your progress will determine how soon you may return to work.

Notify your physician to report any of the following:

  • fever and/or chills
  • increased pain, redness, swelling, or bleeding or other drainage from the insertion site
  • chest pain/pressure, nausea and/or vomiting, profuse sweating, dizziness and/or fainting
  • palpitations

Your physician may give you additional or alternate instructions after the procedure, depending on your particular situation.

Pacemaker/ICD precautions

The following precautions should always be considered. Discuss the following in detail with your physician, or call the company that made your device:

  • Always carry an ID card that states you are wearing a pacemaker or an ICD. In addition, you should wear a medical identification bracelet that states you have a pacemaker or ICD.
  • Use caution when going through airport security detectors. Check with your physician about the safety of going through such detectors with your type of pacemaker. In particular, you may need to avoid being screened by hand-held detector devices, as these devices may affect your pacemaker.
  • You may not have a magnetic resonance imaging (MRI) procedure. You should also avoid large magnetic fields.
  • Abstain from diathermy (the use of heat in physical therapy to treat muscles).
  • Turn off large motors, such as cars or boats, when working on them (they may temporarily €œconfuse” your device).
  • Avoid certain high-voltage or radar machinery, such as radio or television transmitters, electric arc welders, high-tension wires, radar installations, or smelting furnaces.
  • If you are having a surgical procedure performed by a surgeon or dentist, tell your surgeon or dentist that you have a pacemaker or ICD, so that electrocautery will not be used to control bleeding (the electrocautery device can change the pacemaker settings).
  • You may have to take antibiotic medication before any medically invasive procedure to prevent infections that may affect the pacemaker.
  • Always consult your physician if you have any questions concerning the use of certain equipment near your pacemaker.
  • When involved in a physical, recreational, or sporting activity, you should avoid receiving a blow to the skin over the pacemaker or ICD. A blow to the chest near the pacemaker or ICD can affect its functioning. If you do receive a blow to that area, see your physician.
  • Always consult your physician when you feel ill after an activity, or when you have questions about beginning a new activity.

SOURCE

http://stanfordhospital.org/healthLib/greystone/heartCenter/heartProcedures/pacemakerImplantableCardioverterDefibrillatorICDInsertion.html

In Summary: Who Needs a Pacemaker?

Doctors recommend pacemakers for many reasons. The most common reasons are bradycardia and heart block.

Bradycardia is a heartbeat that is slower than normal. Heart block is a disorder that occurs if an electrical signal is slowed or disrupted as it moves through the heart.

Heart block can happen as a result of aging, damage to the heart from a heart attack, or other conditions that disrupt the heart’s electrical activity. Some nerve and muscle disorders also can cause heart block, including muscular dystrophy.

Your doctor also may recommend a pacemaker if:

  • Aging or heart disease damages your sinus node’s ability to set the correct pace for your heartbeat. Such damage can cause slower than normal heartbeats or long pauses between heartbeats. The damage also can cause your heart to switch between slow and fast rhythms. This condition is called sick sinus syndrome.
  • You’ve had a medical procedure to treat an arrhythmia called atrial fibrillation. A pacemaker can help regulate your heartbeat after the procedure.
  • You need to take certain heart medicines, such as beta blockers. These medicines can slow your heartbeat too much.
  • You faint or have other symptoms of a slow heartbeat. For example, this may happen if the main artery in your neck that supplies your brain with blood is sensitive to pressure. Just quickly turning your neck can cause your heart to beat slower than normal. As a result, your brain might not get enough blood flow, causing you to feel faint or collapse.
  • You have heart muscle problems that cause electrical signals to travel too slowly through your heart muscle. Your pacemaker may provide cardiac resynchronization therapy (CRT) for this problem. CRT devices coordinate electrical signaling between the heart’s lower chambers.
  • You have long QT syndrome, which puts you at risk for dangerous arrhythmias.

Doctors also may recommend pacemakers for people who have certain types ofcongenital heart disease or for people who have had heart transplants. Children, teens, and adults can use pacemakers.

Before recommending a pacemaker, your doctor will consider any arrhythmia symptoms you have, such as dizziness, unexplained fainting, or shortness of breath. He or she also will consider whether you have a history of heart disease, what medicines you’re currently taking, and the results of heart tests.

Diagnostic Tests

Many tests are used to detect arrhythmias. You may have one or more of the following tests.

EKG (Electrocardiogram)

An EKG is a simple, painless test that detects and records the heart’s electrical activity. The test shows how fast your heart is beating and its rhythm (steady or irregular).

An EKG also records the strength and timing of electrical signals as they pass through your heart. The test can help diagnose bradycardia and heart block (the most common reasons for needing a pacemaker).

A standard EKG only records the heartbeat for a few seconds. It won’t detect arrhythmias that don’t happen during the test.

To diagnose heart rhythm problems that come and go, your doctor may have you wear a portable EKG monitor. The two most common types of portable EKGs are Holter and event monitors.

Holter and Event Monitors

A Holter monitor records the heart’s electrical activity for a full 24- or 48-hour period. You wear one while you do your normal daily activities. This allows the monitor to record your heart for a longer time than a standard EKG.

An event monitor is similar to a Holter monitor. You wear an event monitor while doing your normal activities. However, an event monitor only records your heart’s electrical activity at certain times while you’re wearing it.

For many event monitors, you push a button to start the monitor when you feel symptoms. Other event monitors start automatically when they sense abnormal heart rhythms.

You can wear an event monitor for weeks or until symptoms occur.

Echocardiography

Echocardiography (echo) uses sound waves to create a moving picture of your heart. The test shows the size and shape of your heart and how well your heart chambers and valves are working.

Echo also can show areas of poor blood flow to the heart, areas of heart muscle that aren’t contracting normally, and injury to the heart muscle caused by poor blood flow.

Electrophysiology Study

For this test, a thin, flexible wire is passed through a vein in your groin (upper thigh) or arm to your heart. The wire records the heart’s electrical signals.

Your doctor uses the wire to electrically stimulate your heart. This allows him or her to see how your heart’s electrical system responds. This test helps pinpoint where the heart’s electrical system is damaged.

Stress Test

Some heart problems are easier to diagnose when your heart is working hard and beating fast.

During stress testing, you exercise to make your heart work hard and beat fast while heart tests, such as an EKG or echo, are done. If you can’t exercise, you may be given medicine to raise your heart rate.

SOURCE

http://www.nhlbi.nih.gov/health/health-topics/topics/pace/whoneeds.html

What Are the Risks of Pacemaker Surgery?

Pacemaker surgery generally is safe. If problems do occur, they may include:

  • Swelling, bleeding, bruising, or infection in the area where the pacemaker was placed
  • Blood vessel or nerve damage
  • A collapsed lung
  • A bad reaction to the medicine used during the procedure

Talk with your doctor about the benefits and risks of pacemaker surgery.

How Does a Pacemaker Work?

A pacemaker consists of a battery, a computerized generator, and wires with sensors at their tips. (The sensors are called electrodes.) The battery powers the generator, and both are surrounded by a thin metal box. The wires connect the generator to the heart.

A pacemaker helps monitor and control your heartbeat. The electrodes detect your heart’s electrical activity and send data through the wires to the computer in the generator.

If your heart rhythm is abnormal, the computer will direct the generator to send electrical pulses to your heart. The pulses travel through the wires to reach your heart.

Newer pacemakers can monitor your blood temperature, breathing, and other factors. They also can adjust your heart rate to changes in your activity.

The pacemaker’s computer also records your heart’s electrical activity and heart rhythm. Your doctor will use these recordings to adjust your pacemaker so it works better for you.

Your doctor can program the pacemaker’s computer with an external device. He or she doesn’t have to use needles or have direct contact with the pacemaker.

Pacemakers have one to three wires that are each placed in different chambers of the heart.

  • The wires in a single-chamber pacemaker usually carry pulses from the generator to the right ventricle (the lower right chamber of your heart).
  • The wires in a dual-chamber pacemaker carry pulses from the generator to the right atrium (the upper right chamber of your heart) and the right ventricle. The pulses help coordinate the timing of these two chambers’ contractions.
  • The wires in a biventricular pacemaker carry pulses from the generator to an atrium and both ventricles. The pulses help coordinate electrical signaling between the two ventricles. This type of pacemaker also is called a cardiac resynchronization therapy (CRT) device.

Cross-Section of a Chest With a Pacemaker

The image shows a cross-section of a chest with a pacemaker. Figure A shows the location and general size of a double-lead, or dual-chamber, pacemaker in the upper chest. The wires with electrodes are inserted into the heart's right atrium and ventricle through a vein in the upper chest. Figure B shows an electrode electrically stimulating the heart muscle. Figure C shows the location and general size of a single-lead, or single-chamber, pacemaker in the upper chest.

The image shows a cross-section of a chest with a pacemaker. Figure A shows the location and general size of a double-lead, or dual-chamber, pacemaker in the upper chest. The wires with electrodes are inserted into the heart’s right atrium and ventricle through a vein in the upper chest. Figure B shows an electrode electrically stimulating the heart muscle. Figure C shows the location and general size of a single-lead, or single-chamber, pacemaker in the upper chest.

Types of Pacemaker Programming

The two main types of programming for pacemakers are

  • demand pacing and
  • rate-responsive pacing.

A demand pacemaker monitors your heart rhythm. It only sends electrical pulses to your heart if your heart is beating too slow or if it misses a beat.

A rate-responsive pacemaker will speed up or slow down your heart rate depending on how active you are. To do this, the device monitors your

  • sinus node rate,
  • breathing,
  • blood temperature, and
  • other factors to determine your activity level.

Your doctor will work with you to decide which type of pacemaker is best for you.

SOURCE

http://www.nhlbi.nih.gov/health/health-topics/topics/pace/howdoes.html

What To Expect During Pacemaker Surgery

Placing a pacemaker requires minor surgery. The surgery usually is done in a hospital or special heart treatment laboratory.

Before the surgery, an intravenous (IV) line will be inserted into one of your veins. You will receive medicine through the IV line to help you relax. The medicine also might make you sleepy.

Your doctor will numb the area where he or she will put the pacemaker so you don’t feel any pain. Your doctor also may give you antibiotics to prevent infection.

First, your doctor will insert a needle into a large vein, usually near the shoulder opposite your dominant hand. Your doctor will then use the needle to thread the pacemaker wires into the vein and to correctly place them in your heart.

An x-ray “movie” of the wires as they pass through your vein and into your heart will help your doctor place them. Once the wires are in place, your doctor will make a small cut into the skin of your chest or abdomen.

He or she will slip the pacemaker’s small metal box through the cut, place it just under your skin, and connect it to the wires that lead to your heart. The box contains the pacemaker’s battery and generator.

Once the pacemaker is in place, your doctor will test it to make sure it works properly. He or she will then sew up the cut. The entire surgery takes a few hours.

SOURCE

http://www.nhlbi.nih.gov/health/health-topics/topics/pace/during.html

What To Expect After Pacemaker Surgery

Expect to stay in the hospital overnight so your health care team can check your heartbeat and make sure your pacemaker is working well. You’ll likely have to arrange for a ride to and from the hospital because your doctor may not want you to drive yourself.

For a few days to weeks after surgery, you may have pain, swelling, or tenderness in the area where your pacemaker was placed. The pain usually is mild; over-the-counter medicines often can relieve it. Talk to your doctor before taking any pain medicines.

Your doctor may ask you to avoid vigorous activities and heavy lifting for about a month after pacemaker surgery. Most people return to their normal activities within a few days of having the surgery.

SOURCE

http://www.nhlbi.nih.gov/health/health-topics/topics/pace/after.html

How Will a Pacemaker Affect My Lifestyle?

Once you have a pacemaker, you have to avoid close or prolonged contact with electrical devices or devices that have strong magnetic fields. Devices that can interfere with a pacemaker include:

  • Cell phones and MP3 players (for example, iPods)
  • Household appliances, such as microwave ovens
  • High-tension wires
  • Metal detectors
  • Industrial welders
  • Electrical generators

These devices can disrupt the electrical signaling of your pacemaker and stop it from working properly. You may not be able to tell whether your pacemaker has been affected.

How likely a device is to disrupt your pacemaker depends on how long you’re exposed to it and how close it is to your pacemaker.

To be safe, some experts recommend not putting your cell phone or MP3 player in a shirt pocket over your pacemaker (if the devices are turned on).

You may want to hold your cell phone up to the ear that’s opposite the site where your pacemaker is implanted. If you strap your MP3 player to your arm while listening to it, put it on the arm that’s farther from your pacemaker.

You can still use household appliances, but avoid close and prolonged exposure, as it may interfere with your pacemaker.

You can walk through security system metal detectors at your normal pace. Security staff can check you with a metal detector wand as long as it isn’t held for too long over your pacemaker site. You should avoid sitting or standing close to a security system metal detector. Notify security staff if you have a pacemaker.

Also, stay at least 2 feet away from industrial welders and electrical generators.

Some medical procedures can disrupt your pacemaker. These procedures include:

  • Magnetic resonance imaging, or MRI
  • Shock-wave lithotripsy to get rid of kidney stones
  • Electrocauterization to stop bleeding during surgery

Let all of your doctors, dentists, and medical technicians know that you have a pacemaker. Your doctor can give you a card that states what kind of pacemaker you have. Carry this card in your wallet. You may want to wear a medical ID bracelet or necklace that states that you have a pacemaker.

Physical Activity

In most cases, having a pacemaker won’t limit you from doing sports and exercise, including strenuous activities.

You may need to avoid full-contact sports, such as football. Such contact could damage your pacemaker or shake loose the wires in your heart. Ask your doctor how much and what kinds of physical activity are safe for you.

Ongoing Care

Your doctor will want to check your pacemaker regularly (about every 3 months). Over time, a pacemaker can stop working properly because:

  • Its wires get dislodged or broken
  • Its battery gets weak or fails
  • Your heart disease progresses
  • Other devices have disrupted its electrical signaling

To check your pacemaker, your doctor may ask you to come in for an office visit several times a year. Some pacemaker functions can be checked remotely using a phone or the Internet.

Your doctor also may ask you to have an EKG (electrocardiogram) to check for changes in your heart’s electrical activity.

Battery Replacement

Pacemaker batteries last between 5 and 15 years (average 6 to 7 years), depending on how active the pacemaker is. Your doctor will replace the generator along with the battery before the battery starts to run down.

Replacing the generator and battery is less-involved surgery than the original surgery to implant the pacemaker. Your pacemaker wires also may need to be replaced eventually.

Your doctor can tell you whether your pacemaker or its wires need to be replaced when you see him or her for followup visits.

SOURCE

http://www.nhlbi.nih.gov/health/health-topics/topics/pace/lifestyle.html

Clinical Trial on Pace Makers

clinical trials related to pacemakers, talk with your doctor. You also can visit the following Web sites to learn more about clinical research and to search for clinical trials:

For more information about clinical trials for children, visit the NHLBI’s Children and Clinical Studies Web page.

SOURCE

http://www.nhlbi.nih.gov/health/health-topics/topics/pace/trials.html

RESOUCES on PaceMakers

Links to Other Information About Pacemakers

NHLBI Resources

Non-NHLBI Resources

Clinical Trials

SOURCE

 

Read Full Post »

Ultrasound in Radiology – Results of a European Survey

Reporter and Curator; Dror Nir, PhD

Ultrasound is by far, the most frequently used imaging modality in patient’s pathway being used by office-based clinicians and in most of hospitals’ departments. This is also true for cancer patients. As the contribution of imaging to the clinical assessment of patients becomes more substantial, the argument around “who is qualified” to perform such assessment is becoming louder and definitely more relevant!

Both the European and the North America Radiology societies are pushing towards establishment of centralized ultrasound services within the hospitals radiology department, still most ultrasound machines are spread between the different departments and being used by all practitioners. ESR’s working group on ultrasound published a report on the status of ultrasound-practice in European hospitals. Quite a shame; only 13% of the hospital addressed for participation in the survey reacted positively. I would like to highlight the most relevant conclusion from this survey, which is valid no matter which hand is holding the probe: Technique-oriented teaching, time and examinations are necessary to learn how to use Ultrasound properly within the framework of organ-oriented and disease training. Personally, I would support the idea that when it comes to management of cancer patients, this will become a “quality requirement” by law, similar to rules applicable to using radio-active substances.

 Here below is the full report:

Organisation and practice of radiological ultrasound in Europe: a survey by the ESR Working Group on Ultrasound

European Society of Radiology (ESR)1  

Neutorgasse 9/2, AT-1010 Vienna, Austria

European Society of Radiology (ESR)

Email: communications@myesr.org

URL: http://www.myESR.org

Received: 25 April 2013Accepted: 26 April 2013Published online: 29 May 2013

Abstract

Objectives

To gather information from radiological departments in Europe assessing the organisation and practice of radiological ultrasound and the diagnostic practice and training in ultrasound.

Methods

A survey containing 38 questions and divided into four groups was developed and made available online. The questionnaire was sent to over 1,000 heads of radiology departments in Europe.

Results

Of the 1,038 radiologists asked to participate in this survey, 123 responded. Excluding the 125 invitations to the survey that could not be delivered, the response rate was 13 %.

Conclusion

Although there was a low response rate, the results of this survey show that ultrasound still plays a major role in radiology departments in Europe: most departments have the technical capabilities to provide patients with up-to-date ultrasound examinations. Although having a centralised ultrasound laboratory seems to be the way forward, most ultrasound machines are spread between different departments. Ninety-one per cent of answers came from teaching hospitals reporting that training is regarded as an art and is needed in order to learn the basics of scanning techniques, after which working in an organ-oriented manner is the best way to learn how to integrate diagnostic US within the clinical context and with all other imaging techniques.

Main Messages

• Hospitals should introduce centralised ultrasound laboratories to allow for different competencies in US under the same roof, share human and technological resources and reduce the amount of equipment needed within the hospital.

• Technique-oriented teaching, time and examinations are necessary to learn how to use US properly within the framework of organ-oriented training.

• A time period of about 6 months dedicated solely to learning US scanning techniques is deemed sufficient in most cases.

INTRODUCTION

The Working Group on ultrasound (US) of the European Society of Radiology was founded in 2009 with the aim of supporting increased quality and visibility of US within radiological departments as well as strengthening the position of US within the radiology community.

Among the many practical goals assigned to the group, one of the most important has been to gather information about the organisation and practice of radiological US in Europe.

This article reports the results of a survey assessing how diagnostic US is practiced and how training in US is organised in radiological departments of European hospitals. Questions were also aimed at evaluating the practice of US within both radiology and other hospital departments in order to understand the relationships among the different users of this technique. A comparison with the results of a previous survey on the US activities within 17 academic radiological departments throughout Europe published in 1999 by Schnyder et al. [1] was also attempted.

MATERIALS AND METHODS

A questionnaire was developed to obtain data about the practice of diagnostic US within radiology departments in Europe.

The survey contained 38 questions that were divided into four groups:

(1)

Related to the hospital: location; dimensions; presence or absence of teaching duties.

(2)

Related to the workload of US: number of US examinations/year, amount of US equipment available; state of available technology; types of most frequent examinations; organisation of the US laboratory; presence of sonographers; methods of reporting and archiving US examinations.

(3)

Related to the teaching of US to radiology residents: organisation and duration of training programmes; number of examinations to be performed before completion of the training period; presence of training programmes dedicated to sonographers or other non-radiology residents.

(4)

Related to the US examinations performed outside radiology in each hospital; clinical specialists most often involved in performing directly US; availability of special techniques, such as contrast-enhanced ultrasound (CEUS); methods of reporting and archiving US examinations.

The questionnaire was made available online and an invitation to fill it in was sent to all 1,038 heads of radiology departments throughout Europe within the database of the European Society of Radiology. The invitation was repeated three times over a period of 3 months, between June and August 2011.

RESULTS

There were 123 responses to the questionnaire. Considering that 125/1,038 e-mail messages were reported as “undelivered”, the response rate to the invitation was 13 %. Many responders did not answer all the questions presented in the questionnaire, and some answers and comments were somewhat difficult to understand and evaluate.

First group of questions

Answers were gathered from different parts of Europe; 63.4 % were from five nations (Germany, Austria, France, Spain and Italy). The distribution according to countries is presented in Table 1.

Table 1

Nationality of responders

Germany (DE)

19

Austria (AT)

18

France (FR)

16

Spain (ES)

14

Italy (IT)

11

Hungary (HU)

7

Switzerland (CH)

5

The Netherlands (NL)

4

Turkey (TR)

3

UUK

3

Czech Rep (CZ)

3

Poland (PL)

2

Denmark (DK)

2

Romania (RO)

2

Norway (NO)

2

Croatia (HR)

2

Portugal (PT)

2

Belgium (BE)

2

Greece (GR)

1

Montenegro (ME)

1

Lithuania (LT)

1

Ireland (IE)

1

Serbia (RS)

1

Sweden (SE)

1

There were 25 responses (20.3 %) from hospitals with fewer than 400 beds, 52 (42.3 %) from hospitals with between 400 and 1,000 beds and 46 (37.4 %) from hospitals with more than 1,000 beds. Most answers were from teaching hospitals (91.1 %).

Second group of questions

Most radiology departments (77 %) have fewer than 10 working US units; 22 % have between 10 and 20 US machines; only 0.8 % have more than 20 machines. Small, portable units are available in 64.5 % of departments, 3D/4D capabilities are present in 52 % and elastography in 48.2 %, and 67.3 % have the possibility to perform CEUS examinations.

Up to 57.6 % of radiology departments perform more than 10,000 examinations per year; between 3,000 and 10,000 examinations per year are performed in 33.1 % of cases; only 9.3 % of departments perform fewer than 3,000 examinations.

Abdominal US is the most frequent exam (51.51 %), followed by breast (14.46 %), musculoskeletal (11.59 %), pelvic (10.88 %) and vascular (10.42 %) US examinations. Contrast-enhanced US (CEUS) studies constitute about 4.39 %. US is used by radiologists in emergency in 96.6 % of cases and in paediatrics in 74.6 %. Comments indicate that most of those who answered “no” did not have a paediatric section in their hospital.

Transvaginal US is used in obstetric examinations by 15.8 % of responders and in gynaecological studies by 50.7 %. Endoscopic US is used by radiologists in 13.4 % and intravascular US in 14.6 %; radiologists are called by surgeons for intraoperative US in 64.2 % of cases.

There were 49 responders who indicated the actual number of US examinations performed/year. The characteristics of hospitals in which the radiology department performs more than 20,000 ultrasound examinations/year are presented in Table 2.

Table 2

Characteristics of the hospitals in which the radiology department performs more than 20,000 US examinations/year (nationality, presence/absence of teaching duties, number of inpatients, number of US machines available, ratio between number of US examinations performed by non-radiology specialists vs. radiologists)

t2

Those who reported fewer than 5,000 US examinations/year are reported in Table 3.

Table 3

Characteristics of the hospitals in which the radiology department performs less than 5,000 US examinations/year (nationality, presence/absence of teaching duties, number of inpatients, number of US machines available, ratio between number of US examinations performed by non-radiology specialists vs. radiologists)

t3

Third group of questions

The first question in this group was whether the hospital was organised with a centralised US laboratory where physicians from all specialties work together.

There were 13/110 positive answers (11.8 %) from Germany (5), Spain (3), Austria (2), Hungary (2) and Croatia (1). All other hospitals have US machines scattered throughout the different radiological and non-radiological departments. The centralised US laboratory is organised together by the radiology and the internal medicine departments in three cases; it is truly multidisciplinary, with all specialties concurring, in three others; it is run by radiology in two. The remaining two positive answers did not provide further detail about their organisation.

The second question related to the role of sonographers. Only 15/110 (13.6 %) department heads stated they work with sonographers. They are located in Spain (3), Germany (2), UK (2), The Netherlands (2), Austria (1), Belgium (1), Ireland (1), Lithuania (1) and Montenegro (1). In all others, US examinations are done directly by the radiologists. There were 12 comments describing how the work of sonographers is organised. Sonographers do both the examination and the report, with the radiologist checking difficult cases only in four hospitals; sonographers do the studies and the radiologist takes a final look and writes the reports in six; two departments state they use sonographers for vascular examinations only.

The third question related to the organisation of training programmes in US. Radiology residents are trained in 91.1 % of responders. Some centres organise a theoretical course on basic principles of US before starting practical activity. Then, clinical practice is usually performed according to organ/systems training schemes. Residents work under close supervision of a senior radiologist: they approach the patient, perform a preliminary examination and issue a first report, which is then checked by the expert. The aim is to obtain progressive growth of competences: from scanning capabilities, to reporting capabilities, to complete independence.

The length of the period of training within the US laboratory in the various teaching hospitals and the minimum number of US examinations required before the end of the residency period are summarised in Tables 4 and5.

Table 4

Length of the period of training within the US laboratory in the 84 teaching hospitals that reported it

No. of teaching hospitals

Length of training

13

<4 months

38

4–6 months

26

6–12 months

7

>1 year

Table 5

Minimum number of US examinations to be performed before the end of the residency period in the 75 teaching hospitals that reported it

No. of teaching hospitals

Minimum no. of US examination

20

<500

16

500–1,000

17

1,000–2,000

22

>2,000

There was a direct correlation between the number of US exams performed in the department and the depth of US involvement during training: training programmes in the two hospitals where the lowest number of US examinations/year is performed indicate a period of 3 months and 250 and 500 examinations. However, a hospital with a workload of 45,000 US studies per year (in which, however, the examinations are performed by sonographers) suggested only 2–3 months of training and 100 exams before the end of the residency period.

Training is also provided for non-radiology residents in 37 hospitals. It is most frequently offered to internal medicine, gastroenterology, surgery, anesthesiology, vascular surgery and paediatrics. Comments indicate that these radiology courses allow only theoretical teaching, since observation, but not direct contact with patient, is provided for non-radiologists.

All 15 departments working with sonographers provide, or are planning to provide, starting in 2012, training courses for these professionals. These include both theory and practice; the theoretical part is done, in some cases, together with radiology residents.

As an important technical point, it must be noted that US images performed by radiologists are recorded into PACS systems in 85.6 % of cases. Comments on this question indicated that not all equipment is linked to PACS and that only selected images or videos are often archived; furthermore, technical problems in archiving videos have been reported.

A final group of questions pertained to the US examinations performed outside the radiology department in each hospital.

One question asked about the proportion of US examinations performed by radiologists vs. those performed by non-radiologists. European radiologists, as a whole, still perform a higher number of examinations (61.27 %) than non-radiologists (38.32 %). Differences in the percentage of studies performed in the different hospitals are presented in Table 6.

Table 6

Proportion of US examinations performed by radiologists vs. non-radiologists. Although radiologists, as a whole, perform more US examinations than non-radiologists, the table shows there are differences among different departments, with slightly more than 50 % performing more than 70 % of the studies

% of hospital US exams performed by radiologists

No. of radiology departments

≥90 %

25 (20.32 %)

70–90 %

37 (30.08 %)

10–70 %

57 (46.35 %)

<10 %

4 (3.25 %)

Comments indicate that most OB/GYN, neurology, vascular, urology, internal medicine, anaesthesiology and gastroenterology departments run their own US units in their wards. CEUS is used in 35.1 % of gastroenterology departments, in 15.1 % of internal medicine, in 10.6 % of transplant units and in 10.4 % of nephrology departments.

The examinations performed out of the radiology department are formally reported in 64.4 % of cases only. Comments indicate that reports are fully stored within the Hospital Information System (HIS) in 31 cases; storage is only partial in 24; no HIS storage is used in 5 cases.

US images obtained outside of the radiology department are recorded into the PACS system of the hospital in 18.3 % of cases only.

DISCUSSION

Several considerations are raised from the results of this survey.

First, there was a low response rate to the survey itself. There were only 123 answers to the 913 received messages asking for information from radiology department heads (a mere 13 %). It is hoped that this low response rate relates to the many committments on their side and not to low interest in the role of US within radiology [2, 3].

Second, most responders indicated that US is still an important part of the activities of the radiology department. Only 9.3 % report fewer than 3,000 examinations/year. It must be noted that there may be a bias in these figures, since it is conceivable that responders were more interested in US than those who did not answer the questionnaire (even if there were responders who indicated that, in their hospital, US is done mostly outside of the radiology department). Most of the workload is due to abdomino-pelvic exams, followed by breast, musculoskeletal and vascular applications. Furthermore, state-of-the-art equipment is used in about 50 % and CEUS can be performed in 64.2 %. Portable machines are available in 64.5 %, transvaginal US examinations of the pelvis are used in 50.7 %, and radiologists are still involved in intraoperative US examinations in 64.2 % of cases. Most departments still have the technical capabilities to provide up-to-date US answers to the requests they receive.

Another consideration relates to the organisation of US within the hospital. In most cases US machines are scattered throughout the different departments, and only 13 hospitals have organised a centralised US laboratory where all physicians from different specialities come to examine their patients. Although centralisation seems the best way to run a US service, there are several factors that can explain why this is not the case, many of which stem from tradition. US laboratories, in fact, commonly arose separately from one another, following the initiatives of the different specialists who started introducing this technique in their practice. Then, there is a disposition to maintain independence and separate departmental income from the activities as well as the desire to control all aspects of patients’ care.

Only 15 departments reported they are working with sonographers. Although it is known that in Europe most radiologists perform US examinations directly, it is believed that this figure underestimates the real contribution of these professionals. A possible explanation is that only three hospitals from the UK answered the questionnaire; in the UK sonographers play a major role in dealing with the US workload.

Most answers to the questionnaire came from teaching hospitals (91.1 %). Comments on how training is organised state that US scanning is commonly regarded as an art, taught from maestro to pupil, with progressive growth in scanning and reporting capabilities. In addition, most report that US is taught within an organ-/system-oriented training system. The “art” of US is highly dependent on the operator’s dedication and technical ability, and this has to be properly taught. Additionally, a period of training within a dedicated US laboratory is probably needed to learn the basics of scanning techniques. After learning the technique, working in an organ-oriented manner is surely the best way to learn how to integrate diagnostic US within the clinical context and with all other imaging techniques.

There were 13 teaching hospitals in which fewer than 4 months is deemed sufficient, and in 20 cases having fewer than 500 examinations before the end of the residency is regarded as complete training.

The low number of US examinations performed in some training centres can jeopardise teaching. The recruitment of patients for adequate training can be impossibile to obtain in low-volume practices, leading to a further decrease of radiological US for future generations of radiologists. Furthermore, the use of sonographers can make teaching the practical skills of US scanning difficult. In a hospital with high-volume US practice (45,000 cases/year) in which the examinations are performed by sonographers, residents are asked to remain in the US laboratory only for 2–3 months and to perform only 100 examinations before the end of training. When in clinical practice in a hospital without sonographers, these radiologists would not be able to carry out even routine diagnostic US examinations. On the contrary, the role of expert sonographers as a resource to provide practical training to radiology residents has not been considered and can be explored.

The results of this survey show a large heterogeneity in the use of US within radiology throughout Europe. There are hospitals in which the majority of US examinations are still performed by radiologists, and others in which radiologists are left with only a small proportions of studies.

Similar findings were observed by Schnyder et al. in 1999 [1]. From their survey in 17 academic radiology departments throughout Europe, these authors reported that in some nations radiologists had full control of US, while this was not the case in Germany, Austria and Switzerland. The situation seems somewhat worse today, since there are 22 hospitals (18.2 %) in different nations (Austria, Poland, Germany, France, UK, Norway, Switzerland and Italy) in which radiologists perform less than 70 % of all US examinations and 5 (4 %) who answered they do less than 10 % of the studies. Since the answers to the questionnaire were provided by radiology departments, the figures for radiological activity can be considered as precise. On the contrary, it is possible that those answers on the US activities out of radiology can be regarded as an estimate. However, to the best of our knowledge, the data in the survey of Schnyder et al. were also obtained in a similar way, and a comparison can thus be made.

The percent decrease in the number of US examinations done in radiology vs. those performed outside radiology is probably related to a marked increase of the use of US by non-radiology clinicians rather than to a decreased attention to this technique by radiologists. In fact, new specialists, such as emergency physicians and anesthesiologists, are now using this technique as a complement to their visit or as a guide to therapeutic manoeuvres, and the so-called “point-of-care US” philosophy, in which US equipment accompanies the physician at the patient’s bedside to guide his/her therapeutic decision making, is gaining popularity.

An additional point to be considered relates to the recording of US reports and images into the hospital informations system and PACS. US examinations performed by radiologists are archived within the PACS system in 85.6 %, while those performed by non-radiologists are stored in only 18.3 % of cases. Furthermore, radiologists provide a formal report in virtually all cases, while examinations performed out of radiology are formally reported in 64.4 %. Costs and technical difficulties in connecting all equipment to PACS and RIS are described as reasons for not recording US images, and this is especially the case for recording of video clips. The use of “point-of-care US” is a further difficulty for connecting equipment to PACS, and, within this framework, the US exam is not regarded as a separate study but as part of the physician visit. However, to have all US images and reports of the patient recorded and available for consultation could greatly help during subsequent studies, and efforts have to be made to develop consensus with clinical colleagues to increase connectivity and to report all US studies, at least as a description within the patients’ charts. Within the framework of the relationships established by the ESR WG in US with the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB), it has been agreed to prepare and publish a recommendation about the necessity, for all US examinations, of a formal report and proper archiving of both report and images.

ACTION POINTS

Two points of action can be suggested.

The first relates to the centralisation of the US laboratory. Although at the moment only a small number of hospitals are working according to this model, radiologists should take the lead in proposing such organisation [4]. This would allow the gathering of all the different competencies in US under the same roof, to share human and technological resources and to reduce the amount of equipment needed within the hospital. In an era of cost containments, a centralised US laboratory can allow each US scanner operate for longer hours and with higher numbers of examinations, resulting in an optimisation of resources. Furthermore, requests to upgrade and/or renovate equipment would possibly be easier if coming from a large laboratory and shared by different hospital departments. Another advantage would be having people with different backgrounds work in the same environment, thus promoting exchange and integration of their knowledge and possibly resulting in better patient care. It would be easier, in this respect, to prepare institutional guidelines and protocols that place US in the correct perspective towards all other imaging modalities and, most importantly, towards patients’ needs. It is not clear from the survey how this way of working is organised on a day-to-day basis, and especially how emergency services are provided (i.e. if all specialists concur in the emergency or if this is left to radiologists only), but an integrated management and organisational infrastructure bears numerous advantages for cost containment, quality standards and efficiency.

The second point of action relates to training in US within radiology residency programmes. In the opinion of the ESR Working Group on US, radiologists need to develop consensus on how many examinations under tutorship residents have to perform and on how much time they have to spend in ultrasound before the end of the training period. The results of the survey vary widely. However, out of 75 training centres that reported on the number of examinations, there were 39 (52 %) providing figures between 1,000 and 2,000 or higher. Therefore, approximately 2,000 seems to be a figure on which consensus can be reached. This figure also complies with what is suggested by the EFSUMB [5]. This federation provides recommendations about the number of examinations for training in the different subspeciality areas of US: the sum of studies for abdomen, breast, musculoskeletal and vascular training is 1,500, while figures for head and neck are not provided. The length of training is more complex to decide. A distinction has to be made here between the time needed to learn the technique of US scanning and the time needed to learn how to use US properly, to integrate it with other imaging techniques and to provide useful reports. In order to perform US, both approaches are needed. Technique-oriented teaching is necessary to learn how to perform the studies and to identify anatomy and pathology. Time and exams are needed to learn how to use US properly within the framework of organ-oriented training. A period of time of about 6 months dedicated solely to learning the US scanning technique can possibly be considered sufficient, as suggested by 76.2 % of responders. The capabilities of residents to perform US examinations have to be assessed during the training period, especially during and at the end of the technique-oriented part. It is known that the learning curve can vary widely among trainees, and longer times and higher numbers of examinations may be needed in some cases [6]. Additional time should be spent, and exams taken, during organ-oriented training. It must be underlined that organ-oriented teaching needs to include the proper role of US in each subspeciality and also take into account technical advances such as CEUS, 3D/4D and elastography and to use them when needed.

Acknowledgment

This article was kindly prepared by the ESR Working Group on US (M. Bachmann-Nielsen, M. Claudon, L. E. Derchi, S. Elliott, G. Mostbeck, C. Nicolau, S. Yarmenitis, A. Zubarev, Y. Menu–Chair of the ESR Professional Organisation Committee and J.A. Reekers–Chair of the ESR Subspecialty Societies Committee) on behalf of the European Society of Radiology. It was approved by the ESR Executive Council in April 2013.

Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.

References

1.

Schnyder P, Capasso P, Meuwly I-Y (1999) Turf battles in radiology: how to avoid/how to fight/how to win. Eur Radiol 9:741–748PubMedCrossRef

2.

Lockhart ME (2008) The role of radiology in the future of sonography. AJR 190:841–842PubMedCrossRef

3.

Derchi LE, Claudon M (2009) Ultrasound: a strategic issue for radiology? Eur Radiol 19:1–6PubMedCrossRef

4.

Krestin GP (2009) Maintaining identity in a changing environment: the professional and organizational future of radiology. Radiology 250:612–617PubMedCrossRef

5.

Minimum training recommendations for the practice of medical ultrasond in Europe. http://www.org/guidelines/guidelines01.asp

6.

Hertzberg BS, Kliewer MA, Bowie JD, Carroll BA, DeLong DH, Gray L, Nelson RC (2000) Physician training requirements in sonography: how many cases are needed for competence? AJR 174:1221–1227PubMedCrossRef

Read Full Post »

3D Cardiovascular Theater – Hybrid Cath Lab/OR Suite, Hybrid Surgery, Complications Post PCI and Repeat Sternotomy

Curator: Aviva Lev-Ari, PhD, RN

Article ID #70: Cardiovascular Original Research: Cases in Methodology Design for Content Curation and Co-Curation. Published on 7/19/2013

WordCloud Image Produced by Adam Tubman

This article has THREE Parts: 

Part One:  Hybrid Cath Lab/OR Suite for Hybrid Surgery

Part Two: Cardiac Surgery 

Part Three: Invasive Interventions with Complications

1. Repeat Sternotomy Post CABG and/or Aortic Valve Replacement

2. Complications Post PCI – Pump Catheter in Use

The voice of Series A Content Consultant, Justin D Pearlman, MD, PhD, FACC

The leading cause of death and disability from any cause is cardiovascular disease, principally, heart attacks and strokes. Both the heart and brain typically allow only 10 minutes or so of inadequate blood supply before starting a committed course of permanent tissue injury, progressing in severity as time goes by without successful interruption of the disease process. Thus there is great time urgency to get patients to a definitive treatment that can stop the injury and restore adequate nutrient blood supply. Many patients can benefit from a catheterization to identify blockages and insert a small balloon within the blockage to expand the narrow channel, often followed by placement of a stent (wire cage) to maintain the expanded vessel diameter. Chemicals released over time from drug-eluting stents can prevent tissue in growth that may obstruct stents. These emergeny interventions are not always successful. There may be complications from the attempt to access an entry artery, and the blockages may not be amenable to a balloon. When such limitations are encountered, the next chance to help is surgical, with continued time pressure.

The fastest way to make the transition from a diagnostic catheterization to a timely intervention is a hybrid intervention suite that offers non-invasive imaging, catheterization and surgery all in one location. The following articles present the current state of hybrid “do it all” intervention suites. Additional articles address the risks of bad outcomes from such interventions.

Part One 

Hybrid Cath Lab/OR Suite for Hybrid Surgery

In ACC.10 and i2 Summit, 59th Annual Scientific Session, 3/14-3/16, 2010, Alfred A. Bove, M.D., Ph.D., F.A.C.C., ACC President addressed the conference attendees:

Welcome to the all-new Hybrid Cath Lab/OR and 3D CV Theater. Recent developments in cardiac surgery and interventional cardiology have led to the creation of integrated, hybrid cath lab/operating rooms (OR), which provide significant advantages in the diagnosis and treatment of patients requiring cardiac procedures—helping to facilitate a rapid-response approach. These multimodality rooms are designed to support a variety of integrated surgical and endovascular procedures. We are excited to provide you with this opportunity to get a first-hand look—and feel—of the latest technologies. We hope you take the time to explore this interactive, multivendor venue. Learning is at the core of the ACC Annual Scientific Session and we invite you to expand your educational experience in this dynamic learning environment.

In the Hybrid Cath Lab/OR Suite, you’ll discover how integrating cutting edge angiographic and surgical equipment and technologies can facilitate a broad range of procedures within one location. Additionally, you will learn how hybrid suites are providing solutions that enable interventionalists and surgeons to work collaboratively to provide the best treatment options for patients. The adjoining 3D CV Theater features presentations by physicians currently performing intravascular and surgical procedures in hybrid suites. Each live presentation pairs a cardiologist with a surgeon, allowing you to hear perspectives from both sides on a variety of hybrid suite procedures and cases. In addition, the Theater offers video presentations of cases from around the world.

The ACC thanks the supporters of the Hybrid Suite for providing us with the opportunity to share this unique learning destination with you.

http://www.expo.acc.org/acc12/CUSTOM/images/ACC12/ACC.10%20Hybrid%20Suite%20Directory.pdf

Hybrid Cath Lab/OR Suite for Hybrid Surgery

Procedures Performed in a Hybrid Suite

The treatment of cardiovascular diseases has undergone a paradigm shift within the last few years, from

  • open surgery to minimally invasive surgical procedures and from
  • limited percutaneous catheter-based interventions to hybrid interventions for the entire cardiovascular tree.

The Hybrid Suite

are perfect examples of procedures that could, and should, be carried out in a hybrid OR. High-risk patients who require less invasive interventions are the best candidates for treatment in a hybrid suite.

As cardiac surgery becomes less invasive, incisions are becoming smaller and smaller, and even totally endoscopic heart surgery is now possible. Cardiac surgeons have started to perform procedures that include catheter-based skills, such as transapical valve replacement. For these operations, surgeons need more sophisticated imaging techniques, fluoroscopy and contrast injections. The hybrid OR offers all these facilities. Perhaps the most obvious and easiest procedure that can be performed in a hybrid OR is coronary revascularization combining coronary artery bypass grafting with on-table intra-operative completion angiography for quality control. If the surgeon detects a problem during the procedure, he or she can revise the graft immediately and thereby prevent potential perioperative and long-term complications. Currently, cardiologists and cardiovascular surgeons have shown special interest in so-called hybrid coronary interventions, which are combinations of minimally invasive coronary artery bypass grafting and percutaneous coronary interventions. In these procedures, cardiovascular surgeons place a left-internal mammary artery bypass graft to the left-anterior descending artery through small incisions (MIDCAB) or completely endoscopically (TECAB), while any remaining obstructed coronary arteries are treated with stents by an interventional cardiologist. This procedure is an attractive alternative to multivessel open coronary artery bypass grafting. Transcatheter heart-valve replacement and repair are especially suited to a hybrid suite because percutaneous transfemoral and transapical aortic valve repairs include risks that can only be treated successfully by immediate surgical intervention, such as coronary artery obstruction, aortic dissection and aortic perforations.

In addition, endovascular aortic stent grafting for the repair of abdominal aortic aneurysms is a suitable procedure for a hybrid operating room. Endovascular aneurysm repair has become an established alternative to open repair and is increasingly used for thoracic aorta repair as well. Some

  • emergency procedures for traumatic lesions of the thoracic aorta and
  • fulminant pulmonary embolism may also be performed in a hybrid OR. Several
  • pediatric interventions can be carried out in a hybrid suite as well, such as implantation of closure devices for atrial and ventricular septal defects in small children and
  • treatments for hypoplastic left-heart syndrome.

http://www.expo.acc.org/acc12/CUSTOM/images/ACC12/ACC.10%20Hybrid%20Suite%20Directory.pdf

In a recent article we reported on the Change in Requirement for Surgical Support by Cath Labs for performance of Nonemergent PCI without Surgical Backup, that increases the autonomy of Interventional Cardiologists. In the Hybrid OR that change is irrelevant since the presence of a Cardiac Surgeon is a fact of the division of labor between the two types of specialties. Cardiac Surgeons are involved with  percutaneous transfemoral and transapical aortic valve repairs and intervention for endoscopic aorta, AAA and Thoracic AA grafting.

AHA, ACC Change in Requirement for Surgical Support:  Class IIb -> Class III, Level of Evidence A: Supports Nonemergent PCI without Surgical Backup (Change of class IIb, level of Evidence B).

What is a Cardiovascular Hybrid Suite?

Cardiovascular hybrid suite is a state-of-the-art operating room equipped with a fully functional catheterization laboratory, thus allowing surgical procedures and catheter-based interventions to be carried out in the same room. Hybrid suites provide a place where treatments traditionally available only in a cath lab and procedures only available in an operating room can be performed together to provide patients with the best available combination of therapies for cardiovascular disease. These multidisciplinary, integrated cardiovascular procedural suites bring the best of two worlds together by combining all the advantages of a modern cath lab with an up-to-date cardiovascular surgery operating room (OR).

Hybrid suites began to evolve in the mid to late 1990s, when some groups of interventional cardiologists started sharing operating rooms with cardiovascular surgeons. The appeal of the hybrid suite concept has grown as have catheter based devices (stents, coils, balloons and lasers) have been developed that enable interventional cardiologists to advance the invasiveness and effectiveness and applications of percutaneous transcatheter interventions. The interest in these suites has also increased as cardiovascular surgeons have developed a variety of techniques for

  • Minimally invasive procedures, such as minimally invasive direct coronary artery bypass grafting (MIDCAB) or
  • Totally endoscopic coronary artery bypass grafting (TECAB).

With the advent of more tools, interventional cardiologists are becoming more like surgeons, and with less invasive tools, cardiovascular surgeons are becoming more like interventionalists. Rather than separating surgical procedures from interventional procedures performed in traditional operating rooms and cath labs, hybrid suites provide a high-tech environment that allows cardiologists and surgeons to work together to offer patients complex, minimally invasive therapies.

Some experts believe that hybrid suites represent the wave of the future in cardiovascular care and that most heart centers will eventually install hybrid suites to offer patients the latest cardiovascular procedures safely and effectively with minimal surgical trauma. The rooms can be costly to build and equip, but if a medical center is considering building a new operating room or cath lab, setting up a hybrid suite makes sense. Medical centers that have a hybrid suite available can clearly differentiate themselves in a positive way from centers that do not have such capabilities.

The Benefits of a Hybrid Suite for Medical Centers

While building a hybrid suite is more expensive than building a traditional operating room or cath lab, a hybrid suite can potentially be used for all types of cardiovascular procedures, including

  • traditional cardiac and vascular surgery,
  • interventional coronary procedures,
  • endovascular aortic procedures and
  • electrophysiology procedures.

Hybrid suites reinforce the trend in cardiovascular care toward less invasive, comprehensive hybrid procedures. Once a hybrid suite is in place, the demand for its use will likely grow due to increasing indications and referrals for these innovative treatments, many of which are increasingly covered by third-party payers.

http://www.expo.acc.org/acc12/CUSTOM/images/ACC12/ACC.10%20Hybrid%20Suite%20Directory.pdf

What Equipment is Needed?

Interventional cath labs usually have excellent imaging capabilities but lack the sterile facilities and staff needed for a formal OR, while operating rooms frequently lack high-level imaging equipment. Some of the essential equipment for a hybrid suite includes:

• A state-of-the-art imaging system capable of performing 3D rotational angiography, CT scanning, and ultrasound is advantageous. Floor-mounted and ceiling-mounted systems are available, but many hospitals use ceiling-mounted systems because access to the patient is slightly easier. Some ceiling-mounted systems provide 3D imaging from the surgeon’s position perpendicular to the patient. However, some hospitals prefer floor-mounted systems because having mechanical parts running above the operative field may cause dust to fall, resulting in infections. An important aspect is that the C-arm can be parked away when it is not used. This especially enhances access of the anesthesia team to the patient.

• An operating table that meets the needs of both surgeons and interventionalists by electronically integrating the table with the imaging system is also essential. These tables should have retractable rails for retractors and other surgical tools. To perform 3D imaging on the operating table, the C-arm of the imaging system should allow fast and precise rotation around the patient.

• A variety of other surgical and interventional systems and equipment may also be needed, including a robotic surgical system, a heart-lung machine, an image integration system, an endoscopic imaging system, a radiology display system, an audiovisual system to move images to different monitors and an anesthesia monitoring system, including transesophageal echocardiography. Some equipment like the integrated OR table and the angiography unit need to be fixed parts of the hybrid OR. Some equipment will be mobile in order to maintain some flexibility in workflow.

Hybrid1

Hybrid2

Hybrid3

Hybrid4

Hybrid5

Who are the Equipment Vendors?

Philips Healthcare

Phone: 800-934-7372

Email: healthcare@philips.com

Web: http://www.philips.com/healthcare

Philips is one of the world’s leading technology companies, with a long history of practical innovation and visionary design. In healthcare, we are committed to understanding the human and technological needs of patients and caregivers. We believe this understanding will help us deliver solutions that not only enable more confident diagnoses and more efficient delivery of care, but also improve the overall experience of care. We offer equipment, software and services for imaging, patient monitoring, resuscitation and much more.  A Hybrid OR can help make life simpler for the interdisciplinary teams who operate in this environment every day. As a world leader in cardiovascular X-ray, Philips has the experience and expertise to deliver the first class technology you need to perform minimally invasive procedures with speed, accuracy and confidence. A long history of innovation has enabled Philips to develop pioneering imaging solutions that really make a difference.

For example, Philips Allura Xper cardiovascular X-ray systems are designed to deliver enhanced imaging with superb performance for all cardiac projections, and our iE33 ultrasound system with Live 3D TEE and QLAB can assist interventional procedures and provide comprehensive quantitative information to support critical decisions. Our cardiology informatics solutions help you manage patient information throughout the cardiovascular care continuum. Philips solutions allow minimally invasive and catheter-based procedures to take place in the same suite as conventional cardiac surgery.

Phillips EchoNavigator – X-Ray and 3-D Ultrasound is described in:

Minimally Invasive Structural CVD Repairs: FDA grants 510(k) Clearance to Philips’ EchoNavigator – X-ray and 3-D Ultrasound Image Fused.

Intuitive Surgical, Inc. 

da Vinci.Surgery by Intuitive Surgical, Inc. 

Phone: 800-876-1310

Email: info@intusurg.com

Web: http://www.intuitivesurgical.com

Intuitive Surgical, Inc. is the global technology leader in robotic-assisted, minimally invasive surgery. The company’s da Vinci® Surgical System offers breakthrough capabilities that enable cardiac surgeons to use a minimally invasive approach and avoid median sternotomy.

Content of FDA Warning Letter, following  FDA Inspection on dates 04/01/2013 – 05/30/2013 – it discussed in

Hybrid Cath Lab/OR Suite’s da Vinci Surgical Robot of Intuitive Surgical gets FDA Warning Letter on Robot Track Record

 

MAVIG GmbH 

Phone: 631-266-2229,

585-247-1212 ext. 60

Email: info@mavig.com

Web: http://www.mavig.com

MAVIG’s specialty is ceiling/boom suspension systems for lighting (exam, surgical and LED), monitor-suspension systems—single, multibank (one to eight) systems and widescreen, overhead radiation shielding and contrast injector adapters. MAVIG also manufactures radiation protection products such as aprons, gloves, table-attachable lower body shields, adjustable- and fixed-height mobile and modular barriers.

Toshiba America Medical Systems, Inc.

Phone: 714-730-5000

Email: mktgcomm@tams.com

Web: http://www.medical.toshiba.com

Creating a hybrid lab may be complicated, but having an experienced partner that listens makes all the difference. Toshiba’s unique blend of hybrid experience and industry recognized Infinix™-i imaging systems for the Cath Lab.

Hybrid Cath Lab/OR Suite in Leading Hospitals in the US

  • The  Hybrid Cath Lab/OR Suite at New York Presbyterian Hospital/Columbia University Medical Center, New York, NY is presented in

Becoming a Cardiothoracic Surgeon: An Emerging Profile in the Surgery Theater and through Scientific Publications

  • The  Hybrid Cath Lab/OR Suite at Cleveland Clinic, Cleveland, Ohio is presented in

Heart Transplant (HT) Indication for Heart Failure (HF): Procedure Outcomes and Research on HF, HT @ Two Nation’s Leading HF & HT Centers

Speakers at 3D CV Theater, 2010 are working in Hospitals where Hybrid Cath Lab/OR Suite are in operations at the present time. The list include the following Hospitals with a Hybrid Cath Lab/OR Suite:

  • Vanderbilt Medical Center, Nashville, TN
  • University of Maryland Heart Center, Baltimore, MD
  • The Heart Center at Nationwide Children’s Hospital, Columbus, Ohio
  • The Robotic Surgical Center, East Carolina University Department of Surgery, Greenville, N.C.
  • University of Washington Medicine Regional Heart Center, Seattle, WA
  • Brigham and Women’s Hospital, Boston, MA
  • Saint Joseph’s Hospital and Peachtree Cardiovascular and Thoracic Surgery, Atlanta, GA
  • Emory University Hospital, Atlanta, GA
  • Beth Israel Deaconess Medical Center, Boston, MA
  • Boston Medical Center, Boston, MA
  • Mayo Graduate School of Medicine, Mayo Clinic, Rochester, MN
  • Lankenau Hospital, Lancaster, PA
  • Cardiac Non-Invasive Laboratory at Cedars-Sinai Medical Center, Los Angeles, CA
  • Robotic Surgery at St. Joseph’s Hospital, Atlanta, GA

Speakers at 3D CV Theater, 2010, included the following Cardiovascular Interventionists leading the adoption process of Hybrid Surgery in Hybrid Cath Lab/OR Suite into care modalities for cardiovascular disease:

Johannes O. Bonatti, M.D., is professor of surgery and director of coronary surgery and advanced coronary interventions at the University of Maryland Heart Center, Baltimore. He received his training in general surgery and cardiac surgery at the department of surgery at Innsbruck Medical University in Austria. Prior to his arrival at the University of Maryland, he worked at this institution as an attending surgeon and associate professor. Dr. Bonatti’s main interest is the development of minimally invasive, totally endoscopic coronary artery bypass grafting (TECAB) procedures using robotic technology.

As one of the international leaders in this field, he performed the largest series of robotic TECAB on the arrested heart, including single-, double- and triple-vessel TECAB. He has published significantly on procedure development and the implementation process of completely endoscopic coronary surgery using the da Vinci robotic system. Together with colleagues from interventional cardiology, Dr. Bonatti is working on integrated concepts for treatment of coronary artery disease. He was the first to perform a simultaneous hybrid coronary intervention using TECAB and placement of a coronary stent. He is organizing international meetings on hybrid interventions in cardiovascular medicine (http://www.icrworkshop.com). He has trained heart surgeons from around the world in the use of the da Vinci robot for heart surgery and he has introduced TECAB procedures in Austria, the Czech Republic, Greece, Turkey, India and Australia.

John G. Byrne, M.D., is the William S. Stoney Professor of Cardiac Surgery at Vanderbilt University School of Medicine and chair of the department of cardiac surgery at Vanderbilt Medical Center, Nashville, TN.

Before moving to Vanderbilt, he was associate chief and residency program director in the division of cardiac surgery at Brigham and Women’s Hospital, and associate professor of surgery at Harvard Medical School, Cambridge, MA. A graduate of the University of California, Davis, he received his medical degree in 1987 from Boston University. His postdoctoral training was completed at the University of Illinois affiliated hospitals and Brigham and Women’s Hospital in Boston.

Dr. Byrne is the author of more than 100 scientific articles on cardiac surgery and related areas. His patient care emphasis is

  • aortic root surgery,
  • coronary artery disease and
  • valve surgery

He is board-certified in general surgery and thoracic surgery.

John P. Cheatham, M.D., is director of cardiac catheterization and interventional therapy and codirector of The Heart Center at Nationwide Children’s Hospital, Columbus, Ohio. He is also the George H. Dunlap Endowed Chair in Interventional Cardiology and professor of pediatrics and internal medicine at The Ohio State University College of Medicine. Dr. Cheatham’s area of expertise is transcatheter intervention and hybrid therapy of newborns, children and adults with complex congenital heart disease. He has pioneered several new techniques and devices in non-surgical intervention and is a leader in developing hybrid therapies. He has been a principal investigator in numerous FDA-sponsored clinical trials evaluating non-surgical closure devices and stent therapy over the past two decades. Additionally, Dr. Cheatham designed the first hybrid cardiac catheterization suites and advanced imaging equipment at Nationwide Children’s Hospital. He serves as a consultant to various medical companies and proctors new transcatheter techniques and devices to other physicians around the world. Dr. Cheatham has implemented a formal physician exchange program with two of the leading medical institutions in China. In cooperation with China Red Cross, he is also the foreign director of the International Training Center for treatment of congenital heart disease in poor children. Dr. Cheatham has written more than 120 manuscripts, 16 book chapters, 300 national and international presentations and is co-editor of the book, Complications in Percutaneous Interventions for Congenital and Structural Heart Disease. After graduating from the University of Oklahoma College of Medicine, he completed his residency at Boston Children’s Hospital, followed by a fellowship in Pediatric Cardiology at Texas Children’s Hospital in Houston.

W. Randolph Chitwood, Jr., M.D., is senior associate vice chancellor for health sciences and chief of cardiovascular services at East Carolina University Department of Surgery, Greenville, N.C. Dr. Chitwood is a leading international pioneer in minimally invasive and robotic heart surgery. The Robotic Surgical Center at East Carolina University has trained more than 350 surgeons. His research activities relate to myocardial preservation, simulation in surgery and endoscopic/robotic cardiac surgery. He was the principal investigator of the FDA robotic mitral valve trials that led to approval for use in the U.S. He is the son and grandson of “southwestern Virginia mountain doctors” who set the guidelines for his professional life. He graduated from Hampden-Sydney College and received his medical degree from the University of Virginia. After medical school, he completed the surgical residency at Duke University Medical Center under David C. Sabiston, M.D., an influential surgical educator of the era. At Duke he spent 10 years training in general and cardiothoracic surgery, as well as basic science research.

After his chief residency at Duke in 1984, he was selected to begin and head the new cardiac surgery program at the East Carolina University School of Medicine. Because of his prolific publication record as a resident and clinical acumen, his initial appointment was as a full professor of surgery. Except for a two-year hiatus as the chief of cardiothoracic surgery at the University of Kentucky, he has spent his entire career at East Carolina University, where he also served as chairman of the department of surgery. In 2003, he was named to be in charge of the development of the East Carolina Heart Institute, which now includes an integrated department of cardiovascular sciences as well as a $200 million heart hospital, outpatient, research and education center.

Larry S. Dean, M.D., is director of the University of Washington Medicine Regional Heart Center and is professor of medicine and of surgery at the University of Washington School of Medicine, Seattle. In addition to general cardiology, he is an expert in cardiac catheterization and interventional cardiology. He also conducts research on stents to keep blocked heart arteries open and on ways to prevent restenosis after stents are inserted. He is currently involved in the evaluation of percutaneous aortic valve replacement. Dr. Dean earned his M.D. from the University of Alabama School of Medicine, Birmingham, and served his internship and residency at the University of Washington. He then returned to the University of Alabama Hospital for fellowships in cardiovascular disease and in angioplasty. After nearly 15 years as a faculty member at the University of Alabama, he returned to the University of Washington to direct the Regional Heart Center. He is a fellow of the American College of Cardiology and is board-certified in internal medicine, cardiovascular disease and interventional cardiology. He is also a fellow of the American Heart Association and president-elect of the Society of Cardiovascular Angiography and Interventions.

Andrew Craig Eisenhauer, M.D., is director of the interventional cardiovascular medicine service at Brigham and Women’s Hospital and assistant professor of medicine at Harvard Medical School. His specialties are

  • interventional cardiology,
  • vascular medicine and
  • congenital and inherited diseases.

He earned his medical degree at New York University School of Medicine and served a residency at Peter Bent Brigham Hospital and a fellowship at Massachusetts General Hospital. He is certified in internal medicine, cardiovascular disease and interventional cardiology. His clinical interests are

  • endovascular therapy,
  • complex coronary disease,
  • peripheral vascular disease,
  • cerebrovascular disease,
  • congenital heart disease and structural heart disease

Douglas A. Murphy, M.D., is chief of cardiothoracic surgery at Saint Joseph’s Hospital and a cardiothoracic surgeon at Peachtree Cardiovascular and Thoracic Surgery, Atlanta. His areas of interest are robotically assisted heart surgery with an emphasis on repairing the mitral valve rather than replacing it. A graduate of the University of Pennsylvania Medical School, Philadelphia, he served an internship and residency at Massachusetts General Hospital, Boston, and at Emory University, Atlanta.

Khusrow Niazi, M.D., is an assistant professor at Emory University School of Medicine and director of peripheral and carotid intervention at Emory University Hospital Midtown, Atlanta. He earned his medical degree at King Edward Medical College, Lahore, Pakistan, and served an internship at Kettering Medical Center, Dayton, Ohio, and a fellowship at William Beaumont Hospital, Royal Oak, MI. He has published papers on stenting following rotational atherectomy, small vessel stenting for coronary arteries, imaging of lower extremities and treatment of peripheral arterial disease.

Jeffrey J. Popma, M.D., is director of innovations in interventional cardiology, a senior attending physician at Beth Israel Deaconess Medical Center and an associate professor of medicine at Harvard Medical School in Boston. Dr. Popma received his bachelor’s degree in economics from Stanford University, and his M.D. from Indiana University School of Medicine. He completed his internship, residency, chief residency and fellowship at University of Texas Southwestern Medical Center. He also completed an interventional cardiology fellowship at the University of Michigan. Dr. Popma is the past president of the Society for Cardiac Angiography and Intervention and is the co-chair of the ACC Interventional Council. He sits on the editorial boards of several publications, and reviews for several cardiology periodicals. Dr. Popma has more than 300 published peer-reviewed manuscripts.

Dr. Popma also directs the BIDMC Angiographic Core Laboratory and is principal investigator for more than 65 ongoing multicenter device studies within the research laboratory. Over the past 15 years, these trials have included a broad array of new technology, including bare-metal stents, drug-eluting stents, distal-protection devices, total-occlusion devices and carotid and peripheral revascularization procedures. His primary clinical interest currently is the use of percutaneous aortic valve replacement for patients with high-risk aortic stenosis.

Robert S. Poston, M.D., is chief of cardiac surgery at Boston Medical Center and associate professor of cardiothoracic surgery at Boston University School of Medicine. He has a strong background in minimally invasive cardiac bypass surgery and is a pioneer in using robotics, specifically the da Vinci Surgical System, to treat coronary artery disease. A graduate of the Johns Hopkins School of Medicine, Baltimore, Dr. Poston completed a residency in general surgery at the University of California, San Francisco, and continued his training with a research fellowship in cardiothoracic surgery at Stanford University School of Medicine, Palo Alto, CA, and a cardiothoracic residency at the University of Pittsburgh Medical Center.

Charanjit S. Rihal, M.D., is professor of medicine and director of the cardiac catheterization laboratory at Mayo Graduate School of Medicine, Mayo Clinic, Rochester, MN. A graduate of the University of Winnipeg, Dr. Rihal did his residency and fellowship at the Mayo Graduate School of Medicine and also earned an MBA at the Carlson School of Management, University of Minnesota. His medical interests are interventional cardiology, structural heart disease interventions and the management of quality and costs in healthcare.

Timothy A. Shapiro, M.D., is director of the Interventional Cardiology Fellowship Program and campus chief, interventional cardiology, at Lankenau Hospital, Lancaster, PA. A graduate of Yale University School of Medicine, he served his residency and a fellowship at the Hospital of the University of Pennsylvania.

Robert J. Siegel, M.D., is director of the Cardiac Non-Invasive Laboratory at Cedars-Sinai Medical Center, cardiology director of the Cedars-Sinai Marfan Center, and Rexford S. Kennamer, M.D., chair in cardiac ultrasound at Cedars-Sinai Medical Center, Los Angeles. Dr. Siegel is also professor of medicine in residence at the David Geffen School of Medicine at University of California, Los Angeles. He previously served as senior staff fellow in cardiac pathology at the Heart, Lung and Blood Institute of the National Institutes of Health, Bethesda, MD. Internationally recognized as one of the leading experts in the field of cardiovascular ultrasound, Dr. Siegel specializes in cardiovascular ultrasound, including transthoracic, transesophageal and intravascular methodologies. His research interests include

  • valvular heart disease,
  • therapeutic applications of ultrasound energy,
  • transesophageal and intraoperative echocardiography, and the
  • development and use of hand-held portable echocardiographic systems for clinical innovations.

In addition, he is involved with clinical research studies related to the diagnosis, assessment and management of patients with

  • Marfan syndrome,
  • hypertrophic cardiomyopathy and
  • pericardial and valvular heart disease.

Dr. Siegel is a fellow, and has previously served as the president of the California Chapter of the American College of Cardiology and president of the Los Angeles Society of Echocardiography. He has been active in numerous cardiovascular societies, including the American Heart Association, the American College of Cardiology and the American Society of Echocardiography. Dr. Siegel received his medical degree at Baylor College of Medicine, Houston, where he developed an interest in cardiology. He completed his medical residency at Emory University and at Los Angeles County + USC Medical Center. He completed his cardiology fellowship at Harbor-UCLA Medical Center.

Over the last two years Dr. Siegel has worked extensively with live 3D transesophageal echo in the cardiac intervention center and the operating room. He and his echocardiologist colleagues, doctors Shiota, Biner, Tolstrup and Gurudevan, have worked closely at Cedars-Sinai Medical Center in Los Angeles with the interventional cardiologists, doctors Kar and Makkar, as well as with the cardiac surgeons, doctors Trento and Fontana. They use live 3D TEE extensively for the assessment of structural heart disease. In addition, it is used on a regular basis for the guidance of percutaneous procedures for mitral valve e-clip repair, mitral balloon valvuloplasty, aortic and pulmonic valve replacement, left atrial appendage exclusion by the Watchman device as well as for ASD closure.

Sudhir P. Srivastava, M.D., president of the International College of Robotic Surgery at St. Joseph’s Hospital, Atlanta, is a pioneer in performing beating heart totally endoscopic coronary artery bypass surgeries. Previously, he was assistant professor of surgery and director of robotic and minimally invasive cardiac surgery at the University of Chicago Medical Center. Dr. Srivastava specializes in robotically assisted totally endoscopic coronary artery bypass surgery. He has performed approximately 1,000 robotic cardiothoracic surgical procedures, of which 450  have been single- and multivessel beating heart totally endoscopic coronary bypass (BH TECAB) procedures. He has keen interest in hybrid coronary revascularization in TECAB patients to achieve complete revascularization.

Dr. Srivastava has helped launch robotic revascularization programs throughout the world. He has performed numerous live BH TECAB demonstrations both in the U.S. and abroad, and continues to be a presenter and invited speaker at numerous national and international scientific meetings. He earned his medical degree at the Jawahar Lal Nehru Medical College in Ajmer, India and immigrated to the U.S. in 1972. He completed his cardiothoracic surgery residency at the hospitals associated with the University of British Columbia, Vancouver, Canada.

Francis P. Sutter, D.O., F.A.C.S., is clinical professor of surgery at Thomas Jefferson University-Jefferson Medical College, Philadelphia, and chief of cardiothoracic surgery at Lankenau Hospital, Main Line Health System, Wynnewood, PA. A graduate of Philadelphia College of Osteopathic Medicine, his surgical residency and a cardiothoracic fellowship were completed at Thomas Jefferson University Hospital.

Mark R. Vesely, M.D., is an assistant professor of medicine at the University of Maryland School of Medicine. He completed medical school at the George Washington University and postgraduate training—an internal medicine residency and fellowships in cardiovascular disease and interventional cardiology—at the University of Maryland. He is board-certified in internal medicine, cardiovascular disease, nuclear cardiology and interventional cardiology. Dr. Vesely is the associate program director of the Interventional Cardiology fellowship at University of Maryland. His special interests include the partnered approach (interventional cardiologists and cardiac surgeons) for hybrid coronary revascularization and structural heart disease interventions. Additional research interests include investigation of techniques to minimize acute myocardial infarction injury with ventricular-assist devices and adult stem cell therapies.

David X. M. Zhao, M.D., Ph.D., is an associate professor of medicine and cardiac surgery, Harry and Shelley Page Chair in Interventional Cardiology, director of the Cardiac Catheterization Laboratories and interventional cardiology director of the Interventional Cardiology Fellowship Training Program, Vanderbilt University School of Medicine, Nashville, TN. He earned his medical degree at Shanghai Medical University, Shanghai, P.R. China, and his Ph.D. in immunology at Queensland University, Brisbane, Australia. His postdoctoral training was at Zhongshan Hospital, Shanghai Medical University, Shanghai, P.R. China, The Prince Charles Hospital, Brisbane, Australia, and Brigham and Women’s Hospital, Boston.

http://www.expo.acc.org/acc12/CUSTOM/images/ACC12/ACC.10%20Hybrid%20Suite%20Directory.pdf

Part Two

Cardiac Surgery

 

Cardiac Surgery @ Cleveland Clinic: Traditional OR & Hybrid Cath Lab/OR Suite

Nation #1 for 19 consecutive years – The Heart Center: Miller Family Heart & Vascular Institute @ Cleveland Clinic

The Sydell and Arnold Miller Family Heart & Vascular Institute is one of the largest, most experienced cardiovascular specialty groups in the world. Our physicians are committed to providing the most advanced diagnostic and treatment options, better outcomes and improved quality of life. U.S.News & World Reporthas ranked Cleveland Clinic as the No.1 heart program in America every year since 1995.

Departments & Centers:

Below we present two articles on Cardiac Surgery @ Mayo Clinic 

Cardiac Surgery @ Mayo Clinic: Traditional OR & Hybrid Cath Lab/OR Suite 

Coronary Reperfusion Therapies: CABG vs PCI – Mayo Clinic preprocedure Risk Score (MCRS) for Prediction of in-Hospital Mortality after CABG or PCI

Larry H. Bernstein, MD, FCAP and Aviva Lev-Ari, PhD, RN

Comparison of the 10-year and 15-year survivals after CABG demonstrated benefit from a change in graft sources used at the Mayo Clinic and widely adapted by others: vascular grafts from the left internal mammary artery (LIMA) instead of just leg veins, for multiple grafts (up to 3), LIMA-to-LAD plus grafts using LIMA or radial artery vs LIMA/saphenous vein (SV).

CABG Survival in Multivessel Disease Patients: Comparison of Arterial Bypass Grafts vs Saphenous Venous Grafts

Larry H. Bernstein, MD, FCAP and Aviva Lev-Ari, PhD, RN

Part Three 

Invasive Interventions with Complications

In the following article we covered multiple etiologies for cardiovascular complications related to invasive interventions: cardiovascular and peripheral arterial or peri- and post- cardiac surgery of the open heart type.

Cardiovascular Complications: Death from Reoperative Sternotomy after prior CABG, MVR, AVR, or Radiation; Complications of PCI; Sepsis from Cardiovascular Interventions

Justin D Pearlman, MD, PhD, FACC and Aviva Lev-Ari, PhD, RN

http://pharmaceuticalintelligence.com/2013/07/23/cardiovascular-complications-of-multiple-etiologies-repeat-sternotomy-post-cabg-or-avr-post-pci-pad-endoscopy-andor-resultant-of-systemic-sepsis/

This article covers types of Cardiovascular Complications derived from the following THREE types of assault on the Human body, two related to cardiac invasive interventions, the last due to its systemic nature is taking a fatal Cardiac toll: the Sepsis condition causing cardiac failure.

Three types of Cardiovascular Complications:

I. Risk of Injury During Repeat Sternotomy – following CABG orAortic Valve Replacement, both done in Open Heart Surgery

II. Complications After Percutaneous Coronary intervention (PCI) and endovascular surgery for Peripheral Artery Disease (PAD)

  • (a) Post PCI, and
  • (b) PAD Endovascular Interventions: Carotid Artery Endarterectomy

III. Cardiac Failure During Systemic Sepsis

This article does NOT cover the following two types of Cardiovascular Complications:

1. Trauma Injury causing cardiac arrest, lung collapse or cardiogenic shock

2. Surgical Complication of Non-cardiac surgery type causing cardiac arrest, i.e, Surgery of Joint Replacement causing sepsis causing death or death caused by complications of surgery i.e., blood loss, viral infection, emboli, thrombus, stroke, or cardiogenic shock not related to Cardiovascular and Cardiac invasive interventions

The e-Reader is advised to consider the following expansion on the subject matter carrying the discussion to additional related clinical issues:

Larry H Bernstein, Advanced Topics in Sepsis and the Cardiovascular System at its End Stage

http://pharmaceuticalintelligence.com/2013/08/18/advanced-topics-in-sepsis-and-the-cardiovascular-system-at-its-end-stage/

Bernstein, HL, Pearlman, JD and A. Lev-Ari  Alternative Designs for the Human Artificial Heart: The Patients in Heart Failure – Outcomes of Transplant (donor)/Implantation (artificial) and Monitoring Technologies for the Transplant/Implant Patient in the Community

http://pharmaceuticalintelligence.com/2013/08/05/alternative-designs-for-the-human-artificial-heart-the-patients-in-heart-failure-outcomes-of-transplant-donorimplantation-artificial-and-monitoring-technologies-for-the-transplantimplant-pat/

Pearlman, JD and A. Lev-Ari Cardiac Resynchronization Therapy (CRT) to Arrhythmias: Pacemaker/Implantable Cardioverter Defibrillator (ICD) Insertion

http://pharmaceuticalintelligence.com/2013/07/22/cardiac-resynchronization-therapy-crt-to-arrhythmias-pacemakerimplantable-cardioverter-defibrillator-icd-insertion/

Read Full Post »

Emerging Clinical Applications for Cardiac CT: Plaque Characterization, SPECT Functionality, Angiogram’s and Non-Invasive FFR

Author, and Content Consultant to e-SERIES A: Cardiovascular Diseases: Justin Pearlman, MD, PhD, FACC

and

Article Curator: Aviva Lev-Ari, PhD, RN

Article ID #69: Emerging Clinical Applications for Cardiac CT: Plaque Characterization, SPECT Functionality, Angiogram’s and Non-Invasive FFR. Published on 7/17/2013

WordCloud Image Produced by Adam Tubman

 

UPDATED on 7/25, 2018

VIDEOS | CT ANGIOGRAPHY (CTA) | JULY 19, 2018

VIDEO: Using FFR-CT in Everyday Practice

Kavitha Chinnaiyan, M.D., FACC, FSCCT, associate professor, Oakland University, William Beaumont School of Medicine, Royal Oak, Mich. She presented at the Society of Cardiovascular Computed Tomography (SCCT) 2018 meeting.

VIEW VIDEO 

https://www.dicardiology.com/videos/video-using-ffr-ct-everyday-practice?eid=333021707&bid=2184627

Related FFR-CT Content:

Clinical Applications of FFR-CT

VIDEO: Implementation and the Science Behind FFR-CT — interview with James Min, M.D.

VIDEO: Early U.S. Experience With FFR-CT in Evaluating ED Chest Pain Presentation — interview with Simon Dixon, M.D.

VIDEO: Status of FFR-CT Adoption in the United States — interview with Campbell Rogers, M.D.

Clinical studies of coronary anatomy by computed tomography use equipment with various numbers of concurrent slices through the heart: 1, 4, 16, 32, 64, 128, and recently 256 or more. Like interventional catheterization, iodine is injected to make the inside of the coronary arteries opaque to xray transmission, to create contrast (otherwise the xray of the coronary tree would be like a photograph of a white polar bear in a snow storm; the contrast acts like spray paint). Computed tomographic angiography (CTA) uses a similar or higher dye load than catheterization, and provides generally lower imaging quality than catheterization but with 3-dimensional reconstruction instead of flat projection (hundreds of linear views at different angles versus one or two image planes at a time). The results from CTA are generally deemed qualitative: whther or not there are potentially flow-limiting lesions in the major branch arteries that supply the heart (with exception: the posterior descending artery to the inferior wall of the heart is not reliably seen). Catheter-based projection coronary angiography sees smaller branches with finer ability to measure the degree of lumen narrowing. However, other imaging methods show greater promise in identifying plaque character. The following examines initial enthusiasm for improvements in CTA which offer better results compared to current clinical CTA and hope to offer advantages over catheter-based methods beyond the avoidance of catheters.

I. Cardiac CT Challenging Functionality of SPECT and Angiogram

Noninvasive computed tomography (CT) perfusion imaging added to CT angiography accurately identifies flow-limiting coronary lesions that need to be treated, results of the CORE320 trial show.

Dr João AC Lima (Johns Hopkins University, Baltimore, MD) presented results of the 381-patient, 16-center trial, which showed that stress CT myocardial perfusion analysis (CTP) significantly improves the diagnostic power of rest CT angiography (CTA) alone. The study also showed that the CTA+CTP strategy has about the same power to identify patients who need revascularization within 30 days as the current standard strategy of invasive angiography plus a single photon-emission computed tomography (SPECT) myocardial perfusion imaging (MPI) test.

Lima explained that the potential advantage of the CT-based approach is that it can obtain information on myocardial perfusion and coronary flow in two scans about 10 minutes apart and is noninvasive.

All patients in the study had been referred for an invasive angiogram to investigate suspected or known coronary artery disease (CAD), but all patients underwent a rest CTA, stress CTP, and SPECT-MPI test in addition to the invasive angiogram. Invasive angiography alone identified apparently obstructive coronary disease in 59% of patients, but adding the SPECT-MPI information reduced that number to 38%.

The accuracy of the CTA+CTP approach was measured as the area under the receiver-operating-characteristic curve. When 50% greater stenosis on invasive angiography was set as the reference standard for a flow-limiting stenosis, the accuracy of the CTA+CTP approach for detecting flow-limiting CAD was 0.87 on a per-patient basis. When the standard was >70% stenosis, the accuracy of the CTA+CTP approach was 0.89.

 

 VIEW VIDEO on CORE320 with Dr João Lima
Flow Limiting Lesion (low perfusion) vs. Anatomic Stenosis Severity
SOURCES

II. FFR-CT

Results of the Diagnosis of Ischemia-Causing Stenoses Obtained via Noninvasive Fractional Flow Reserve (DISCOVER FLOW) study show that the coronary stenoses that cause ischemia can be identified noninvasively with computer analysis of coronary computed tomography angiograms (CCTAs) [1].

“I think it’s a potential game-changer, because for the first time you have the ability to look at coronary stenosis and ischemia simultaneously, [and] you have the ability to pinpoint the lesion that is causing the ischemia,” DISCOVER FLOW senior investigator Dr James Min (Cedars-Sinai Medical Center, Los Angeles, CA) told heartwire. “You can imagine a scenario where somebody has an abnormal stress test and then you go in and you do an angiogram and see four or five stenoses, but you don’t really know which one caused the ischemia.” But this new “virtual fractional flow reserve” process—or FFRCT—can quantify the fractional flow reserve for each lesion with the data taken from a CCTA, thereby revealing which stenoses are causing ischemia and ought to be treated, as well as which stenoses do not need to be treated. “We’ve never before had this one-stop shop to . . . pinpoint the lesions that cause the ischemia noninvasively.”

As reported by heartwire at EuroPCR 2011, in DISCOVER FLOW, Dr Bon-Kwon Koo (Seoul National University Hospital, Korea) and colleagues used computation of FFRCT to assess 159 vessels in 103 patients undergoing CCTA. Results of the study are published in the November 1, 2011 issue of the Journal of the American College of Cardiology.

All of the patients also underwent invasive CCTA and invasive catheter FFR imaging. Ischemia was defined as an FFR of <0.80 and anatomically obstructive coronary disease was defined as stenosis >50% as measured on the CCTA scan. The diagnostic performance of FFRCT and CCTA were assessed against invasive FFR as the reference standard. Of the patients in the study, 56% had at least one vessel with an FFR of <0.80.

Because only about half of stenoses over 50% actually cause ischemia, the specificity of traditional assessment of a stenosis by CCTA is below 50%. “The concern there is that you identify some high-grade stenoses that are angiographically confirmed, but the lesions don’t actually cause ischemia.” Fractional flow reserve measures how much of the blood flow is being blocked by a lesion, so it is about 25% more accurate than traditional CCTA at picking out lesions that cause ischemia, Min explained.

Per vessel diagnostic accuracy FFRCT and CCTA (reference for both was invasive FFR) 

Imaging technology Accuracy(%) Sensitivity(%) Specificity(%) Positive predictive value (%) Negative predictive value (%)
FFRCTa  84.3 87.9 82.2 73.9 92.2
CCTAb 58.5 91.4 39.6 46.5 88.9

a. Ischemic defined as <0.80

b. Ischemia defined as stenosis >50%

FFRCT can assess stenoses from any CCTA scan—prospectively gated or retrospectively gated—without any additional imaging techniques or changes to the acquisition parameters. Just as computational fluid dynamics can predict the behavior of an airplane wing under different environmental parameters, FFRCT can measure the flow of blood through a stenotic coronary based on the specific geometry of the patient’s coronaries and myocardium.

At the American Heart Association meeting in Orlando next month, Min will present results of a substudy from DISCOVER FLOW looking specifically at intermediate-grade stenoses (40%-69%), which present the most difficult treatment decisions. “If somebody sees a 90% stenosis or 10% stenosis, they are comfortable with what to do with that. But when you hit that 40% to 70% range—it’s possible that those lesions are ischemic, but you don’t know until you actually assess them,” Min said.

DISCOVER FLOW was designed to evaluate the accuracy of FFRCT on a per-vessel basis, but the more important demonstration of its value will be its ability to guide treatment decisions for each patient. TheDEFACTO trial, which finished enrollment at 17 centers about three weeks ago, is evaluating FFRCT per patient. “That’s the big one,” Min said. “DEFACTO will be the pivotal trial.” Specifically, the 285-patient DEFACTO trial is assessing the ability of CCTA plus FFRCT to determine the presence or absence of at least one hemodynamically significant coronary stenosis in each trial subject. Invasive catheter FFR is the reference standard. Min expects that study to be completed in the first quarter of 2012.

http://www.theheart.org/article/1299631.do

SOURCES

III. Ten Emerging Uses for Cardiac CT from SCCT 2013

July 11-14, 2013
Palais des congrès
Montréal, Québec, Canada

JULY 16, 2013  – heartwire

Dr Matthew Budoff (Los Angeles Biomedical Research Institute, CA), a longtime researcher in the use of cardiac CT, described what he believes to be the most important uses for CT today [1].

First, CT angiography is emerging as “a single tool that gives us [information about] function and anatomy,” he told the audience.

Second, it is now known that patients are more likely to have a cardiovascular event if they have low-attenuation plaque (soft plaque), positive remodeling, and spotty calcification, he explained. If a clinician were limited to looking only at plaque or stenosis, he would advise him or her to “just read the CTA for plaque and plaque characteristics and [don’t] read it for stenosis severity, and you’ll probably serve your patients better in predicting risk” of a cardiovascular event. “I think in future we’re going to be using plaque characterization in every case,” he added. “I certainly don’t advocate stenting these patients [who have vulnerable plaque] yet, but . . . I do treat these patients more aggressively.”

Third, coronary CT angiography is a noninvasive way to identify complex aortic-valve geometry and guide TAVR.

“With perfusion imaging, TAVR, and plaque assessment leading the way, the increased utilization of CTA is certain,” Budoff concluded. “However, more validation work is needed to ensure that industry and payers accept these applications.”

Speaking to heartwire, Budoff singled out TAVR as “an easy launching point for doctors to get familiar with” CT angiography. He also believes that using CT for “heart-failure assessment or even plaque assessment . . . will really add value to their practice.” CT also allows clinicians to “start getting a handle on what’s causing stenosis [in a patient], what it looks like, and . . . how severe the stenosis is.”

In a separate presentation [2], Dr James K Min (Cedars-Sinai, Los Angeles, CA) identified the same three clinical applications as Budoff in his “top 10 things to watch” in coronary CT in the coming year. He identified his “up-and-coming areas to watch” in the following order:

  • Dual-energy CT scanners. This hardware, when combined with new software, is producing enhanced image quality that allows, for example, a “plaque biopsy,” which provides detailed information about plaque characteristics.
  • Myocardial CT perfusion. “We’ve looked at this for seven years, and I think it’s starting to become ready for prime time,” said Min. In the next year, he expects investigators to figure out exactly how to use CT to look at coronary flow reserve.
  • Computational fluid dynamics. Exciting work is being done, for example, using a virtual stent to see how a real stent would potentially resolve a patient’s ischemia.
  • Plaque. Coronary CT can do more than identify how many vessels are blocked, he said, echoing Budoff’s words. It is enabling investigators to study the pathogenesis of atherosclerosis. “We’re going to be able to identify plaque characteristics beyond stenosis for the prediction of acute MI,” Min said.
  • Structural heart disease. CT is already being used to help guide TAVR to reduce postsurgery complications.
  • Radiation-dose reduction. Min weighed in and said, “I think it’s becoming a nonissue.” He noted that during the past year, investigators reported how coronary CT angiography can be used with radiation doses as low as 0.01 mSv, (should be 1mSv) whereas a screening mammogram exposes a woman to 0.05 mSv of radiation. (1/5 of mammography)
  • Contrast-agent reduction.”I think we will see improvements—we will get to the 10-cc scan,” Min predicted.
  • Appropriate-use criteria. Physicians are continuing to identify which patients benefit from cardiac CT, as the technology is advancing.
  • Two trials. Among the many ongoing trials in the field, Min identified two to watch. The PROMISEstudy is comparing functional vs anatomic testing to identify heart disease. The Coronary Computed Tomographic Angiography for Selective Cardiac Catheterization (CONSERVE) trial is looking at using CT as a “gatekeeper” to the cath lab, to identify which patients should be sent for invasive coronary angiography and which ones have only have mild stenosis and could be sent home and treated with medical therapy .
  • Worldwide growth in CT. Collaboration with investigators around the world is growing, and the SCCT meetings next year in Hawaii and China will offer more opportunities for this.
Budoff has received research/grant support from HeartFlow, study funding from Wakunaga of America and GE Healthcare and has been a consultant and speaker for GE Healthcare. Min has received research/grant support fromGE Healthcare, Phillips Healthcare, and Vital Images and study funding from Astellas. He has been a consultant for GE Healthcare and Arineta and on the speaker’s bureau for GE Healthcare. He holds equity interest in TC3 and MDXX.

Sources

  1. Budoff MJ. Emerging Clinical applications for cardiac CT. Society of Cardiovascular Computed Tomography 2013 Annual Scientific Meeting; July 12, 2013; Montreal, QC.
  2. Min JK. The future of cardiac CT. What will the next 12 months bring? Society of Cardiovascular Computed Tomography 2013 Annual Scientific Meeting; July 12, 2013; Montreal, QC.

Related links

SOURCE

http://www.theheart.org/article/1561163.do?utm_medium=email&utm_source=20130717_heartwire&utm_campaign=newsletter

IV. Stress CT Perfusion matches SPECT for detecting Myocardial Ischemia

Montreal, QC – In stress testing using regadenoson (Lexiscan, Astellas), detection rates of myocardial ischemia were similar with less invasive computed-tomography (CT) perfusion imaging compared with the reference method, single-photon-emission CT (SPECT) imaging, in a phase 2 trial [1].

JULY 18, 2013 

Regadenoson, a selective adenosine-receptor agonist that produces coronary vasodilation in patients unable to undergo exercise stress testing, is the most common agent used to induce pharmaceutical stress in SPECT tests in the US; it was used off-label for the CT imaging.

Dr Ricardo C Cury (Baptist Hospital of Miami, FL) presented the trial results here at a late-breaking clinical-trials session at the Society of Cardiovascular Computed Tomography (SCCT) 2013 Scientific Meeting.

To heartwire, Cury noted that this trial established noninferiority of regadenoson stress CT perfusion to the reference method, regadenoson SPECT, to detect or exclude myocardial ischemia, which was the primary study outcome.

“This is the second multicenter trial validating [regadenoson] stress CT perfusion, which [builds on the accumulating supporting data from] many single-center studies,” he said, adding that it is still too early, however, to implement these findings into clinical practice.

To heartwire, session moderator Dr John Hoe (Parkway Health Radiology, Singapore) commented that “this is quite an important multicenter trial . . . and the results look very good.” Echoing Cury, he added that “this [research] is slowly [progressing] along the path to validate [regadenoson] CT perfusion as a technique to assess myocardial ischemia.”

In study, 39% of patients had suspected CAD

This was a crossover study conducted at 11 sites in the US, using six types of CT scanners, including 64-, 128-, 256-, and 320-slice machines.

A total of 124 individuals with known (39%) or suspected CAD were randomized to either rest and stress SPECT using regadenoson on day 1, followed by rest and combined stress CT perfusion using regadenoson and coronary CT angiography on day 2; or the same tests in the reverse order.

At baseline, the subjects had a mean age of about 62 and an average body-mass index (BMI) of close to 30. Their average heart rate increased from 64 to 84 beats per minute with the stress-CT perfusion test.

Myocardial ischemia was defined as having two or more reversible defects.

High agreement, specificity, and sensitivity

When it came to detecting myocardial ischemia, CT perfusion imaging agreed with the findings of the reference method, SPECT, 87% of the time (95% CI 0.77-0.97).

“This was well above the specified primary end point for the agreement rate between SPECT and CT perfusion for the detection of ischemia,” Cury said.

Stress CT perfusion imaging also had a high specificity (84%) and sensitivity (90%) for detecting or excluding myocardial ischemia.

Similarly, when it came to detecting the presence or absence of one or more fixed myocardial defects, CT perfusion imaging agreed with the results of the reference method, SPECT, 86% of the time (95% CI 0.74-0.98).

Again, stress CT perfusion imaging had a high specificity (95%) and sensitivity (77%) for detecting or excluding fixed defects.

Used alone, compared with the reference standard of SPECT, stress CT perfusion diagnosed or excluded ischemia accurately in 85% of cases, whereas CT angiography alone made the correct diagnosis in 69% of cases. Thus, “stress CT perfusion may add significant [diagnostic] value to CT angiography alone,” Cury noted.

Regadenoson was well tolerated, and the most common adverse events were flushing or headache.

The study was funded by Astellas. Cury is a consultant for Astellas and has received research grants from Astellas and GE Healthcare. Hoe has received grant and research support and travel funding from Toshiba Medical Systems and is on its speaker’s bureau. 

SOURCE

http://www.theheart.org/article/1561685.do

V. New Protocol Limits Use Of SPECT MPI For Angina

Article Date: 07 May 2013 – 1:00 PDT

A new stress test protocol that investigates reducing the use of perfusion imaging in low risk patients undergoing SPECT myocardial perfusion imaging for possible anginasymptoms was found to be diagnostically safe, revealed a US retrospective analysis. The study, reported as an abstract¹ at the International Conference on Nuclear Cardiology and Cardiac CT (ICNC11) May 5 to May 8 in Berlin, Germany, predicted that using exercise ECG stress testing alone in patients with high exercise capacity would have had no adverse effects on their prognosis at five years.

“Our results are reassuring in that there are few patients whose diagnosis of coronary artery disease (CAD) would be missed,” said Milena Henzlova, the first author of the study. “Not only would widespread adoption of this approach reduce radiation exposure, it would also save considerable amounts of time and money.”

Single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) has been used for over 30 years to detect ischemia in patients with suspected CAD. In SPECT MPI patients are injected with radioactive agents (such as Tc-99m or Thallium 201) whose passage through the heart is viewed with a SPECT camera. By comparing the heart’s blood flow at rest and during stress (patients exercise on a treadmill, cycle ergometers or undergo pharmacological stress with vasodilators or dobutamine), cardiologists can determine if the myocardium receives sufficient blood supply, as well as the location and extent of underlying CAD.

“Because it’s non invasive and many patients with a chest pain syndrome don’t have coronary disease, SPECT MPI is often viewed as a ‘gate keeper’ to coronary angiography,” explained Lane Duvall, an investigator in the study.

While SPECT MPI represents a well established technique, the main disadvantage is that patients are exposed to diagnostic levels of radiation. In recent years intensive efforts have been made to reduce ionizing radiation associated with cardiac imaging due to concerns that it damages DNA in cells and may ultimately give rise to cancer. Indeed, extrapolating data from the survivors of the Hiroshima and Nagasaki atomic bombs, Andrew Einstein, from Columbia University Medical Center, New York, has estimated that the low levels of radiation encountered during medical imaging might lead to a 2% excess relative risk for future cancers.

Other studies have suggested that exercise treadmill testing alone may be sufficient to predict CVD outcome without use of SPECT MPI in low risk patients. In 2011, Bourque and colleagues from the University of Virginia, Charlottesville, reported that patients who exercise at >10 metabolic equivalents (METS), [the unit used to estimate the amount of oxygen used by the body during physical activity] during stress testing had a very low prevalence of significant ischemia and very low rates of cardiac events during follow-up².

The advantage of exercise treadmill testing is that it offers a quicker study that involves no radiation exposure, with prognostic information provided via a variety of treadmill scores, most notably the Duke Treadmill score. “This has led to investigators questioning the added value of SPECT MPI over exercise testing alone. There’s growing recognition that patients need to be treated as individuals and that those in whom the CVD risks are considered negligible shouldn’t be undergoing the risks of radiation exposure,” said Duvall.

In the current abstract, Henzlova, Duvall and colleagues, from the Mount Sinai School of Medicine, New York, US, set out to investigate retrospectively if a provisional injection protocol in which patients where they met certain criteria were converted to exercise treadmill tests without imaging maintained diagnostic accuracy and prognostic ability. For the retrospective study, data was reviewed from a total of 24,689 patients who had undergone SPECT MPI between February 2004 and June 2010. After exclusion of patients older than 65 years of age, who had known CAD and uninterruptable resting ECGs, 5,352 subjects were identified for analysis.

Subjects were divided into those who would have met all the criteria for not undergoing SPECT MPI (the No injection group n= 1,561 [29.2%]) and those who met the criteria for undergoing SPECT MPI (the Yes injection group, n=3,791, [70.8%]). For the study the criteria laid down for patients considered eligible for not undergoing SPECT MPI included achieving a maximal predicted heart rate >85%, > 10 METs of exercise, no symptoms of chest pain or significant shortness of breath during stress, and no ECG changes (ST depression or arrhythmia). Outcomes for the two groups at five years were then compared based on their actual myocardial perfusion imaging results and all-cause mortality that had been retrospectively identified from the National Death Index.

At a mean follow-up of 60.6 months, 1.1% of patients had died in the No-injection cohort compared to 2.2% Yes injection cohort (P=.01). Furthermore perfusion results were abnormal in 5.9% of the No injection group compared to 14.4% in the Yes injection group (P<.0001). The risk adjusted survival at the end of the follow up was 98.8% in the No injection group compared to 97.2% for patients found to have normal perfusion in the Yes injection group (P=0.009).

“Withholding isotope injections in these selected patients was found to be diagnostically safe with a small percentage of ‘missed’ abnormal perfusion studies, a very low rate of significant stress perfusion defects and left ventricular ischemia, and a prognosis which was better than their counterparts who were injected with the isotope,” said Duvall.

Eliminating the need for imaging in 6% of the 9 million SPECT MPI studies performed annually in the US, the authors added, would result in significant cost savings and the total test time would be halved from three hours to roughly one hour. “There’s a need to accept that less can be more. By individualizing therapy we can reduce radiation exposure and costs without jeopardizing the quality, the diagnostic utility or missing something important,” said Henzlova. 

REFERENCES
1. M Henzlova, EJ Levine, S Moonthungal, et al. A protocol for the provisional use of perfusion imaging with exercise stress testing. Abstract no 70123.
2. Bourque JM, Charlton GT, Holland BH, et al. Prognosis in patients achieving >10 METS on exercise stress testing: was SPECT imaging useful? J Nucl Cardiol 2011, 2 230-7.
European Society of Cardiology
SOURCE

VI. Contemporary Stress Echo good for Risk Stratification in Chest-Pain Units

12/20/2012, Lisa Nainggolan

London, UK – Doctors in a London chest-pain unit have shown that employing contemporary stress echocardiography in patients with suspected acute coronary syndrome (ACS) but normal ECG and negative troponin is a successful approach for risk stratification [1].

Stress echo is feasible and safe and allows early triage and rapid discharge of patients, plus it is a good predictor of hard events, say Dr Benoy N Shah (Royal Brompton Hospital, London, UK) and colleagues in their paper published online December 18, 2012 in Circulation: Cardiovascular Imaging. Those with an abnormal stress echo had a 13- to15-fold increased risk of MI or death compared with those who had a normal stress echo, they report.

“Stress echo is a very effective gatekeeper for patients undergoing further risk stratification,” senior author Dr Roxy Senior (Royal Brompton Hospital) told heartwire. “It helps select patients for coronary angiography [those with a positive stress echo] and allows immediate discharge of those patients with a negative result.”

Stress echo is perceived to be a technique that is difficult, but that is a misconception.

But Senior says his chest-pain unit is the only one in the UK using this approach. “It is perceived to be a technique that is difficult, but that is a misconception. We have nine stress-echo operators, and it’s easy to train people. With contemporary techniques, which employ contrast in around 50% of cases, the images are quite clear and quick and easy to interpret. It’s very user-friendly. We want to show people around the world that it’s a very doable technique, so why don’t you use it?”

Stress echo also compares favorably with other tests used or proposed for risk stratification of such patients, he says. Exercise ECG is perhaps the most basic technique, “and we have shown that the downstream costs are lower with stress echo than with exercise ECG,” given that the latter provides such equivocal results [2], he explained. And with regard to other imaging modalities that have been employed in this way, computed tomography coronary angiography (CTCA) and single-photon-emission computed tomography (SPECT) require the use of ionizing radiation and have other drawbacks, he notes.

Nevertheless, he and his colleagues say that further, multicenter studies comparing stress echo with CTCA, SPECT, and other imaging techniques for this purpose “will help determine the most cost-effective means of investigating this acute patient population.”

Stress echo performed within 24 hours of admission

Shah and colleagues say that after they showed in 2007 that stress echo was more cost-effective than exercise ECG, they have been employing the former in day-to-day practice in their unit to assess patients who come in with severe chest pain, but whose troponin is negative at 12 hours and whose ECG is “nondiagnostic” (ie, does not suggest any abnormality or shows only minor changes).

The current study is a retrospective look at the patients they have seen so far and is the first evaluation of the clinical impact of incorporating stress echo in a real-world chest-pain unit for the assessment of both short- and long-term prediction of hard events, they say.

“This was sort of an audit; we wanted to know, ‘Is this right? Or are we overcalling it?’ ” Senior explains.

He says the stress echos are performed, for the most part, “within 24 hours” of admission to the chest-pain unit, from 9 am-5 pm Monday to Friday. Those admitted on a weekend will wait slightly longer for a stress echo, he acknowledged. The stress echo is performed on a treadmill if the patient is capable of exercise; if not, a pharmacological stress test is performed using dobutamine. Approximately 30% of the patients in this study performed the test on a treadmill, Senior noted.

Results of the stress echo are available quickly and, if negative, the patient is discharged immediately. If they are positive, the patient is investigated further.

Event rate much higher for those with a positive stress echo

In the study, 839 consecutive patients were assessed; 802 were available for follow-up. Approximately 75% of them had a normal stress echo and were discharged.

“The 30-day readmission rate for all patients was extremely low,” Senior notes, but for those with a negative stress echo it was exceedingly low (at 0.3% compared with 1.1% for those with an abnormal stress echo).

A normal stress echo carried a 99.7% event-free survival for death and 99.5% event-free survival for all hard events in the first year of follow-up; these event rates increased 15-fold and 13-fold respectively if the stress echo was abnormal.

There were 15 “hard” events, 0.5% in the normal stress echo group and 6.6% in the abnormal stress echo group in the first year. At two years, 2.3% of those in the normal stress echo group had died or had a nonfatal MI compared with 9.6% in the stress echo abnormal group, and at three years these figures were 5.1% and 21.1%, respectively. The median follow-up for the study was 27 months.

“For the patients who had a positive stress echo, the event rate was much higher,” Senior notes. Of these 184 patients, 98 had ischemia and most of these underwent coronary angiography, with 57 demonstrating flow-limiting coronary artery disease and 30 subsequently undergoing revascularization.

Among all prognostic variables, only abnormal stress echo (hazard ratio 4.08) and advancing age (HR 1.78) predicted hard events in multivariable regression analysis.

Stress echo should be much more widely used in chest-pain units

“This study demonstrates the excellent feasibility and safety of stress echo in a real-world chest-pain-unit setting, with rapid early triaging and discharge and accurate risk stratification,” the researchers say.

“The two most important outcomes for patients reassured and discharged from the emergency department are that they do not suffer early mortality or early readmission with the same complaint. Our study highlights the excellent negative predictive value of stress echo and very low 30-day readmission rate.”

In addition, the results show that stress echo “appropriately influences the use of coronary angiography and subsequent revascularization” and overall support the wider use of this technique in chest-pain units, they conclude.

Senior has previously received consultancy fees from Lantheus Medical. The coauthors report they have no conflicts of interest.
REFERENCES

Sources

  1. Shah BN, Balaji G, Alhajiri A, et al. The incremental diagnostic and prognostic value of contemporary stress echo in a chest pain unit: mortality and morbidity outcomes from a real-world setting. Circ Cardiovasc Imaging 2012; DOI:10.1161/CIRCIMAGING.112.980797. Available at: http://circimaging.ahajournals.org.
  2. Jeetley P, Burden L, Stoykova B, Senior R. Clinical and economic impact of stress echocardiography compared with exercise electrocardiography in patients with suspected acute coronary syndrome but negative troponin: a prospective randomized controlled study. Eur Heart J. 2007; 28:204-211.

http://www.theheart.org/article/1490677.do

VII. PET Perfusion Imaging Improves Risk Estimates

12/5/2012 Reed Miller

Boston, MA – New data from a large multicenter registry suggest that positron-emission-tomography (PET) myocardial perfusion imaging (MPI) can greatly improve the accuracy of risk estimation in coronary disease patients compared with a model based on traditional risk factors [1].

Only small single-center studies have demonstrated the prognostic value of PET MPI in predicting which patients are at greatest risk for coronary disease events. So Dr Sharmila Dorbala (Brigham and Women’s Hospital, Boston) and colleagues analyzed outcomes from 7061 patients from four centers who underwent a clinically indicated rest/stress rubidium-82 PET MPI test.

Results of the study are published online December 5, 2012 in the Journal of the American College of Cardiology. “The results of the current study are critical to advance the field and guide more effective use of PET MPI in clinical practice,” Dorbala et al state.

Median follow-up was 2.2 years. During follow-up, there were 169 cardiac arrests and 570 all-cause deaths. Net reclassification improvement and integrated discrimination analyses showed that the risk-adjusted hazard of cardiac death increases as the percentage of abnormal myocardium increases. A mildly abnormal stress test is associated with a 2.3 times greater risk of cardiac death than a normal test. The hazard ratio for a severely abnormal test is 4.9.

The addition of PET MPI measurements of myocardial ischemia and myocardial scarring to traditional clinical information improves the performance of a risk prediction model based on traditional risk factors (C statistic 0.805-0.839) as well as risk reclassification for cardiac death, with small improvements in risk assessments for all-cause death. The assessment of the magnitude of ischemia and scar added to the reclassification of risk for cardiac death in one in every nine patients who underwent clinical PET MPI in the study.

Unlike computed-tomography (CT) coronary angiography, perfusion imaging provides information about myocardial blood flow and accounts for underlying coronary disease, collateral flow, and myocardial adaptation to wall stress and can be used in patients with renal insufficiency, the authors point out. Compared with single-photon-emission computed tomography (SPECT) perfusion imaging, PET MPI offers better image quality, test specificity for the diagnosis of obstructive coronary disease, and identification of scar and ischemia, according to Dorbala et al, and PET MPI uses a lower effective radiation dose. However, while the prognostic value of SPECT MPI has been described in tens of thousands of patients, the prognostic value of PET MPI has been studied in only a few thousand patients.

Does more risk information help?

The value of the prognostic information offered by PET MPI is not yet clear, according to an accompanying editorial by Drs Paul Schoenhagen and Rory Hachamovitch (Cleveland Clinic, OH) [2]. “Rather than assessing whether a test yields improvement in risk assessment, the focus [should be] shifted to whether a test can identify which patients will gain a benefit from a specific therapeutic approach,” they write. “The role of testing [should be] defined in the context of a specific intervention and whether the effectiveness of the intervention is improved by the use of an imaging study to identify optimal candidates for treatment.

“However, this process is neither simple nor inexpensive and will require prospective randomized clinical trials, validating the results and hypotheses generated by observational data,” the editorialists conclude.

Commenting on the study, Dr Kavitha Chinnaiyan (William Beaumont Hospital, Royal Oak, MI) toldheartwire, “While the details of downstream management of these patients are unclear in this paper, the association of ischemia with mortality is clear, as is the reclassification of risk. The next step in terms of management of ischemic patients is really the question here.” She also pointed out that the ongoingISCHEMIA trial, comparing angiography and revascularization plus optimal medical therapy with optimal medical therapy only, may provide more insights on the best option for patients who show more than mild ischemia on stress studies.

Dorbala has received research grants from Astellas Pharma and Bracco Diagnostics; has served on advisory boards for Astellas Pharma; and has received honoraria from MedXcel. Disclosures for the coauthors are listed in the paper.Schoenhagen and Hachamovitch report that they have no relationships relevant to the contents of this paper to disclose. Chinnaiyan has no relevant disclosures.

REFERENCES

  1. Dorbala S, Di Carli M, Beanlands RS, et al. Prognostic value of stress myocardial perfusion positron emission tomography. J Am Coll Cardiol 2013; DOI:10.1016/j.jacc.2012.09.044. Available at:http://content.onlinejacc.org.
  2. Schoenhagen P and Hachamovitch R. Evaluating the clinical impact of cardiovascular imaging: Is a risk-based stratification paradigm relevant. J Am Coll Cardiol 2013; DOI:10.1016/j.jacc.2012.09.044. Available at:http://content.onlinejacc.org.

SOURCE

Other related articles published on this Open Access Online Scientific Journal, include the following:

Fractional Flow Reserve (FFR) & Instantaneous wave-free ratio (iFR): An Evaluation of Catheterization Lab Tools for Ischemic Assessment

Justin D Pearlman, MD, PhD, FACC and Aviva Lev-Ari, PhD, RN

http://pharmaceuticalintelligence.com/2013/07/04/fractional-flow-reserve-ffr-instantaneous-wave-free-rario-ifr-an-evaluation-of-catheterization-lab-tools-for-ischemic-assessment/

 

CT Angiography (CCTA) Reduced Medical Resource Utilization compared to Standard Care reported in JACC

Aviva Lev-Ari, PhD, RN

http://pharmaceuticalintelligence.com/2013/05/16/ct-angiography-ccta-reduced-medical-resource-utilization-compared-to-standard-care-reported-in-jacc/

 

Acute Chest Pain/ER Admission: Three Emerging Alternatives to Angiography and PCI – Corus CAD, hs cTn, CCTA

Curator: Aviva Lev-Ari, PhD, RN

http://pharmaceuticalintelligence.com/2013/03/10/acute-chest-painer-admission-three-emerging-alternatives-to-angiography-and-pci/

 

Acute and Chronic Myocardial Infarction: Quantification of Myocardial Perfusion Viability – FDG-PET/MRI vs. MRI or PET alone

Justin D. Pearlman, MD, PhD and Aviva Lev-Ari, PhD, RN

http://pharmaceuticalintelligence.com/2013/05/22/acute-and-chronic-myocardial-infarction-quantification-of-myocardial-viability-fdg-petmri-vs-mri-or-pet-alone/

Read Full Post »