Learn the basics of fluorescence compensation’s role in flow cytometry
Compensation is a critical topic for flow cytometry, yet it is poorly understood. Within a flow cytometer, the appropriate ranges of excitation and emission wavelengths are selected by bandpass filters. But when emission spectra overlap, fluorescence from more than one fluorochrome may be detected. To correct for this spectral overlap, the fluorescence compensation process ensures that the fluorescence detected in a particular detector derives from the fluorochrome that is being measured.
This article discusses the principles of compensation to help those who use flow cytometry to master it for research experiments.
Instrumentation advances add flexibility and quantitation to flow cytometry
Giacomo Vacca and Jessica P. Houston
Despite its usefulness for bioimaging, fluorescence tagging has critical limitations. But a variant called fluorescence lifetime inherently solves longstanding problems and offers additional benefits that allow the use of more parameters. With new instrumentation developments, these capabilities are now enabling quantitative flow cytometry, which promises to advance cell biology in important ways.
Fluorescence labels have advanced cell biology and cytometry by enabling the study of cellular function and structure. The ability to attach a wide range of fluorophores to different antibodies has made it possible to classify and map the diverse populations of white blood cells that make up the human immune system, for instance. And the stunning images produced by confocal fluorescence microscopy have not only elucidated the relationships of subcellular structures previously only guessed at, but have also captured the popular imagination (witness the 2014 Nobel Prize in chemistry for super-resolved fluorescence microscopy). Fluorescence-based tools are here to stay.
For all its successes, however, fluorescence tagging seems to have hit a ceiling—even as applications demand ever-greater performance.
One challenge is that fluorophores, the molecules responsible for fluorescent behavior, are not always as well-behaved as we would like them to be. Overwhelmingly organic in nature, their synthesis can be complex, their stability is not guaranteed, and unlike the on-off states of digital switches, their fluorescence performance is governed by absorption and emission spectra-mechanisms firmly rooted in the analog world and subject to nonlinearities. The net effect is considerable uncertainty in the amount of light one can expect a given fluorophore to emit, even with a fixed excitation. When fluorophores are combined—for example, in applications of fluorescence resonance energy transfer (FRET)—the uncertainties add, preventing the results from being reliable quantitatively.
Another problem is that most fluorophores have relatively broad emission spectra—on the order of 30–50 nm. The availability of light sources and detectors (combined with the absorption curve of water) constrains the usable portion of the spectrum to some 400 nm, spanning the visible range and little more. To make the most of this limited range, microscopists and cytometrists have pushed for the development of large libraries of fluorophores with almost any peak emission wavelength in the visible spectrum. But while hundreds of choices exist, only a handful can be used simultaneously, with their spectra spread sufficiently to allow for differential detection. This forces experiments to be run sequentially instead of in parallel—a nuisance in microscopy and a severe limitation in flow cytometry, where sequential interrogation of a single cell is incompatible with the nature of the technique. In other words, the multiplexing capability of fluorescence-based approaches is capped at a low level.
Why fluorescence lifetime?
Detection of fluorescence lifetime offers a solution to both problems. When a fluorophore absorbs an incoming excitation photon, it spends a certain amount of time in the excited state before emitting a longer-wavelength photon and returning to its ground state. A collection of identical fluorophores will generate a distribution of time intervals between absorption and emission; this statistical distribution takes the shape of an exponential decay curve (see Fig. 1a), and can be characterized by its 1/e point τ—the lifetime of this fluorescent transition. Critically, the lifetime value τ is completely independent of intensity (see Fig. 1b). This characteristic makes lifetime measurements insensitive to fluctuations in the intensity of the light source, as well as to variations in the amount of light ultimately absorbed by the fluorophores.
http://www.bioopticsworld.com/content/dam/bow/print-articles/2015/01/1501BOWvaccaF1.jpg
FIGURE 1. A collection of fluorophores, excited by a short optical pulse (thick line), produces collective fluorescence emission that follows an exponential decay curve with 1/e lifetime τ (a). Regardless of the intensity of the excitation pulse, the decays from identical fluorophores all have the same characteristic lifetime τ (b).
By virtue of its insensitivity to intensity fluctuations, fluorescence lifetime lends itself particularly well to quantitative studies. In the case of FRET, the difference between intensity-based and lifetime-based measurements is even more critical, as FRET assays rely on the interaction between two fluorophores. Not only do intensity fluctuations cause uncertainty in the absorption process, but the energy transfer process itself, between the two fluorophores in the FRET pair, is affected by intensity variations—further confounding the results. Measuring fluorescence lifetime makes it possible to eliminate these spurious effects and carry out quantitative FRET applications; for instance, measurements on protein folding and conformation, and on protein-protein interactions.
Fluorescence lifetime has some additional benefits. The lifetime of a fluorescent transition can be influenced by the local molecular environment of the fluorophore. For example, certain fluorophores exhibit a dependence of their lifetime on the pH of the medium surrounding them;1 or they can be sensitive to the concentration of certain ions, such as Ca++.2 This sensitivity can be exploited to use lifetime as a local, molecular-scale probe of environmental conditions.
Measurements of fluorescence lifetime have been implemented successfully on imaging platforms. In particular, a technique called time-correlated single-photon counting (TCSPC) has been widely used to generate fluorescence lifetime analysis on advanced microscopes. Developers of TCSPC detection systems, such as Becker & Hickl GmbH and PicoQuant GmbH (both of Berlin, Germany), offer a rich portfolio of products aimed at imaging applications of fluorescence lifetime. The plethora of results3 made possible by their technologies is a testament to the power of fluorescence lifetime imaging microscopy (FLIM) techniques. FLIM-FRET in particular has enjoyed growing popularity.4
However, the slow data acquisition rates of TCSPC, added to the inherent low throughput of microscopy, severely limit the efficiency of analysis. Processing a field of view with perhaps 50 cells can take minutes; while FLIM provides spatially resolved information on each cell, it comes at a steep price in terms of throughput trade-offs. FLIM is a great technique for detailed analysis of handfuls of cells, but it is poorly suited to the rapid analysis or screening of thousands to millions of cells.
For those applications where localization information is not critical, it is highly desirable to trade spatial resolution for analysis throughput. Flow cytometry does just that: By interrogating single cells in a narrow stream flowing at high speeds past a laser interrogation point, it can routinely deliver analysis rates on the order of 10,000 cells per second-three to four orders of magnitude faster than is possible with microscopy-based tools. And while one of the trade-offs is imaging information, flow cytometry offers multiplexed analysis to compensate, in part, for that.
Fluorescence lifetime flow cytometry
It is therefore natural to want to combine the benefits of fluorescence lifetime with the high throughput of flow cytometry. Early work in this direction was spearheaded by John Steinkamp and collaborators at Los Alamos National Laboratory (LANL) in the 1990s,5-8 and briefly explored commercially by BD Biosciences (San Jose, CA) through the work of Robert Hoffman and collaborators9 around the same time. Those undertakings were largely based on analog-electronics implementations of a fluorescence lifetime technique referred to as “phase lifetime” or “frequency-domain lifetime.” More recently, researchers at New Mexico State University (NMSU) have revitalized the field with the introduction of new digital fluorescence lifetime technologies for cell sorting and analysis.10 These efforts also involve frequency modulation approaches, and have led to phasor analysis and non-modulated approaches to lifetime.11,12
The early pioneering experiments were crucial for establishing the viability of performing fluorescence lifetime measurements in flow, but traditional instrumentation and signal processing tools used to perform the measurements were complex, expensive, and did not lend themselves to commercialization. For this reason, the new digital approaches are appealing. The frequency-domain approaches, however, can reliably report only a single lifetime component (an area NMSU researchers are now exploring), whereas for the technique to have practical value, flow cytometrists would need it to resolve multiple lifetime components within any single cell.
An academic/commercial collaboration (between NMSU and Kinetic River Corp.) supported by the NSF CAREER DBI 1150202 project has produced a new approach that, like its TCSPC FLIM counterpart, is based on the time domain: Fluorescence lifetime values are extracted directly from the fluorescence decay curves emitted in response to pulsed excitation. This has allowed resolution of multiple components of fluorescence lifetime within individual decay curves13—to our knowledge, the first such feat performed at the speeds of particle flow typical of flow cytometry (see Fig. 2).
http://www.bioopticsworld.com/content/dam/bow/print-articles/2015/01/1501BOWvaccaF2.jpg
FIGURE 2. Time-domain fluorescence lifetime flow cytometry results from ethidium bromide (EB) in Chinese Hamster Ovary cells (CHO-K1). The multiexponential decay curve in this case comprises two distinct lifetimes (τ1 and τ2), each contributing to the overall curve in proportion to the corresponding population of fluorophores (unbound and DNA-bound EB, respectively).
The first instrument to emerge from this collaboration, the Danube I, proved that our approach is feasible. It has been in use at NMSU since late 2012. That prototype is capable of multi-exponential decay measurements; it has a lifetime resolution of around 2 ns—sufficient for proving the concept and even for certain applications, but not enough to measure the shorter lifetimes of many fluorophores of interest. A second-generation instrument, the Danube II (completed in the summer of 2014), delivers shorter pulses and higher sensitivity, and the NMSU lab plans to introduce a range of laser modulation and digital signal processing approaches onto this instrument for more novel ways to measure fluorescence lifetimes. We expect this system to yield sub-nanosecond lifetime resolution.
……..
The short distance between, and proper alignment of, donor and acceptor ensure that, upon excitation by light in the donor absorption spectrum, efficient FRET takes place, transferring excitation energy to the acceptor molecule. As the donor produces fluorescence emission, the lifetime of the transition is reduced by the presence of the acceptor. Figure 4b shows how, when a protease severs the linker, the donor and acceptor molecules no longer undergo FRET, and the lifetime of the donor emission returns to its longer native value.
http://www.bioopticsworld.com/content/dam/bow/print-articles/2015/01/1501BOWvaccaF4.jpg
FIGURE 4. Fluorescence lifetime can study apoptosis mediated by proteases. See text for details.12
More broadly, the subject of fluorescence lifetime flow cytometry is enjoying a veritable renaissance. At the last Annual Congress of Cytometry (CYTO, May 2014, Ft. Lauderdale, FL), a new workshop on fluorescence lifetime,15 co-chaired by Silas Leavesley, of South Alabama University (Mobile, AL), featured a distinguished panel (see Fig. 3) that included Prof. Suzuki, who gave the latest results on her work on FRET bioprobes; Patrick Jenkins of NMSU and the Fred Hutchinson Cancer Research Center (Seattle, WA), who talked about using fluorescence lifetime to study cell signaling in yeast cells using FRET; János Szöll“osi of Debrecen University (Hungary), an expert in applying FRET-FLIM to cell signaling pathways in cancer research; and Ralph Jimenez of JILA/NIST and the University of Colorado (Boulder), who presented his work on the relationship of fluorescence lifetime and photostability in fluorescent proteins. Jenkins also demonstrated sorting of cells based on differences in fluorescence lifetime alone.16 And at the most recent Cytometry Development Workshop (October 30–November 2, 2014; La Jolla, CA), fluorescence lifetime flow cytometry was the topic area with the largest number of presented talks, according to the workshop summary by Morgan Richert of the Scintillon Institute.
The early interest in multi-exponential fluorescence lifetime flow cytometry has focused on quantitative FRET—a broad set of applications where the ability to accurately resolve multiple fluorescence decay components can make the most immediate difference (see Fig. 4). As researchers become more familiar with fluorescence lifetime, other kinds of applications will follow suit. Researchers at NMSU are pursuing measurements of autofluorescence to differentiate normal from cancerous cells. By measuring the different lifetimes of endogenously fluorescent compound NADH in its free and bound states, one can distinguish cells with normal metabolism and ones with abnormally high metabolic rates—a hallmark of cancer. Being able to do so on a flow cytometry platform would allow rapid discrimination of cancer cells out of large samples of normal background cells. NMSU researchers are also now sorting cells using the fluorescence lifetime as a single parameter.12 Therefore, sorting out cells with altered metabolism based on fluorescence decay times is near.
http://www.bioopticsworld.com/content/dam/bow/print-articles/2015/01/1501BOWvaccaF5.jpg
FIGURE 5. (a) Traditional multiplexing schemes for fluorescence in cytometry and microscopy have relied on tight packing of fluorescence emission bands (colored curves) into the limited spectral range of visible light (wavelength axis λ). This approach is constrained by the breadth of the emission spectra and their overlaps (shaded areas), which cause unwanted spillover and require burdensome compensation. (b) By using fluorescence lifetime, one is able to open up an entire new dimension in multiplexing (vertical axis τ), and for each fluorescence spectral band (FL1,FL2, etc.) exploit several lifetime bands (e.g., τ1, τ2, τ3). Each intersection point (like the thick black square indicated for FL2 and τ2) represents a unique combination (a “channel”) of wavelength and lifetime. By spreading out the fluorescence bands, the spectral spillover problem is reduced or eliminated, while still increasing the number of effective channels available.
An even broader goal is to use fluorescence lifetime as a separate dimension to massively increase the multiplexing capabilities of flow cytometers (see Fig. 5b). By using fluorescence lifetime as a parameter, spectrally overlapping emissions can be distinguished. Even just doubling the number of channels available for detection—a rather conservative estimate of the potential benefit of multiplexing with fluorescence lifetime—would be a huge boon to immunologists and other cell biology researchers currently forced to work with a limited number of tags on the single cramped dimension of the visible spectrum.
….. more
In vivo spectroscopy technique could advance medical diagnostics and research
http://www.bioopticsworld.com/articles/2015/11/in-vivo-spectroscopy-technique-could-advance-medical-diagnostics-and-research.html
Although optical spectroscopy has been routinely used to study molecules in a sample cell, it is currently not practical to perform in vivo spectroscopy, or the analysis of how light interacts with molecules in living tissue. This is because photons strongly scatter when light shines through tissues, making detection of the signal through a spectrometer inefficient, Cheng says.
The new technique works by “coding” individual photons from a pulsing laser with a megahertz radio frequency and then collecting those photons with a detector after they have interacted with tissue. The system was demonstrated in human breast cancer detection. Ordinarily, the cancer tissue samples would have to be processed for histological examination, which could take up to a week. The new technology yields results in about 2 s.

The innovation offers “label-free” detection, or imaging that does not require the use of fluorescent dyes or other preparations to detect structures and features. Because processing kills the tissue and is time-consuming, Cheng says, the label-free technology allows the study of unaltered living tissues and cells, making for more rapid and accurate studies.

Flow cytometry involves injecting fluorescent dye into the blood; the dye molecules bind to tumor cells, leaving all other cells unmarked. While adding dye to a blood sample is typically a manual process, the PoCyton automates it. Within the system, the tagged blood is funneled through a narrow focal area, causing suspended cells to pass in front of a laser spot detector one by one. The light causes the cancer cells to fluoresce, enabling the device to detect and count them. This narrow passage is the key to the PoCyton process: its geometry ensures that every object flowing past the detector is registered, and no cell is hidden behind another. This is critical because even in a severely sick patient, only five in approximately one billion suspended objects in a 10 mL sample of blood is a CTC. The researchers report that the device provides adequate sensitivity, and they are now working to create a fully functional prototype.
Besides counting of CTCs, the PoCyton could enable detection of legionella bacteria in drinking water, which can cause Legionnaire’s disease.
Spectroscopy method to help develop motion-sensitive human-computer technologies
The Fraunhofer Institute of Industrial Engineering (IAO) opened its NeuroLab test environment, where researchers are applying neuroscience knowledge — including a spectroscopy method — to ergonomic workplace design issues, with focus on assistance systems in vehicles, in human-robot collaboration, and in knowledge work. View more >>
Spectroscopy helps show relationship between male brain activity and fitness
An optical neuroimaging technique called functional near-infrared spectroscopy (fNIRS) helped to show the direct relationship between brain activity, brain function, and physical fitness in a group of older Japanese men. View more
Leave a Reply