The Role of Informatics in The Laboratory

Larry H. Bernstein, M.D.

Introduction

The clinical laboratory industry, as part of a larger healthcare entrerprise, is in the midst of large changes that can be traced to the mid 1980’s, and that have accelerated in the last decade.   These changes are associated with a host of dramatic events that require accelerated readjustments in the work force, scientific endeavors, education, and the healthcare enterprise.   These changes are highlighted by the following (not unrelated) events:  globalization, a postindustrial information explosion driven by advances in computers and telecommunications networks, genomics and proteomics in drug discovery, consolidation in retail, communication, transportation, the healthcare and pharmaceutical industries.   Let us consider some of these events.   Globalization is driven by the principle that a manufacturer may seek to purchase labor, parts or supplies from sources that are less than is available at home.   The changes in the airline industry have been characterized by growth in travel, reductions in force, and ability of customers to find the best fares.   The discoveries in genetics that have evolved from asking questions about replication, translation and transcription of the genetic code, has moved to functional genomics and to elucidation of cell signaling pathways.   All of these changes were impossible without the information explosion.

The Laboratory as a Production Environment

The clinical laboratory produces about 60 percent of the information used by nurses and physicians to make decisions about patient care.   In addition, the actual cost of the laboratory is only about 3 – 4 percent of the cost of the enterprise.   The result is that the requirements for the support of the laboratory don’t receive attention without a proactive argument of how it contributes to realizing the goals of the organization.   The key issues affecting laboratory performance are:  staffing requirement, instrument configuration, workflow, what to send out, what to move to point-of-care, how to reconfigure workstations, and how to manage the information generated by the laboratory.

Staffing requirement, instrument configuration and workflow are being addressed by industry automation.   The first attempt was based on connecting instruments by tracks.   This  system proved unable to handle STAT specimens without a noticeable degrading of turnaround time.   The consequence of the failure is to drive creation of  a parallel system of point-of-care, and connecting them in a network with a RAWLS.  Another adjustment was to have an infrastructure for pneumatic tube delivery of specimens, and to redesign the laboratory. This had some success, but required capitalization.   The pneumatic tube system could be justified on the basis to a value to the organization in supporting services besides the laboratory. The industry is moving in the direction of connected modules that share an automated pipettor and reduce the amount of specimen splitting.   These are primarily PREANALYTICAL refinements.

There are other improvements that affect quality and cost that are not standard, and should be.   These are:  autoverification, embedded quality control rules and algorithms, and incorporation of the X-bar into standard quality monitoring.   This can be accomplished using middleware between the enterprise computer and the instruments designed to do more than just connect instruments with the medical information system.   The most common problem encountered when installing a medical repository is the repeated slowdown of the system as more users are connected with the system.   The laboratory has to be protected from this phenomenon, which can be relieved considerably by an open-architecture.   Another function of middleware will be to keep track of productivity by instrument, and to establish the cost per reportable result.

The Laboratory and Informatics

A few informatics requirements for the processing of tests are:

  1. Reject release of runs that fail Quality Control rules
  2. Flag results that fail clinical rules for automatic review
  3. Ability to construct a report that has correlated information for physician review, regardless of where the test is produced (RBC, MCV, reticulocytes and ferritin)
  4. Ability to present critical information in a production environment without technologist intervention (platelet count or hemoglobin in preparation of transfusion request)
  5. Ability to download 20,000 patients from an instrument for review of reference ranges
  6. Ability to look at quality control of results on more than one test on more than one instrument at a time
  7. Ability to present risks in a report for physicians for medical decisions as an alternative to a traditional cutoff value

I list essential steps of the workload processing sequence and identification of informatics enhancement of the process (bolded):

Prelaboratory (ER) 1:

Nurse draws specimens from patient (without specimen ID) and places tubes in bag labeled with name

Nurse prints labels after patient is entered.

Labels put on tubes

Orders entered into computer and labels put on tubes

Tubes sent to laboratory

Lab test  is shown as PENDING

Prelaboratory 2:

Tubes in bags sent to lab (by pneumatic tube)

Time of arrival is not same as time of order entry (10 minutes later)

If order entry is not done prior to sending specimen – entry is done in front processing area –

Sent to lab area 10 minutes later after test is entered into computer

Preanalytical:

Centrifugation

Delivery to workareas (bins)

Aliquoting for serological testing

Workstation assignment

Dating and amount of reagents

Blood gas or co-oximetry – no centrifugation

Hematology – CBC – no centrifugation
send specimen for Hgb A1c

Send specimen for Hgb electrophoresis and Hgb F/Hgb A2

Specimen to Aeroset and then to Centaur

Analytical:

Use of bar code to encode information

Check alignment of bar code

Quality control and calibration at required interval – check before run

Run tests

Manual:

2 hrs per run

enter accession #

enter results 1 accession at a time

Post analytical:

Return to racks or send to another workarea

Verify results

Enter special comments

Special  problems:

Calling results

Add-on tests

Misaligned bar code label

Inability to find specimen

Coagulation

Manual differentials

Informatics and Information Technology

The traditional view of the laboratory environment has been that it is a manufacturing center, but the main product of the laboratory is information, and the environment is a knowledge business.   This will require changes in the education of clinical laboratory professionals.   Biomedical Informatics has been defined as the scientific field that deals with the storage, retrieval, sharing, and optimal use of biomedical information, data, and knowledge for problem solving and decision making. It touches on all basic and applied fields in biomedical science and is closely tied to modern information technologies, notably in the areas of computing and communication.   The services supported by an informatics architecture include operations and quality management, clinical monitoring, data acquisition and management, and statistics supported by information technology.

The importance of a network architecture is clear.   We are moving from computer-centric processing to a data-centric environment. We will soon manage a wide array of complex and inter-related decision-making resources. The resources, commonly referred to as objects and contents, can now include voice, video, text, data, images, 3D models, photos, drawings, graphics, audio and compound documents.  The architectural features required to achieve this is in Fig 1.

According to Coeira and Dowton (Coiera E and Dowton SB. Reinventing ourselves: How innovations such as on-line ‘just-in-time’ CME may help bring about a genuinely evidence-based clinical practice. Medical Journal of Australia 2000;173:343-344), echoing Lawrence Weed, “Clinicians in the past were trained to master clinical knowledge and become experts in knowing why and how. Today’s clinicians have no hope of mastering any substantial portion of the medical knowledge base.  Every time we make a clinical decision, we should stop to consider whether we need to access the clinical evidence-base. Sometimes that will be in the form of on-line guidelines, systematic reviews or the primary clinical literature.”

Fig 1

Interoperability across environments

Define representation for storage that is independent of  implementation

Define a representation of collection that is independent of the database – schema, table structures

Informatics and the Education of Laboratory Professionals

The increasing dependence on laboratory information and the incorporation of laboratory information into Evidence-Based Guidelines necessitates a significant component of education in informatics.   The public health service has mandated informatics as a component of competencies for health services professionals (“Core Competencies for Public Health Professionals” compendium developed by the Council on Linkages Between Academia and Public Health Practice.), and nursing informatics competencies have already been written.   Coiera (E. Coiera, Medical informatics meets medical education: There’s more to understanding information than technology, Medical Journal of Australia 1998; 168: 319-320) has suggested 10 essential informatics skills for physicians.

I have put together a list below with items taken from Coiera and the Public Health Service competencies for elaboration of competencies for Clinical Laboratory Sciences.
A.   Personal Maintenance
1.   Understands the dynamic and uncertain nature of medical knowledge and know how to keep personal knowledge and skills up-to-date

  1.  Searches for and assesses knowledge according to the statistical basis of scientific evidence
  2. Understands some of the logical and statistical models of the diagnostic process
  3. Interprets uncertain clinical data and deals with artefact and error
  4. Evaluates clinical outcomes in terms of risks and benefits

B.   Effective Use of Information

Analytic Assessment Skills

  1. Identifies and retrieves current relevant scientific evidence
  2. Identifies the limitations of research
  3. Determines appropriate uses and limitations of both quantitative and qualitative data

9.  Evaluates the integrity and comparability of data and identifies gaps in data sources

10.  Applies ethical principles to the collection, maintenance, use, and dissemination of data and information
11.  Makes relevant inferences from quantitative and qualitative data
12.  Applies data collection processes, information technology applications, and computer systems storage/retrieval strategies

13.  Manages information systems for collection, retrieval, and use of data for decision-making
14.  Conducts cost-effectiveness, cost-benefit, and cost utility analyses

  1. Effective Use of Information Technology
  1.  Select and utilize the most appropriate communication method for a given task (eg, face-to-face conversation, telephone, e-mail, video, voice-mail, letter)
  2.  Structure and communicate messages in a manner most suited to the recipient, task and chosen communication medium.

17.  Utilizes personal computers and other office information technologies for working with documents and other computerized files

  1.  Utilizes modern information technology tools for the full range of electronic communication appropriate to one’s duties and programmatic area.
  2. Utilizes information technology so as to ensure the integrity and protection of electronic files and computer systems
  1.  Applies all relevant procedures (policies) and technical means (security) to ensure that confidential information is appropriately protected.

I expand on these recommended standards.   The first item is personal maintenance.   This requires continued education to meet the changing needs of the profession in expanding knowledge and access to knowledge that requires critical evaluation.   The payment for the profession has been paid for recognizing the technical contributions made by the laboratory profession as a task oriented contribution, but not for a contribution as a knowledge worker.   This can be changed, but it can’t be realized through the usual bacchalaureate educated requirement.   Most technologists want to get out in the workforce, but after they are out in the workforce – what next?   In many institutions, it falls back on the laboratory to provide the expertise to drive the organization in the computer and information restructuring, from staff taken from the transfusion service, microbiology, and elsewhere.   The laboratory is recognized for an information expertise, but then there is still reason to do more.   The fact is that the mind set of the laboratory staff has been in a manufacturing productivity related to test production, but the data that the production represents is information.   We have the quality control of the test process, but we are required to manage the total process, including the quality of the information we generate.   Another consideration is that the information we generate is used for clinical trials, and a huge variation in the way the information is used is problematic.

The first category for discussion is personal maintenance.  These items are keeping up with knowledge about advances in medical knowledge,  being critical about the quality of the evidence for current knowledge, and being aware of the statistical underpinnings for that thinking (1-5).   It is not enough to keep up with changes in medical thinking using only the professional laboratory literature. A systematic review of problem topics using PubMed as a guide is also essential.  This requires that the clinical laboratory scientist will have to know how to access the internet and search for key studies concerning the questions that are being asked.   The reading of abstracts and papers also requires an education in methods of statistical analysis, contingency tables, study design, and critical thinking.   The most common methods used in clinical laboratory evaluation are linear regression, linear regression, and yes, linear regression.  A discussion over distance learning among members of the American Statistical Association reveals that much of statistical education for the biologists, chemists, and engineers now comes from *software*.  Knowledge workers in drug development and in molecular diagnostics are increasingly challenged with larger, more complicated data sets, and there is a need to interpret and report results quickly. This need is not confined to basic research or the clinical setting, and it may have to be done without consulting with statisticians.  Category A slides into category B, effective use of information.

Effective use of information requires skills that support the design of evaluations of laboratory tests, methods of statistical analysis, and the critical assessment of published work (6-9), and the processes for collecting data, using information technology application, and interpreting the data (10-12).   Items 13 and 14 address management issues.

There is a vocabulary that has to be mastered and certain questions that have to be answered whenever a topic is being investigated.   I identify a number of these at this point in the discussion.

Contingency Table:  A table of frequencies, usually two-way, with event type in columns and test results as positive or negative in rows.   A multi-way table can be used for multivalued categorical analysis.   The conventional 2X2 contingency table is shown below –

No disease Disease
Test negative A  (TN) B  (FN) A+B

PVN =

TN/(FN+TN)Test positiveC  (FP)D  (TP)C+D

PVP =

TP/(TP+FP) A+C

Specificity=
TN/(FP+TN)B+C

Sensitivity =
TP/(TP+FN)A+B+C+D

Type I error:  There is no finding when one actually exists (missed diagnosis)(false negative error).

Type II error:  There is a finding when none exists (false positive error).

Sensitivity:  Percentage of true positive results.  D/(B + D)

Specificity:  Percentage of true negative results. A/(A + C)

False positive error rate:  The percentage of results that are positive in the absence of disease (1 – specificity).  C/(A + C)

ROC curve:  Receiver operator characteristic curve is plot of sensitivity vs I-specificity.  Two methods can be compared in ROC analysis by the area under the curve.   The optimum decision point can be identified as within a narrow range of coordinates on the curve.

Predictive value (+)(PVP):  Probability there is disease when a test is positive (D/C + D), or percentage of patients with disease, given a positive test.   The observed and expected probability may be the same or different.

Predictive value (-)(PVN):  Probability of absence of disease given a negative test result (A/A + B), or percentage of patients without disease given a negative test.  The observed and expected probability may be the same or different.

Power:   When a statement is made that there is no effect, or a test fails to predict the finding of disease, are there enough patients included in the study to see the effect if it exists.   This applies to randomized controlled drug studies as well as studies of tests. Power protects against the error of finding no effect when it exists.

Selection Bias:  It is common to find a high performance claimed for a test that is not later substantiated when it is introduced and widely used.   Why does this occur?   A common practice in experimental design is to define inclusion criteria and exclusion criteria so that the effect is very specific for the condition and to eliminate the interference by “confounders”, unanticipated effects that are not intended.   A common example of this is the removal of patients with acute renal failure and chronic renal insufficiency because of delayed clearance of analytes from the circulation.   The result is that the test is introduced into a population different than the trial population with claims  based on the performance in a limited population.   The error introduced could be prediction of disease in an individual in whom the effect is not true.   This error is reduced by elimination of selection bias, which may require multiple studies using patients who have the confounding conditions (renal insufficiency, myxedema).   Unanticipated effects often aren’t designed into a study.   In many studies about cardiac markers, the study design included only patients who had Acute Coronary Syndrome (ACS)  This is an example of selection bias.   Patients who have ACS  have chest pain of anginal nature that lasts at least 30 minutes, and usually have more than a single episode in 24 hours.   That is not how a majority of patients present to the emergency department who are suspected of having a myocardial infarct.   How then is one to evaluate the effectiveness of a cardiac marker?

Randomization:   Randomization is the assignment of the treatment group to either placebo (no treatment) or treatment.   The investigator and the participant enrolled in the study are blinded.   The analyst might also be blinded.   A potential problem is selection bias from dropouts who skew the characteristics of the population.

Critical questions:

What is the design of the study that you are reading?   Is there sufficient power or is there selection bias?  What are the conclusions of the authors?   Are the conclusions in line with the study design, or overstated?

Statistical tests and terms:   

Normal distribution:  Symmetrical bell shaped curve (Gaussian distribution).   The 2 standard deviation limits is approximately the 95% confidence interval.

Chi square test:  Has a chi square distribution.   Used for measuring probability from a contingency table.   Non-parametric test.

Student’s t-test:  Parametric measure of difference between two population means.

F-test:  An F-test ( Snedecor and Cochran, 1983) is used to test if the standard deviations of two populations are equal.  In comparing two independent samples of size N1 and N2 the F Test provides a measure for the probability that they have the same variance. The estimators of the variance are s12 and s22. We define as test statistic their ratio T = s12/ s22, which follows an F Distribution with f1= N1-1 and f2= N2-1 degrees of freedom.

F Distribution: The F distribution is the ratio of two chi-square distributions with degrees of freedom and , respectively, where each chi-square has first been divided by its degrees of freedom.

Z scores:  Z scores are sometimes called “standard scores”. The z score transformation is especially useful when seeking to compare the relative standings of items from distributions with different means and/or different standard deviations.

Analysis of variance:  Parametric measure of two or more population means by the comparison of variances between the populations.   Probability is measured by the F-test.

Linear Regression:  A classic statistical problem is to try to determine the relationship between two random variables  X and Y. For example, we might consider height and weight of a sample of adults.  Linear regression attempts to explain this relationship with a straight line fit to the data.  The simplest case of regression — one dependent and one independent variable — one can visualize in a scatterplot, is simple linear regression (see below).   The linear regression model is the most commonly used model in Clinical Chemistry.

Multiple Regression:  The general purpose of multiple regression (the term was first used by Pearson, 1908) is to learn more about the relationship between several independent or predictor variables and a dependent or criterion variable.  The general computational problem that needs to be solved in multiple regression analysis is to fit a straight line to a number of points.  A multiple regression fits a line using two or more predictors to the dependent variable by a model — Y = a1X1 + a2X + b + g.

Discriminant function:  Discriminant analysis is a technique for classifying a set of observations into predefined classes. The purpose is to determine the class of an observation based on a set of variables known as predictors or input variables. The model is built based on a set of observations for which the classes are known. This set of observations is sometimes referred to as the training set. Based on the training set , the technique constructs a set of linear functions of the predictors, known as discriminant functions, such that

L = b1x1 + b2x2 + … + bnxn + c , where the b’s are discriminant coefficients, the x’s are the input variables or predictors and c is a constant.

These discriminant functions are used to predict the class of a new observation with unknown class. For a k class problem k discriminant functions are constructed. Given a new observation, all the k discriminant functions are evaluated and the observation is assigned to class i if the ith discriminant function has the highest value.

Nonparametric Methods:

Logistic Regression: Researchers often want to analyze whether some event occurred or not.  The outcome is binary.  Logistic regression is a type of regression analysis where the dependent variable is a dummy variable (coded 0, 1).   The linear probability model, expressed as Y = a + bX + e, is problematic because

  1. The variance of the dependent variable is dependent on the values of the independent variables.
  2. e, the error term, is not normally distributed.
  3. The predicted probabilities can be greater than 1 or less than 0.

The “logit” model has the form:

ln[p/(1-p)] = a + BX + e or

[p/(1-p)] = expa expBX expe

where:

  • ln is the natural logarithm, logexp, where exp=2.71828…
  • p is the probability that the event Y occurs, p(Y=1)
  • p/(1-p) is the “odds ratio”
  • ln[p/(1-p)] is the log odds ratio, or “logit”

The logistic regression model is simply a non-linear transformation of the linear regression. The logit distribution constrains the estimated probabilities to lie between 0 and 1.

Graphical Ordinal Logit Regression:  The logistic regression fits a non-parametric solution to a two-valued event.   The outcome in question might have 3 or more values.

For example, scaled values of a test – low, normal, and high – might have different meanings.   This type of behavior occurs in certain classification problems.  For example, the model has to deal with anemia, normal, and polycythemia, or similarly, neutropenia, normal, and systemic inflammatory response (sepsis).   This model fits the data quite readily.

Clustering methods:  There are a number of methods to classify data when the dependent variable is not known, but is presumed to exist.   A commonly used method classifies data using geometric distance of the average point coordinates.   A very powerful method used is Latent Class Cluster analysis.

Data Extraction:

Data can be extracted from databases, but have to be worked at in a flat file format.   The easiest and most commonly used methods are to collect data in a relational database, such as Access (if the format is predefined), or the convert data into an Excel format.   A common problem is the inability to extract certain data because it is not in an extractable or usable format.

Let us examine how these methods are actually used in a clinical laboratory setting.

The first example is a test introduced almost 30 years ago into quality control in hematology by Brian Bull at Loma LindaUniversity called the x-bar function (also the Bull algorithm).   The method looks at the means of runs of the population data on the assumption the means of the MCV don’t vary for a stable population from day-to-day.  This is a very useful method that can be applied to the evaluation of laboratory.   It is a standard quality control program used in industrial processes since the 1930s.

We next examine the Chi Square distribution.  Review the formula for calculating chi square and calculations of expected frequencies.  Take a two-by-two table of the type

Effect               No effect          Sum Column

Predictor positive          87                     12                     99

Predictor negative         18                     93                    111

Sum Rows                    105                   105                   210

Experiment with the recalculation of chi square by changing the frequencies in the columns for effect and no effect, keeping the total frequencies the same.  The result is a decrease in the chi square as predictor negative – effect and predictor positive – no effect both increase.  The exercise can be carried out on the chi square calculator using Google to find the site.   The chi square can be used to test the contingency table that is used to indicate the effectiveness of fetal fibronectin for assessing low risk of preterm delivery.

For example,

No Preterm Labor Yes Preterm Labor Sum Row
FFN – neg

99

1

100

FFN – pos

35

65

100

Sum Column

134

66

200

PVN = 100*(1/100)% = 99%

99% observed probability that there will not be preterm delivery with a negative test.

Chi square goodness of fit:

Degrees of freedom: 1
Chi-square = 92.6277702397105
p is less than or equal to 0.001.
The distribution is significant.

Examine the effects of scaling of continuous data from a heart attack study to obtain ordered intervals.  Look at the chi square test for the heart attack test by a Nx2 table with the table columns as heart attack or no heart attack.  This allowed us to determine the significance of the test in predicting heart attack.   Look at the Student T test for comparing the continuous values of the test between the heart attack and non-heart attack population.  The T test is like the one-way analysis of variance with only two values for the factor variable.  The T test and ANOVA1 compares the means between two populations.  If the result is significant, then the null hypothesis that the data is taken from the same population is rejected.  The alternative hypothesis is that they are different.

One can visualize the difference by plotting the means and confidence intervals for the two groups.

One can visualize the difference by plotting the means and confidence intervals for the two groups.

We can plot a frequency distribution before we calculate the means and check the distribution around the means.   The simplest way to do this is the histogram.   The histogram for a large sample of potassium values is used to illustrate this.   The mean is 4.2.

We can use a method for quality control called the X-bar (Beckman Coulter has it on the hematology analyzer) to test the deviation from the means of runs.   I illustrate the validity of the X-bar by comparing the means of a series of runs.

Sample size                   =       958

Lowest value                  =        84.0000

Highest value                 =        90.7000

Arithmetic mean               =        87.8058

Median                        =        87.8000

Standard deviation            =         0.9362

————————————————————

Kolmogorov-Smirnov test

for Normal distribution       :   accept Normality (P=0.353)

If I compare the means by the T-test, I am testing whether the sampling is taken from the same or different populations.   When we introduce a third group, then we are asking whether the sampling is taken from a single population or to reject the hypothesis, taking the alternative hypothesis that the samples are different.   This is illustrated by sampling from a group of patients with no cardiac disease and normal, neither of which have acute myocardial infarction.   This is illustrated below:

Two-sample t-test on CKMB grouped by OTHER against Alternative = ‘not equal’

      Group N Mean SD
   0          660       1.396       3.085
   1          90       4.366       4.976

Separate variance:

t                         =       -5.518

df                        =         98.5

p-value                   =        0.000

Bonferroni adj p-value    =        0.000

Pooled variance:

t                         =       -7.851

df                        =          748

p-value                   =        0.000

Bonferroni adj p-value    =        0.000

Two-sample t-test on TROP grouped by OTHER against Alternative = ‘not equal’

      Group N Mean SD
   0          661       0.065       0.444
   1          90       1.072       3.833

Separate variance:

t                         =       -2.489

df                        =         89.3

p-value                   =        0.015

Bonferroni adj p-value    =        0.029

Pooled variance:

t                         =       -6.465

df                        =          749

p-value                   =        0.000

Bonferroni adj p-value    =        0.000

Another example illustrates the application of this significance test.   Beta thalassemia is characterized by an increase in hemoglobin A2.   Thalassemia gets more complicated when we consider delta beta deletion and alpha thalassemia.   Nevertheless, we measure the hemoglobin A2 by liquid chromatography on the Biorad Variant II.   The comparison of hemoglobin A2 in affected and unaffected is shown below (with random resampling):

Two-sample t-test on A2 grouped by THALASSEMIA DIAGNOSIS against Alternative = ‘not equal’

      Group N Mean SD
   0          257       3.250       1.131
   1          61       6.305       2.541

Separate variance:

t                         =       -9.177

df                        =         65.7

p-value                   =        0.000

Bonferroni adj p-value    =        0.000

Pooled variance:

t                         =      -14.263

df                        =          316

p-value                   =        0.000

Bonferroni adj p-value    =        0.000

When we do a paired comparison of the Variant hemoglobin A2 versus quantitation of Helena isoelectric focusing, the results with the T-test shows no significance.

Paired samples t-test on A2 vs A2E with 130 cases

Alternative = ‘not equal’

Mean A2                   =        3.638

Mean A2E                  =        3.453

Mean difference           =        0.185

SD of difference          =        1.960

t                         =        1.074

df                        =          129

p-value                   =        0.285

Bonferroni adj p-value    =        0.285

Consider overlay box plots of the troponin I means for normal, stable cardiac patients and AMI patients:

The means between two subgroups may be close and the confidence intervals around the means may be wide so that it is not clear whether to accept or reject the null hypothesis.  I illustrate this by taking for comparison the two groups that feature normal cardiac status and stable cardiac disease, neither having myocardial infarction.   I use the nonparametric Kruskal Wallis analysis of ranks between two groups, and I increase the sample size to 100,000 patients by a resampling algorithm.   The result for CKMB and for troponin I is:

Kruskal-Wallis One-Way Analysis of Variance for 93538 cases

Dependent variable is CKMB

Grouping variable is OTHER

Group       Count   Rank Sum

0                     83405            3.64937E+09

1                    10133             7.25351E+08

Mann-Whitney U test statistic =  1.71136E+08

Probability is        0.000

Chi-square approximation =     9619.624 with 1 df

Kruskal-Wallis One-Way Analysis of Variance for 93676 cases

Dependent variable is TROP

Grouping variable is OTHER

Group       Count   Rank Sum

0                    83543             3.59446E+09

1                    10133             7.93180E+08

Mann-Whitney U test statistic =  1.04705E+08

Probability is        0.000

Chi-square approximation =    21850.251 with 1 df

Examine a unique data set in which a test is done on amniotic fluid to determine whether there is adequate surfactant activity so that fetal lung compliance is good at delivery.  If there is inadequate surfactant activity there is risk of respiratory distress of the newborn soon after delivery.  The data includes the measure of surfactant activity, gestational age, and fetal status at delivery.  This study emphasized the calculation of the odds-ratio and probability of RDA using surfactant measurement with, and without gestational age for infants delivered within 72 hours of the test.  The statistical method (Goldmine) has a graphical display with the factor variable as the abscissa and the scaled predictor and odds-ratio as the ordinate.  The data acquisition required a multicenter study of the National Academy of Clinical Biochemistry led by John Chapman (Chapel Hill, NC) and Lawrence Kaplan (Bellevue Hospital, NY, NY), published in Clin Chimica Acta (2002).

The table generated is as follows:

Probability and Odds-Ratios for Regression of S/A on Respiratory Outcomes

S/A interval Probability of RDS Odds Ratio
0 – 10  0.87  713
11 – 20  0.69  239
21 – 34  0.43  80
35 – 44  0.20  27
45 – 54  0.08 9
55 – 70  0.03 3
> 70 0.01 1

There is a plot corresponding to the table above.  It is patented as GOLDminer (graphical ordinal logit display).  As the risk increases, the odds-ratio (and probability of an event)  increases.  The calculation is an advantage when there is more than two values of the factor variable, such as, heart attack, not heart attack, and something else.  We  look at the use of the Goldminer algorithm, this time using the acute myocardial infarction and troponin T example.   The ECG finding is scaled so that the result is normal (0), NSSTT (1), ST depression or t-wave inversion, ST elevation.   The troponin T is scaled to: 0.03, 0.031-0.06, 0.061-0.085, 0.086-0.1, 0.11-0.2, > 0.20 ug/L.   The Goldminer plot is shown below with troponin T as 2nd predictor.

(Joint Y)                                   DXSCALE

average            0                      4

X-profile          score                1.00                 0.00

4,5                   3.64                 0.00                 0.68

4,4                   3.51                 0.00                 0.59

4,3                   3.35                 0.00                 0.48

3,5                   3.07                 0.01                 0.34

4,1                   2.87                 0.02                 0.27

3,4                   2.79                 0.02                 0.24

4,0                   2.54                 0.04                 0.17

3,3                   2.43                 0.06                 0.15

3,2                   2.00                 0.12                 0.08

2,5                   1.88                 0.15                 0.07

3,1                   1.55                 0.23                 0.04

2,4                   1.42                 0.26                 0.03

3,0                   1.12                 0.36                 0.01

2,3                   1.02                 0.40                 0.01

2,2                   0.70                 0.53                 0.00

2,1                   0.47                 0.65                 0.00

2,0                   0.32                 0.74                 0.00

1,3                   0.29                 0.77                 0.00

1,2                   0.20                 0.83                 0.00

1,1                   0.13                 0.88                 0.00

1,0                   0.09                 0.91                 0.00

The table is the table of probabilities from the Goldminer program.   The diagnosis scale 4 is MI.   Diagnosis 0 is baseline normal.

We return to a comparison of CKMB and troponin I.   CKMB may be used as a surrogate test for examining the use of troponin I.   We scale the CKMB to 3 and the troponin to 6 intervals.   We construct a 3-by-6 table shown below, with the chi square analysis.

Frequencies

TNISCALE (rows) by CKMBSCALE (columns)

0 1 2 Total
         0          709          12          9          730
         1          14          0          2          16
         2          3          0          0          3
         3          2          0          0          2
         4          4          0          0          4
         5          22          5          17          44
Total          754          17          28          799

Expected values

TNISCALE (rows) by CKMBSCALE (columns)

0 1 2
   0             688.886             15.532             25.582
   1             15.099             0.340             0.561
   2             2.831             0.064             0.105
   3             1.887             0.043             0.070
   4             3.775             0.085             0.140
   5             41.522             0.936             1.542
Test statistic Value df Prob
Pearson Chi-square             198.580             10.000             0.000

How do we select the best value for a test?  The standard accepted method is a ROC plot.  We have seen how to calculate sensitivity, specificity, and error rates.  The false positive error is 1 – specificity.  The ROC curve plots sensitivity vs 1 – specificity.  The ROC plot requires determination of the “disease” variable by some means other than the test that is being evaluated.   What if the true diagnosis is not accurately known?   The question posed introduces the concept of Latent Class Models.

 

A special nutritional study set was used in which the definition of the effect is not as clear as that for heart attack.  The risk of malnutrition is assessed at the bedside by a dietitian using observed features (presence of wound, malnutrition related condition, and poor oral intake), and by laboratory tests, using serum albumin (protein), red cell hemoglobin, and lymphocyte count.  The composite score was a value of 1 to 4.  Data was collected by Linda Brugler, RD, MBA, at St.FrancisHospital, (Wilmington, DE) on 62 patients to determine whether a better model could be developed using new predictors.

The new predictors were laboratory tests not used in the definition of the risk level, which could be problematic.  The tests albumin, lymphocyte count, and hemoglobin were expected to be highly correlated with the risk level because they were used in its definition.  The prealbumin, but not retinol binding protein or C reactive protein, was correlated with risk score and improved the prediction model.

The crosstable for risk level versus albumin is significant at p < 0.0001.

  A GOLDminer plot showed scaled prealbumin versus levels 3 & 4.    A value less than 5 is severe malnutrition and over 19 is not malnourished.  Mild and moderate malnutrition are between these values.

A method called latent class cluster analysis is used to classify the data.   A latent class is identified when the classification isn’t accurately known.   The result of the analysis is shown in Table 4.   The percent of variable subclasses are shown within each class and total 1.00 (100%).

Cluster1           Cluster2           Cluster3

Cluster Size

0.5545             0.3304             0.1151

PAB1COD

1          0.6841             0.0383             0.0454

2          0.3134             0.6346             0.6662

3          0.0024             0.1781             0.1656

4          0.0001             0.1490             0.1227

ALB0COD

1          0.9491             0.4865             0.1013

2          0.0389             0.1445             0.0869

3          0.0117             0.3167             0.5497

4          0.0003             0.0523             0.2621

LCCOD

1          0.1229             0.0097             0.7600

2          0.3680             0.0687             0.2381

4          0.2297             0.2383             0.0016

5          0.2793             0.6832             0.0002

There are other aspects of informatics that are essential for educational design of the laboratory professional of the future.  These include preparation of powerpoint presentations, use of the internet to obtain current information, quality control designed into the process of handling laboratory testing, evaluating data from different correlated workstations, and instrument integration.   The integrated open architecture will be essential for financial management of the laboratory as well. The continued improvement of the technology base of the laboratory will become routine over the next few years.   The education of the CLS for a professional career in medical technology will require an individual who is adaptive and well prepared for a changing technology environment.   The next section of this document will describe the information structure needed just to carry out the day-to-day operations of the laboratory.

Cost linkages important to define value

Traditional accounting methods do not take into account the cost relationships that are essential for economic survival in a competitive environment so that the only items on the ledger are materials and supplies, labor and benefits, and indirect costs.   This is a description of the business as set forth by an NCCLS cost manual, but it is not sufficient to account for the dimensions of the business in relationship to its activities.   The emergence of spreadsheets, and even as importantly, the development of relational database structures, has transformed and is transforming how we can look at the costing of organizations in relationship to how individuals and groups within the organization carry out the business plan and realize the mission set forth by the governing body.   In this sense, the traditional model was incomplete because it only accounted for the costs incurred by departments in a structure that allocates resources to each department based on the assessed use of resources in providing services.   The model has to account for the allocation of resources to product lines of services (as a DRG model developed by Dr. Eleanor Travers).   A revised model has to take into account two new dimensions.   The first dimension is that of the allocation of resources to provide services that are distinct medical/clinical activities.   This means that in the laboratory service business there may be distinctive services as well as market sectors.   That is, health care organizations view their markets as defined by service Zip codes which delineate the lines drawn between their market and the competition (in the absence of clear overlap).

We have to keep in mind that there are service groups that were defined by John Thompson and Robert Fetter in the development of the DRGs (Diagnosis Related Groups) that have a real relationship to resource requirements for pediatric, geriatric, obstetrics, gynecology, hematology, oncology, cardiology, medical and surgical.   These groups are derived from bundles of ICDs (International Code of Diagnosis) that have comparable within group use of laboratory, radiology, nutrition, pharmacy and other resources.   There was an early concern that there was too much variability within DRGs, which was addressed by severity of illness adjustment (Susan Horn).   It is now clear that ICD’s don’t capture a significant content of the medical record. A method is being devised to correct this problem by Kaiser and Mayo using the SNOMED codes as a starting point.   The point is that it is essential that the activities, resources required, and payment be aligned for validity of the payment system.   Of some interest is the association of severity of illness with more than two comorbidities, and of an association with critical values of a few laboratory tests, e.g., albumin, sodium, potassium, hemoglobin, white cell count.   The actual linkages of these resources to cost of the ten or 20 most common diagnostic categories is only a recent event.   As a rule the top 25 categories account for a substantial volume of the costs that it is of great interest to control.   The improvement of database technology makes it conceivable that 100 categories of disease classification could be controlled without difficulty in the next ten years.

Quality cost synergism

What is traditionally described is only one dimension of the business of the operation.   It is the business of the organization, but it is only one-third of the description of the organization and the costs that drive it.   The second dimension of the organization’s cost profile is only obtained by cost accounting how the organization creates value.   Value is simply the ratio of outputs to inputs.   The traditional cost accounting model looks only at business value added.   The value generated by an organization is attributable to a service or good produced that a customer is willing to purchase.   We have to measure the value by measuring some variable that is highly correlated with the value created.   That measure is partly accounted for by transaction times.  We can borrow from the same model that is used in other industries.   The transportation business is an example.   A colleague has designed a surgical pathology information system on the premise that a report in the pathology office or a phone inquiry by a surgeon is a failure of the service.   This is analogous to the Southeast Airlines mission to have the lowest time on the ground in the industry.   The growing complexity of service needs, the capital requirements to support the needs, and the contractual requirements are driving redesign of services in a constantly changing environment.

 

Technology requirements

We have gone from predominantly batch and large scale production to predominantly random access and a growing point-of-care application with pneumatic tube delivery systems in the acute care setting in the last 15 years.   The emphasis on population-based health and increasing shift from acute care to ambulatory care has increased the pressure for point-of-care testing to reduce second visits for adjustment of medication.   The laboratory, radiology and imaging services, and pharmacy information have to be directed to a medical record that may be accessed in acute care or ambulatory setting.   We not only have the proposition that faster is better, but access is from anyplace and almost anytime – connectivity.

There has been a strategic discussion about configuration of information services that is resolving itself by the needs of the marketplace.   Large, self contained organizations are short-lived, and with the emergence of networked provider organizations there will be no compelling interest in having systems that are not tailored to the variety of applications and environments that are served.   The migration from minicomputer to microcomputer client-server networks will go rapidly to N-tiered systems with distributed object-oriented features.   The need for laboratory information systems as a separate application can be seriously challenged by the new paradigm.

 

Utilization and Cost Linkages

Laboratory utilization has to be looked at from more than one perspective in relationship to costs and revenues.   The redefinition of panels cuts the marginal added cost to produce an additional test, but it doesn’t cut the largest cost in obtaining and processing the specimen.   Unfortunately, there is a fixed cost of the operations that has to be achieved, which also drives the formation of laboratory consolidations to have sufficient volume.    If one looks at the capital requirements and labor to support a minimum volume of testing, the marginal cost of added tests decreases with large volume.   The problem with the consolidation argument is that one has to remove testing from the local site in order to increase the volume with an anticipated effect on cycle time for processing.   There is also a significant resource cost for courier service, specimen handling and reporting.   Lets look at the reverse.   What is the effect of decreasing utilization?   One increases the marginal added cost per unit of testing on specimens or accessions.   There is the same basic fixed cost, and if the volume of testing needed to break even is met, the advantage of additional volume is lost.   Fixing the expected cost per patient or per accession becomes problematic if there is a requirement to reduce utilization.

The key volume for processing in the service sense is the number of specimens processed, which has an enormous impact on the processing requirements (number of tests adds to reagent costs and turnaround time per accession).   The result is that one might consider the reduction of testing that is done to monitor critical patients’ status more frequently than is needed.   One can examine the frequency of the CBC, PT/APTT, panels, electrolytes, glucose, and blood gases in the ICUs.   The use of the laboratory is expected to be more intense, reflecting severity of illness, in this setting.   On the other hand, excess redundancy may reflect testing that makes no meaningful contribution to patient care.   This may be suggested by repeated testing with no significant variation in the lab results.

Intangible elements

Competitive advantage may have marginal costs with enormous value enhancement.   This is in the manner of reporting the results.   My colleagues have proposed the importance of a scale-free representation of the laboratory data for presentation to the provider and the patients.   This can be extended further by the scaling of the normalized data into intervals associated with expected risks for outcomes.   This would move the laboratory into the domain of assisting in the management of population adjusted health outcomes.

Blume P. Design of a clinical laboratory computer system. Laboratory and  Hospital Information Systems. In Clinics Lab Med 1991;11:83-104.

Didner RS. Back-to-front systems design: a guns and butter approach. Proc Intl Ergonomics Assoc 1982;–

Didner RS, Butler KA. Information requirements for user decision support: designing systems from back to front. Proc Intl Conf on Cybernetics and Society. IEEE. 1982;–:415-419.

Bernstein LH. An LIS is not all pluses. MLO 1986;18:75-80.

Bernstein LH, Sachs B. Selecting an automated chemistry analyzer: cost analysis. Amer Clin Prod Rev 1988;–:16-19.

Bernstein L, Sachs E, Stapleton V, Gorton J. Replacement of a laboratory instrument system based on workflow design. Amer Clin Prod Rev 1988; –: 22-24.

Bernstein LH. Computer-assisted restructuring services. Amer Clin Prod Rev1986;9:–

Bernstein LH, Sachs B, Stapleton V, Gorton J, Lardas O. Implementing a laboratory information management system and verifying its performance. Informatics in Pathol 1986;1:224-233.

Bernstein LH. Selecting a laboratory computer system: the importance of auditing laboratory performance. Amer Clin Prod Rev 1985;–:30-33.

Castaneda-Mendez K, Bernstein LH. Linking costs and quality improvement to clinical outcomes through added value. J Healthcare Qual 1997;19:11-16.

Bernstein LH. The contribution of laboratory information systems to quality assurance. Amer Clin Prod Rev 1987;18:10-15.

Bernstein LH. Predicting the costs of laboratory testing. Pathologist 1985;39:–

Bernstein LH, Davis G, Pelton T. Managing and reducing lab costs. MLO 1984;16:53-56.

Bernstein LH, Brouillette R. The negative impact of untimely data in the diagnosis of acute myocardial infarction. Amer Clin Lab 1990;__:38-40.

Bernstein LH, Spiekerman AM, Qamar A, Babb J. Effective resource management using a clinical and laboratory algorithm for chest pain triage. Clin Lab Management Rev 1996;–:143-152.

Shaw-Stiffel TA, Zarny LA, Pleban WE, Rosman DD, Rudolph RA, Bernstein LH. Effect of nutrition status and other factors on length of hospital stay after major gastrointestinal surgery. Nutrition (Intl) 1993;9:140-145.

Bernstein LH. Relationship of nutritional markers to length of hospital stay. Nutrition (Intl)(suppl) 1995;11:205-209.

Bernstein LH, Coles M, Granata A. The BridgeportHospital experience with autologous transfusion in orthopedic surgery. Orthopedics 1997;20:677-680.

Bernstein LH. Realization of the projected impact of a chemistry workflow management system at BridgeportHospital. In Quality and Statistics: Total Quality Management. Kowalewski MJ, Ed. 1994; 120-133 ASTM: STP 1209. Phila, PA.

Bernstein LH, Kleinman GM, Davis GL, Chiga M. Part A reimbursement: what is your role in medical quality assurance? Pathologist 1986;40:–.

Bernstein LH. What constitutes a laboratory quality monitoring program? Amer J Qual Util Rev 1990;5:95-99.

Mozes B, Easterling J, Sheiner LB, Melmon KL, Kline R, Goldman ES, Brown AN. Case-mix adjustment using objective measures of severity: the case for laboratory data. Health Serv Res 1994;28:689711.

            Bernstein LH, Shaw-Stiffel T, Zarny L, Pleban W. An informational approach to likelihood of malnutrition. Nutr (Intl) 1996;12:772-226.

Read Full Post »

Reporter: Aviva Lev-Ari, PhD, RN

Extreme Performance Athletes May Be at Risk for Cardiac Arrhythmias

http://bidmc.org/CentersandDepartments/Departments/CardiovascularInstitute/CVINewsletter/TooMuchGoodThing.aspx

World-class rowing champion Frederick SchochWorld-class rowing champion Frederick Schoch

You probably know that regular, moderate exercise can result in many health benefits. But you may be surprised to learn that prolonged, intensive endurance exercise on an Olympian scale can actually damage your heart.

Scientists and doctors have demonstrated that long-term training and competition in extreme endurance sports such as marathons, iron-man triathlons, competitive rowing and long-distance bicycle races may cause structural changes to the heart and large arteries.

“Athlete’s heart syndrome” was first described more than 100 years ago as an apparently benign condition in which the elite athlete’s heart enlarges and thickens. For many years, doctors noted that abnormal electrocardiograms were common for extreme athletes, but no evidence pointed to an association with serious arrhythmias or sudden cardiac death. However, there is accumulating evidence that chronic extreme athletic activity may lead to potentially harmful changes in the heart in some individuals.

For example, a review published recently in the Mayo Clinic Proceedingsdemonstrated that approximately 12 percent of apparently healthy marathon runners showed microscopic areas of fibrosis, or scarring, in the heart chambers. The significance of these changes is not clear, but they could predispose the heart to abnormal rhythms in some cases.

A two-year follow-up revealed that the rate of coronary heart disease was significantly higher in extreme marathon runners than in moderate runners.

A 2011 Swedish study showed that elite cross-country skiers with long years of endurance training had a 29 percent higher risk of developing a variety of abnormal heart rhythms, some benign as well as some more serious.

Extreme Athletics and Atrial Fibrillation

High-profile professional athletes who are believed to have died of fatal arrhythmias include NFL star Reggie White, who died at 43 in 2004, and legendary ultra-marathoner Micah True, who died at 58 earlier this year.

Researchers believe high-endurance sports may promote the occurrence of atrial fibrillation in susceptible persons. This arrhythmia, which involves uncomfortable episodes of irregular, rapid heartbeat caused by faulty electrical signals in the heart, is usually not life-threatening. However, in about 5 percent of those with the condition, it can lead to heart failure and stroke.

“Physicians are becoming increasingly aware that extreme training regimens and endurance-style competitions can, in rare instances, lead to potentially dangerous abnormal cardiac rhythms,” says Alfred E. Buxton, MD, Director of the Clinical Electrophysiology Laboratory at Beth Israel Deaconess Medical Center’sCardioVascular Institute.

Physicians need to take into account the current research, follow new developments and be prepared to advise certain patients to make lifestyle changes based on the new data, he says.

One Athlete’s Story

Mark E. Josephson, MDMark E. Josephson, MD

Mark E. Josephson, MD, Chief of Cardiovascular Medicine at the CardioVascular Institute — and an internationally recognized expert in electrophysiology and catheter ablation — has treated numerous rowers and other high-performance athletes who have suffered from atrial fibrillation. One example is Frederick Schoch, a world-class rowing champion and executive director of Boston’s celebrated annual Head of the Charles Regatta.

Schoch was diagnosed with paroxysmal atrial fibrillation in 2009 after he experienced heavy breathing and lightheadness following his crew’s fifth consecutive first-place finish in the Regatta’s 50 and older category. Schoch learned that atrial fibrillation can cause blood clots in the left atrium (upper chamber) and can lead to heart failure and stroke. Treatments may include medications (such as beta-blockers or anti-arrhythmic drugs), interventions (such as catheter ablation) and/or surgery.

To regulate his heart rate, Schoch’s primary care physician prescribed the drug diltiazem, but his episodes persisted and he feared he would never be able to compete again.

“Rowing is in my DNA,” says Schoch, whose father was an Olympic rower. “But with afib, I couldn’t even walk up the stairs.”

In 2010, a fellow rower referred Schoch to Dr. Josephson, who has treated more than 1,000 cardiac arrhythmia patients.

Back in the Boat

After hearing Schoch’s story, Dr. Josephson performed a catheter ablation, an interventional procedure that reduces the frequency of paroxysmal atrial fibrillation symptoms about 70 percent of the time. The procedure typically lasts two hours and involves inserting a catheter through the groin and puncturing the membrane between the heart’s right and left atria. Catheters are placed at the pulmonary veins (which are the source of atrial fibrillation triggers in 90 percent of paroxysmal afib cases), while the cardiologist delivers a high-frequency, low-voltage current to the site. This burns the tissue to isolate the pulmonary vein from the atrius so that triggers can’t initiate atrial fibrillation.

Schoch spent one night at BIDMC and returned to work two days later. He resumed his training, and in 2011, just one year after his procedure, he led his team to their sixth first-place finish in the Regatta’s senior division. Currently, he is serving as a television analyst, commenting on rowing at the 2012 Summer Olympics. He is also training for the next Head of the Charles Regatta in October.

“I am eternally grateful to Dr. Josephson,” says Schoch. “I hope that my experience can be helpful to others.”

Do Not Stop Exercising!

While the findings cited here are unsettling, they shouldn’t discourage anyone from being physically active. For most adults, the American Heart Associationrecommends 150 minutes of moderate exercise a week (30 minutes a day on five days), or 75 minutes per week of vigorous exercise. Exercise is almost as effective when divided into several shorter periods during the day for convenience.

The result will be increased physical capacity and mental well-being, and a significant reduction in cardiovascular disease risk factors such as high blood pressure, excess weight and unhealthy cholesterol levels. Regular exercise helps fend off not only heart disease and stroke, but also many cancers, osteoporosis, diabetes, arthritis and depression.

“Moderate exercise is certainly good for your heart and your overall health,” says Dr. Buxton. “However, as is usually the case in life, moderation should be the guideline. Beyond 30 to 60 minutes per day, you may reach a point of diminishing returns. So don’t overdo it, but take comfort in knowing that with the right diagnosis and treatment, atrial fibrillation can be managed successfully.”

Above content provided by the CardioVascular Institute at Beth Israel Deaconess Medical Center. For advice about your medical care, consult your doctor.

Posted August 2012

Read Full Post »

Reported by: Dr. Venkat S.Karra, Ph.D.

Last August, UPenn scientists announced the dramatic results of a tiny clinical trial of their immunotherapy approach, describing long-lasting remissions in leukaemia patients for whom standard therapies had stopped working. Trials are also underway for other leukaemias and for lymphoma, mesothelioma, myeloma and neuroblastoma, according to the university.

The therapy developed by UPenn’s Carl June is complicated. Vaccines prompt a patient’s immune system to attack dangerous cells through an approach, called chimeric-antigen-receptor immunotherapy – a genetically redesigned immune cells for a more powerful attack. In this therapy first, blood is collected from leukaemia patients and exposed to substances that activate T cells, powerful cells that launch and coordinate immune attacks. Next, the T cells are genetically modified to recognize and attack leukaemia cells. Finally, the altered cells are returned to the patient, where they are expected to proliferate until the cancer cells are gone.

Drug giant Novartis is making a multimillion dollar bet that a patient’s immune system can be cancer’s worst enemy. It is teaming up with scientists at the University of Pennsylvania (UPenn) in Philadelphia to develop and manufacture cancer immunotherapies.

In the US$20-million collaboration, announced today, Novartis, which is based in Basel, Switzerland, will get exclusive worldwide rights to these technologies.

source

http://blogs.nature.com/news/2012/08/novartis-gives-upenn-20-million-for-cancer-vaccine.html?utm_source=feedburner&utm_medium=feed&utm_campaign=Feed%3A+news%2Frss%2Fnewsblog+%28News+Blog+-+Blog+Posts%29&WT.ec_id=NEWS-20120807

 

 

 

Read Full Post »

Reported by: Dr. Venkat S. Karra, Ph.D.

“Comprehensive computer models of entire cells have the potential to advance our understanding of cellular function and, ultimately, to inform new approaches for the diagnosis and treatment of disease.” Not only does the model allow researchers to address questions that aren’t practical to examine otherwise, it represents a stepping-stone towards its use  in bioengineering and medicine.

A team led by Stanford bioengineering Professor Markus Covert used data from more than 900 scientific papers to account for every molecular interaction that takes place in the life cycle of Mycoplasma genitalium. Mycoplasma genitalium is a humble parasitic bacterium, known mainly for showing up uninvited in human urogenital and respiratory tracts. But the pathogen also has the distinction of containing the smallest genome of any free-living organism – only 525 genes, as opposed to the 4,288 of E. coli, a more traditional laboratory bacterium.

“This is potentially the new Human Genome Project,” Karr said who is a co-first author and Stanford biophysics graduate student. “It’s to understand biology generally.”

“It’s going to take a really large community effort to get close to a human model.”

This is a breakthrough effort for computational biology, the world’s first complete computer model of an organism. “This achievement demonstrates a transforming approach to answering questions about fundamental biological processes,” said James M. Anderson, director of the National Institutes of Health Division of Program Coordination, Planning, and Strategic Initiatives.

Study results were published by Stanford researchers in the journal Cell.

The research was partially funded by an NIH Director’s Pioneer Award from the National Institute of Health Common Fund.

Source:

http://www.dddmag.com/news/2012/07/first-complete-computer-model-bacteria?et_cid=2783229&et_rid=45527476&linkid=http%3a%2f%2fwww.dddmag.com%2fnews%2f2012%2f07%2ffirst-complete-computer-model-bacteria

Read Full Post »

Transcatheter Aortic Valve Implantation (TAVI): FDA approves expanded indication for two transcatheter heart valves for patients at intermediate risk for death or complications associated with open-heart surgery

Reporter: Aviva Lev-Ari, PhD, RN

 

UPDATED ON 8/23/2016

FDA approves expanded indication for two transcatheter heart valves for patients at intermediate risk for death or complications associated with open-heart surgery

about a third of patients referred for open-heart surgery for aortic-valve replacement fall into the intermediate-risk category, defined as having at least a 3% risk of death within 30 days of surgery.

http://www.medscape.com/viewarticle/867656?nlid=109007_3866&src=WNL_mdplsfeat_160823_mscpedit_card&uac=93761AJ&spon=2&impID=1183827&faf=1

 

For Immediate Release

August 18, 2016

Release

The U.S. Food and Drug Administration today approved an expanded indication for the Sapien XT and Sapien 3 transcatheter heart valves for patients with aortic valve stenosis who are at intermediate risk for death or complications associated with open-heart surgery. These devices were previously approved only in patients at high or greater risk for death or complications during surgery.

“This is the first time in the U.S. that a transcatheter aortic valve has been approved for use in intermediate risk patients,” said Bram Zuckerman, M.D., director of the division of cardiovascular devices at the FDA’s Center for Devices and Radiological Health. “This new approval significantly expands the number of patients indicated for this less invasive procedure for aortic valve replacement.”

Aortic valve stenosis increases with age as the aortic valve becomes narrow, causing the heart to work harder to pump enough blood through a smaller opening. It occurs in about three percent of Americans over age 75 and can cause fainting, chest pain, heart failure, irregular heart rhythms (arrhythmias), cardiac arrest or death. Patients with severe aortic valve stenosis generally need to have a heart valve replacement to improve blood flow through their aortic valve.

Traditionally, open-heart surgery has been the gold standard for aortic valve replacement in intermediate risk patients, but it involves a larger incision and longer recovery time than the minimally invasive procedure used to insert the transcatheter heart valve. About one-third of patients referred for open-heart surgery for aortic valve replacement fall into the “intermediate risk” category, which is defined as having a greater than three percent risk of dying within 30 days following surgery.

In a clinical study to evaluate safety and effectiveness, 1,011 aortic stenosis patients at intermediate risk for surgical complications were randomly selected to have a transcatheter aortic valve replacement procedure using the Sapien XT valve and 1,021 were randomly selected to have a traditional aortic valve replacement during open-heart surgery using a surgical tissue valve. In a second study, 1,078 intermediate risk patients were implanted with the Sapien 3 valve; and outcomes in these patients were compared to the same group of 1,021 surgical control patients in the first study. The two studies demonstrated a reasonable assurance of safety and effectiveness of the Sapien XT and Sapien 3 devices in intermediate risk patients.

Patients who receive either the Sapien XT or the Sapien 3 valve face a potential risk of serious complications from the device or implantation procedure, such as death, stroke, acute kidney injury, heart attack, bleeding, and the need for a permanent pacemaker.

The devices are contraindicated for patients who cannot tolerate blood thinning medication. They are also contraindicated for those who are currently being treated for a bacterial or other infection.

As part of the approval of these devices, the FDA is requiring the manufacturer to conduct a post-approval study to follow the patients treated with either device in the first and second clinical studies for 10 years to further monitor safety and effectiveness.

Sapien XT and Sapien 3 are manufactured by Edwards Lifesciences, LLC, based in Irvine, California.

The FDA, an agency within the U.S. Department of Health and Human Services, protects the public health by assuring the safety, effectiveness, and security of human and veterinary drugs, vaccines and other biological products for human use, and medical devices. The agency also is responsible for the safety and security of our nation’s food supply, cosmetics, dietary supplements, products that give off electronic radiation, and for regulating tobacco products.

 
8/2/2012

Transcatheter Aortic Valve Implantation (TAVI): Risky  and Costly

On this Scientific Web Site, Frontiers in Cardiology and Cardiac Repair are reported as discovered and debated in the literature. Our address of the innovations involving the development of TAVI are reported as follows:

June 4, 2012 — Investigational Devices: Edwards Sapien Transcatheter Aortic Valve Transapical Deployment http://pharmaceuticalintelligence.com/2012/06/04/investigational-devices-edwards-sapien-transcatheter-heart-valve/

June 10, 2012 — Investigational Devices: Edwards Sapien Transcatheter Aortic Heart Valve Replacement Transfemoral Deployment http://pharmaceuticalintelligence.com/2012/06/10/investigational-devices-edwards-sapien-transcatheter-aortic-heart-valve-replacement-transfemoral-deployment/

June 19, 2012 — Executive Compensation and Comparator Group Definition in the Cardiac and Vascular Medical Devices Sector: A Bright Future for Edwards Lifesciences Corporation in the Transcatheter Heart Valve Replacement Market http://pharmaceuticalintelligence.com/2012/06/19/executive-compensation-and-comparator-group-definition-in-the-cardiac-and-vascular-medical-devices-sector-a-bright-future-for-edwards-lifesciences-corporation-in-the-transcatheter-heart-valve-replace/

Our reporting on Regulatory Affairs for Medical Devices was reported on 7/31/2012.

July 31, 2012 — Gaps, Tensions, and Conflicts in the FDA Approval Process: Implications for Clinical Practice http://pharmaceuticalintelligence.com/2012/07/31/gaps-tensions-and-conflicts-in-the-fda-approval-process-implications-for-clinical-practice/

 

On August 1, 2012, in BJM researchers at  KCE, Belgian Health Care Knowledge Centre, Administratief Centrum Kruidtuin, Kruidtuinlaan 55, 1000 Brussels, Belgium; 2CEBAM, Belgian Centre for Evidence-Based Medicine and Branch of the Dutch Cochrane Centre, Leuven, Belgium — reported research results which are examining why the practice of TAVI has gone beyond the evidence.

Edwards Lifesciences shares closed down more than 2% yesterday after the British Medical Journal said many procedures using its Sapien heart valve “cannot be justified on medical or cost-effectiveness grounds.”

On August 1, 2012 — Shares of Edwards Lifesciences (NYSE:EW) slid 2.2% yesterday after an analysis published in the British Medical Journal claimed that “many” of the heart valve replacements using its flagship Sapien heart valve “cannot be justified” and leveled accusations of conflict of interest and unethical conduct against Edwards and Sapien inventor Dr. Martin Leon.

http://www.massdevice.com/news/edwards-lifesciences-slides-rebounds-negative-heart-valve-study

A trio of Belgian researchers said their “rigorous analysis of all the available data, in combination with a study of real world [transcatheter aortic valve implant] practice in Europe, led us to conclude that the arguments supporting the widespread use of TAVI do not stand up to scrutiny.”

“In addition, the Partner trial seems to have important problems, the most relevant being publication bias and lack of data transparency, unbalanced patient characteristics, and incompletely declared conflicts of interest,” wrote Hans Van Brabandt, Mattias Neyt and Frank Hulstaert, who were commissioned by the Belgian government to run the analysis.

Edwards shares closed on 8/1/2012 at $101.20, down 2.2%, 

On 8/2/2012 it closed at 99.30 (0.75 below yesterday)

52wk Range: 61.59 – 106.94

The BMJ researchers wrote that Belgian health authorities should pay for only about 10% of the patients now considered for trancatheter aortic valve replacements in the lowland country – procedures using the Sapien heart valve and a competing device, Medtronic‘s (NYSE:MDT) CoreValve implant, should be limited to patients who aren’t good candidates for traditional open heart surgery. The CoreValve device is not yet approved for the U.S. market.

Edwards’ Partner trial for the Sapien valve was flawed due to potential bias on the part of Leon, according to the researchers. Leon founded a company to develop the implant that Edwards acquired in 2004, triggering a $6.9 million payout that was disclosed. But other milestone payments due to Leon were not disclosed, they wrote, creating “substantial financial interests that we do not believe were fully disclosed.””We believe Dr. Marty Leon has conducted himself throughout the Partner trial in accordance with the highest ethical standards. In his role as co-principal investigator of the trial, he has only been reimbursed for travel-related expenses,” an Edwards spokeswoman told MassDevice.com in an email today. “Dr. Leon also has – throughout the Partner trial – remained in compliance with the strict conflict-of-interest standards of both the FDA and Columbia University. As previously reported, the sale of PVT to Edwards took place in 2004 and the single milestone payment (that Dr. Leon donated to charity) was made in 2006, well before the beginning of the pivotal trial.”The Partner study was also biased by imbalance between the treatment and control groups in the TAVI cohort that favored Sapien, they wrote.Brabandt, Neyt and Hulstaert also claimed that repeated requests to Edwards and Leon for access to data from an FDA-ordered follow-on study of the Sapien device “went unanswered.”

“In our view, this behaviour is both ethically and scientifically unacceptable and should be legally regulated in
future [sic],” they wrote. “Study sponsors should be obliged to make the results of a negative trial public so that policy makers can reach rational and balanced decisions.”

Some of that data, from a 90-patient study of inoperable candidates, was presented at an FDA meeting in July 2011, according to the Belgian researchers. Those results demonstrated a higher risk of mortality after a year among the cohort treated with the Sapien valve (34.3% vs. 21.6%, they wrote).

The researchers also took a shot at the New England Journal of Medicine, which they approached after being rebuffed by Edwards and Leon. The NEJM editors passed the researchers’ “objections” on to the investigators, but the response convinced the editors that “while each of the points we raised deserved a thoughtful review, they did not, either individually or together, fundamentally place the findings of the Partner trial in serious doubt.”

 “NEJM has, however, published 2-year follow-up results that essentially confirmed the one year data. However, it did so without demanding that the study sponsor publish or discuss the negative results of the follow-on trial. It is difficult to understand this decision,” the Belgian researchers wrote.

“Based on current evidence, and considering efficient use of limited resources, it is difficult to see how healthcare payers can justify reimbursing TAVI for patients suitable for surgery, given that the risk of stroke is twice as high after TAVI,” the researches concluded. “In addition, TAVI is much more expensive, on average about €20,000 more per patient in our analysis of Belgian data. Based on observational data, the costs during the initial hospital admission, inclusive of an Edwards Sapien valve of €18,000, are on average €43,600 for TAVI versus €23,700 for surgical valve replacement.”

Transcatheter aortic valve implantation (TAVI): risky and costly

Many of the 40 000 transcatheter procedures so far carried out cannot be justified on medical or cost effectiveness grounds. Hans Van Brabandt, Mattias Neyt, and Frank Hulstaert examine why practice has gone beyond the evidence. The three researchers are:

Hans Van Brabandt researcher 1 2, Mattias Neyt researcher 1, Frank Hulstaert researcher 1

1KCE, Belgian Health Care Knowledge Centre, Administratief Centrum Kruidtuin, Kruidtuinlaan 55, 1000 Brussels, Belgium; 2CEBAM, Belgian Centre for Evidence-Based Medicine and Branch of the Dutch Cochrane Centre, Leuven, Belgium

Correspondence to: M Neyt mattias.neyt@kce.fgov.be

BMJ 2012;345:e4710 doi: 10.1136/bmj.e4710 (Published 31 July 2012) Page 1 of 5

Analysis

Around the world, tens of thousands of people have been treated for a life threatening heart condition using a minimally invasive technique that many see as the wave of the future. Transcatheter aortic valve implantation (TAVI) offers hope to patients too old or too ill for conventional aortic valve replacement operations, and since its introduction 10 years ago it has spread swiftly—by the end of 2011, an estimated 40 000 transcatheter implantations had been done.1 But serious unanswered questions remain over the clinical outcomes and the cost effectiveness of TAVI, as well as the regulatory process that enabled it to gain such a large market so rapidly, particularly in Europe.

Aortic stenosis, the progressive failure of the aortic valve to open fully, is the commonest type of valve disease in elderly people. It is usually treated by valve replacement surgery, but around a third of those who might benefit are turned down because the risks of surgery are too high or because problems such as a calcified aorta or scarring from previous surgery make them unsuitable for surgery.2 Untreated, most will die within five years.3 TAVI offers an alternative, in which a replacement valve is introduced through an artery via a small incision (usually the femoral artery) or, less often, surgically with an incision into the chest and then into the left ventricular apex—the transapical approach.

The numbers who could potentially benefit from TAVI are verylarge.4 Almost 3% of people over 75 have aortic valve disease,5which means that in England alone there are more than 100 000patients in whom aortic valve surgery might at a given moment be contemplated. But only around 1200 aortic valve replacements are carried out in this age group in England each year. This helps explain the enthusiasm with which TAVI has been taken up, and the large potential market. In April 2011, a New York securities analyst for the financial services company Wells Fargo estimated that TAVI could generate more than $2.4bn (£1.5bn; €2bn) in sales in the US and account for more than a third of aortic valve replacements by 2015.6 Cardiologists in the US also expect growing demand from patients who are suitable for conventional surgery but who prefer the quicker and less painful transcatheter option. Data reported at the European Society of Cardiology (EuroPCR) meeting in Paris in May7 suggested that transcatheter procedures have more than tripled in Europe since 2009, rising to 18 372 in 2011. Germany is far ahead of other European nations, being responsible for 43% of all TAVIs, followed by France (13%), Italy (10%), and the UK and Ireland (7%).1

Approval processes

Given the enthusiasm with which the procedure has been adopted, we might expect the evidence for its efficacy to be solid. But a health technology assessment we carried out, commissioned by the Belgian government, concluded that the Belgian health authorities should pay for TAVI in only a minority of patients (10%) of those currently considered for treatment—those who are deemed inoperable for technical reasons such as a series of previous operations or irradiation of the chest wall.8 The United Kingdom’s National Institute for Health and Clinical Excellence (NICE) guidance issued in March this year said that for patients considered unsuitable for surgery, the evidence for TAVI was adequate from a clinical point of view but it did not take costs into account.9 But NICE said that for patients for whom surgery is suitable, albeit risky, the evidence for using TAVI was inadequate, and it should be used in these circumstances only when special arrangements for clinical governance, consent, and data collection or research were in place.9

In the European Union, medical devices fall outside the scope of the European Medicines Agency and need only a simple quality certificate (CE mark) to gain access to the market, putting them on the same footing as domestic appliances such as toasters. Two different valves for transcatheter implantation gained their CE marks in 2007, long before any substantial clinical trial evidence was available: the Edwards Sapien valve and the Medtronics CoreValve. In the US the law demands evidence of efficacy in a randomised trial before the Food and Drug Administration can license any innovative device. Thus TAVI was in use in Europe four years before the FDA licensed the Sapien valve in November 2011, and—in contrast to Europe—only for the transfemoral approach and for patients considered unsuitable for standard valve surgery.10 The transapical route was not approved. In June 2012, a panel of expert advisers recommended that the FDA approved the Sapien valve for high risk operable patients, including a transapical delivery option.11 The advisory panel does not take economic considerations into account.

The European system for approving medical devices has already come in for criticism over breast and hip implants, with the new executive director of the EMA, Guido Rasi, acknowledging in January that there is an urgent need to regulate devices with the same care as medicines. “I think, at the end of the day, we will see everyone moving to increasing use of comparative trials,” Rasi said in an interview with Reuters.12 He expected that concerns about the now defunct French breast implant company Poly Implant Prosthese might help to speed the process. But while the evidence demanded by the FDA exceeded that required in Europe, we remain far from convinced that it is adequate. The Sapien valve was approved on the basis of a trial called PARTNER (Placement of Aortic Transcatheter Valve).

We reviewed the conduct and results of the trial through papers published in peer reviewed journals, proceedings from congresses, press releases, and direct contacts with the manufacturer, the FDA, the New England Journal of Medicine (NEJM) (where it was published), and the principal investigators.

Our rigorous analysis of all the available data, in combination with a study of real world TAVI practice in Europe, led us to conclude that the arguments supporting the widespread use of TAVI do not stand up to scrutiny. In addition, the PARTNER trial seems to have important problems, the most relevant being publication bias and lack of data transparency, unbalanced patient characteristics, and incompletely declared conflicts of interest.

What the evidence shows

PARTNER was a randomised controlled trial in 26 sites, most of them in the US. It allocated patients with severe aortic valve stenosis to two groups: those at very high risk from surgery (cohort A)13 and those deemed inoperable (cohort B).14 The 699 patients in cohort A were randomised either to TAVI or to surgical valve replacement, and the 358 in cohort B were randomised to TAVI or standard therapy, which was balloon aortic valvuloplasty in most cases, combined with medical supportive treatment.

The results showed that in the high risk operable patients, mortality at one year was similar for TAVI and surgical insertion (24.2% v 26.8%, P=0.44) (table⇓). PARTNER was designed as a non-inferiority trial, with a difference of 7.5 percentage points in survival set as the margin, so TAVI met this target. But strokes and transient ischaemic attacks were significantly commoner in the TAVI group at one year (8.3% v 4.3%, P=0.04) and major vascular complications significantly commoner at 30 days (11.0% v 3.2%, P=0.001). Major bleeding and new onset atrial fibrillation were significantly higher in the surgical group. At one year, symptoms were about the same in both groups.13

In the patients deemed inoperable, results were relatively better. Mortality at one year was significantly lower for TAVI (30.7% v 50.7%, P<0.001). Again, however, there was a higher incidence of stroke and major vascular events in the TAVI group (10.6% v 4.5%, P=0.04).14 Taken together, these results suggest that TAVI can be justified for inoperable patients on clinical grounds, though cost effectiveness calculations are more equivocal. But even this conclusion is thrown into doubt by a follow-up study authorised by the FDA, in which 41 inoperable patients were randomised to TAVI and 49 to standard therapy. This study remains unpublished, and our attempts to gain access to further details have been rebuffed by the FDA and the study sponsor. But the data presented at an FDA meeting on 20 July 2011 showed that the TAVI patients fared worse than those given standard therapy (one year mortality 34.3% v 21.6%).15

We have repeatedly sought access to further details of this follow-on trial, carried out under FDA auspices as a formally approved “continued access study,” the purpose of which is to enable sponsors of clinical investigations to continue to enroll patients while a market application is being sought. The FDA responded that any further data analysis of a premarket application is proprietary information and that it was up to the sponsor to release it, if so inclined. But our requests to the sponsor (Edwards) and the principal investigator went unanswered. In our view, this behaviour is both ethically and scientifically unacceptable and should be legally regulated in future. Study sponsors should be obliged to make the results of a negative trial public so that policy makers can reach rational and balanced decisions.

Given our failure to make progress with the FDA or the sponsor, we approached the NEJM which had published the PARTNER trial. We put our objections to the NEJM, which passed them on to the investigators. Their response convinced the NEJM editors that “while each of the points we raised deserved a thoughtful review, they did not, either individually or together, fundamentally place the findings of the PARTNER trial in serious doubt.” Asked what the responses of the investigators had been, NEJM responded that it had not requested permission from them to pass them on, since they were intended for its own confidential evaluation. We were recommended to request this information directly from the study sponsor, which we did, to no avail.

NEJM has, however, published two year follow-up results that essentially confirmed the one year data.16 17 However, it did so without demanding that the study sponsor publish or discuss the negative results of the follow-on trial. It is difficult to understand this decision. Our concerns about the PARTNER trial go further than this, however. Published data on the inoperable patients, who had the most convincing results, show that the treatment and control groups are unbalanced in a way that would favour TAVI. The control group contained more patients with comorbidities, more who had had a previous heart attack, and more who were classified as frail than the TAVI group. There were fewer patients with an extensively calcified aorta. All these differences could have arisen from a flawed randomisation or by chance; but since they favour TAVI, an analysis that adjusted for prognosis at baseline would have produced a more realistic estimate of the effect size.

Disclosure of interests

BMJ 2012;345:e4710 doi: 10.1136/bmj.e4710 (Published 31 July 2012) Page 1 of 5

Practice beyond the evidence

What concerns us most is that in Europe the use of TAVI in the transapical route far exceeds what is justified by the clinical evidence. The PARTNER trial does not provide clear evidence on this route. A subgroup analysis suggests that the transapical approach is not inferior to surgery but has double the risk of stroke. Although the FDA proposed it,19 the trial sponsor declined to include a transapical arm in inoperable patients. But despite this dearth of evidence, TAVI is widely used transapically in Europe.

The UK TAVI registry, for example, shows that 409 of 1620 TAVI patients (25%) were treated transapically, with a one year mortality of 25.5%.20 The FRANCE-2 registry shows that of 2430 patients treated in 2010 and 2011, 20% had transapical TAVI, with a six month mortality of 20.2%.21 We cannot know, of course, what the survival rate of these patients would have been if they had been treated medically or by standard surgery. A position statement by the British Cardiovascular Intervention Society and the Society of Cardiothoracic Surgeons does not distinguish between the transfemoral and transapical approaches despite the different evidence bases.22 It states that TAVI should currently be reserved for patients in whom “the risk/benefit ratio of open heart surgery versus TAVI favours TAVI.” It calls for randomised trials, but only when centres in the UK have got “beyond their learning curve.” Patients may be surprised to hear that trials are being delayed to allow cardiologists and surgeons time to learn the technique.

Concerns about transapical TAVI were heightened by the early termination of a Danish trial called STACCATO,23 which compared transapical TAVI against conventional surgery. Five of 34 TAVI patients and only one of 36 surgically treated patients had either died or had a major stroke or renal failure within 30 days, prompting the data safety monitoring board to call a halt. This discouraging result was reported at the 2011 transcatheter cardiovascular therapeutics conference in San Francisco and drew criticism from Michael Mack, of the University of Texas at Dallas, who said the study was poorly designed and poorly executed.24 Mack, an investigator in the PARTNER trial, said: “I think there is some misinformation here, based on an invalid trial design, that is likely to hurt the field.”

Leif Thuesen, of Aarhus University Hospital in Denmark, who presented the STACCATO results, was more concerned with patients than with the field. “There is no doubt that there are patients who can’t be operated on, and they should be treated with TAVI” he told heartwire. “But the patient who can be operated on—here, we should be very, very cautious. It’s the operable patients, the low-risk patients, they should not have the TAVI procedures, but that’s what is happening. We had one patient, for instance, who did not want the conventional operation, so he had the TAVI procedure in Canada. That’s how it is. Indications are slipping.”24 In contrast to the current situation in Europe, we recommend that marketing approval for a high risk device should be granted for specific indications only. Each of these indications should be supported by clinical evidence from high quality randomised trials. Patients may be at risk if the high risk device is routinely used outside those indications. Payers may have an interest in limiting reimbursement of such high risk devices only to those indications for which there is a high level of evidence of efficacy and cost effectiveness.25

Based on current evidence, and considering efficient use of limited resources, it is difficult to see how healthcare payers can justify reimbursing TAVI for patients suitable for surgery, given that the risk of stroke is twice as high after TAVI. In addition, TAVI is much more expensive, on average about €20,000 more per patient in our analysis of Belgian data. Based on observational data, the costs during the initial hospital admission, inclusive of an Edwards Sapien valve of €18 000, are on average €43 600 for TAVI versus €23 700 for surgical valve replacement. The average cost of transapical TAVI is higher than for the transfemoral approach (€49 800 v €40 900).26 The NICE guidance did not include a cost-benefit analysis, but these costs should be taken into account by local NHS commissioners in decisions about whether to fund the procedure. If policy makers are willing to pay for TAVI, they should give priority to anatomically inoperable patients.8 26 Europe’s lax licensing laws set up in an era where medical devices typically comprised hearing aids, walking frames, and spectacles are not appropriate for implantable devices. It should require high quality randomised trials to show clinical efficacy and safety before granting marketing approval to innovative, high risk medical devices. And a major improvement in transparency of information is also needed to allow clinicians to practise evidence based medicine, patients to make informed decisions, and health technology assessment agencies to make the right judgments.

REFERENCE

1 Nainggolan L. Germany tops TAVI table, but room for growth remains, 1 November, 2011. www.theheart.org/coverages.do.

2 Iung B, Cachier A, Baron G, Messika-Zeitoun D, Delahaye F, Tornos P, et al. Decision-making in elderly patients with severe aortic stenosis: why are so many denied surgery? Eur Heart J 2005;26:2714-20.

3 Varadarajan P, Kapoor N, Bansal RC, Pai RG. Survival in elderly patients with severe aortic stenosis is dramatically improved by aortic valve replacement: results from a cohort of 277 patients aged ≥80 years. Eur J Cardiothorac Surg 2006;30:722-7.

4 Ray S. Estimated population need for TAVI, data presented at a consensus meeting, 16 December 2008. www.ucl.ac.uk/nicor/audits/tavi/pdfs/estimated.

5 Stewart BF, Siscovick D, Lind BK, Gardin JM, Gottdiener JS, Smith VE, et al. Clinical factors associated with calcific aortic valve disease. Cardiovascular Health Study. J Am Coll Cardiol 1997;29:630-4.

6 Cortez M. Edwards valve study may spur patient demand doctors aren’t ready to meet Bloomberg News 2011 Apr 4. www.bloomberg.com/news/2011-04-04/edwards-valvestudy- may-spur-patient-demand-doctors-aren-t-ready-to-meet.html.

7 TAVI numbers rise in Europe as reimbursement, expertise expands. Heartwire 2012 May 17. www.theheart.org/article/1401795.do.

8 Neyt M, Van Brabandt H, Van de Sande S, Devriese S. Transcatheter aortic valve implantation (TAVI): a health technology assessment update. KCE reports 163C. Belgian Health Care Knowledge Centre (KCE), 2011.

9 NICE. Transcatheter aortic valve implantation for aortic stenosis. NICE interventional procedure guidance 421. NICE, 2012.

10 FDA. Edwards SAPIENTM transcatheter heart valve, model 9000TFX, sizes 23mm and 26mm and accessories. www.accessdata.fda.gov/cdrh_docs/pdf10/p100041a.pdf.

11 Wood S. Approve Sapien TAVR for high-risk operable patients, FDA advisors say. Heartwire 2012 Jun 14. www.theheart.org/article/1414539.do.

12 Hirschler B. EU medicines head urges tougher implant rules. 2012 www.reuters.com/ article/2012/01/06/us-breastimplants-ema-idUSTRE8050VL20120106.

13 Smith CR, Leon MB, Mack MJ, Miller DC, Moses JW, Svensson LG, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 2011;364:2187-98.

14 Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 2010;363:1597-607.

15 FDA. SAPIEN THV briefing document—advisory committee meeting. FDA, 2011:301.

16 Makkar RR, Fontana GP, Jilaihawi H, Kapadia S, Pichard AD, Douglas PS, et al. Transcatheter aortic-valve replacement for inoperable severe aortic stenosis. N Engl J Med 2012;366:1696-704.

17 Kodali SK, Williams MR, Smith CR, Svensson LG, Webb JG, Makkar RR, et al. Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med 2012;366:1686-95.

18 Medicine in conflict. Businessweek 2006 Oct 23. www.businessweek.com/magazine/ content/06_43/b4006081.htm.

19 FDA. FDA executive summary: Edwards SAPIEN THV. FDA, 2011.

20 Blackman D. Outcome of TAVI by valve type and access route: UK TAVI registry. 2011. www.pcronline.com/Lectures/2011/Outcome-of-TAVI-by-valve-type-and-access-route.- UK-TAVI-registry.

21 Gilard M. FRANCE II—French aortic national core valve and Edwards registry. EuroPCR conference, Paris, 17-20 May 2011.

22 British Cardiovascular Intervention Society, Society of Cardiothoracic Surgeons. Transcatheter aortic valve implantation (TAVI): a position statement. www.ucl.ac.uk/nicor/ audits/tavi/pdfs/bcisposition.

23 Nielsen HH, Klaaborg KE, Nissen H, Terp K, Mortensen PE, Kjeldsen BJ, et al. A prospective, randomised trial of transapical transcatheter aortic valve implantation vs. surgical aortic valve replacement in operable elderly patients with aortic stenosis: the STACCATO trial. EuroIntervention 2012. May 14. [Epub ahead of print].

24 O’Riordan M. STACCATO; transapical TAVI in surgery-eligible patients stopped due to adverse events. Heartwire 2011 Nov 10. www.theheart.org/article/1307437.do.

25 Hulstaert F, Neyt M, Vinck I, Stordeur S, Huić M, Sauerland S, et al. The pre-market clinical evaluation of innovative high-risk medical devices. KCE Report 158C. D/2011/10.273/31. Belgian Health Care Knowledge Centre, 2011.

26 Neyt M, Van Brabandt H, Devriese S, Van De Sande S. A cost-utility analysis of transcatheter aortic valve implantation in Belgium: focusing on a well-defined and identifiable population. BMJ Open 2012;2:e001032.

 

Table

Table 1| One year mortality and stroke rate in the PARTNER trial13 14 15

Inoperable patients

High risk patients* Pivotal trial† Continued access study‡

TAVI AVR P value TAVI Control P value TAVI Control

No of patients 348 351 179 179 41 49

1 year all cause mortality (% (No of events))§ 24.2 (84) 26.8 (89) 0.44 30.7 (55) 50.7 (89) <0.001 34.3 (13) 21.6 (10)

1 year stroke rate (% (No of events))¶ 8.3 (27) 4.3 (13) 0.04 10.6 (19) 4.5 (8) 0.04 2.4 (1) 0 (0)

TAVI= transcatheter aortic valve implantation, AVR=surgical aortic valve replacement.

*Hazard ratio with TAVI in high risk patients: 0.93 (95% CI 0.71 to 1.22; P=0.62)

†Hazard ratio with TAVI in inoperable patients (pivotal trial): 0.55 (95% CI 0.40 to 0.74; P<0.001);

‡No P value or hazard ratio was published for the continued access study.

§ Kaplan-Meier estimates.

¶ Includes any stroke and transient ischaemic attack; stroke rate in continued access study includes “major stroke” only.

Read Full Post »

Curated by: Dr. V. S. Karra, Ph.D.

Pain is a major symptom in many medical conditions, and can significantly interfere with a person’s quality of life and general functioning.[1]. It is often caused by intense or damaging stimuli, such as stubbing a toe, burning a finger, putting alcohol on a cut, and bumping the “funny bone.”

English: Illustration of the pain pathway in R...

Pain is an absolutely unpleasant one. Knowing the time of onset, location, intensity, pattern of occurrence (continuous, intermittent, etc.), exacerbating and relieving factors, and quality (burning, sharp, etc.) of the pain will help the examining physician to accurately diagnose the problem. For example, chest pain described as extreme heaviness may indicate myocardial infarction, while chest pain described as tearing may indicate aortic dissection.

Acute pain is usually managed with medications such as analgesics and anesthetics. Management of chronic pain, however, is much more difficult and may require an interdisciplinary approach for treating or easing the suffering and improving the quality of life. Psychological factors such as social support, hypnotic suggestion, excitement, or distraction can significantly modulate pain’s intensity or unpleasantness.

The International Association for the Study of Pain (IASP) states that “Pain is an unpleasant sensory and emotional experience associated with actual or potential tissue damage, or described in terms of such damage”.[2].

Following is the IASP’s classification of pain:

(1) region of the body involved (e.g., abdomen, lower limbs),

(2) system whose dysfunction may be causing the pain (e.g., nervous, gastrointestinal),

(3) duration and pattern of occurrence,

(4) intensity and time since onset, and

(5) etiology

This system has been criticized by Clifford J. Woolf and others as inadequate for guiding research and treatment.

According to Woolf, there are three classes of pain :

Nociceptive pain: is caused by stimulation of peripheral nerve fibers and the stimulants could be Thermal, Mechanical and/ or Chemical. For example “heat or cold” (thermal), “crushing, tearing, etc.” (mechanical) and “iodine in a cut, chili powder in the eyes” (chemical).

Inflammatory pain: is associated with tissue damage and the infiltration of immune cells, and

Pathological pain: is a disease state caused by damage to the nervous system (neuropathic pain) or by its abnormal function (dysfunctional pain, like in fibromyalgia, irritable bowel syndrome, tension type headache, etc.).[3]

Pain will have a very detrimental effect on the quality of life. Experimental subjects challenged by acute pain and patients in chronic pain experience impairments in attention control, working memory, mental flexibility, problem solving, and information processing speed.[4]. Acute and chronic pain are also associated with increased depression, anxiety, fear, and anger.[5].

Patients who often have a background level of pain controlled by medications and whos pain periodically “breaks through” the medication is called breathrough pain and it is common in cancer patients . The characteristics of breakthrough cancer pain vary from person to person and according to the cause.

Harold Merskey said: “If I have matters right, the consequences of pain will include direct physical distress, unemployment, financial difficulties, marital disharmony, and difficulties in concentration and attention…”

Pain perception (point at which the stimulus begins to hurt) and tolerance thresholds (point at which the individual can’t tolerate the pain any more and when the subject acts to stop the pain) are not the same. The perception of pain is influenced by a multitude of variables including gender, age, mood, ethnicity and genetic factors [6],

Thus it is important to:

  • understand mechanisms of susceptibility to (chronic) pain,
  • Explore the genetics, emphasizing the conservation of pain-related genes, their functions and their advantages if any
  • Understand the role of gene polymorphisms in normal and pathological modulation of pain in models, humans, and as future drug targets
  • Explore the latest findings from human genome-wide investigation of genomic variability and gene expression on pain
  • Understand genetic and genomic techniques to study genetic contribution to (human) pain.
  • Study the progress of cutting-edge clinical trials and translate research findings to clinical practice
  • develop preventative approaches and novel treatment strategies

Advances in molecular, statistical and behavioral methodologies have suddenly allowed genetic investigations of complex biological phenomena, including pain. Genetic studies of pain are already showing their power to identify new molecular targets for drug development and create new animal models of pain pathology, says Jeffrey S. Mogil, PhD who is currently the E.P. Taylor Professor of Pain Studies and the Canada Research Chair in the Genetics of Pain and wrote a book on “The Genetics of Pain“.

Pain genetics can explain why we’re not all alike with respect to pain – why some people hurt more, and receive less benefit from existing analgesics. The knowledge gained holds the promise of allowing truly individualized pain therapy, says Mogil.

Algorithms for accessing and integrating available public data to examine disease-relevant mechanisms are of growing interest as publically available data sets grow at an ever-increasing rate. A meta-analysis of publicly available microarray data from rodents exposed to neuropathic or inflammatory pain was able to efficiently prioritize pain-related genes [7].

A similar approach using human gene expression data could be highly beneficial in generating data-driven hypotheses for pain genetics.

Most recent article, published on June 7, 2012, in open access journal  PLoS Computational Biology, on “Integrative Approach to Pain Genetics Identifies Pain Sensitivity Loci across Diseases” presented a novel integrative approach that combines publicly available molecular data and automatically extracted knowledge regarding pain contained in the literature to assist the discovery of novel pain genes. This study was approved by the Institutional Review Boards of Stanford University and SRI International.

In this meta-analysis, they took advantage of the vast amount of existing disease-related clinical literature and gene expression microarray data stored in large international repositories and

  • Ranked thousands of diseases according to the Figure shown below.

  • Obtained gene expression profiles of 121 of these human diseases from public sources.
  • Selected ‘genes with expression variation significantly correlated with DSPI across diseases’ as candidate pain genes.
  • Genotyped selected candidate pain genes in an independent human cohort, and finally
  • Evaluated for significant association between variants and measures of pain sensitivity.

In this study, the genes were chosen based on their high correlation with the DSPI and plausible biology as assessed by the available literature and human expression profile across tissue using The Scripps Research Institute BioGPS database [8].

The selected genes were:

  • ABLIM3 (actin binding LIM protein family, member 3),
  • PDE2A (phosphodiesterase 2A, cGMP-stimulated),
  • CREB1 (cAMP responsive element binding protein 1),
  • NAALAD2 (N-acetylated alpha-linked acidic dipeptidase 2), and
  • NCALD (neurocalcin delta).

These genes were selected from the candidate list and were prospectively tested for variants that may be associated with differential pain sensitivity in an independent human cohort.

ABLIM3 was selected as the top candidate as it showed the highest correlation with the DSPI. ABLIM3 is a newly characterized protein-coding gene. ABLIM3 is expressed in various tissues, most prominently in muscle and neuronal tissue [9], [10].

Polymorphisms in ABLIM3 (rs4512126) and NCALD (rs12548828, rs7826700, and rs1075791) showed significant association with the cold pressor pain threshold

“The strongest signal was with rs4512126 (5q32, ABLIM3, P = 1.3×10−10)  for the sensitivity to cold pressor pain in males, but not in females – a sex-specific association.”

Significant associations were also observed with rs12548828, rs7826700 and rs1075791 on 8q22.2 within NCALD (P = 1.7×10−4, 1.8×10−4, and 2.2×10−4 respectively).

Authors said that, “This data-derived list of pain gene candidates enables additional focused and efficient biological studies validating additional candidates.”

Authors have demonstrated the utility of a novel paradigm that integrates publicly available disease-specific gene expression data with clinical data curated from MEDLINE to facilitate the discovery of pain-relevant genes. This approach was validated through a targeted genetic association study in an independent human cohort, where variants of selected pain gene candidates were evaluated for associations with experimental pain sensitivity measures in humans.

Authors hope that “the outlined approach can complement existing research efforts by assisting the formulation of data-driven hypotheses, and may serve as a template to discover genetic components of other clinically important phenotypes.“

Further Reading:

Pain Gene Database (PGD)[11]

MeSH: Medical Subject Heading is a comprehensive vocabulary thesaurus organized in a hierarchical structure allowing the indexing of publications with various levels of specificity.

The 20 diseases with the highest disease-pain ratio from the DSPI are listed out of a total of 2962 diseases are

 .

Curated by: Dr. V. S. Karra, Ph.D.

Read Full Post »

Guidelines for the Diagnosis and Treatment of Endocarditis

from

British Society of Antimicrobial Chemotherapy (BSAC)

Clinicians who care for patients diagnosed with infective endocarditis (IE) are (un)fortunate to be able to refer to several guidelines about its diagnosis and treatment. The guidelines vary considerably, especially with regards to antibiotic prescribing recommendations, which generally reflect local practice and expert opinion in light of largely observational data. All guidelines recommend a multidisciplinary approach to the management of IE.

Infective endocarditis

Infective endocarditis (Photo credit: Wikipedia)

Echocardiography remains a cornerstone of IE diagnosis but is neither 100% sensitive nor specific and multiple scans may be needed to identify vegetations. Echocardiography should also be used in all patients with Staphylococcus aureus bacteraemia. The prevalence of IE among patients with S aureus bacteraemia is variable but was reported as 13% in one large prospective US study and 22% in a recent European study. Clinical assessment is unreliable in diagnosing IE in patients with S aureus bacteraemia and without echocardiography the diagnosis may be missed. Transoesophageal echocardiography is now recommended in most cases of suspected or confirmed IE but may be unnecessary in patients with right-sided valve involvement.

Establishing a microbiological diagnosis in an era of increasingly complex infections with unpredictable resistance patterns is important. However, traditional recommendations for blood culture sampling have been amended for patients with suspected IE and severe sepsis or septic shock. In this situation, two (rather than three) sets of blood cultures, taken at different times within an hour before the start of empirical treatment, are now advised. This is a pragmatic recommendation to avoid undue delay in starting empirical antimicrobial treatment. In other patients, the usual need for three sets of blood cultures is recommended but with at least 6 h between sampling times; an important aim of multiple sampling is to demonstrate the presence of a sustained or persistent bacteraemia, which is characteristic of IE. Identification of atypical micro-organisms using serology in culture-negative cases should be limited to Coxiella and Bartonella in the first instance—a reflection of the extremely small numbers of reported cases of IE caused by Mycoplasma, Brucella and Legionella.

Fungal causes of IE should be considered in culture-negative IE if serology is non-diagnostic and the patient is immunocompromised, has a prosthetic valve, is an intravenous drug user or is not responding to empirical antibacterial treatment. The application of broad-range (16S ribosomal RNA gene) PCR on surgically resected valves or embolic material should be used when culture has failed. False-negative 16S ribosomal RNA gene PCR reactions can occur in the presence of inhibitors of the DNA polymerase within clinical samples or as a result of the vagaries of sampling (ie, processing a piece of tissue that does not contain any bacteria). Bacterial DNA has been shown to be present within cardiac tissue several years after successful treatment of IE, so results should be interpreted with caution in a patient with a previous diagnosis of IE. Application of 16S ribosomal gene PCR to blood in patients with IE is problematic owing to the low levels of bacteria present (1–10 fu/ml) and subsequent difficulty in DNA extraction; as a result it is not currently available for routine clinical use.

Empirical treatment (that started before obtaining a microbiological diagnosis) is generally discouraged, except in those who are acutely unwell or shocked. There is no clear evidence that speeding up the diagnosis, and instigation of treatment, improves outcomes, although this would seem intuitive. Early treatment (started within days of onset of symptoms rather than weeks) is a laudable aim, but the few days delay in hospital while appropriate echocardiographic and microbiological tests are undertaken on a stable patient are unlikely to have a negative impact on outcome. Conversely, the administration of broad-spectrum antibiotics when the diagnosis of IE has not been considered (and often when inadequate samples have been obtained) may have considerable impact on the ability to establish the diagnosis and subsequently deliver effective treatment.

Outpatient antibiotic treatment (OPAT) for IE is included in the BSAC guidelines in response to increasing efforts to expand these services and manage more patients outside hospital. Patients who might be considered for OPAT include those who are stable and responding well to treatment, are without signs of heart failure and without any indications for surgery or uncontrolled extracardiac foci of infection. Delivery of OPAT requires appropriate funding, support and infrastructure, coupled with the ability to rapidly access inpatient services and obtain urgent expert advice if needed. This has been proved to be feasible and safe in the UK, even in high-risk IE cases.

Although the guidelines include recommendations for most causes of IE, the predominant pathogens remain staphylococci, streptococci and enterococci. Routine addition of gentamicin to flucloxacillin for the treatment of native valve staphylococcal IE is no longer recommended (see Table 1). This recommendation is unchanged from previous BSAC guidelines but the ESC continue to include gentamicin as an optional addition. Further evidence of the toxicity of gentamicin has been published, based on findings from a randomised controlled trial comparing daptomycin with either vancomycin or cloxacillin plus gentamicin for the treatment of S aureus bloodstream infection or IE Recommendations for meticillin-resistant staphylococci also differ from those of the ESC; although vancomycin is the primary agent in both sets of guidelines, rifampicin is recommended by BSAC in place of gentamicin because of concerns about efficacy and toxicity. Daptomycin, a recently licensed lipopeptide, is also recommended as an alternative agent for patients who are intolerant to vancomycin or have infection caused by vancomycin-resistant isolates.

Previous recommendations for treatment of streptococcal IE have been simplified, with greater emphasis placed on benzylpenicillin rather than amoxicillin as the primary agent to reduce risk of Clostridium difficile infection. Enterococcal treatment regimens are largely consistent with the ESC guidelines, though a low threshold for withdrawing gentamicin in patients with deteriorating renal function or other signs of toxicity is advised, based on observational data that shorter gentamicin courses are not associated with worse outcomes.

The timing of cardiac surgery in IE should be evaluated by the multidisciplinary team on a case by case basis. Attempts to advise whether cardiac surgery should be emergent, urgent or elective can seem artificial. The traditional indications for surgery in IE are well established but it is becoming apparent that patients with IE caused by S aureus, or patients with evidence of systemic embolisation, should also be considered for early surgery, which may confer a mortality benefit.

Device-related infections have been deliberately omitted from the current BSAC guidance as the challenges in preventing, diagnosing and treating cases of intracardiac device IE are different from ‘traditional’ native or prosthetic valve IE. Further specific device-related guidance is likely to be published in the future and a joint working party involving the BSAC, BCS and Heart Rhythm UK has been established. IE guidelines are always imperfect owing to the difficulties in studying this relatively uncommon condition and the scarcity of randomised trials. At present, we are uncertain of the incidence, risk factors, causative micro-organisms (and their antimicrobial sensitivities), and patient outcomes in IE affecting the UK population. A recently established national endocarditis database may help to answer some of these questions, but its success will be crucially determined by the degree of support and national participation. See http://www.neemo.leedsth.nhs.uk/ (only via the N3 network) for details.

see source for more

Reported by: Dr. V. S. Karra, Ph.D

Read Full Post »

A Word of Caution especially to Cardiacs’

Zithromax (azithromycin), is not only a more expensive antibiotic than other antibiotics but also seems to be an expensive one at Heart. Doctors should weigh other options for people already prone to heart problems, the researchers and other experts suggested. It is a popular antibiotic because it often can be taken for a fewer days compared to other antibiotics, for example: about 10 days for amoxicillin and other antibiotics and five-day course will suffice in case of Zithromax.

Azithromycin

Azithromycin (Photo credit: Wikipedia)

It is widely used for bronchitis, sinus infections and pneumonia, and other common infections but seems to increase chances for sudden deadly heart problems. A rare but surprising risk found in a 14-year study. Also, antibiotics in the same class as Zithromax have been linked with sudden cardiac death. In the current study, patients those on Zithromax were about as healthy as those on other antibiotics, making it unlikely that an underlying condition might explain the increased death risk, researchers said.

Researchers analysis at Vanderbilt University indicates that there were 29 heart-related deaths among those who took Zithromax during five days of treatment. Their risk of death while taking the drug was more than double that of patients on another antibiotic, amoxicillin, or those who took none.

To compare risks, the researchers calculated that the number of deaths per 1 million courses of antibiotics would be about 85 among Zithromax patients versus 32 among amoxicillin patients and 30 among those on no antibiotics. The highest risks were in Zithromax patients with existing heart problems. Patients in each group started out with comparable risks for heart trouble, the researchers said. The results suggest there would be 47 extra heart-related deaths per 1 million courses of treatment with Zithromax. The risk of cardiovascular death was significantly greater with azithromycin than with ciprofloxacin but did not differ significantly from that with levofloxacin.

Dr. Harlan Krumholz, a Yale University health outcomes specialist who was not involved in the study said that “People need to recognize that the overall risk is low,”. More research is needed to confirm the findings, but still, he said patients with heart disease “should probably be steered away” from Zithromax for now.

At the same time, Dr. Bruce Psaty, a professor of medicine at the University of Washington, of opinion that doctors and patients need to know about the potential risks. He said the results also raise concerns about long-term use of Zithromax, which other research suggests could benefit people with severe lung disease. Additional research is needed to determine if that kind of use could be dangerous, he said.

The study appears in the New England Journal of Medicine. The National Heart, Lung and Blood Institute helped pay for the research. Wayne Ray, a Vanderbilt professor of medicine, studied the drug’s risks because of evidence linking it with potential heart rhythm problems.

Pfizer is committed to patients safety and issued a statement saying it would thoroughly review the study and “Patient safety is of the utmost importance to Pfizer and we continuously monitor the safety and efficacy of our products to ensure that the benefits and risks are accurately described,” the company said.

Source

Additional info on Zithromax

Reported by Dr. Venkat Karra, Ph.D

Read Full Post »

Methylation of the gene F2RL3—which has been linked with platelet activation and inflammation—was lowest in smokers and highest in nonsmokers. Methylation is an important source of variation and regulation in the genome in Epigenetic modification of DNA. In a prospective study in patients with stable coronary heart disease, lower F2RL3 methylation in smokers and former smokers indicated a worse prognosis with excess cardiovascular mortality as well as overall mortality.

The authors found a correlation between F2RL3 methylation intensity and established prognostic markers, including natriuretic peptide, C-reactive protein, and interleukin-6. Current standard medical treatment for coronary artery disease did not affect F2RL3 methylation.

This article was published in European Heart Journal

L. P. Breitling et al., Smoking, F2RL3 methylation, and prognosis in stable coronary heart disease. Eur. Heart J. 17 April 2012

http://eurheartj.oxfordjournals.org/content/early/2012/04/16/eurheartj.ehs091.abstract

Read Full Post »

Reporter: Venkat Karra, Ph.D.

Researchers at Singapore’s Institute of Bioengineering and Nanotechnology (IBN) have developed a miniaturized biochip that promises to boost the development of more effective cancer drugs.

The Agency for Science, Technology and Research said on Wednesday that its research into the effect of drugs on cancer stem cells (CSCs) would shed light on cells that are resistant to drugs, local TV Channel NewsAsia reported.

It also explained how the technology works on CSCs, which form a small and distinct class of cancer cells in a tumor.

CSCs are more resistant to chemotherapy and if they are not eradicated, CSCs can repopulate the tumor and lead to cancer recurrence. It is therefore important for researchers to understand the efficacy of anti-cancer drugs against CSCs.

However, CSCs are scarce, making up about 1 percent of cancer cells.

This hampers studies using conventional drug screening methods, which require large sample volumes and are slow and expensive.

The IBN researchers found an answer, by developing a miniaturized biological assay, called the Droplet Array. It performs cheaper, faster and more convenient drug screening using limited samples.

In traditional biological assays, microplates — a flat plate with multiple wells in which samples are placed – are commonly used. Each requires at least 2,500 or 5,000 cells, to be present for viable analysis. IBN’s Droplet Array requires only 500 cells for screening. This massive reduction in sample volume saves money and makes it easier to study scarce quantities of target cells, such as CSCs.

IBN executive director, Professor Jackie Y Ying, who led the study, was quoted as saying that the Droplet Array marks a significant breakthrough in nanotechnology and lab-on-a-chip concepts. It also provides an efficient platform to speed up drug screening and development.

source:

http://www.chinadaily.com.cn/xinhua/2012-05-09/content_5868419.html

Reporter: Venkat Karra

Read Full Post »

« Newer Posts